Diesel-Hydraulic Driven Pumping Unit for Firefighting

Similar documents
Your Partner for Concentrated Solar Power Generation The Heart of Your Process

Fire Protection Pumps

Vertical Pumps for the Oil & Gas Industry

C18 ACERT Fire Pump Tier bkw/ rpm

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Marine Generating Sets 3.7 to 50 kva

Diesel Engine Driven Generators Page 1 of 6

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

N/NH Truck-mounted fire pump series

Para la protecció n de la vida y las propiedades, las Bombas de Incendio AC ofrece paquetizados que satisfacen cada necesidad.

FIRE-FIGHTING DESIGN BRIEF REPORT

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Flex separation systems, S-separators

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

LEISTRITZ PUMPEN GMBH. Leistritz Screw Pumps & Systems. Cargo and Liquid Handling

Kobelco Extended Warranty Program.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

ECOCIAT. Domestic hot water heat recovery unit

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Axial and Mixed Flow Pumps for Large Volume Pumping

Wynn s Extended Care

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Fire Pump Plan Review March 2010

Rules for Classification and Construction Additional Rules and Guidelines

FLSmidth ball mill for cement grinding

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

NFPA31FuelOilPiping 1 Revised

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Horizontal Split Case Fire Pumpset Diesel Engine Driven

FAIRBANKS NIJHUIS FIRE PUMPS.

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

Gas Turbine Power COMPACT, EFFICIENT, RELIABLE

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

FIRE FIGHTING PACKAGES

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

RPV - RP - RA air handling units

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

Medical Air Systems: Scroll

Horizontal Jet Pumps 1/3-1-1/2 HP

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Model 1210C Battery Powered Pump Shown. Description

Automatic Back-Flushing Filter AutoFilt RF9.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

TOP 10 NOISE CONTROL TECHNIQUES

Specifications for Volkswagen Industrial Engine

Bringing it all together

912. The engine for construction equipment.

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

An Engineering Guide to Modern Fuel Systems

Hydraulic Troubleshooting PRESENTED BY

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

3516 Industrial Engine

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

SJT / SJM / SJP Large Vertical Pumps

ROTARY SCREW COMPRESSOR. RMD kw

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Pumps for Pipelines and Transportation

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

PUMP AND MOTOR DIVISION

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

SEPAR FILTER SEPAR 2000 SEPAR 2000

Factory owners must ensure the boiler is:

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

A/C refrigerant system, overview

ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS

Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

The Yachtmans Choice...

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Air Eliminators and Combination Air Eliminators Strainers

LNG Fuel Gas Infrastructure from terminal to onboard system The Motorship Gas-fuelled Ships 12 to 14-Sep-2012, Bergen

Rickmeier Solutions. Gear pumps for superior Lubrication

Section 11 - System Diagrams

Cooking at the Speed of light!

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.

Section 6 - System Diagrams

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

SECTION GENERAL PROVISIONS FOR HVAC WORK

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

Signature and ISX CM870 Fuel System

Copyright 2012 Mayekawa Mfg. Co.,Ltd. All Rights Reserved.

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Industrial Generator Set Accessories

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

1.3 Turbochargers are categorised in three groups depending on served power by cylinder groups with:

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

MEMBRANE VACUUM MINI PUMPS

Rotary screw compressors kw 5,5 7, , bar MODULO

TECHNICAL ADVISORY BULLETIN

Transcription:

Diesel-Hydraulic Driven Pumping Unit for Firefighting

Description of the System The Sulzer diesel-hydraulic driven pumping unit for offshore fi refi ghting systems consists of a vertical lift pump driven by a hydraulic motor that lifts sea water to the booster pump. The booster is fi tted inside a container mounted on the main deck which supplies sea water to the fi refi ghting ring mains on the ship or platform. The lift pump motor is driven by high pressure oil delivered by the hydraulic pumps installed in the container. The hydraulic pumps are driven by a diesel engine through a cardan shaft, the engine also drives the booster pump using a similar coupling arrangement. Hypochlorite injection Low speed system of the lift pump Container limit Hydraulic motor The centrifugal pumps fully comply with the ISO 13709 (API610) requirements. The system supplied by Sulzer Pumps runs completely autonomously. A complete hydraulic system to operate the lift pump is delivered within the container including: Hydraulic unit to run the lift pump at low speed Diesel engine Cooling system Fuel supply system for the diesel engine Electric and/or pneumatic start up system Batteries and battery chargers Heat exchanger reservoir Hydraulic pumps Diesel engine Surge tank Drain Overboard Fire rings Booster pump Heat exchanger Simplified P & ID Electrical and hydraulic ventilation system Gas, heat, fi re and smoke detection and controlling system CO 2 feed system and dampers. Complete operational control is performed by a PLC which is supplied with a customized control panel designed to meet the exact requirements of each customer. The marinized diesel engine is designed to operate under the most extreme operating conditions up to 150% of the normal condition within the motion limits of the vessel. Apart from complying with NFPA 20 requirements, a com- plete torsional analysis of the train is made, delivering very low vibration levels for the unit. In addition to the project specifi c features, the engine is fi tted on metallic anti-vibration mountings (AVM s) inside the container to further minimize vibration. The hydraulic system is made of a 350 bar hydraulic oil pressurization line containing pumps, control valves and safety valves to drive the lift pumps as well as a ventilation system. A low power pump motor unit is included to drive the lift pump at low speed. This prevents sea organisms from sticking inside and outside the lift pump, as well as to support the prompt starting up of the main diesel-hydraulic system. Cooling water for the hydraulic system and the diesel engine is obtained from the pressure line of the booster pump, ensuring the system is totally independent of external supply during any emergency. The diesel engine fuel tanks and supply system are designed in compliance with the NFPA 20 standard and the requirements of each customer. As a minimum at least 18 hours operation with the self contained fuel reserve is guaranteed. The starting system for the diesel engine may be electrical and/or pneumatic, being customized to the customers requirements. The latest variant is a low pressure system (30 bar) that offers higher availability with a smaller number of components reducing the risk of failure and ensuring easier maintenance. The ventilation system is designed according to the most rigorous requirements of both customers and Classifi cation Societies. It consists of ventilators driven by electric motors during the standby period and further ventilators driven by hydraulic motors during the diesel hydraulic system s operation. In addition to ventilators it also includes ducts and dampers whose operation is set by the system design logic criteria. The container is designed to comply with the most extreme conditions (for example, centenary waves), as well as the Classifi cation Societies design criteria. The internal distribution of equipment and accessories, doors and removable hatches on the roof and wall, as well as the dimensions of the container, make a practical area for access to and internal maintenance of all components. Rails and lifting gear fi tted to the roof of the container are included in the scope of supply in order to facilitate equipment handling within the container. Depending on the installation area of the container on board a ship or platform, the acoustic/thermal insulation of the module meets the requirements of SOLAS standards (A-0 or A-60). Lift pump

Container View of the Main Components Diesel engine exhaust system and silencer Container cooling system Container air inlet Heat exchanger Assured Performance All system components are fi eld proven and go through running tests in our testing facility following the most rigorous engineering standards and criteria. In addition, the whole fi re system including lift and booster pumps, hydraulic system, diesel engine and container components (ventilation, cooling and start up system, control panel, etc) is tested in our testing facility under full load and at 150% of the operating condition (string test). Container A-0 or A-60 Diesel engine air intake This test gives the system high reliability, granting its performance on the platform besides minimizing test, commissioning and starting up time on board. Surge tank Container air outlet Fire System Performance Range Head (m) 200 150 100 50 Diesel oil reservoir 0 500 1000 1500 2000 2500 3000 3500 3 Flow (m /h) Engine start up air accumulators Removeable fl oor grating Control panel Hydraulic power unit Diesel engine Booster pump

Lift Pump Submerged Centrifugal Pumps Booster Pump End Top or Axial Split Pumps The lift pumps are of the submerged type and hydraulically driven, lifting sea water through pipe columns. The hydraulic system consists of high and low pressure pipe concentric to the pipe column. Due to the high operating pressures combined with corrosive attack by sea water, the materials used for the construction of the pump are either duplex (ASTM A 890 Gr. 3A) or superduplex material (ASTM A 890 Gr. 6A), depending on operating conditions. The oil used to drive the hydraulic motor is also used for lubricating and cooling the bearings and shaft seals of the lift pump. The pressure of the hydraulic oil in the low pressure line is slightly higher than the pressure of the sea water inside the pipe column. External pipework is provided for the injection of hypochlorite in the suction line of the lift pump below the intake fi lter. The fi lter is generously dimensioned to prevent suction pressure losses and is fi tted within the suction bellmouth of the lift pump. (high pressure) (low pressure) Pipe stack Caisson The booster pumps may be of the OH2 or BB1 type to ISO 13709 (API 610). The selection takes into consideration customer specifi - cations as well as the operating conditions. The shaft seals and the fl ushing system are designed and manufactured according to API 682 standards, allowing dry operation during startup of the diesel-hydraulic system. The booster pumps supplied by Sulzer have NPSH req. according to ISO 13709 (NSS<11000) and perform to NFPA 20 criteria (150% of the normal operating condition), thus minimizing the pressure and the power of the lift pump. Booster pumps are manufactured in duplex or superduplex materials. OH2 Pump BB1 Pump Hydraulic motor Suction fi lter Hypochlorite injection

Check our worldwide offices at www.sulzerpumps.com E10018 en (8.2008), Copyright Sulzer Pumps This brochure is a general presentation. It does not provide any warranty or guarantee of any kind. Please, contact us for a description of the warranties and guarantees offered with our products. Directions for use and safety will be given separately. All information herein is subject to change without notice.