Characterization of the X-ray eye

Similar documents
Lecture 14. Point Spread Function (PSF)

Basler. Area Scan Cameras

Physics 441/2: Transmission Electron Microscope

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

Fig.1. The DAWN spacecraft

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Realization of a UV fisheye hyperspectral camera

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Basler. Line Scan Cameras

GRID AND PRISM SPECTROMETERS

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:

Encoders for Linear Motors in the Electronics Industry

Implementing and Using the EMVA1288 Standard

Digital Camera Imaging Evaluation

Performance testing for Precision 500D Classical R/F System

PHYS 39a Lab 3: Microscope Optics

MODULATION TRANSFER FUNCTION MEASUREMENT METHOD AND RESULTS FOR THE ORBVIEW-3 HIGH RESOLUTION IMAGING SATELLITE

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

ON-LINE MONITORING OF AN HADRON BEAM FOR RADIOTHERAPEUTIC TREATMENTS

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Basler pilot AREA SCAN CAMERAS

Untangling the megapixel lens myth! Which is the best lens to buy? And how to make that decision!

Color holographic 3D display unit with aperture field division

Alignement of a ring cavity laser

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

Technical Considerations Detecting Transparent Materials in Particle Analysis. Michael Horgan

How To Understand Light And Color

Fast Varifocal Lenses Based on KTa 1-x Nb x O 3 (KTN) Single Crystals

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

Thin Lenses Drawing Ray Diagrams

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation

The accurate calibration of all detectors is crucial for the subsequent data

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

Wir schaffen Wissen heute für morgen

Basler scout AREA SCAN CAMERAS

Optical Design for Automatic Identification

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Understanding astigmatism Spring 2003

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Light and its effects

How To Use An Edge 3.1 Scientific Cmmos Camera

X-ray area detectors for synchrotron experiments Characteristics and Technologies

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Measuring Line Edge Roughness: Fluctuations in Uncertainty

Measuring the Point Spread Function of a Fluorescence Microscope

Physics testing of image detectors

Basler racer. Line Scan Cameras. Next generation CMOS sensors with 2k to 12k resolution and up to 80 khz line rate

RAY OPTICS II 7.1 INTRODUCTION

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Assessment of Camera Phone Distortion and Implications for Watermarking

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Synthetic Sensing: Proximity / Distance Sensors

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

E190Q Lecture 5 Autonomous Robot Navigation

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Radiography: 2D and 3D Metrics of Performance Towards Quality Index

X-ray thin-film measurement techniques

Lenses and Telescopes

RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND GRATINGS RESOLUTION CHARTS AND

Laue lens for Nuclear Medicine

ING LA PALMA TECHNICAL NOTE No Investigation of Low Fringing Detectors on the ISIS Spectrograph.

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Analysis of Blind Microvias Forming Process in Multilayer Printed Circuit Boards

MRC High Resolution. MR-compatible digital HD video camera. User manual

Does Quantum Mechanics Make Sense? Size

Chapter 17: Light and Image Formation

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

Scanners and How to Use Them

Theremino System Theremino Spectrometer Technology

Polarization Dependence in X-ray Spectroscopy and Scattering. S P Collins et al Diamond Light Source UK

A Guide to Acousto-Optic Modulators

The Trade-off between Image Resolution and Field of View: the Influence of Lens Selection

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Advances in scmos Camera Technology Benefit Bio Research

OCR and 2D DataMatrix Specification for:

The Basics of Scanning Electron Microscopy

Introduction to X-Ray Powder Diffraction Data Analysis

Telescope Types by Keith Beadman

Experiment 3 Lenses and Images

Computer Vision. Image acquisition. 25 August Copyright by NHL Hogeschool and Van de Loosdrecht Machine Vision BV All rights reserved

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

Remote RadEye Product Family

Understanding Line Scan Camera Applications

Digital Photography. Author : Dr. Karl Lenhardt, Bad Kreuznach

OmniBSI TM Technology Backgrounder. Embargoed News: June 22, OmniVision Technologies, Inc.

Acousto-optic modulator

Indirect X-ray photon counting image sensor with 27T pixels and 15 electrons RMS accurate threshold

Care and Use of the Compound Microscope

Optical laser beam scanner lens relay system

ELECTRON SPIN RESONANCE Last Revised: July 2007

DETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm

Image Formation in the Electron Microscope

Transcription:

Characterization of the X-ray eye Report by Willem Rischau Friedrich Schiller University Jena, Germany DESY Summer School 2009 21.07.2009-10.09.2009 1 Introduction Detectors for X-ray imaging can be realised in different ways, depending on the energy range, the requested spatial resolution and detective quantum efficiency. One way to realise an X-ray detector with a spatial resolution in the micrometer range is the combination of a single crystal scintillator, a light microscopy optics and a charged-coupled device (CCD). This work is about the characterization of such an X-ray camera or X-ray eye, whose setup is based on plans from M. Bordessoule at the SOLEI Synchrotron [4]. This camera will be part of the detector loan pool at HASYLAB and should be used later at PETRA III beamlines to find the synchrotron beam. Therefore, it should be fast and adaptable to different energies and resolutions. In this work, the spatial resolution of the optical system consisting only of the CCD camera and the microscopy objective was determined as well as the spatial resolution of the complete X-ray eye with installed scintillator screen. 2 X-ray detectors 2.1 Principles of X-ray detection The detection of X-rays is based in principle upon the creation of electron-hole pairs in a semiconductor or an electron-ion pair in a gas through different light-matter interactions like the photoelectric or the Compton effect. This can be realised in a detector in two different ways, either in indirect or direct detection. In indirect detection the X-ray photons are first converted into visible light photons by using a scintillator screen which then generate a signal in the sensor, whereas in direct detection the X-ray photons are directly converted into an electric signal by creating electron-hole pairs. The advantage of the indirect detection is the possibility to use commercial CCD cameras for the detection of the created visible photons whereas 1

2 X-RAY DETECTORS 2 direct detection can only be realised with X-ray sensitive cameras. The X-ray detector described and investigated in this work is based on indirect detection and basically consists of a scintillator screen, a light microscopy optics and a CCD Camera. With this design, a spatial resolution in the micrometer range can be achieved. The schematic setup of this kind of x-ray camera is shown in figure s c in tilla to r s c re e n o p tic a l s y s te m C C D X -ra y s z 0 z 0 + δz z Figure 1: Schematic setup of an X-ray camera consisting of a scintillator screen, a microscopy optics and a CCD camera. 1. The incoming X-ray photons create identical visible-light images in the different planes of the scintillator screen. If the CCD camera is focused on the plane at the position z 0 of the scintillator screen, all planes at the position z 0 + δz are out of focus at the CCD. Therefore, the spatial resolution of the camera decreases with increasing scintillator thickness. As the absorption of X-ray photons and therefore also the efficiency decreases with thinner scintillator thicknesses, one always has to find a compromise between spatial resolution and detector efficiency. 2.2 Determination of the spatial resolution The spatial resolution of an optical system, like a camera can be described by his impulse response to different sources. In the case of a point source or a point object, the response of the system is called point spread function (PSF). If an optical system is considered as a linear system, the image of two objects is given by the linear superposition of two independent images corresponding to the two objects.

2 X-RAY DETECTORS 3 Therefore, each image point can be considered as the weighted sum of the point spread functions corresponding to each point u in the object plane. Mathematically, the object signal can be expressed as a weighted sum over 2D delta-impulses: w in (u) = w in (u )δ(u u )du (1) with an impulse δ(u u ) at the point u in the object plane and a weighing function w in (u) depending on the object. The output signal and the image itself, respectively can then be described as w out (u 0 ) = w in (u)p SF (u 0, u)du, (2) where w out (u 0 ) is the output signal at the spatial position u 0 in the image plane and PSF(u 0, u) is the response of the system measured at point u 0 to an impulse δ(u u ) applied at u. If the point spread function PSF(u 0, u) is independent of the position u in the object plane, the system is called shift invariant. Often, the PSF of a linear system only depends of the difference of its two arguments. In case of an optic system, this is true if the image of a point source does not depend on the location of the point. In this case eq. (2) becomes a convolution or folding integral: w out (u 0 ) = w in (u)p SF (u 0 u)du. (3) As the experimental realization of a point source is very difficult, it is more convenient to measure the line spread function (LSF) or the edge spread function (ESF) of a system. While the LSF is the response of the system to a line source, the ESF expresses the systems response to a sharp edge, see figure 2. The spatial resolution of the system can be expressed by the width of the LSF or the ESF, i.e. the Full-Width-at-Half-Maximum (FWHM) of the LSF or sometimes the 10%-to-90% distance of the edge response. The advantage of the ESF is the easy experimental realization of an edge. As the two-dimensional derivative of an edge is a line, the LSF can be determined by deriving the edge response. Moreover, as a line source can be regarded as the integral of a point source, the one-dimensional derivative of the ESF in a certain direction is the PSF. Therefore, the spatial resolution of the system can be expressed by the FWHM of the PSF, derived from the measured ESF of the system. Another way to express the spatial resolution of an imaging system is the Modulation Transfer Function (MTF). The MTF is defined as the the ratio of the output modulation M out of the signal measured by the detector to the input modulation M in of the signal. This corresponds to the Fourier transform of the one-dimensional PSF (or alternatively the Fourier transform of the two-dimensional LSF): MT F = M out M in = F T {P SF } (4)

2 X-RAY DETECTORS 4 Figure 2: Line spread function (LSF) and edge spread function (ESF). While the width of the LSF is expressed by the FWHM, the width of the ESF is usually expressed as 10%-to-90% distance of the edge response[3]. The modulation or contrast of a signal is defined by M = w max w min w max + w min (5) with the maximum and minimum amplitude w max and w min, respectively. As the Fourier transform of an even function is again an even function, a symmetric PSF results in a symmetric MTF. This applies for example in the case of a Gaussian distributed PSF P SF (x) = exp [ 1 2 ( x σ ) 2 ] MT F (k) = exp [ 1 ] 2 (kσ)2 (6) with the spatial position x in the image plane, the wavevektor k and a standard deviation σ of the distribution. The MTF corresponds to the frequency response of the system, i.e. it indicates the response amplitude of the system as a function of the spatial frequency. The spatial resolution is then usually expressed as the frequency where the MTF is reduced to 10%. The spatial resolution can though be expressed in several ways, which provide different values. The FWHM of the PSF and the 10% value of the MTF do not correspond to the same value for the spatial resolution.

3 EXPERIMENTAL SETUP 5 3 Experimental Setup 3.1 X-ray eye The used X-ray eye (see figure 3) was constructed according to plans from M. Bordessoule at the SOLEI Synchrotron [4]. The camera uses a 45 mirror, so the incoming X-rays form a 90 angle with the optical axis of the microscopy optics and the CCD. The CCD camera used for the measurements on the following pages is a Prosilica GC 650 with a pixel size of 9.9 9.9µm 2 whereas the camera setup shown in figure 3 uses the Basler Scout SCA640-74gm Gigabit Ethernet camera, which was used for some first tests until the Prosilica camera was available (for further explanation see chapter 5). The used objective is a Computar M5018-MP2 Megapixel Lens with a magnification of 1.8 and a 50mm focal length. For more information on the different parts and the camera itself, see [4]. The scintillator screen is a yttrium Figure 3: X-ray camera with a Basler Scout SCA640-74gm Gigabit Ethernet camera. aluminium garnet Y 3 Al 5 O 12 (YAG) single crystal. Figure 4 shows the absorption coefficient of YAG for the two used scintillator thicknesses 100 and 200µm. 3.2 Measurement of the spatial resolution To determine the spatial resolution of the optical system, consisting out of the microscope objective and the CCD camera, the point spread function was measured by illuminating a sharp edge with a red LED. In order to move the LED very close to the edge, the originally round head of the LED was filed down to a plane shape. The edge itself was realised with a thin piece of tantal foil with a polished edge, which was then glued to a microscopy cover glass. The prepared cover glass was then installed in the camera in the focus of the camera, i.e. in the position of the scintillator screen. The LED could be moved using a micrometer translation device. After a picture with the edge, the LED was moved and the cover glass with the glued edge was removed and exchanged for a normal cover glass. After this, the LED was moved back in the starting position and a second picture was taken under

3 EXPERIMENTAL SETUP 6 1,0 0,9 0,8 a b s o rp tio n 0,7 0,6 0,5 0,4 0,3 1 0 0 µm Y A G 2 0 0 µm Y A G 0,2 5 0 0 0 1 0 0 0 0 1 5 0 0 0 2 0 0 0 0 2 5 0 0 0 3 0 0 0 0 % (? X ) Figure 4: Absorption coefficient of yttrium aluminum garnet Y 3 Al 5 O 12 (YAG) for a crystal thickness of 100 and 200µm. the same conditions. This picture was used to determine the flat field to account the different sensitivity of the pixel as well as the influence of the source. Another picture was taken with the closed lens cap to determine the dark current. Each image was therefore normalized, i.e. first the dark current was subtracted from the image (with edge) and the flat field image (without edge) and then the image itself was divided by the flat field image. The spatial resolution of the complete X-ray eye was measured in a similar way with X-rays using a fine focus X-ray tube with Mo target (anode voltage U = 30keV ) and a collimator system so that the effective source size is small compared to the spatial resolution. This time, the edge was fixed on the scintillator screen. The CCD camera was used with the Prosilica Sample Viewer, the evaluation of the pictures was done with an IDL software written by Michael Lohmann.

4 MEASUREMENTS 7 4 Measurements 4.1 Spatial resolution of the optical system The spatial resolution of the optical system of the x-ray eye was measured with a CCD exposure time of 3s and a LED illumination period of 8ms. Figure 5 shows the taken pictures with and without the edge. The corresponding edge spread function, Figure 5: Images of the LED without (left) and with (right) the edge for an CCD exposure time of 3s and a LED illumination peroid of 8ms. the point spread function (one dimensional line spread function) and the modulation transfer function are shown in figures 6 and 7, respectively. A spline interpolation calculate points at 10nm distances from the measured ESF, the PSF was derived from the interpolated ESF and finally a Gauss function (see eq. 6) was fitted on the PSF. The determined spatial resolution, corresponding to the frequency where the MTF is reduced to 10% is 55 lines per millimeter corresponding to 18µm.

4 MEASUREMENTS 8 Figure 6: Measured and fitted (dashed-dot line) ESF, derived PSF and fitted Gaussian distribution (dashed line). Figure 7: MTF, derived from the fit of the PSF and the Gaussian distribution shown above in figure 6.

4 MEASUREMENTS 9 4.2 Spatial resolution of the X-ray eye Figure 8 shows the measured and fitted PSFs and MTFs respectively for the 100 and the 200µm scintillator. The results for the spatial resolution of the complete X-ray determined from these figure as well as the spatial resolution of the optical system are given in table 1. Figure 8: Top: Measured and fitted (dashed-dot line) ESF and the derived PSF and fitted Gaussian distribution (dashed line) for the 100µm left and the 200µm right single crystal scintillator for a CCD exposure time of 60s to the X-rays. Bottom: Corresponding MTFs. The shown ESF curves are smoothed by factor 2. System FWHM of the PSF [µm] 10 % of MTF [lp/mm] 10 % of MTF [µm] optical system 14 55 18 100µm YAG 21 41 24 200µm YAG 51 16 63 Table 1: Spatial resolutions of the optical system of the X-ray eye and of the complete X-ray eye with the 100 and the 200µm YAG scintillator screen.

5 SUMMARY 10 5 Summary In this work, I characterized an X-ray eye, which should be used as a beamfinder at PETRA III beamlines. This included the determination of the spatial resolution of the optical system, consisting of a CCD camera and a microscopy optics as well as the spatial resolution of the complete X-ray eye with installed scintillator screen. This was done by measuring the systems response to a sharp edge, illuminated with a LED and X-rays, respectively. The result for the spatial resolution corresponds to the 10% value of the modulation transfer function, which was obtained by deriving the measured point spread function. The result for the optical system is lying in the range of 20µm, which is larger than the expected resolution for this setup. This could be due to the use of the LED, i.e. a too inhomogenous light source or a not accurate enough focus of the camera on the used edge. The spatial resolution for the complete X-ray eye is in the range of 20 and 60µm for a 100 and 200µm YAG scintillator screen, respectively All results in this work were obtained with the Prosilica GC 650 camera. At the beginning of this work, only the colour version of this camera was available. Tests with this version showed however, that it is not possible to obtain raw uninterpolated data from each pixel. This made it impossible to use the colour version for the determination of the spatial resolution, as the expected resolution lies in the same range as the pixel size. The spatial resolution of the optical system was also determined with another CCD camera, the Basler SCA640-gm. Both cameras have similar features, but the LINUX drivers of the Basler camera do not work with the LINUX version at DESY and it is impossible to obtain images with more than 8bit using the Basler software Pylon Viewer. 6 Acknowledgements First, I would like to thank DESY for allowing me to get an insight into the life at a big research facility. Special thanks goes to my supervisor Michael Lohmann for his help, anytime I needed it.

REFERENCES 11 References [1] T. Martin, A. Koch: Recent developments in X-ray imaging with micrometer spatial resolution, J. Synchrotron Rad. (2006) 13 180-194 [2] H.H. Barrett, W. Swindell Radiological imaging: the theory of image formation, detection, and processing, Volume 1 Academic press of the university of Michigan (1981) [3] S.W. Smith: The Scientist and Engineer s Guide to Digital Signal Processing, www.dspguide.com. [4] M. Bordessoule: Caméra à grandissement 1 pour ODE. Caméra à 90 du faisceau X, (2007)