Internet-Accessible Power Monitoring & Control Systems



Similar documents
SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

GEH g POWER LEADER Power Management Control System Network Architecture Guide

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Access valuable energy and power information from your system

Logic, IEC61850 System Configuration and Real-Time Monitoring. Security Auditing, Device and Asset Health Reporting and Fault Data Retrieval


PLCs and SCADA Systems

Power network telecommunication

Monitoring & Control of Small-scale Renewable Energy Sources

Electrical Network Management System

EnerVista TM Viewpoint Monitoring v7.10

Chapter 5. Data Communication And Internet Technology

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

SCADA Questions and Answers

EnerVista Viewpoint Monitoring

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

Network and Facility Management: Needs, Challenges and Solutions

Process Control and Automation using Modbus Protocol

Communicate and view data from meters with one simple device

Networks. The two main network types are: Peer networks

EUCIP - IT Administrator. Module 3 LAN and Network Services. Version 2.0

Local-Area Network -LAN

IP Networking. Overview. Networks Impact Daily Life. IP Networking - Part 1. How Networks Impact Daily Life. How Networks Impact Daily Life

Computer Networks. Definition of LAN. Connection of Network. Key Points of LAN. Lecture 06 Connecting Networks

A Proposed Integration of Hierarchical Mobile IP based Networks in SCADA Systems

Wireless Links - Wireless communication relies on radio signals or infrared signals for transmitting data.

Power & Environmental Monitoring

Substation Automation Systems. Nicholas Honeth

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Video Security Systems Designer

Page 1 of 7. Computer Networking

FOUNDATION Fieldbus High Speed Ethernet Control System

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

EnerVista Viewpoint Monitoring

Electrical Monitoring and Control System Solution. Guideform Specification

1 Data information is sent onto the network cable using which of the following? A Communication protocol B Data packet

5 Data Communication and Networking

Networking Devices. Lesson 6

Square D Model 6 Motor Control Centers

Semaphore T BOX Applications in Data Center Facilities

Wireless Communications for SCADA Systems Utilizing Mobile Nodes

HMS Industrial Networks. Putting industrial applications on the cloud

Substation Automation and Smart Grid

Introduction To SCADA and Telemetry

The OSI and TCP/IP Models. Lesson 2

You were seeking a protocol translator. Eaton delivered a vital data flow processor.

Copyright 2014 GE Multilin Inc. All rights reserved. EnerVista Viewpoint Monitoring Quickstart Guide for version 7.1x. EnerVista, Viewpoint

Telecommunications, the Internet, and Wireless Technology

ION Tips and Tricks. Q&A Session PowerLogic ION Users Conference 2009

Power Monitoring for Modern Data Centers

Modbus and ION Technology

Networking Basics for Automation Engineers

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist

HMS Industrial Networks

EDI Distributor Control Interface Wiring and Setup Instructions

Network Design. Yiannos Mylonas

Carrier Ethernet: New Game Plan for Media Converters

Chapter 2 TCP/IP Networking Basics

IEC 61850: Communication Networks and Systems in Substations

INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo

IT Data Communication and Networks (Optional)

DATA COMMUNICATION BETWEEN PROGRAMMABLE LOGIC CONTROLLERS IN THE INDUSTRIAL DISTRIBUTION APPLICATIONS

TYLER JUNIOR COLLEGE School of Continuing Studies 1530 SSW Loop 323 Tyler, TX

JOB READY ASSESSMENT BLUEPRINT COMPUTER NETWORKING FUNDAMENTALS - PILOT. Test Code: 4514 Version: 01

Industrial Communications Training

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

A DNP3 Protocol Primer

Student Halls Network. Connection Guide

Alliance System Ordering Guide

INTERIM MARKET DOCUMENT CHANGE

CompTIA Network+ (Exam N10-005)

Manage Utility IEDs Remotely while Complying with NERC CIP

Chapter 4 Connecting to the Internet through an ISP

PowerLogic ION Enterprise 5.6

CCNA 1: Networking Basics. Cisco Networking Academy Program Version 3.0

Introduction to Network Management

1 Which network type is a specifically designed configuration of computers and other devices located within a confined area? A Peer-to-peer network

NRG Energy Center Minneapolis

1.5 Distributed Systems

Comprehensive Asset Performance Management. Power Transmission and Distribution

Monitoring solar PV output

Synapse s SNAP Network Operating System

Telecommunications, Networks, and Wireless Computing

DataSocket Simplifies Live Data Transfer for LabVIEW

SCADAvantage Network Topology System software products

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Computer Networking. Definitions. Introduction

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

CNG IN A BOX: Cloud Based Enterprise Historian w\dash Boarding Solution for CNG Fueling Stations

Network Management System (NMS) FAQ

Education & Training Plan IT Network Professional with CompTIA Network+ Certificate Program with Externship

WISE-4000 Series. WISE IoT Wireless I/O Modules

Transcription:

Internet-Accessible Power Monitoring & Control Systems By GE Specification Engineers Keith B. Brock, P.E. Robert P. Hansen, PhD, P.E. Introduction Accessing electrical system information from any location allows the system manager to provide quicker command and control of intelligent devices. At the dawn of these devices, the manager could only access system parameters at the distribution location. As data communication techniques evolved, devices could be monitored anywhere within the building or within closely knit campus settings through proprietary protocols. Now, the Internet allows real-time access anywhere on the globe through open protocols. Today, the following functions can be performed routinely and enhanced via the Internet: Power Management Minimize downtime and reduce costly equipment damage Alarm and event management Improved predictive maintenance notification Increased safety by remote monitoring and device control Power quality and waveform capture Energy Monitoring Utility billing auditing Demand management The purpose of this article is to describe the available architectures that support these functions over the Internet: the hardware that allows the networking of intelligent electronic devices and the related software that manages the above functions. Terminology Ethernet: The industry-standard communication network used in local-area networks of PCs and now broadly called the Internet or the Web. Ethernet Gateway: Translates RTU to an Ethernet TCP/IP network.

HMI: The Human Machine Interface is the client software interface through which the user views metering information, configures IEDs and issues commands. IEDs: Intelligent Electronic Devices are devices that control, protect and monitor the electric distribution systems: Electronic trip units on breakers Electronic power meters Protective relays Programmable logic control devices Meter Configuration: This software is used to configure the meter for proper operation. Concentrator: Translates vendor specific legacy protocols to RTU. Remote Terminal Unit (RTU): An industry-standard, open protocol typically used in a close-knit network above the proprietary protocols. PMCS: Power Management and Control System. The term will be used in the broadest context to include the hardware and software that enables a range of capabilities from simple power monitoring to a fully featured energy management and power quality system. PMCS DDE Server: Power Management and Control System Dynamic Data Exchange server responds to requests from the Host PC to route data, to and from devices, by an identifying data tag. Often error detection and correction are performed at this layer. Protocols: A generic term used to identify communication methods. It can be loosely described as the language of packaging binary data. Open protocols are available universally and are often the standard while closed protocols are proprietary and unique to each manufacture. RS485: The network that communicates in the RTU protocol. Server: Software that provides the centralized interface to connected devices issuing commands and requesting data. This is also called the host. TCP/IP: Terminal Control Protocol over Internet Protocol. The industry-standard, open layered protocol that accesses the Internet where every node has a unique IP address. TCP/IP is buried in most operating systems including Unix, Mac OS X and current Windows versions. Note: TCP/IP is used here to generalize the suite of Internet protocols bearing different names.

Network Architecture The purpose of PMCS is to exchange information and commands between IEDs and the system manager. The devices and Host PC must be able to interface with the data communications system, send and then reconstruct the original signal as accurately as possible in a particular protocol. The combination of IEDs, networks and protocols are numerous but easy to manage. IEEE 802.3 was the initiating standard for Internet communication now moving to the IEC 61850 standard specifically for substation automation. Intelligent Electronic Devices At the IED level, time-varying signals such as current, voltage, etc, are sampled and converted into a digital representation as a sequence of bits over conductors, modulated light or radio signals. The input/output transmitter presents these 1 s and 0 s as voltage shifts transmitted over the communication network in the appropriate protocol. Protocols For the purpose of this discussion, there are three protocols -- arranged from the earliest to present: Legacy Protocols unique and closed for each PMCS manufacture (Comment, SEL, INCOM, PROFIBUS, etc) RTU (RS485 network) TCP/IP (Ethernet 10/100/1000Base-T network) Networks The physical network is primarily wire conductor based: Ethernet LAN, Internet (TCP/IP protocol) Media X Base-T (twisted pair CAT 5) X Base-FL (fiber optic) X = Mbits/sec RS485 RTU protocol Media two-wire twisted pair, shielded cable Legacy Proprietary protocol Media two-wire twisted pair, shielded cable Networks can also be radio, microwave or satellite based. The only difference is the methods of sampling, modulation (coding) and demodulation (encoding) signals. Below, Figure 1 is an illustration of the various networks discussed combined to allow all IEDs accessibility over the Internet:

Figure 1. Multi-Protocol Architecture Ethernet IED IED: identical baud rates Legacy A proprietary IED Legacy B proprietary RS 485 RTU Ethernet Hub Ethernet Gateway Ethernet TCP/IP Concentrator A Concentrator B Legacy A network Legacy B network The red and blue networks represent two different proprietary protocols where each signal is translated into RTU by the Concentrators. The baud rates of every IED and both manufactures to Ethernet Concentrators must be identical. The protocol is then translated to TCP/IP at the Ethernet Gateway. All the Ethernet TCP/IP devices are gathered at the Ethernet Hub and present to the Internet by one of many providers. Host PC The host PC above connects to the Ethernet hub via the Internet (shown as a gray dashed-line). The host PC is equipped with an Ethernet Card for Internet communications. The PC location is unrestricted, provided an Internet connection is available and also assuming IT security regulations allow access from outside of the

facility. However, with proper password and firewall protection, the system can be made secure while providing the system manager with the overwhelming advantage of having instant access to devices from any location. A simplified option is available when remote monitoring of meters is the objective, especially significant for L.E.E.D. certification (Figure 2). The Ethernet hub accepts the connections from one or multiple Ethernet meters and gateways. Additional meters may be daisy-chained to the Ethernet gateway (Figure 2a) or a proprietary network through a concentrator and gateway (Figure 2b). This architecture minimizes both hardware and software requirements when only meters need to be accessed. The Ethernet meter may also contain an embedded web server, in which case the meter acts as the host and the PC uses a web browser as the HMI without PMCS software. Figure 2. Metering Only Architectures a) b) Ethernet Hub Ethernet Hub Ethernet Meter/s Ethernet Meter/s Ethernet Gateway Ethernet Gateway Meters Concentrator Legacy Meters

Software The PMCS software at the operator level is the heart of the system. It functions as the HMI at the highest layer, but also performs many tasks (DDE server functions) in the background related to orchestrating the gathering and distribution of information. While numerous options and accessories for PMCS software are available, the market generally offers a range of basic through premium software products. The basic PMCS software is intended for smaller networks of IED s. This software costs less but does not offer high-end features such as energy management and limits the number of clients connected to the host. The premium PMCS package will provide the full range of monitoring, control, energy management and power quality features. It is intended for larger numbers of IEDs and will allow many more clients to access the system. The difference in cost between the basic and premium PMCS products is significant enough to warrant a careful review of the requirements of the project. The PMCS HMI is the graphical user interface that provides the operator with a portfolio of features that makes complex tasks manageable. These include: IED management Initial connection to, and set-up of, networked IEDs Adjust parameters as the electrical environment changes Monitoring of metered data through pre-configured screens Voltage, current, power, energy, power factor, frequency, etc Viewing of power quality events Captured waveforms, total harmonic distortion, trending, etc Time-stamped events Monitoring system status Editing and viewing of single-line diagrams Breaker positions Alarm settings and annunciation Predictive maintenance Report generation Management of energy usage Energy and demand data Cost allocation Reducing peak demand through load shedding The HMI software is installed on each computer that will view the data. The PC that hosts the network of IEDs is the PMCS server. It is possible to have one computer to act as both a client and a host. When the host and client are on separate computers; the client does not have direct connections to the IEDs -- information is sent to the client by the host.

If the requirement is to integrate PMCS data into higher-level monitoring, automation, or control systems, then products exist to make PMCS data available to other non- PMCS applications. An example of this requirement would be to incorporate electrical distribution events into a facility-wide data logger. An integrating software using OLE (Object Linked Embedding) for Process Control or OPC for short will fill this need. OPC server software can be purchased as an option to a basic PMCS software package or may be integral to the premium versions. Conclusion From simple daisy-chained electronic meters to advanced PMCS with energy management and power quality features, the system designer needs to tightly define the requirements of the project and allow for future expansion. Clearly, specify all metered functions, any throw-over or load-shedding schemes and identify any requirement to interface with an existing PMCS. Also, indicate which feeders and other downstream equipment requiring monitoring and control. The software will allow for ease of set-up and provide future users a simple platform to operate and monitor the system. Most software products provide a plug-and- capability so field changes are easily performed. Along with clearly specifying play the IEDs and functions, care must be taken to select the proper level of software capabilities. Therefore, IEDs that operate on a variety of protocols may be combined into an Ethernet network using readily available components. With the proper coordination of architectures and software selection, diverse systems can be managed from any location connected to the Internet. References Marilyn Self, OPC The Enabling Software, Electrical Specifier Link, Summer/Fall 2005, http://www.geindustrial.com/newsletter/oct05.htm GE Multilin, PMCS 6.14 Read this Book First, May 2005 GEH-6514, http://www.geindustrial.com/products/manuals/pmcs/geh-6514-615.pdf POWERLEADER Power Management Control Systems Network Architecture Guide, 1999, GEH-6502 http://www.geindustrial.com/products/manuals/geh-6502-611.pdf Reference Guide: Protection, Control, Metering, Communications Instrument Transformers, 2007/2008 http://www.geindustrial.com/pm/about/whoweare.pdf