DAR remote power feeding

Similar documents
Original instructions Tina 3A/Aps Adaptor unit

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

IO-DIM6 6-Channel, Digital to Analogue Converters

Tina 2A/B Adaptor unit

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

Modular I/O System Analog and Digital Interface Modules

EGSTON Standard E2xFxWx 12W

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Duct Humidity Transmitter

Power Supplies 3. SDN-P DIN Rail Series

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

RIELLO ELETTRONICA. Master HP

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Antec TruePower User's Manual

PCS0100en Persy Control Services B.V. Netherlands

Phase Modular Finally the benefits of Modular ups are for all

Series AMLDL-Z Up to 1000mA LED Driver

Rack mounted telephone- and leased line modem for industrial applications

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

User manual Rev. 1.2 (17/04/2015)

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

M-series FOUNDATION Fieldbus I/O

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Thyristor-controlled power supplies and battery chargers

Redundancy Module QUINT-DIODE/40

I STAR COMPUTER CO., LTD

IMR 6000/10../20../30

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

AC3200 INTELLIGENT BROADBAND AMPLIFIER

How To Build A Low Voltage Capacitor Lvcp

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Terminal and Dimension

DeltaV SISnet Repeater

3-phase, bidirectional energy meter

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

Powerline 1200 User Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Operating Manual UWAPS-TINY Series

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

CONFIGURABLE SAFETY RELAYS

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

NEW. EVEN MORE data acquisition and test stand automation

Data Sheet FUJITSU Storage ETERNUS LT20 S2 Tape System

Application Note TMA Series

ZC-24DO CANopen I/O Module: 24 Digital Outputs

GSR 12/24V. GSR 12/24V Technical manual Model 12/24

L5354 ControlNet Communications Interface

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Telephone- and leased line modem for industrial applications TD-36

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Indoor / Outdoor Antenna

Electronic Control Devices The European Product Catalogue 2007

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

How To Use The Vacon 0 Machinery

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

Quick Connect. quick - simple - efficient.

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Guide to the electrical parameter classifications of IEC and IEC safety standards

Infinity C DC to DC Power System

AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN

NC-12 Modbus Application

2-Pair HDSL1 Adtran Fiber Optic Link System

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

User s Manual Before using the inverter, you need to read and save the safety instructions.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Cisco Redundant Power System 2300

WD-AMX Water Detection Controllers

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

SAFETY MANUAL SIL RELAY MODULE

3500/62 Process Variable Monitor

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

IO-RM3 3-Stage Relay Module

SAFETY MANUAL SIL Switch Amplifier

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Safety technique. Emergency stop module BO 5988 safemaster

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Transcription:

Strowger Inc. 1 DAR remote power feeding Digital ADSL Regenerator: remote power feeding specification WHITE PAPER September, 2012 DAR remote power feeding [8]

Strowger Inc. 2 Contents Contents...2 Contents...2 1 General...3 2 Remote power...4 3 Power consumption...4 4 Harmonizing with standards...5 5 User interface...6 6 Mechanical parameters...6 7 Environmental conditions...6 8 Device reference...7 Figures Figure 1. Basic configuration...3 Figure 2. RPF...7 Release Date Comments 09-2012 Remote power feeding solution at DAR DAR remote power feeding [8]

1 General The DAR is a remotely installed active unit which is able to regenerate an ADSL signal and makes the traditional ADSL coverage longer. The unit can be used for bandwidth increase on fixed exchange subscriber loops (pe.: IPTV range extension). The unit is powered remotely from the central office over the copper pairs by a Remote Power Feeding (RPF) card. The RPF is a rack-type version where the SBR sub-rack provides the connection facilities and the 48/60 Vdc local power to the unit. One card has 4 separate power interfaces towards the remote areas. The target application of this device is to provide power remotely to those areas where solving the local power source is difficult. The unit is universal and can be used with Strowger s product or other third party equipment which require this range of power. Possible applications: powering and supervising DAR units (see document GenDesc DAR v3.1), powering Wi-Feeder including the xdsl data link (see document GenDesc WF v1.0), general power source to any third party device. The basic configuration of the system is shown below: Figure 1. Basic configuration This is installed in Strowger s sub-rack at the telephone Exchange (48 Vdc, external power lines, xdsl lines). Note: The available ADSL filtering and the monitoring EOC channels are optional features, generally this is not needed for simple remote powering applications.

2 Remote power All remote power feeding sources meet the safety requirements of EN 60950-1 and EN 60950-21 with the following specification: circuit category: remote feeding voltage: output capacity: current limiting: unbalance shut-down: RFT-V (optional RFT-C) max ± 160 Vdc, software selectable 20 μf line to line 57 ± 1 ma 1.5 ma to ground During the remote power feeding period the sub-rack continuously measures the output voltage and the unbalance of the line to the ground. In the case an unbalance is detected for more than 100 ms or an overload or line interruption for more than 100 ms the sub-rack switches off the power. After 10 sec from switching off, the system re-starts with the initialization phase. The remote power feeding rack is permanently switched off within 200 ms in the case an internal hardware fault is detected (over voltage, over current). The RPF card supports a voltage level safety test when no connected items are at the end of the lines. This test voltage level is 50 Vdc to protect the technicians during installation (WAKE UP feature). Inversion of the voltage polarity of the power lines has no impact on the operation of the system. 3 Power consumption The RPF module requires nominal 48/60 Vdc power supply input voltage. The power supply interfaces are built according to ETSI EN 300 132-2 standard with the following parameters: input voltage: 40.. 76 Vdc max. power consumption: 50 W max. power dissipation: 20 W The above parameters are measured in the worst case scenario when the system has been connected over 4x 1300 Ω loops and the output powers are at the maximum level.

4 Harmonizing with standards The remote power feeding solution used in the RPF-DAR system fulfills these standards: IEC-60950-1 (2001, 2006) Information Technology Equipment Safety / General IEC-60950-21 (2002-12, 2003) Information Technology Equipment Safety / Remote Power Feeding ITU-T K.50 (02/2000) Safe limits of operating voltages and currents for telecommunication systems powered over the GR-1089, Issue 6 Electromagnetic Compatibility and Electrical Safety Generic Criteria for Network telecommunications Equipment (05/2011) published by Telcordia network. Operator must reduce the operating voltage to +/- 140 Vdc to comply with this standard. The above internationally accepted standards recognize an RFT-C power architecture with a 60 ma current limit as being safe and can be handled (installed, operated) without special precautions. To meet the GR-1089, some configuration is needed. GR-1089 defines 3 different levels for the remote power feeding based on the access of the voltage and current levels: Class A1 is the most stringent and applies to areas which may be contacted by the general public, which is assumed to be unfamiliar with electrical hazards. Class A2 permits higher limits and covers those areas where non-specialized telephone company employees may have contact. Class A3 is the highest allowable level for voltages which may be contacted barehanded. It applies to those areas available only to telephone company technical personel familiar with the appropriate precautions, and applies to HDSL circuits and equipment. The RPF-DAR system due to its application purposes should be handled by Class A2 personel. The specification on paragraph 7.2.1.3 sets limits on both voltage and current. At 140 Vdc or less there is no limit on current. Between 140 and 200 Vdc current may not exceed 10 ma. All the voltages are measured with respect to the ground. GR-1089 allows two separate compliant voltages, one at -140 Vdc, the other at +140 Vdc, providing twice the voltage for powering the loop. This voltage level is already enough to power remote equipment on longer loops. In RPF-DAR system the voltage level is adjustable up to +/-160 Vdc. To meet the GR-1089 Class A2 requirements simply reduce the voltage level to +/-140 Vdc.

Because the current is always limited to less than 60 ma in accordance with IEC and ITU-T recommendations, the RPF-DAR power architecture meets international safety standards for telecom technicians to handle at the default power levels. If you feel you must comply with the more restrictive GR-1089 Class A2, please be sure to reduce the power levels to +/-140V. 5 User interface The RPF card provides 4 independent power interfaces. Status LEDs STATUS/green ON power on normal state OFF channel is OFF flash/1 Hz wakeup state System LEDs CPU/green ON power on normal state OFF power problem ERR/red ON power problem OFF normal state 6 Mechanical parameters The mechanical properties of the units are as follows: Dimension (H x W x D): Weights: Installation: 262 x 30 x 225 mm 550 g SBR-14 sub-rack designed by Strowger 7 Environmental conditions The RPF module was designed and tested to meet the following environmental requirements of ETSI standards: Operation: ETSI ETS 300 019-1-3 class 3.1 Storage: ETSI ETS 300 019-1-1 class 1.2 Transport: ETSI ETS 300 019-1-2 class 2.2 Operational temperature: +5.. +40 C

Relative humidity: Protection: 0.. 95 % non-condensing IP20

8 Device reference The RPF unit is a plug-in module to the available sub-racks. 14 modules can be installed in the subrack. The solution yields up to 56 remote power interfaces on one SBR-14. Figure 2. RPF