CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH

Similar documents
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

How To Test A Power Switch On A Power Supply

SWITCHGEAR. EGP Switchgear

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ASCO SERIES 185 Power Transfer Switches

ATC-300 Automatic Transfer Switch Controller

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

RM4TG20 three-phase network control relay RM4-T - range V

Secondary Unit Substations

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

STRATO LED Drivers 70W, Single output

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Eaton Automatic Transfer Switches

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Continuous Power... Continuous Protection

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Medium Voltage Motor Control Assemblies

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Telephone- and leased line modem for industrial applications TD-36

CTS SERIES AUTOMATIC TRANSFER SWITCH

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

SECTION DETECTION AND ALARM

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Arc Terminator Active Arc-Resistant Switchgear

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Distribution Dry Type Transformers

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Rotary Disconnect Switch Specifications

15 Series - Electronic step relay and dimmer. Features SERIE

Integrated Power Systems for Data Centers

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Safety technique. Emergency stop module BO 5988 safemaster

Transfer switch BTPC open, closed or delayed transition

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Electronic overload relay EF65, EF96 and EF146

MCC Ratings. Voltage Rating

7.5 Watt AC-DC Switch Power Supply

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Solid State Timers Type F

8146/5 Series Breaker Panelboards

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

3500/62 Process Variable Monitor

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Rack mounted telephone- and leased line modem for industrial applications

SMC -3 Specifications

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Bulletin 150 SMC Flex Smart Motor Controller Specifications

SMART Board interactive flat panel with appliance Model 8055ie-SMP

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Diesel Engine Driven Generators Page 1 of 6

Electronic overload relay EF19 and EF45

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

Bolted contact switches. Pringle switches

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

Bimetallic Overload Relay Specifications

Centro-Matic Automatic Lubrication Systems System Controls

Low Voltage Products. Switches Automatic Transfer Switches

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Foxboro Evo Process Automation System

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Circuit Breakers. Next Generation of Protection Capabilities

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

HMI display Installation Guide

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

DIESEL GENERATOR SETS

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Engineers Edge, LLC PDH & Professional Training

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Power Management Module 2. Installation

Analog signal converters CC-E I/I Current / current isolators

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Transcription:

CAT ATC CONTACTOR- BASED BYPASS ISOLATION AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Contactor -based Bypass Isolation ATS are available from 100A to 1200A. Image Shown may not Reflect Actual Package FEATURES ATC-300+ or ATC-800 microprocessor-based controller True RMS voltage and frequency sensing Maintains fully automatic capability while in bypass mode (optional) Single motion rack-out with the door closed Multiple field programmable time delays Switch position indication Source availability indication Source 1 and 2 auxiliary contacts Programmable plant exerciser System test pushbutton Load shed from emergency Mimic diagram Ability to test power switching isolated components LEHE0062-05

OPTIONS Drawout capabilities on both ATS bypass portions and power switching devices completely interchangeable between ATS and bypass units Open, Delayed or Closed Transition 2- or 4-position test switch Multi-meter options available Selectable Automatic or Non-Automatic operation Space heaters (recommended for use in NEMA 3R enclosures) Load sequencing contacts Surge suppression Remote communications Seismic Qualified (BOCA, CBC, IBC, UBC) Field selectable, multi ratio, control voltage transformer 50/60 Hz Dual drawout type is field configurable for top or bottom conduit entry OPTIONAL DELAYED TRANSITION INCLUDES: Time Delay Neutral Pre-Transfer Signal with 1 N.O. and 1 N.C. contacts 600-1200A Dual Drawout Bypass Isolation RATINGS 100-1200A 2-, 3-, 4-pole 120 600 Vac 50/60 Hz Up to 65 kaic withstand UL 1008 listed CSA C22.2 No. 178 certified IBC 2006, CBC 2007 and OSHPD CONTROLS AND WIRING All control relays and industrial-grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90ºC rated and all control wire is #16 and #18 AWG, type XLPE with a 125 C temperature rating. ENCLOSURE Durable powder-coated steel NEMA 1, 3R, or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches. 100-400A Fixed Bypass Isolation Shown with top and bottom panels removed LEHE0062-05 2

TESTING STANDARDS UL 991 UL standards for safety tests for safety-related IEC 1000-5 Surge withstand tests controls employing solid-state devices NEMA ICS 109.21 Impulse withstand test UL 1008 Dielectric test (endurance, withstand, etc.) CSA conformance C22.2 No. 178-1978 (reaffirmed 1992) IEEE 472 (ANSI C37.90A) Ringing wave UL 869A Reference Std for Service Equipment immunity/voltage surge test UL 50/508 Enclosures EN55022 (CISPR11): Conducted and radiated emissions NEMA ICS 1 General standards for industrial control system EN61000-4-2 Class B Level 4 ESD immunity test NEMA ICS 2 Standards for industrial control devices, EN61000-4-3 (ENV50140) radiated RF, controllers, and assemblies electromagnetic field immunity test NEMA ICS 6 Enclosures for industrial controls and systems EN61000-4-4 Electrical fast transient/burst immunity test NEMA ICS 10-1993 AC automatic transfer switches EN61000-4-5 IEEE C62.41: Surge immunity test ANSI C33.76 Enclosures EN61000-4-6 (ENV50141) Conducted immunity test NEC 517, 700, 701, and 702 National Electrical Code EN61000-4-11 Voltage dips and interruption immunity NFPA 70 National Fire Protection Agency FCC Part 15 Conducted/radiated emissions (Class A) NFPA 99 Health care facilities CISPR 11 Conducted/radiated emissions (Class A) NFPA 101 Life safety code IEC 1000-2 Electrostatic discharge test NFPA 110 Emergency and standby power systems IEC 1000-3 Radiated susceptibility tests EGSA 100S Standard for transfer switches IEC 1000-4 Fast transient tests CSA C22.2 No. 178-1978 Canadian Standards Association UL 1008 WITHSTAND AND CLOSE-ON RATINGS (ka) 480 V 600 V UL 1008 Any Specific Any Specific Rating Breaker Breaker Breaker Breaker 100 30,000 50,000 22,000 35,000 150 30,000 50,000 22,000 35,000 200 30,000 30,000 22,000 35,000 225 30,000 50,000 42,000 65,000 260 30,000 50,000 42,000 65,000 320 30,000 50,000 42,000 65,000 400 30,000 50,000 42,000 65,000 600 50,000 65,000 42,000 65,000 800 50,000 65,000 42,000 65,000 1000 50,000 65,000 42,000 65,000 1200 50,000 65,000 42,000 65,000 LEHE0062-05 3

FIXED & DRAWOUT BYPASS ISOLATION CONTACTOR BASED TRANSFER SWITCHES 100-400A* Ampere Number Conduit Shipping Rating of Poles Entry Height Width Depth Weight Lbs. (kg) NEMA 1 Drawout Bypass 1 100-400A 120-480V 2 Either 78 (1981) 30 (762) 29 (737) 600 (273) & 3 Either 78 (1981) 30 (762) 29 (737) 625 (284) 100-200A @ 600V 4 Either 78 (1981) 30 (762) 29 (737) 650 (295) NEMA 3R Drawout Bypass 1 100-400A 120-480V 2 Either 78 (1981) 30 (762) 48 (1219) 625 (284) & 3 Either 78 (1981) 30 (762) 48 (1219) 650 (295) 100-200A @ 600V 4 Either 78 (1981) 30 (762) 48 (1219) 675 (307) NEMA 1 Fixed Bypass 2 100-400A 120-480V 2 Either 78 (1981) 30 (762) 29 (737) 600 (273) & 3 Either 78 (1981) 30 (762) 29 (737) 625 (284) 100-200A @ 600V 4 Either 78 (1981) 30 (762) 29 (737) 650 (295) NEMA 3R Fixed Bypass 2 100-400A 120-480V 2 Either 78 (1981) 30 (762) 48 (1219) 625 (284) & 3 Either 78 (1981) 30 (762) 48 (1219) 650 (295) 100-200A @ 600V 4 Either 78 (1981) 30 (762) 48 (1219) 675 (307) Dimensions in Inches (mm) & Approximate Shipping lbs (kg) * Add 6" to width for seismic brackets where required 1 Dual drawout type is field configurable for top or bottom entry 2 Fixed type conduit entry (top or bottom) must be specified at type of order All dimensions and weights are approximate and subject to change without notice and are not for construction use. LEHE0062-05 4

FIXED& DRAWOUT BYPASS ISOLATION CONTACTOR BASED TRANSFER SWITCHES 100A-1200A* Ampere Number Conduit Shipping Rating of Poles Entry Height Width Depth Weight Lbs. (kg) NEMA 1 Drawout Bypass 1 600-1200A 120-600V 2 Either 90 (2286) 40 (1016) 29 (737) 1800 (816) 3 Either 90 (2286) 40 (1016) 29 (737) 1850 (839) 4 Either 90 (2286) 40 (1016) 29 (737) 1900 (862) NEMA 3R Drawout Bypass 1 600-1200A 120-600V 2 Either 91 (2311) 41 (1041) 48 (1219) 1850 (839) 3 Either 91 (2311) 41 (1041) 48 (1219) 1900 (862) 4 Either 91 (2311) 41 (1041) 48 (1219) 1950 (885) NEMA 1 Fixed Bypass 2 2 Either 90 (2286) 40 (1016) 29 (737) 1500 (680) 600A 120-600V 800-1200A 120-600V 3 Either 90 (2286) 40 (1016) 29 (737) 1550 (703) 4 Either 90 (2286) 40 (1016) 29 (737) 1600 (726) 2 Either 90 (2286) 40 (1016) 29 (737) 1700 (771) 3 Either 90 (2286) 40 (1016) 29 (737) 1750 (794) 4 Either 90 (2286) 40 (1016) 29 (737) 1800 (816) NEMA 3R Fixed Bypass 2 600A 120-600V 800-1200A 120-600V 2 Either 91 (2311) 41 (1041) 48 (1219) 1550 (703) 3 Either 91 (2311) 41 (1041) 48 (1219) 1600 (726) 4 Either 91 (2311) 41 (1041) 48 (1219) 1650 (748) 2 Either 91 (2311) 41 (1041) 48 (1219) 1750 (794) 3 Either 91 (2311) 41 (1041) 48 (1219) 1800 (816) 4 Either 91 (2311) 41 (1041) 48 (1219) 1850 (839) Dimensions in Inches (mm) & Approximate Shipping lbs (kg) * Add 6" to width for seismic brackets where required 1 Dual drawout type is field configurable for top or bottom entry 2 Fixed type conduit entry (top or bottom) must be specified at type of order All dimensions and weights are approximate and subject to change without notice and are not for construction use. Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. www.cat-electricpower.com LEHE0062-05 (03-12) LEHE0062-05 5 2012 Caterpillar All Rights Reserved. Printed in U.S.A.