LS-S100 LS-N100. Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Similar documents
P10 - Standalone Access Controller and Reader

User Manual. Before installation and use, please read the user manual carefully.

Digital Keypad Use s Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

PROXIMITY CARD READERS C-10, C-20, C60, C70

AR-721U/721K/661U User s Guide

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

INSTALLATION MANUAL XM3 Reader

Model 201 Wiegand Touchpad Reader Installation Guide

GV- RK1352 Card Reader

PAC1 Door Access Controller

Adaptability to Enhanced Security

Adaptability to Enhanced Security

IEI 232e Standalone TM Keypad Installation/ Programming Manual

GV-AS Controller. Installation Guide

SECURITY SYSTEM ADP-CAN

AYC-FGx4 Family. Instruction Manual. Backlit, Waterproof Convertible Reader / Controllers. Models: AYC-F54 AYC-F64 AYC-G54 AYC-G64

Secure Keypads for access control

GV-AS/EV Controller. User s Manual

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Business/Home GSM Alarm System. Installation and User Manual

GSM Autodialer Professional GJD700 Speech & Text Autodialer

INSTALLATION GUIDE. FCC ID NOTICE

ACCESS CONTROL SYSTEM

VTO6xxx. IP door stations. User manual

1 x TS0861 Magnetic Swipe Card Reader. 1 x Installation Guide (this document).

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

VARIO PROX CARD READER INSTALLATION MANUAL

How To Program An Autodialer

1 Contactless Smartcard Reader Setup

EWR2 WIRELESS SIGNAL REPEATER

FIREDEX Conventional Fire Panels

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

2M IR Mini Dome Quick Installation Guide

CHAPTER 1. GETTING STARTED... 1

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

PUSH BUTTON START INSTALLATION MANUAL

Intelligent GSM Auto-dial Alarm System User s Manual

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Programming and Installation Instructions. Passed ISO international system ratification

PK5500 v1.1 Installation Instructions

Installation manual. Version

GSM Alarm System User Manual

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

POINTS POSITION INDICATOR PPI4

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

VIDEO DOOR PHONE SYSTEM

Automatic Telephone Dialer TD-101(W)

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

AUTODIALLER / QUICKDIALLER - SA132

How To Control A Car Alarm On A Car With A Remote Control System

Combi B Alarm box. Mounting instructions

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Digital input modules

Business/ Home GSM Alarm System

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

SYSTEM 45. C R H Electronics Design

9452/9453 Installation and User Guide

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

User s Information Guide R1A

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Voice Dialer Alarm System Installation Manual DA-712K

Color Mark Sensor with Red or Green LED E3S-VS

TS510 & TS500. Installation & User Guide. Compatible Equipment

HCR3.2/.. Chipcard reader HOTEL SOLUTION

SYSTEM 4C. C R H Electronics Design

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Auto Dialer. Manual E-921APQ E-921GPQ

PRO PLM Installation Instructions

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

COLOR VIDEO DOOR PHONE CDV-71BE/D


OCSM Series. High Resolution Digital Crane Scale. User Guide

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

Schlage Wireless Locks User Guide

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

AD-01 Slave Auto Dialer. Owner s Manual

EQUIPMENT SPECIFICATIONS

MOBILE CALL GSM Alarm System User s Manual

Original instructions Tina 3A/Aps Adaptor unit

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

NC-12 Modbus Application

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

FSLIMRF

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Transcription:

LS-S100 LS-N100 Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit

1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad Rubber plug 2 Φ6mm 30 mm, used for fixing Self tapping screws 2 Φ4mm 28 mm, used for fixing Star screws 1 Φ3mm 6mm, used for fixing Please ensure that all the above contents are correct. If any are missing please notify the supplier of the unit. 2. Quick Reference Programming Guide To enter the * Master code # 999999 is the default factory master code To exit from the * Note that to undertake the following programming the master user must be logged in To change the master code 0 New code # New code # The master code can be 6 to 8 digits To add a PIN user. 1 User ID number # PIN # The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting To add a card user 1 Read Card # Cards can be added continuously without exiting To delete a PIN or a card user. 2 User ID number # for a PIN user or 2 Read Card # for a card user Users can be deleted continuously without exiting 2

To unlock the door for a PIN user Enter the PIN then press # To unlock the door for a card user Present the card 3. Description The unit is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards,13.56mhz Mifare cards. The unit has many extra features including lock output current short circuit protection, Wiegand output, and a backlit keypad. These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 4. Features Waterproof, conforms to IP68 Strong Zinc Alloy Electroplated anti-vandal case Full programming from the keypad 2000 uses, supports Card, PIN, Card + PIN Can be used as a stand alone keypad Backlight keys Wiegand 26 input for connection to external reader Wiegand 26 output for connection to a controller Adjustable Door Output time, Alarm time, Door Open time Very low power consumption (30mA) Fast operating speed, <20ms with 2000 users Lock output current short circuit protection Easy to install and program Built in light dependent resistor (LDR) for anti tamper Built in buzzer Red, Yellow and Green LEDS display the working status 3

5. Specifications Operating Voltage DC 12V±10% User Capacity 2000 Card Reading Distance 3-6 cm Active Current <60mA Idle Current 25±5 ma Lock Output Load Max 3A Alarm Output Load Max 20A Operating Temperature -45 ~60 Operating Humidity 10%- 90% RH Waterproof Conforms to IP68 Adjustable Door Relay time 0-99 seconds Adjustable Alarm Time 0-3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock, Exit Button, External Alarm,External reader 6. Installation Remove the back cover from the keypad using the supplied special screw driver Drill 2 holes on the wall for the Self tapping screws and I hole for the cable Put the supplied rubber bungs to into the two holes Fix the back cover firmly on the wall with 2 Self tapping screws Thread the cable through the cable hole Attach the keypad to the back cover. 4

7. Wiring Colour Function Description Pink BELL_A Doorbell button one end Pale blue BELL_B Doorbell button to the other end Green D0 WG output D0 White D1 WG output D1 Grey ALARM Alarm negative(alarm positive connected 12 V+) Yellow OPEN Exit button one end(the other end connected GND) Brown D_IN Magnetic switch one end(the other end connected GND) Red 12V+ 12V + DC Regulated Power Input Black GND 12V - DC Regulated Power Input Blue NO Relay normally-on end(connect positive electric lock "-") Purple COM Relay Public end, connect GND Orange NC Relay Closed end(connect negative electric lock "-") Magnetic lock and Fail-Safe lock diagram: 5

Electric Strike and Fail-Secure wiring diagram: 8. To Reset to Factory Default a. Disconnect power from the unit b. Press and hold # key whilst powering the unit back up c. On hearing two Di release # key, system is now back factory settings Please note only installer data is restored, user data will not be affected 9. Anti Tamper Alarm The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. 10.Sound and Light indication Operation Status Red Light Green Light Yellow Light Buzzer Power on - Bright - Di Stand by Bright - - - Press keypad - - - Di Operation successful - Bright - Di 6

Operation failed - - - DiDiDi Enter into Bright - - In the - - Bright Di Exit from the programming Bright - - Di mode Open the door - Bright - Di Alarm Bright - - Alarm 11. Detailed Programming Guide 11.1 User Settings * Master code # 999999 is the default factory master code To enter the To exit from the * Note that to undertake the following programming the master user must be logged in To change the master code 0 New code # New code # The master code can be 6 to 8 digits long Setting the working mode: Set valid card only users Set valid card and PIN users Set valid card or PIN users 3 0 # Entry is by card only 3 1 # Entry is by card and PIN together 3 2 # Entry is by either card or PIN (default) To add a user in either card or PIN mode, i.e. in the 3 2 # mode. (Default setting) To add a Pin user 1 User ID number # PIN # The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting as follows: 1 User ID no 1 # PIN # User ID no 2 # PIN # To delete a PIN user 2 User ID number # Users can be deleted continuously without exiting To change the PIN of a PIN user (This step must be done out of * ID number # Old PIN # New PIN # New PIN # 7

) To add a card user (Method 1) This is the fastest way to enter cards, user ID number auto generation. To add a card user (Method 2) This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card. To add a card user (Method 3) Card number is the last 8 digits printed on the back of the card,user ID number auto generation To add a card user (Method 4) In this method a User ID is allocated to a card number. Only one user ID can be allocated to the card number 1 Read card # Cards can be added continuously without exiting 1 ID number # Read card # User can be added continuously without exiting 1 Card number # User can be added continuously without exiting 1 ID number. # Card number. # User can be added continuously without exiting To delete a card user by card. Note users can be deleted continuously without exiting 2 Read Card # To delete a card user by user ID. This option can be used when a user has lost their card 2 User ID # To delete a card user by card number. This option can be used when the user want to make the change but the card has lost 2 Card number # Note users can be deleted continuously without exiting To add a card and PIN user in card and PIN mode (3 1 # ) To Add a card and Pin user (The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved.) Add the card as for a card user Press * to exit from the Then allocate the card a PIN as follows: * Read card 1234 # PIN # PIN # 8

To change a PIN in card and PIN mode (Method 1) Note that this is done outside so the user can undertake this themselves To change a PIN in card and PIN mode (Method 2) Note that this is done outside so the user can undertake this themselves To delete a Card and PIN user just delete the card * Read Card Old PIN # New PIN # New PIN # * ID number # Old PIN # New PIN # New PIN # 2 User ID # To add a card user in card mode (3 0 # ) To Add and Delete a card user The operating is the same as adding and deleting a card user in 3 2 # To delete All users To delete ALL users. Note that this is a dangerous option so use with care 2 0000 # To unlock the door For a PIN user Enter the PIN then press # For a card User Read card For a card and PIN user Read card then enter PIN # 9

11.2 Door Settings Relay Output Delay Time To set door relay strike time * Master code # 4 0~99 # * 0-99 is to set the door relay time 0-99 seconds Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is forced open, or if the door is opened after 20 seconds,the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0-3 minutes with the default being 1 minute. To disable door open detection. (Factory default) 6 0 # To enable door open detection 6 1 # Alarm output time To set the alarm output time (0-3 minutes) Factory default is 1 minute 5 0~3 # Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm and the inside buzzer will operate for 10 minutes, depending on the option selected below. Normal status: No keypad lockout or alarm (factory default) 7 0 # (Factory default setting) Keypad Lockout 7 1 # Alarm and inside buzzer operate 7 2 # To remove the alarm To reset the Door Forced Open warning Read valid card or Master Code # To reset the Door Open Too Long warning Close the door or Read valid card or Master Code # 10

12.The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input. 11