Carrier Gas Selection for Capillary Gas Chromatography

Similar documents
Diffusion and Fluid Flow

Addressing the World Helium Shortage For Gas Chromatography

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Hydrogen as an alternative to Helium for gas chromatography.

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

23 The Thermal Conductivity Detector

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

The Use of Hydrogen Carrier Gas for GC/MS

Fractional Distillation and Gas Chromatography

Gas Chromatography Liner Selection Guide

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Separation of Amino Acids by Paper Chromatography

Analyzing Small Molecules by EI and GC-MS. July 2014

The van Deemter Equation:

AN INTRODUCTION TO HEADSPACE SAMPLING IN GAS CHROMATOGRAPHY FUNDAMENTALS AND THEORY. Andrew Tipler

Background Information

Gas Separations: A Comparison of GasPro and Aluminum Oxide PLOT Columns for the Separation of Highly Volatile Compounds

Retention Parameters in Column Chromatography

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Gas Chromatography. Gas Chromatograph

SUCRALOSE. White to off-white, practically odourless crystalline powder

Theory and Instrumentation of GC Introduction

The Theory of HPLC. Gradient HPLC

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Expectations for GC-MS Lab

Gas Laws. The kinetic theory of matter states that particles which make up all types of matter are in constant motion.

Clarus 580 Gas Chromatograph

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13

Mass Spectrometry. Fundamental GC-MS. GC Considerations

Paul Clements, SpR in Anaesthetics, Hope Hospital, Salford, UK. Carl Gwinnutt, Consultant Anaesthetist, Hope Hospital, Salford, UK.

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Opiates in Urine by SAMHSA GC/MS

Temperature. Number of moles. Constant Terms. Pressure. Answers Additional Questions 12.1

CHEMISTRY GAS LAW S WORKSHEET

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

CHAPTER 12. Gases and the Kinetic-Molecular Theory

Chapter 2 Theory of Gas Chromatography

Pesticide Analysis by Mass Spectrometry

Handling Gas: Cylinders vs Gas Generators

A drop forms when liquid is forced out of a small tube. The shape of the drop is determined by a balance of pressure, gravity, and surface tension

Chapter 5 GLC. Chapter 3 Multiclass MRMs. Chapter 4 Selective MRMs

Exam 4 Practice Problems false false

Bulletin 864A. Simulated Distillation of Petroleum Products by Packed Column and Capillary Column GC

GC/MS Considerations for Fracking Gases and Water. Dr. Harold McNair Virginia Tech Blacksburg, VA.

AUTOMATIC CHANGEOVER MANIFOLD Series 915

= atm. 760 mm Hg. = atm. d. 767 torr = 767 mm Hg. = 1.01 atm

Thermal Conductivity Detector

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Split / Splitless Injection for Capillary GC

Phys222 W11 Quiz 1: Chapters Keys. Name:

CHROMOCTANE O N LINE ANALYZER

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

KINETIC MOLECULAR THEORY OF MATTER

Shimadzu Simulated Distillation Gas Chromatograph System C184-E030

Solid Core Technical Compendium

SULFUR COMPOUNDS IN PETROLEUM HYDROCARBON STREAMS

MINERAL OIL (MEDIUM VISCOSITY)

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

SUGAR ESTER SYNTHESIS IN HIGH PRESSURE ACETONE-CO 2 SYSTEM

Determination of polyols derived from sugars and residual sugars found in dry wines by means of gas chromatography (Resolution Oeno 9/2006)

ß-CYCLODEXTRIN SYNONYMS

C184-E014D GC Shimadzu Gas Chromatograph System

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Lecture Notes: Gas Laws and Kinetic Molecular Theory (KMT).

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Gases. States of Matter. Molecular Arrangement Solid Small Small Ordered Liquid Unity Unity Local Order Gas High Large Chaotic (random)

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

10.7 Kinetic Molecular Theory Kinetic Molecular Theory. Kinetic Molecular Theory. Kinetic Molecular Theory. Kinetic Molecular Theory

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

a) Use the following equation from the lecture notes: = ( J K 1 mol 1) ( ) 10 L

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

GOED VOLUNTARY MONOGRAPH (v. 4)

CHLORINATED BIPHENYLS IN OPEN OCEAN WATERS: SAMPLING, EXTRACTION, CLEAN-UP AND INSTRUMENTAL DETERMINATION

GC Troubleshooting 10. How to use this Troubleshooting Help system GC Troubleshooting - Top Level Generic problem descriptions...

1. Standard conditions are in. Hg (760 mm Hg, psia) and 68 F (20 C).

Practice Test. 4) The planet Earth loses heat mainly by A) conduction. B) convection. C) radiation. D) all of these Answer: C

THE KINETIC THEORY OF GASES

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES

THE HUMIDITY/MOISTURE HANDBOOK

7. Gases, Liquids, and Solids 7.1 Kinetic Molecular Theory of Matter

User Guidelines & Standard Operating Procedure for the Varian 3800 GC

Transcription:

Carrier Gas Selection for Capillary Gas Chromatography Len Sidisky, Greg Baney, Katherine Stenerson, and James L. Desorcie Supelco, Div. of Sigma-Aldrich, Bellefonte, PA 16823 USA T411126 www.sigma-aldrich.com

Abstract Nitrogen, helium and hydrogen are the most commonly used carrier gases for capillary gas chromatographic analyses. We will compare the performance of these gases focusing on their affects on the speed of analysis, selectivity, resolution, sensitivity, and safety of use. Theoretical and practical examples will be presented. 2

Introduction Carrier Gases for GC The carrier gas (mobile phase) for gas chromatography should be an inert gas that does not react with the sample components. The GC carrier gas should contribute minimally to the partitioning process. This differs from the mobile phase in liquid chromatography. In GC the carrier gas is simply stated as just a carrier to transport the vaporized solute molecules through the column during the partitioning process. 3

Carrier Gases for GC (contd.) Carrier gases are compressible gases that expand with increasing temperature. This results in a change in the gas viscosity. The selection and linear velocity of the carrier gas will affect resolution and retention times. Carrier gases should be inert to the stationary phase and free of detectable contaminants. 4

Efficiency Effects of Carrier Gases Carrier gas linear velocity plays a significant role in the resulting efficiency of a chromatographic system. The optimal carrier gas linear velocity is characteristic for each gas. van Deemter curves and Golay Plots are used to demonstrate optimal carrier gas linear velocities. van Deemter plots are used for packed columns since the A term for eddy diffusion is present. Golay plots are used for capillary columns (open tubular) and the A term is dropped. 5

van Deemter Plot H Average Linear Velocity 6

Simplified van Deemter Equation H=A + B/µ + cµ HETP has also been used for H A is the Eddy Diffusion term B is the Molecular Diffusion term C is the Resistance to Mass Transfer Term µ is the carrier gas linear velocity 7

Typical Golay Curves 8

Rate of Band Broadening Capillary Columns - Golay: H 2D g 2kd f 2 31 k) 2 Dliq r 2 1 6k 11k 2 24D g 1 k 9

Retention Time Effects Analyses can be either isothermal or temperature programmed runs in GC. The carrier gas linear veloctiy can influence the overall time of analysis and the efficiency of the separations. The following equation demonstrates the affect of linear velocity on retention time. t r = L (k+1) µ where t r = retention time L = column length k = retention factor µ = carrier gas linear velocity 10

SUPELCOWAX 10 Isothermal 25 cm/sec. Helium Carrier k (C20)=6.10 CE=86% N=119924 C20 0 2 4 6 8 10 12 14 16 Time (min) 11

SUPELCOWAX 10 Isothermal 50 cm/sec. Helium Carrier k (C20)=6.10 CE=43% N=60633 C20 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Time (min) 12

SUPELCOWAX 10 Isothermal 50 cm/sec. Hydrogen Carrier k (C20)=6.03 CE=85% N=114344 C20 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Time (min) 13

SUPELCOWAX 10 Isothermal 10 cm/sec. Hydrogen Carrier k (C20)=6.03 CE=50% N=70223 C20 0 10 20 30 Time (min) 14

The four figures demonstrate the affect of carrier gas linear velocity on the time of analysis and the efficiency of the chromatography. Helium carrier gas is near optimum linear velocity at 25 cm/sec. as shown in the first figure. The analysis time is approximately 14 minutes and the % coating efficiency (CE) is 86%. When we double the helium carrier gas velocity to 50 cm/sec. we now decrease the analysis time to about 7 minutes and also see a significant reduction in the column efficiency to about 43%. This is due to operating the carrier gas on the far right side of the Golay plot. This demonstrates the mass transfer term affect on the column performance. A similar effect is demonstrated for the hydrogen carrier gas analysis. Hydrogen is optimum near 50 cm/sec. as shown in the third figure. When we lower the hydrogen carrier gas linear velocity to approximately 10 cm/sec. we see the corresponding increase in the retention time and a large drop off in the efficiency of the column as shown in the fourth chromatogram. This demonstrates the effect of operating on the far left side of the Golay plot where the molecular diffusion term is the major factor. 15

Linear Velocity/Flow Control Linear velocity or flow can either be run in a constant pressure or constant flow mode. This is important in temperature programmed analyses. In the constant pressure mode, the column head pressure is set at a temperature and the pressure remains constant throughout the analysis. This can result in linear velocity changes especially over a wide temperature programming range. In the constant flow mode, the column head pressure will change throughout a temperature programmed analysis in order to keep the carrier gas flow at a constant flow rate. 16

Carrier Gas Viscosity Carrier gas viscosity is a temperature dependent parameter. As temperature increases, the viscosity of the gas increases. When using a constant pressure mode for carrier gas and temperature programming, the viscosity of the gas will increase and the average linear velocity will decrease. 17

Carrier Gas Viscosity (µp) Temperature C Nitrogen Helium Hydrogen 0 167.36 186.62 83.99 20 175.03 194.60 87.64 40 182.71 202.59 91.30 60 190.38 210.57 94.95 120 213.41 234.53 105.02 160 228.76 250.50 113.23 200 244.11 266.48 120.53 240 259.46 282.45 127.84 260 267.14 290.43 131.5 280 274.81 298.42 135.15 300 282.49 306.41 138.81 Adapted from Ettre & Hinshaw, Basic Relationships of Gas Chromatography, 1993, Advanstar. 18

Carrier Gas Viscosity & Temperature Viscosity (µp) 350 300 250 200 150 100 50 0 Helium Nitrogen Hydrogen 0 50 100 150 200 250 300 350 Temperature ( C) 19

Carrier Gas Viscosity & Temperature (contd.) Linear Velocity (cm/sec) 60 50 40 30 20 10 0 Hydrogen Helium Nitrogen 0 100 200 300 400 Temperature ( C) 20

Carrier Gas Viscosity & Temperature (contd.) Hydrogen Experimentally determined t R & µ Equity -1 40 C t R = 1.025 minutes and ū = 48.78 cm/sec. 300 C t R = 1.553 minutes and ū = 32.20 cm/sec. Linear velocity (µ) change was 34.0% over a 260 ºC temperature window 21

Bacterial Acid Methyl Esters 25 cm/sec. Hydrogen Equity-1 0 10 20 Time (min) 22

Bacterial Acid Methyl Esters 50 cm/sec. Hydrogen Equity-1 0 2 4 6 8 10 12 14 16 18 Time (min) 23

Run Conditions column: Equity-1, 30 m x 0.25 mm I.D. x 0.25 µm oven: 150 C (4 min.), 8 C/min. to 250 C (10 min.) inj.: 250 C det.: FID, 250 C carrier gas: hydrogen as listed injection: 1 µl, 100:1 split liner: 4 mm I.D. cup style sample: 10 mg/ml bacterial acid methyl ester standard in methyl caproate, Cat. No. 47080-U 24

Linear Velocity & Retention Time t R is inversely proportional to ū double ū, cut t R in half for an isothermal analysis. Retention time in temperature programmed analyses is primarily dependent on programming rate. Viscosity impacts the linear velocity of the carrier gas over a wide temperature programming range and can change peak elution patterns. Constant flow mode can be used to minimize the changes in carrier gas viscosity for temperature programmed analyses. 25

Safety Concerns with Carrier Gases Safety concerns with nitrogen and helium are minimal. Both are compressed gases and can cause asphyxiation if rapidly released in a small confined area. Hydrogen is combustible over a concentration range of 4% to 74.2% by volume. Combustion can occur due to rapid expansion of the gas from a high pressure cylinder. Hydrogen is a highly diffusive gas in air. Hydrogen generators and EPC typically have automatic built-in shut down devices when a leak is detected. 26

Summary Carrier gases in gas chromatography are used to move the solutes through the column. Helium, hydrogen and nitrogen are the most widely used gases. Nitrogen provides the best efficiency but is extremely slow. Helium provides good efficiency and analysis times but is an expensive choice for a carrier gas. Hydrogen provides the fastest analysis times over a broad linear velocity range. Temperature programming changes the viscosity of a carrier gas resulting in a decrease in linear velocity/flow over the programmed range when run in a constant pressure mode. Hydrogen is the best choice for capillary GC due to diffusivity and a broad working range as long as safety concerns and proper controls are in place. 27