Safety Eyebolt Solutions

Similar documents
Fall Protection Solutions

The Work at Height Safety Association. Guidance on inspecting eyebolts used for personal fall protection purposes

Fall Protection Solutions

Connection Solutions

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

Partitioning & Ceiling Product Information

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

HVU with HAS/HAS-E rod adhesive anchor

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

SERIES NG 1800 STRUCTURAL STEELWORK

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

Machine Screws, Dowel Pins and Hardware

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Bonded Anchors & Mechanical Anchors

PivotLoc Ladder Systems

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Fixed Vertical Access Ladders

MultiPost-AP anchorage device

HUS-HR, CR Screw anchor, stainless steel

Machine devices, jig devices

AMF112 Instruction Manual

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Europeiskt Tekniskt Godkännande European Technical Approval

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Design and Construction of Cantilevered Reinforced Concrete Structures

Saferand easierinstallation

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

AMF112 ( <00>) 13mm (1/2 in.)

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Integrated Manhole Ladder System

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

Samuel Shorty Bunk Bed

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

SECTION GUARDRAILS

ICC-ES Evaluation Report

PC-Concrete Injectable Concrete Anchoring and Repair System

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Hollow or Cinder Block Wall Mount Job Aid

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Residential Deck Safety, Construction, and Repair

Flue Installation. High Efficiency Condensing Boilers

Nuffield and Middleweight Leyland Tractor - 11 inch - Double Clutch Overhaul Part 1 - Clutch Removal and Dismantling

SCAFFOLDING RUNWAY SYSTEM

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

Hilti, Inc South 122 nd East Avenue Tulsa, OK

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

HANDRAIL STANDARDS HANDRAILS AXESS LADDER SYSTEM KICK FLAT SYSTEM OPEN FLOORING

SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS

Guide to working on Public Sewers

Packaged Terminal Air Conditioner Wall Sleeve Installation

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Guide rail bracket (for adjustable heads)

PART E SPECIFICATIONS

Understanding BS EN 771-3: Aggregate concrete masonry units

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

Guidelines for Earthquake Bracing of Residential Water Heaters

SECTION STORM DRAINAGE SYSTEM

How To Test A Wrap N Drain X Dampproofing System

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HUS-HR, CR Screw anchor, stainless steel

Operating Instructions

Guidelines for Earthquake Bracing Residential Water Heaters

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Quick Connect Boxes Inside Gloveboxes

4RU High Density Shelf Installation Instructions

Technical Notes 3B - Brick Masonry Section Properties May 1993

Syphonic Roof Drainage

SAN25 ( <00>)

ATLAS RESISTANCE Pier Foundation Systems

Timber Decks. Technical Note. March 2007

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Original Assembly Guide

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Söll GlideLoc Aluminium Ladders. Vertical fall protection system Certified according to EN 353-1:2002 and CNB/P/11.073

At Ancon, it s all part of the service

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

Rollers. from the UK s largest roller manufacturer. Quality Performance Reliability

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

ARCHITECTURAL. FritsJurgens Pivot Door System Product Range Brochure

for HACA fixed two-rail ladders with / without rear safety guard and fall arrest system

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

HORIZONTAL INSTALLATION

Is your concept unique?

Designed and Engineered to Perform

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Transcription:

Y O U L L N E V E R B E B E T T E R P R O T E C T E D Safety Eyebolt Solutions CE Approved to PPE Directive SUITABLE FOR USE IN TENSION AND IN SHEAR COMPREHENSIVE RANGE OF EYEBOLTS AND ACCESSORIES 0194

The Removable Safety Solution for Fall Protection The KEE I-BOLT range offers a comprehensive selection of Class A1 safety anchors. The RINGANKA portfolio comprises three different lengths of eyebolt suitable for use in a range of materials; brick, concrete, masonry and steel. However, it is important that the correct eyebolt is used to suit the material and that the positioning is determined by a competent person. KEYANKA is a removable eyebolt which is unobtrusive where visual presentation is important. Each of the products has been independently tested at the National Engineering Laboratory and is CE approved to meet the PPE Directive. As a leading supplier of fall protection solutions, Kee Safety offers a range of collective and personal protection products including KEEGUARD, KEE DOME, KEE ANCHOR and KEE ROOFPOINT. Our technical team can offer practical assistance in all aspects of design, installation and compliance with relevant standards for each of the products. Why you need Keyanka By using a correctly installed and tested i-bolt system you can ensure the health and safety of anybody who works in an environment which calls for safe and tested fall protection. The KEYANKA safety eyebolt offers a removable unobtrusive solution to traditional eyebolts for use in more prestigious buildings. The permanently installed grade 316 stainless steel anchor socket is concealed by a flush fitting white plastic cover, which blends in with most interior designs. Equipped with the KEYANKA eyebolt at the end of their lanyard, the operator uses a simple `key action with sprung locking movement, to provide a fast and safe attachment. The eyebolt is able to rotate 180 whilst still attached to the socket to provide the best orientation in event of a fall arrest situation, and can only be removed by five simple, separate but deliberate, sequential movements.

Kee Features of Keyanka Independently tested at N.E.L. (National Engineering Laboratory, East Kilbride, N.B. 0320) Conforms to CLASS A1 EN 795, BS 7883 & ISO 14567 CE Approved to PPE Directive Removable Eyebolt Keyanka in Steelwork Produced from Grade 316 Stainless Steel Flush fitting white plastic cover to blend in with most interior designs Spring loaded locking action Variety of fixing options including concrete, brick, steelwork and cavity walls Optional Stainless Steel or Brass Cap Keyanka in Masonry KEY-CONC Standard KEYANKA socket suitable for resin bonding into minimum 150mm thick concrete ONLY. NO cantilever permitted. KEY-BRICK Standard KEYANKA socket with knurled extension suitable for resin bonding into min. 225mm thick solid masonry. NO cantilever permitted. NOTES: 1 KEY-STEEL must never be used with any thread protruding. 2 When using KEY-EXTSOC extension sockets, the KEYANKA (KEY-STEEL) must be fully screwed in to the collar. 3 KEYANKA and extension sockets should be ordered separately. KEY-THRO Standard KEYANKA socket with additional M12 threaded extender. For use as through bolt fixing (e.g. in cavity walls). NO cantilever permitted.

s for KEYANKA For Brickwork KA-CANT200 50 150 200 KA-CANT225 75 150 225 KA-CANT250 100 150 250 Other Applications KEYANKA bracket to bridge void under floors, above ceilings or behind cladding. For direct axial loading only unless the cladding etc. provides adequate resistance to bending. Use in conjunction with KEY-STEEL, or, if A is greater than 25mm, KEY-ADJ. KEYANKA bridge, sockets and locknuts should be ordered as separate items. For Concrete Embedment KA-CANT175 65 110 175 KA-CANT200 75 120 195 KA-CANT225 100 125 225 KA-CANT270 125 140 265 KA-CANT335 150 160 310 KA-CANT380 175 180 355 KEY-CANT Knurled cantilever socket for use in conjunction with standard KEY-STEEL KEYANKA socket in concrete and masonry. Class A1 Anchor Devices RINGANKA is a comprehensive range of Class A1 safety eyebolts conforming to EN 795, BS 7883 and ISO 14567. RINGANKA eyebolts for use in brick, concrete and masonry have a 16mm diameter unthreaded shank to plug a drilled hole, thus reducing the bending effects which would result in earlier failure during shear loading. These safety eyebolts can be used by fixing to an outside or inside face of a structural element adjacent to a window or other access. They are manufactured from either high tensile carbon steel with a galvanised or plastic-coated finish, or grade 316 stainless steel.

Periodic Inspection BS7883 requires that, wherever possible, all safety anchor devices are removable for periodic inspection. This is easily achieved by using our Knurled Inserts in conjunction with our Resin Capsules. We also offer PPE Warning Discs, which are required for compliance with EN 795. A M12 Female Threaded Knurled Inserts are available in lengths of 76mm, 102mm, 120mm, and 150mm to suit varying installation situations. N.B. 76mm sockets should ONLY be used in DENSE A concrete. B 16mm diameter resin B capsules should be used with M12 Female C Threaded Knurled inserts. C Threaded Connectors to extend eyebolts, for use as Through-Bolts (BS7883). The associated All-Thread is also available. 100mm or 152mm shank length. Used in brick, concrete, etc. with chemically anchored socket and knurled insert. (BS 7883 Fig. 7) Warning Disc This is required to comply with EN 795. Each disc must state whether usage is for Fall Arrest, Fall Restraint, Rope Access or Work Positioning. They are available, printed with your company name (at extra cost). Polythene Sealing Washers are also available. Eyebolt extended with threaded connector and all-thread for use as a through-bolt in solid or cavity wall. (BS 7883 Fig. 9) 75mm shank length used ONLY on steel structures (BS 7883 Fig 9)

Anchor Devices s for RINGANKA For Brickwork A We also offer Anchor Devices for use in dry lined walls or in conjunction with plasterboard, cladding etc. Where the distance from the face of the load bearing structure to the collar of the eyebolt does not exceed 25mm, a spacer sleeve may be placed under the eyebolt collar to provide the necessary support (Fig. A). Where the distance from the face of the load bearing structure to the collar of the eyebolt exceeds 25mm, special cantilever sockets are available. Where the distance to be bridged exceeds 175mm (100mm in brick) special advice should be sought (Fig. B). Embedment Embedment CANTI200 50 150 200 CANTI225 75 150 225 CANTI250 100 150 250 For Concrete CANTI175 65 110 175 CANTI200 75 120 195 CANTI225 100 125 225 CANTI270 125 140 265 CANTI335 150 160 310 CANTI380 175 180 355 General Requirements for Anchor Devices 1 Maximum permitted in-service force = 6kN (design capability = 10kN as per EN 795); i.e. all users must be protected by the provision of an energy absorber to EN 355 2 Load bearing structures and chemical fixings must be capable of withstanding a 10kN pull-out force 3 Each individual installed anchor device must be subjected to a 6kN pull-out force (as per BS 7883) 4 It should be noted that, when installed into materials of less than 20Nmm 2 compressive strengths, there may be local crushing/ compacting around the drilled hole at fall arrest. B Kee Safety Ltd Cradley Business Park Overend Road, Cradley Heath West Midlands B64 7DW Tel: 01384 632188 Fax: 01384 632192 Email: sales@keesafety.com Web: www.keesafety.co.uk KEE i-bolt, KEYANKA, RINGANKA, KEE GUARD, KEE DOME, KEE ANCHOR and KEE ROOFPOINT are trademarks of Kee Safety Limited. Whilst every effort has been made to ensure the accuracy of the information contained in this brochure Kee Safety Ltd cannot be held responsible for any errors or omissions. Kee Safety Ltd reserves the right to alter or withdraw products without prior notice. Kee Safety Ltd accepts no responsibility for any loss or damage arising from improper use of their products. 2008 Kee Safety Ltd. All Rights Reserved. ib/ses_uk_v2/1008