XT/TF. High performance PIR timber frame insulation board. Insulation for timber framed walls. OCTOBER Affordable innovation.

Similar documents
Innovation - High performance roof, wall and floor insulation board. delivering better performance

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Steel-framed Walls. Insulation

Multi-layer Insulation Blanket for Roofs

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Timber Frame Walls Rethinking Construction

The Kingspan Insulation Price List 1 st January 2013

Low Energy Low Carbon Buildings

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Rockwool Flexi Insulation Application Guide

Rockwool Cladding Roll

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Module 3.7. Thermal bridging

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Building Regulations for the Conservation of Fuel and Power

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

Low Energy Low Carbon Buildings

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

The Pocket Guide To Insulation August 2013

Rev Code of Practice. SIP Technology.

Energy Company Obligation (ECO): Technical Monitoring Questions

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Continuous Insulation Using Polyiso Wall Sheathing

ProRox Slabs (formerly known as RW slabs)

BER Assessors Dwellings Technical Bulletin

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

2014 British Columbia Building Code Changes

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Roof Insulation Building. Energy. Environment friendly e-library

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Architectural composite panels

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Providing protection in construction

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

Internal wall insulation in existing housing

SIP (STRUCTURAL INSULATED PANEL)

Composite Panel Firewall Systems

Renovating Your Basement

floor TF70 Insulation INSULATION FOR SOLID CONCRETE AND SUSPENDED GROUND FLOORS

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

European Organisation for Technical Approvals

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

OLDROYD. Interior Walls. Interior Walls. below and above ground. below and above ground

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

COMMERCIAL BUILDING APPLICATIONS

Confort 160. Sliding Systems. Sapa Building System

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

INSULATED PITCHED ROOFING

School in Schwanenstadt, Austria

PROFILED METAL ROOFING DESIGN GUIDE

EcoTouch Insulation with PureFiber Technology

Mineral fibreglass insulation

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Improving thermal insulation of concrete sandwich panel buildings

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

I n s u l a t i o n. Low Energy Low Carbon Buildings

GYPSUM AREA SEPARATION FIREWALLS GA

Fire safety in timber buildings

AND MEMBRANES ROOFING UNDERLAYS.

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Physically Crosslinked Foam Insulation

ROOFS, SNOW AND ICE DAMS

Rooflighting and Glazing

DEFAULT HEAT LOSS COEFFICIENTS

The WANZ Guide to Window Installation

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Heating Load Calculation

plumbing products guide

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

FireSmart IRS Insulating Roof Screed

Transcription:

OCTOBER 2010 Affordable innovation. High performance PIR timber frame insulation board Insulation for timber framed walls XT/TF COST EFFECTIVE THERMAL SOLUTIONS www.xtratherm.com

Timber Frame Insulation Xtratherm s Timber Frame Insulation Systems, brings Timber Framed wall insulation performance to new levels, surpassing regulation default values of 2006 and aiming for those standards indicated for 2016 when Zero Carbon or passive homes will be required under the Building Regulations. U-values The insulation performance of a building envelope, wall, floor or roof is measured as a U-value, and is expressed as W/m 2 K. Previous building regulation standards have quoted target U-values for walls of between 0.30 and 0.35 W/m 2 K, but recent changes have dispensed with issuing these target values and instead concentrate on Whole House Performance. Building Timber Frame construction is a fast, systematic method that can results in buildings that perform well in Environmental terms and provide excellent Energy Performance ratings, if insulated to the highest standards. Xtratherm Thin-R Polyisocyanurate is a thermoset closed cell rigid foam insulation. During a continuous manufacturing process, liquid raw materials expanded by blowing agents are applied between a variety of engineered facings. The facings provide strength, rigidity and enhanced thermal performance. It is now a requirement to measure the energy efficiency of the building as a whole, and thus the amount of CO2 produced, it is only by keeping the amount of CO2 within a specific target that compliance with the building regulations is achieved. The following steps need to be addressed to make a building more energy efficient: A well insulated Building Fabric with Improved Robust Detailing Air Tight Build Effective Heating System & Controls Efficient Secondary Heating Controlled Ventilation Energy Effi cient Lighting Low & Zero Carbon Technologies The high R-values achieved by Xtratherm Thin-R allows for highly efficient low energy design to new Building Regulation standards without the necessity to increase wall, floor or roof thickness. Xtratherm Thin-R is CFC/HCFC free (Zero Ozone Depletion Potential). The single most important factor is the provision of an effective building fabric with excellent U-values and robust detailing. This effectively reduces the energy demand required to heat the buildings, this reduced energy target can then be produced with Low and Zero Carbon systems. 02

Timber Framing & Thermal Bridging Placing insulation between the timber framing studding has proven effective until recent changes to building regulations have asked for U-values better than 0.27 W/m 2 K. Improving the wall performance past this figure has proven difficult cult because of the amount of timber that bridges the insulation. The timber studs, wall and foot plates, and noggins that cut through the insulation when it is placed between the studs must be taken at a default of 15% of the total wall area, but can be higher in certain circumstances. LAYERS Thickness (mm) Conductivity (W/m 2 K) Resistance (m 2 K/W) Internal surface resistance 0.130 Plasterboard 13 0.180 0.069 Vapour control layer 1 000 0.000 Glass fibre/wool quilt between studs 140 0.044 2.527 Plywood sheathing 12 0.130 0.092 Breather membrane 1 000 0.000 Cavity unventilated 50 0.180 Concrete block (heavyweight) 100 1.150 0.087 External rendering (cement/sand) 19 0.570 0.033 External surface resistance 0.040 U-value [W/m 2 K] 0.31 Upper/lower resistance 3.265 / 3.159 W/m 2 K Correction for air gaps / mechanical fasteners 0.000 W/m 2 K Glass fibre/wool quilt between studs Is there repeating thermal bridging? Yes Bridging conductivity [W/m K] 0.12 Bridging material studs Bridging thickness [mm] 140 Fractional area of bridging [-] 0.15%* Correction for air gaps Air gaps present but no air circulation Correction for mechanical fasteners Not applicable *Part L Irl: All thermal bridging over 16% must be specifically accounted for in calculation. Timber Framing & Lower U-Values Because of the restriction that stud depth presents, the only pragmatic solution to pushing timber frame wall performance toward 0.20 W/m 2 K is to actually insulate the thermal bridges (Timber studs) with either internal insulated lining or externally with an insulated sheathing board in the traditional cavity. The BRE with the support of Xtratherm have published a paper on achieving significantly improved U-values in Timber Framed constructions, based on the constructions outlined in this publication, reaching a very efficient 0.14 W/m 2 K. For your copy, please contact Xtratherm Technical support In the above example an additional 30mm of Xtratherm applied as an insulated sheathing improves the U-value to 0.20 W/m 2 K exactly. To achieve this U-value in the same example using fibre, the studs would have to be increase to 250mm. www.xtratherm.com 03

System 1 Fibre between studs with Xtratherm Sheathing Using a fibrous glass or stonewool type of material between studs is the most common method of insulating Timber Framed constructions. Although not as efficient in insulation values, the flexibility of the materials allows the insulation to be squeezed between studs with irregular spacings. Placing a lining of Xtratherm XT/SB Sheathing Boards into the traditional cavity of the construction, and effectively insulating the thermal bridging caused by the timber studding drastically improves the insulation value of the walls. Installation: Glass fibre insulation should be cut to fit snugly between the timber studding. The full depth of the stud should be filled with insulation. Place a sealed vapour control layer with lapped and sealed joints over the stud face. Install cavity barriers into the cavity as normal practice. Fix the Xtratherm XT/SB sheathing board outside the breather membrane on the external surface and temporarily fix with large headed clout nails. Ensure boards are closely butted and stagger jointed. DO NOT TAPE THE OUTER FACE OF THE XTRATHERM SHEATHING BOARDS (Boards are marked with same reference) Apply the internal finish as normal. Fix wall ties as recommended by timber frame supplier. Relevant accredited details should be followed to ensure calculated performance. The timber frame insulation shall be Xtratherm Xtratherm Thin-R XT/SB Zero ODP.. mm thick manufactured to EN ISO 9001: 2000 by Xtratherm comprising a CFC/HCFC free rigid Polyisocyanurate (PIR) core between low emissivity foil facings. The timber frame insulation shall be installed in accordance with instructions issued by Xtratherm. Refer to NBS clause F30 151, K10 14, K10 205, P10 210. DIMENSIONS XTRATHERM XT/SB Length (mm) 1200 Width (mm) 600 Thickness (mm) 30, 40, 50 Other sizes and thicknesses available depending on quantity and lead time. 04 FOR TECHNICAL SUPPORT CALL 0371 222 1033

System 2 Fibre between studs with Xtratherm Lining and Insulated service void As with system 1, using a fibrous glass or stonewool type of material between studs allows the insulation to be squeezed between studs with irregular spacings. An alternative to applying a Sheathing Insulation into the cavity to improve the thermal bridging factor of the timber, is to place a lining of Xtratherm XT/TF over the studding to the inside face of the construction, thus improving the insulation value of the wall. An insulated service duct can be created by placing counterbattens between the Xtratherm and plasterboard finish allowing services to be placed without compromising the integrity of the vapour control layer and enhancing the air tightness. Installation: Glass fibre insulation should be cut to fit snugly between the timber studding. The full depth of the stud should be filled with insulation. Place a sealed vapour control layer with lapped and sealed joints over the stud face. Temporarily fix the Xtratherm XT/TF board to the inner face of the timber studding ensuring that the insulation makes contact or over laps with ceiling and floor insulation. Mark the line of the timber studs on the Xtratherm XT/TF boards to allow fixing of counterbatten. Boards should be butted tightly against each other to prevent gaps, and tape joints with aluminium tape. Taping the joints with aluminium tape provides and effective vapour control layer and excellent air permeability barrier. Seal the insulation at all service penetrations. Fix counterbatten through the insulation to the timber studding and ensure that battens along the top and bottom of each sheet and around all openings (doors, windows etc). Fix plasterboard to counterbattens and secure with approved nails or screws to the appropriate length, finish as normal. Relevant accredited details should be followed to ensure calculated performance. The timber frame insulation shall be Xtratherm Thin-R XT/TF Zero ODP..mm thick manufactured to EN ISO 9001: 2000 by Xtratherm comprising a CFC/HCFC free rigid Polyisocyanurate (PIR) core between low emissivity foil facings. The timber frame insulation shall be installed in accordance with instructions issued by Xtratherm. Refer to NBS clause F30 151, K10 14, K10 205, P10 210. DIMENSIONS XTRATHERM XT/TF Length (mm) 2400 Width (mm) 1200 Thickness (mm) 30, 40, 50 Other sizes and thicknesses available depending on quantity and lead time. See www.xtratherm.com for installation animations 05

System 3 Fibre between studs with Xtratherm Lining As with systems 1 & 2, using a fibrous glass or stonewool type of material between studs allows the insulation to be squeezed between studs with irregular spacings. An alternative insulation lining system to improve the thermal bridging factor of the timber, is to place a lining of Xtratherm over the studding to the inside face of the construction. Installation: Fibrous insulation should be cut to fit snugly between the timber studding. The full depth of the stud should be filled with insulation. Place a sealed vapour control layer with lapped and sealed joints over the stud face. Temporarily fix the Xtratherm XT/TF board to the inner face of the timber studding ensuring that the insulation makes contact or over laps with ceiling and floor insulation. Mark the line of the timber studs on the Xtratherm XT/TF boards to allow fixing of plasterboard. Boards should be butted tightly against each other to prevent gaps. Taping the joints with aluminium tape provides an effective vapour control layer and excellent air permeability barrier. Seal the insulation at all service penetrations. Fix plasterboard over the Xtratherm XT/TF board and secure with approved nails or screws to the appropriate length, and finish as normal. Alternatively, Xtratherm XT/TL Thermal laminate may be placed over the timber studding onto which a vapour control layer of 1000g polythene with fully lapped and sealed and joints has been installed, providing insulation and plasterboard in one fixing operation. Relevant accredited details should be followed to ensure calculated performance. The timber frame insulation shall be full fill fibre between studs with Xtratherm Thin-R XT/TF Liner Zero ODP..mm thick manufactured to EN ISO 9001: 2000 by Xtratherm comprising a CFC/HCFC free rigid Polyisocyanurate (PIR) core between low emissivity foil facings. The timber frame insulation shall be installed in accordance with instructions issued by Xtratherm. Refer to NBS clause F30 151, K10 14, K10 205, P10 210. DIMENSIONS XTRATHERM XT/TF Length (mm) 2400 Width (mm) 1200 Thickness (mm) 30, 40, 50 Other sizes and thicknesses available depending on quantity and lead time. 06 FOR TECHNICAL SUPPORT CALL 0371 222 1033

System 4 Xtratherm between studs only The traditional method of insulating Timber Framed walls is to provide insulation between the studs only. Typically 80mm of Xtratherm XT/TF will achieve a U-value of 0.27W/m 2 K. Installation: Xtratherm XT/TF boards should be cut to fit tightly between the timber studding. The Xtratherm should be positioned against the sheathing board. The boards should be held in place by nails or a timber batten to the warm side of the insulation. This void may be utilised as an insulated service duct. Place a sealed vapour control layer with lapped and sealed joints over the stud face before applying the internal finish. Relevant accredited details should be followed to ensure calculated performance. DIMENSIONS XTRATHERM XT/TF Length (mm) 2400 Width (mm) 1200 Thickness (mm) 75, 80, 90, 100, 125 Other sizes and thicknesses available depending on quantity and lead time. The timber frame insulation shall be Xtratherm Thin-R XT/TF Zero ODP between timber studs..mm thick manufactured to EN ISO 9001: 2000 by Xtratherm comprising a CFC/HCFC free rigid Polyisocyanurate (PIR) core between low emissivity foil facings. The timber frame insulation shall be installed in accordance with instructions issued by Xtratherm. Refer to NBS clause F30 151, K10 14, K10 205, P10 210. Product Description Xtratherm XT/TF Timber Frame boards consists of a rigid Polyisocyanurate (Polyiso) core and low emissivity gas tight aluminium foil facings on both sides. Xtratherm Thin-R XT/TL Thermal Liner is a composite insulated panel of Xtratherm Polyiso (PIR) core and low emissivity gas tight aluminium foil facing, bonded to plasterboard. Xtratherm XT/SB consists of a rigid Polyisocyanurate (Polyiso) core and low emissivity gas tight aluminium foil facings on both sides. Standards Xtratherm products are manufactured under quality systems approved under EN ISO 9001: 2000. Durability Xtratherm products are stable, rot proof and durable. They will remain an effective insulant for the life of the building. Packaging Xtratherm XT/TF boards are wrapped in polythene packs and each pack is labelled with details of grade/type, size and number of pieces per pack. Handling & Storage XT/TF should be stored off the ground, on a clean, flat surface and must be stored under cover. The polythene wrapping of Xtratherm packs are not considered adequate protection for outside exposure. Cutting Xtratherm XT/TF can be readily cut using a sharp knife or a figure ne toothed saw. Health & Safety All Xtratherm products are safe to use and chemically inert. Full Health & Safety documentation is available from the Xtratherm Technical Support Department. See www.xtratherm.com for installation animations 07

The Xtratherm range of high performance insulation boards provides the complete solution for newbuild and refurbishment. XT/TF Timber Frame Boards PROPERTY UNIT Density (Foam Core) 32 (Kg/m 3 ) Compressive Strength Water Vapour resistivity Thermal Conductivity Service Temperature >140 (kpa) >100 (MNs/gm) 0.022 (W/mK) Surface Spread of flame Class 1-20 to +100 (ºC) U-value Performance The following tables give indicative U-values performance using Xtratherm Systems in timber framed constructions. Values have been calculated on the depth of studding being 89mm and 140mm and the thermal bridging fraction taken at 15%. System 1 XT Sheathing with full fill fibre between studs (0.044) XT/SB Thickness U - VALUE 89mm Stud 140mm Stud 30mm 0.24 0.19 40mm 0.22 0.18 50mm 0.20 0.17 System 2 XT Lining with Service Void, full fill fibre between studs (0.044) XT/TF Thickness U - VALUE 89mm Stud 140mm Stud 25mm 0.25 0.20 30mm 0.24 0.19 40mm 0.21 0.18 50mm 0.19 0.16 System 3 XT Lining with full fill fibre between studs (0.044) XT/TF Thickness U - VALUE 89mm Stud 140mm Stud 25mm 0.29 0.23 30mm 0.27 0.22 40mm 0.24 0.20 50mm 0.22 0.18 System 4 XT only between studs XT/TF Thickness www.xtratherm.com 89mm Stud U - VALUE 140mm Stud 80mm 0.30 0.27 90mm 0.25 100mm 0.23 125mm 0.21 Good workmanship and appropriate site procedures are necessary to achieve expected performance. The information contained in this publication is, to the best of our knowledge, true and accurate but any recommendations or suggestions which may be made are without guarantee since the conditions of use are beyond our control. Xtratherm reserve the right to change the content of this publication without prior notice. Xtratherm UK Limited Park Road Holmewood Chesterfield Derbyshire S42 5UY Tel: 0371 222 1033 Fax: 0371 222 1044 Email: info@xtratherm.com Xtratherm Limited Kells Road Navan Co Meath Ireland Tel: 046 90 66000 Fax: 046 90 66090 Email: info@xtratherm.com XT/TF/UK/IRL/10-10