Electrical connection



Similar documents
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

DALI RC BASIC SO. Control unit Operating instructions

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Measuring Sensors PRODUCT DESCRIPTION

CONFIGURABLE SAFETY RELAYS

Cable Plug acc. to DIN EN , Form A

Cross-beam scanning system to detect slim objects. 100 mm in

intelligent solutions

Barcode Reader Series BCL 31, BCL 32, BCL 34

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Electronic Pressure Switch EDS 300

W150: Miniature photoelectric switch series with completely integrated electronics

technical data (according to IEC )

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

DB 12 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION GB 03-08/

MINI MCR-SL-R-UI(-SP)

Color Mark Sensor with Red or Green LED E3S-VS

Digital display DA 48

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

instabus KNX / EIB System System E F G H

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

WD-AMX Water Detection Controllers

Electronic Pressure Switch EDS 3000

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

LUT Luminescence scanners: Seeing what no-one else can

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

RS - SPM. Serial parallel translator module

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Multifunction devices

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

How To Use A Power Supply On A Powerline 2.2 (Ai)

W 160: Miniature series for optimum solutions

Universal Voltage Terminal Photoelectric E3JM

Smart DeviceNet Remote I/O Terminals

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Magnetic proximity switches

Inductive sensor NI10-M18-Y1X-H1141

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Capacitive Prox E2K-X

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Operating Instructions. Keypad

CONFIGURABLE SAFETY RELAYS

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

photoelectric highlights

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

W 36: Mastering complex tasks reliably

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

COOL Shelf Quick Connect

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Inwall 4 Input / 4 Output Module

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Technical Data. Dimensions

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PTC-Resistor Temperature-Sensors MINIKA to DIN and DIN

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Smart Sensing Solutions Since 1954

MSL1000 Monitored Serial Link Interface Manual V1.01

Power Supplies 3. SDN-P DIN Rail Series

Series AMLDL-Z Up to 1000mA LED Driver

Safety technique. Emergency stop module BO 5988 safemaster

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Transcription:

(I)GSU 14B Ultrasonic Label Fork Dimensioned drawing Part No. 501 09234 4mm 12-30 V DC 4 m/s Ultrasonic forked sensor for universal application Large mouth width, hence also suitable for booklets or fan-fold flyers Basic version GSU 14B comparable with the previous model GSU 14 IGSU 14B only: NEW easyteach function: press button - dispense labels - done! NEW ALC function (Auto Level Control): highest performance reserve through autonomous online optimisation of the switching threshold NEW Warning output for indicating teach or function errors NEW Easy adjustment via lockable teach button or teach input A B C D E Sensor marker (centre of label tape) Teach-in button Indicator diodes (ON, OUT, WARN) View with extended carriage mounted Sensor We reserve the right to make changes GS_A05gb.fm IP 65 Accessories: U L US C LISTED UL approval applied for (available separately) Carriage short (Part No. 501 09580) As replacement for the series part. Extended carriage (Part No. 501 09579) For better guiding of oversized labels. The rail can be shortened at any point. M12 connectors (KD ) Cable with M12 connector (K-D...) Electrical connection GSU 14B/66.3-S12 IGSU 14B/6.3-S12 GSU 14B/66D.3-S12 IGSU 14B/6D.3-S12 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.de www.leuze.com GSU 14B - 02 IGSU 14B - 02 1

(I)GSU 14B Specifications Physical data Mouth width 4mm Mouth depth 68mm Label length 5mm Label width 10mm Label gap 2mm Conveyor speed 240m/min (4m/s) Conveyor speed with teach-in 50m/min (0,83m/s) Typ. response time 200 µs Repeatability 1) ±0.2mm Delay before start-up 300ms acc. to IEC 60947-5-2 Electrical data Operating voltage U B 12VDC (-5%) 30VDC (incl. residual ripple) Residual ripple 15% of U B Open-circuit current ma Switching output 2) /66 2 push-pull switching outputs pin 4: PNP light switching, NPN dark switching pin 2: PNP dark switching, NPN light switching /66D 2 push-pull switching outputs pin 4: PNP dark switching, NPN light switching pin 2: PNP light switching, NPN dark switching /6 1 push-pull switching output pin 4: PNP light switching, NPN dark switching /6D 1 push-pull switching output pin 4: PNP dark switching, NPN light switching Warning output 2) 1 push-pull switching output pin 2: active low (normal operation high, event case low) Function switching output IGSU light/dark switching adjustable Signal voltage high/low (U B -2V)/ 2V Output current 100mA Capacitive load 0,5µF Indicators Green LED ready Green LED, flashing teach-in activated Yellow LED switching point in the label gap Red LED teach error / function error Mechanical data Housing aluminium, anodised Colour red/black Weight 160g Connection type M12 connector, 5-pin Environmental data Ambient temp. (operation/storage) 0 C +60 C/-40 C +70 C Protective circuit 3) 1, 2 VDE safety class III Protection class IP 65 Standards applied IEC 60947-5-2 Options Teach-in input Active/not active 8V/ 2V Input resistance 15kΩ 1) Depending on conveyor speed, label length and spacing between labels 2) The push-pull switching outputs must not be connected in parallel 3) 1=polarity reversal protection, 2=short-circuit protection for all outputs Order guide Designation Part No. Function comparable to predecessor model GSU 14, GSU 14B/66.3-S12 501 09498 switching output preset to light switching (signal in the label gap) Marking on the sensor A B Label centre position Label run Remarks Approved purpose: The ultrasonic label forks are ultrasonic sensors for contactless detection of the gap between two consecutive labels on a carrier tape. To achieve high repeatability, the label tape must be slightly under tension. Align the label tape according to the sensor s marker "Label centre position" (see also marking on sensor). The label material used determines the achievable precision and the reliability of gap detection! Light switching: signal in the label gap. Dark switching: signal on the label. Function comparable to predecessor model GSU 14, GSU 14B/66D.3-S12 501 09499 switching output preset to dark switching (signal on the label) With warning output, easyteach and ALC function, switching output preset to light switching (signal in the label gap) With warning output, easyteach and ALC function, switching output preset to dark switching (signal on the label) IGSU 14B/6.3-S12 501 09276 IGSU 14B/6D.3-S12 501 09277 GSU 14B - 02 0807 IGSU 14B - 02 2

(I)GSU 14B Ultrasonic Label Fork Comparison of device versions Basic functions GSU 14B (Basic) IGSU 14B (Advanced) Directly comparable to GSU 14 - Universal application (paper, transparent foil, metallized foil) Suitable for booklets and fan-fold flyers Maximum conveyor speed up to 240m/min (4m/s) Typ. response time 200µs 1 adjustable switching output (light or dark switching function) - 2 switching outputs - Special functions Manual teach-in - easyteach - Online optimisation of the switching threshold by ALC (auto level control) - Warning display on the device Warning output for indicating teach or function errors - Overview of operating structure for GSU 14B Standard function Normal operation after switch-on LED ON - green LED OUT - yellow LED WARN - red = ready = switching output = warning output Manual teach (as in GSU 14) Also available as dynamic teach-in 2 s LED ON - green and LED OUT - yellow flashing simultaneously 3 x per sec. LED WARN - red is off, if teach is error-free = function lockable through constant application of U B on the teach input

GSU 14B Standard function During operation the sensor is always in this function. The sensor detects label gaps with high precision and speed. This is indicated by the yellow LED and the switching output. Indicators: LED ON - green Constantly ON when operating voltage is applied. LED OUT - yellow label gaps. The display is independent of the output setting. Indicates the switching signal. LED is ON if the sensor detects LED WARN - red Is OFF if operation is error-free. If the "ALC function error" message appears, the red LED lights. Operation The teach button must be pressed for at least 2 seconds to operate the device. The button can be electrically disabled to prevent accidental operation. Sensor setting (Teach-In) via teach button for GSU 14B Manual teach while label tape is passing through (dynamic) Preparation: Insert label tape into the sensor. Press the teach button until green and yellow LEDs flash simultaneously. Release teach button. Advance the label tape through the sensor. Press the button briefly once more to terminate the teach process, the sensor goes into standard mode. 3 7 label gaps should be passed through the sensor in order to achieve stable switching points. If the teach process is faulty (e.g. unfavourable material combination, uneven transport, jittering during transport), the red LED lights. Repeat the teach process. If the fault cannot be rectified, the label material cannot be detected with the GSU 14B. Sensor setting (Teach-In) via teach input for GSU 14B ³2s The green and the yellow LEDs flash simultaneously approx. 3x per sec. Manual teach while label tape is passing through (dynamic) Preparation: Insert the label tape in the correct position in the sensor (align the middle of the tape to the sensor marking). U Teach on U Teach off After switching on the supply voltage and after the delay before start-up has concluded ( 300ms), the teach button on the device can be operated. High level on the teach-in input triggers the teach process. Advance 3 7 labels through the sensor. Sensor remains in teach as long as the high signal is applied. The edge transition (1 -> 0) terminates the teach process. The sensor is in normal operation again. At the same time the teach button is disabled with the first The button remains disabled until the sensor is rising edge (0 -> 1). switched off. Attention: The button remains disabled as long as voltage is supplied to the sensor (until the sensor is switched off). t A rising edge triggers a new teach process. The button remains disabled until the sensor is switched off. The red LED lights if a teach error occurs (e.g. the label cannot be reliably detected due to insufficient signals). Regardless of the state, the green LED is on when the teach process is terminated, the yellow LED indicates the current switching state.

IGSU 14B Ultrasonic Label Fork Overview of operating structure for IGSU 14B Standard function Normal operation after switch-on LED ON - green LED OUT - yellow LED WARN - red = ready = switching output = warning output 2 s easyteach (Level 1) Teach-in for best function LED ON - green and LED OUT - yellow flashing simultaneously 1 x per sec. LED WARN - red is off, if teach is error-free automatic 7 s ALC function (Level 2) ALC function can be switched on or off (only possible via teach button!) LED ON - green and LED WARN - red flashing alternating 3x per sec. If button released, green LED ON continues to flash LED WARN - red: on = ALC on off = ALC off Pressing the button briefly once more terminates the setting with the currently indicated ALC state Setting switching behaviour (Level 3) Setting of the light/dark switching output 12 s LED ON - green and LED OUT - yellow flashing alternately 3x per sec. If button released, green LED ON continues to flash LED OUT - yellow: on = light switching off = dark switching Pressing the button briefly once more terminates the setting with the currently indicated switching behaviour = function lockable through constant application of U B on the teach input

IGSU 14B Sensor setting (Teach-In) via Teach button for IGSU 14B easy Teach while the label tape is passing through Preparation: Insert label tape into the sensor. Press the teach button until green and yellow LEDs flash simultaneously. Release teach button. Advance the label tape through the sensor at a max. speed of 50 m/min. The sensor indicates the tape transport by faster simultaneous flashing of the green and yellow LED. Ready. If sufficient teach values are determined, the sensor automatically terminates the teach process and goes into standard mode. The transport of the label tape can be stopped immediately. The number of labels to be transported is always based on the material combination: from experience the value lies at between 2 and 10 labels. If the teach process is faulty (e.g. unfavourable material combination, uneven transport, jittering during transport), the red LED lights. Repeat the teach process. If the fault cannot be rectified, the label material cannot be detected with the IGSU 14B. 2 7s The green and the yellow LEDs flash simultaneously approx. 1x per sec. Adjusting the ALC function for IGSU 14B Press the teach button until green and red LEDs flash alternately. Release the teach button - the green LED continues to flash, the red LED alternates slowly between ON and OFF. Red LED ON = ALC function on Red LED OFF = ALC function off. Pressing the button briefly once more terminates the setting with the currently indicated ALC state. Ready. Attention: This function can only be executed with the teach button! 7 12s About ALC function (Auto Level Control): In each teach process the current signal values in the sensor are digitally determined, resulting in the optimum switching threshold being calculated for maximum performance reserve. All values are saved and are non-volatile, retaining their validity as long as the dynamic parameters of the system remain unchanged and the material is not changed. Signal changes can result each time the roll is changed, even with labels that are apparently the same. This is caused, for example, by material variations (material thickness, homogeneity, etc.) which affect the acoustic impedance of the system. Even changes of the dynamic parameters (e.g. tape tension, middle position, jitter, etc.) can have a negative affect on the performance reserve of the sensor. When the ALC function is switched on, the sensor now automatically corrects the switching threshold in such a way that the maximum performance reserve is always available during operation - the sensor works absolutely reliably and free of errors. When changing to another type of label, however, a new adjustment must generally be carried out by carrying out a new teach-in process. The green and the red LEDs flash alternately approx. 3x per sec.

IGSU 14B Ultrasonic Label Fork Adjusting the switching behaviour of the switching output (light/dark switching) for IGSU 14B Press the teach button until green and yellow LEDs flash alternately. Release the teach button - the green LED continues to flash, the yellow LED alternates slowly between ON and OFF. yellow LED ON = output switches on light yellow LED OFF = output switches on dark. Pressing the button briefly once more terminates the setting with the currently indicated switching behaviour. Ready. >12s The green and the yellow LEDs flash alternately approx. 3x per sec. Sensor setting (Teach-In) via teach input for IGSU 14B The following description applies to PNP switching logic! U Teach not connected Internal pull-down resistor pulls the input down to zero The device setting is stored in a fail-safe way. A reconfiguration following voltage interruption or switch-off is thus not required. easyteach while label tape is passing through Teach button can be operated; all functions adjustable U Teach low 2V Low level Teach button can be operated; all functions adjustable U Teach high (U B -2V) High level Teach button disabled; button has no function U Teach >2V <(U B -2V) Not permitted Level not defined; current state is retained Preparation: Insert the label tape in the correct position in the sensor (align the middle of the tape to the sensor marking). Button disabled U Teach high Button enabled U Teach low After switching on the supply voltage and after the delay before start-up has concluded ( 300ms), the teach button on the device can be operated. 2x 4 100ms Only if the teach button was disabled before the teach. The teach button is disabled after the 1st edge transition. easyteach: t Teach = 4 900ms t 4 100ms Teach process starts: The green and yellow LEDs flash simultaneously approx. 1x per second. Advance labels at a tape running speed of max. 50m/min through the sensor until the teach process is automatically terminated by the sensor, i.e. the LEDs no longer flash. The number of labels which must be transported depends on the carrier and label material. During the process the button on the device is disabled, it can be operated again after this. The red LED lights if a teach error occurs (e.g. the label cannot be reliably detected due to insufficient signals). Regardless of the state, the green LED is on when the teach process is terminated, the yellow LED indicates the current switching state.

(I)GSU 14B Adjusting the switching behaviour of the switching output light/dark switching Button disabled 2100 3000ms 4 900ms 1100 2000ms Button enabled After switching on the supply voltage and after the delay before start-up has concluded ( 300ms), the teach button on the device can be operated. 2x 4 100ms The teach button is disabled after the 1st edge transition. The teach button is disabled after the 1st edge transition. Teach switching output: t Teach = 2100 3000ms Switching output light switching (4 900ms) Switching output dark switching (1100 2000ms) t The teach button is enabled again. Locking the teach button via the teach input GSU 14B: The teach button is disabled with the first rising edge (0 -> 1) on the teach input. Attention: The button remains disabled until the sensor is switched free of voltage (disabled). IGSU 14B: A static high signal ( 4ms) on the teach input locks the teach button on the device if required so that no manual operation is possible (e.g. protection against erroneous operation or manipulation). If the teach input is not connected or if there is a static low signal, the button is enabled and can be operated freely.