Appendix A. Cabling the 3512 DSU/CSU. Introduction. Caution. Connecting Your 3512 to Data Terminal Equipment (DTEs) Appendix A

Similar documents
Cable Specifications and Information

Cable Pinouts. SRP I/O Module

RS-232 COMMUNICATIONS

Cable Specifications. T3 Trunk Cabling APPENDIX

Cable Specifications and Information

Connectors and Cables

Connecting Serial Interface Cards to a Network

Cable Connection Procedures for Cisco 1900 Series Routers

Cabling Guide for Console and AUX Ports

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Administrative Council for Terminal Attachments (ACTA) Customer Information

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

How To Set Up An Ipad Dsu/Csu With A Power Adapter And Power Cable (I2) With A Dsu Or Csu (Dsu) With An Ipa (Dsi) With Power Adapter (Dse)

Connector and Cable Specifications

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Connector and Cable Specifications

Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Cable Guide For all PortServer TS, Digi Connect, and Digi One Products

Cabling LANs and WANs

RS-232 Cables, Wiring and Pinouts. Brief tutorial and pinouts for RS-232, T1/E1 and V.35. Contents

Comtrol Cable User Guide

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications

Application Note 83 Fundamentals of RS 232 Serial Communications

Module Connectors and Cable Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

Application Note: Extending a TSP s Analog Capabilities Using an Access Bank I

Digital T1/E1 PCI (HMP) Board

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Dialog Telephone Interface Module Installation Sheet

Is Your Interface a DTE or a DCE?

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Cable Specifications

OVERVIEW NETWORK INTERFACE MODULES

Imecom White Paper. T1/PRI Configuration for the Imecom DM Fax Server with Brooktrout TR1034 Digital Fax Board(s)

Encore Controller to Router Connections

FOM-5A, 6A. Asynchronous Fiber Optic Modem

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

2-Port RS232/422/485 Combo Serial PCI Card

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

PROPRIETARY INFORMATION NOTICE

Power, Cable, and Antenna Connection Procedures

Ethernet Patch Cord Wiring

Advanced Data Capture and Control Systems

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

1-Port R422/485 Serial PCIe Card

Making a DB to RJ45 adapter.

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)

NT1 Type 400. NT1 Type 400 Standalone L1 NT1 Type 400 Circuit Pack USER MANUAL

RS232 Data Interface a Tutorial on Data Interface and cables

SyncLink GT2/GT4 Serial Adapter

Configuring Serial Interfaces for E1- and T1-Carrier Lines

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

PagePac PAGEPAL V

These highly flexible interface cards facilitate several important applications:

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Telephone- and leased line modem for industrial applications TD-36

Cabling Specifications

How To Use A Comsphere 3920Plus Modem

Should still mention E1 since it is mentioned above maybe something like E1 lines can be supported under special arrangement.

Model 70A00-1. GSM Cellular Communications Center

RJ11 RS-232 Interface

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

User Manual IC-485AI

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

TNE1500-P and TNE1500-S T1 Network Extenders Installation Instructions

Serial Cables & Adapters

RS-232/422/485, Power over Ethernet

Hotwire 6350 ReachDSL Modem Overview

DWIatt2 USER'S GUIDE

Telebyte 209 Short Haul Modem

2/4/8 Port USB to Serial Adapter Hub with COM Retention

VOICE RECORDING SYSTEM ISDN PRI / BRI

Hotwire 6310 MVL Modem with Inline Phone Filter Installation Instructions. Contents. Hotwire 6310 MVL Modem Overview

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

Overview of the Cisco 2500 Series Access Server

Manual Serial PCI Cards

XPort Universal Demo Board User Guide

UIM-2T1 T1 Loop Bonding Uplink Interface Module

1 Port FTDI USB to RS232 Null Modem Adapter

1 Port RS232 Serial over IP Device Server

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

isco Connecting Routers Back to Back Through the AUX P

Rack mounted telephone- and leased line modem for industrial applications

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

PRISM 3001 FT1/T1 CSU/DSU

Zypcom Application Note

GEU Port Gigabit Switch

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

DV-1D Data/Voice DSU TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...8 SECTION 3 - INSTALLATION...11

Cisco 2500 Series. Product Overview. Key Features and Benefits. Specifications. Hardware

Perle 10/100 Ethernet Media Converters

Transcription:

Appendix A Cabling the 3512 DSU/CSU Introduction This appendix describes the cables needed to connect your 3512 DSU/CSU to DTEs, leased lines, dial lines, and a Network Management System, and it describes port, connector, and cable interfaces and pinouts. Connecting Your 3512 to Data Terminal Equipment (DTEs) Tables A-1 and A-2 show the most common applications and cables used with the 3512. For more information, contact your Motorola representative. NOTE: For DTE cable pinouts, refer to your DTE manual. Caution EIA 232-C/D computer interface cables connected to a 3512 DSU/CSU must be braided, shielded cables with metal, shielded hoods to ensure compliance with FCC and CISPR requirements relative to emitting Radio Frequency Interference (RFI) to other sensitive electronic equipment. Contact your authorized Motorola sales representative to determine which cables are appropriate. Table A-1. Common 3512 DSU/CSU Cables for Port 1 Application Electrical Interface Type: DB25 (m) to... Product Code Length DCE to DTE EIA 232 DB25 (f) straight-through adapter 31037 15 ft DCE to DTE EIA 232 DB25 (m) straight-through adapter 66186 15 ft DCE to DCE EIA 232 DB25 (m) crossover 31034 15 ft DCE to DTE V.35 V.35 (f) straight-through adapter 48523 6 ft DCE to DTE V.35 V.35 (m) straight-through adapter 77999 6 ft DCE to DCE V.35 V.35 (f) straight-through adapter, and V.35 (m) to V.35 (m) crossover 48523 89260 6 ft Appendix A Cabling the 3512 DSU/CSU A-1

Table A-2 shows communications cables for Ports 2, 3, and 4. Table A-2. Common 3512 DSU/CSU Communications Cables for Ports 2-4 Application Electrical Interface Type Table A-3 shows telco cables that connect the 3512 to DDS wall jacks. Product Code DCE to DTE EIA 232 DB26 (m) to DB25 (f) straight-through adapter 26975 92075 DCE to DTE EIA 232 DB26 (m) to DB25 (m) straight-through adapter 92035 15 ft DCE to DCE EIA 232 DB26 (m) to DB25 (m) crossover adapter 48043 DCE to DCE EIA 232 DB26 (m) to DB26 (m) crossover adapter 26977 5 ft DCE to Digital SW56 V.35 (Port 2 only) DCE to DCE Data Unit EIA 232 (Port 2 only) DB26 (m) to V.35 (m) crossover to switched digital restoral unit DB26 (m) to DB25 (m) A/B switch crossover to restoral unit DB26 refers to the EIA 232-D Alternate 26-pin (subminiature) connector. Table A-3. 3512 DSU/CSU - Service Provider Cables 48032 or 48039 Length 5 ft 10 ft 1 ft 5 ft 48038 1 ft Product Code From Product: To: 6 ft 15 ft 30 ft 50 ft DDS Line Port DDS Network (Mod-6) 1 77965 DDS Network (Spade) 48601 DDS Network (RJ48S Mod-8) 26965 1 6-pin modular is mechanically, but not electrically, compatible with RJ11 PSTN connector Table A-4 shows cables that connect the 3512 NC IN and NC OUT ports to an NMS. Table A-4. 3512 DSU/CSU Cables to Network Management System Product Code From Product: To: 6 ft 15 ft 30 ft 50 ft NC IN Port (f, 8-pin DIN, DCE) NC OUT Port (f, 8-pin DIN, DTE) 9300 Junction Box (SDL8) DTE 92199 DB25 (f) 40385 40387 40388 DB26 (f) 40386 40389 40390 3512 NC IN (f, 8-pin DIN, DCE) 40380 40381 40382 A-2 Cabling the 3512 DSU/CSU

Table A-5 shows cables that connect the 3512 restoral feature to a service-provider wall jack. Table A-5. 3512 DSU/CSU Integral Restoral Interface Cables Product Code From Product: To: 6 ft 15 ft 30 ft 50 ft SLR RJ45S Mod-8 (ALT) Dial Line (Mod-6) 1 99068 Dial Line (RJ45S Mod-8) 26967 SW 56 (or DDS) RJ48 Mod-8 (ALT) 4-wire SW 56 or DDS Network: (RJ48S) (Spade) (Mod 6) 1 26967 48601 77965 1 6-pin is mechanically, but not electrically, compatible with the RJ11 PSTN connector. Table A-6 provides information for ordering network connections and DDS lines. Table A-6. Communications Line and Service Ordering Information Interface USOC Jack Connector REN/Service Code Facility Interface Code 2.4-kbps digital interface RJ48S 6.0F 04DU5-24 4.8-kbps digital interface RJ48S 6.0F 04DU5-48 9.6-kbps digital interface RJ48S 6.0F 04DU5-96 19.2-kbps digital interface RJ48S 6.0F 04DU5-192 56-kbps digital interface RJ48S 6.0F 04DU5-56 Public Switched Digital Service (PSDS), for SW 56 feature: 56-kbps digital interface RJ48S PSDS Type 1 Public Switched Telephone Network (PSTN), for SLR feature: Permissive RJ11C 0.2B 02LS2 Programmable RJ45S or RJ41S 0.2B 02LS2 Cabling the 3512 DSU/CSU A-3

Table A-7 provides information required when ordering network connections and telephone lines. Table A-7. Telecommunications Regulatory-Ordering Information Country 3512 DSU/CSU Data Item Value U.S. FCC Registration Number AT9USA-61595-DD-N U.S. Ringer Equivalence Number (REN) 0.2B Canada Load Number for 3512 with SLR 4 Canada DOC Certification Number 725 5221 A Canada Connection Arrangement Code CA45A In the U.S.A., the REN determines the number of devices that can be connected to a telephone line. Excessive RENs on a line may result in the devices not ringing in response to an incoming call. Contact the service provider to determine the maximum REN sum for the calling area; in general, it should not exceed five. In Canada, the Load Number assigned to each terminal device denotes the total load percentage to be connected to a telephone loop used by the device to prevent overloading. The loop termination can consist of any combination of devices as long as their total Load Numbers do not exceed 100. A-4 Cabling the 3512 DSU/CSU

Pin Interfaces Table A-8 shows the 3512 s port pinouts. Table A-8. DTE Connector Pinouts DB25 or DB26 (Ports 1-4) EIA/TIA 232-D V.35 1 Frame Ground Frame Ground 2 Transmit Data +Transmit Data 3 Receive Data +Receive Data 4 Request To Send Request To Send 5 Clear To Send Clear To Send 6 Data Set Ready Data Set Ready 7 Signal Ground Signal Ground 8 Carrier Detect Carrier Detect 9 Not used Not used 10 Not used Not used 11 Not used Not used 12 Not used Not used 13 Not used Transmit Data Clock 14 Not used Transmit Data 15 Transmit Data Clock +Transmit Data Clock 16 Not used -Receive Data 17 Receive Data Clock +Receive Data Clock 18 (Port 1 only) Loop 3 Control Loop 3 Control 19 Not used Receive Data Clock 20 Data Terminal Ready Data Terminal Ready 21 Loop 2 Control Loop 2 Control 22 Not used Not used 23 Not used External Transmit Clock 24 External Transmit Clock + External Transmit Clock 25 Test Mode Test Mode 26 Not used Not used NOTE: Port 1: DB25 connector; Ports 2-4: DB26 subminiature connectors Cabling the 3512 DSU/CSU A-5

Table A-9 shows how to connect the 3512 s DDS 8-pin RJ48S to an RJ11 wall jack. Table A-9. RJ48S to RJ11 Cable Pinouts RJ48S 8-Pin Modular Jack Description 1 Transmit (Ring) 3 2 Transmit (Tip) 4 7 Receive (Tip) 2 8 Receive (Ring) 5 RJ11 6-Pin Modular Wall Jack to PSTN Table A-10 shows the 3512 s ALT connector pinouts for SLR and SW 56 operation. Table A-10. Service Provider Connector Pinouts ALT Pin SLR Switched 56 1 Transmit (Ring) 2 Transmit (Tip) 3 4 Ring 5 Tip 6 7 PR Receive (Tip) 8 PC Transmit (Ring) Table A-11 shows NC IN and NC OUT port pin assignments. Table A-11. NC Terminal Interface Signal Pinouts (8-pin DIN Connector) Pin Signal Description 2 Transmit Data (TXD) Transmits serial digital data from DTE. 3 Receive Data (RXD) Serial digital data available to the DTE receiver. Uses async data; has no clock. 4 Request To Send (RTS) Active level to the DCE to transmit. Inactive level when transmission is not required. 7 Signal Ground Common signal and DC power ground (common return). 8 Data Carrier Detect (DCD) Active level from the DCE when a received input (analog) signal is detected. NOTE: The NC connector uses only the pins listed here. NC IN (DCE) NC OUT (DTE) A-6 Cabling the 3512 DSU/CSU