Tanking Protection System Components

Similar documents
BBA BRITISH. tanking. Application. Storage & Handling

Gas Membrane and Waterproof Tanking Systems

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

08 Visqueen Zedex cpt Dpc 12 Visqueen Zedex High bond Dpc 14 Visqueen preformed unit

WATERPROOFING FOR CONCRETE STRUCTURES

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

DELTA Premium Moisture Management Systems for Foundations.

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Rooflight INSTALLATION INSTRUCTIONS

SikaProof A Technology

WATERPROOFING OF WET ROOMS

SEAMS SEAMING USING SEAM TAPE

BLACK JACK ALL WEATHER ROOF COATING

Monarflex Tanking & DPM Systems. Cold and Hot. Applied. Structural. Waterproofing. Membranes YEAR. Geomembr nes WORLD LEADER IN WATERPROOFING

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Window Installation Instructions

The formation of roof waterproofing details calls for

GENERAL RUBBER LINING PRINCIPLES

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

GAS PROTECTION SYSTEMS

DIY CABINET REFACING INSTALLATION GUIDE

WELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

K2 STONE NATURAL VENEER

High Performance Solutions and Compounds for Roofing and Structural Waterproofing

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Asphalt Shingle Application Requirements

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Fosroc Proofex Engage

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

USER GUIDE Easier, Safer, Betta! WATERPROOFING

Wecryl Waterproofing System under surfacing supplied by others

Herringbone Pattern Flooring

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

DENSO WATERPROOFING SYSTEMS

Preprufe 160 Sheet Tanking and Waterproofing Membrane

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

WATERPROOFING SikaProof -A TECHNOLOGY

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

Please read the entire document before purchasing and installing any of these products

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Sikaflex Sealant Installation. Sika Corporation

LAYING BLOCK AND BRICK

GigaCrete Specification PlasterMax

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Composite Stone Veneer

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Puddle Flange. FRANK Puddle Flange

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Seamless Waterproofing. Systems

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Epdm Flat Roofing Systems

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

COATING & WRAPPING OF UNDERGROUND PIPING

INSTALLATION THE SIMPLIFIED VERSION

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

Division 9. SignaFlor Pad and Pour Flooring System

Your guide to home maintenance. Flat Roofs

CHAPTER 6 ASPHALT ROLL ROOFING

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Residential Roofing Guide

INSTALLATION GUIDE. americanwick.com WICK (9425)

ITEM THERMOPLASTIC MEMBRANE ROOFING

Hanson Building Products. precast basement solutions

UNIT 4: SHEATHING AND SHINGLING THE ROOF

How to build raised beds page

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

How to repair your existing low slope flat roof.

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Energy Company Obligation (ECO): Technical Monitoring Questions

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Grace Waterproofing Systems

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Transcription:

Page 1 Visqueen Tanking Protection Visqueen Building Products is recognised as a market leader in the development, production and supply of high quality construction related products for waterproofing below ground (tanking). The following components are used within the Visqueen Self Adhesive Membrane, Gas Resistant Self Adhesive Membrane, TorchOn Tanking and Urban Drainage Geomembrane (UDG) systems to ensure effective bonding, detailing and protection. Separate datasheets relating to the system membranes are available. System Components Visqueen Rigid Preformed Pipe Sleeve (Top Hat) Unit A black, rigid polyethylene preformed pipe sleeve unit, available for either 110mm or 135mm external diameter pipes. Pipe sleeve for effective waterproofing protection around service pipe penetrations. Ensure surfaces are clean and dry. Dress the tanking membrane to the base of the pipe. Apply Visqueen Zedex DPC Jointing Tape to the underside of the unit flange and the circumference of the pipe. Remove tape release paper, slide the unit over the pipe and bond to the membrane and pipe (Visqueen TorchOn Tanking requires the sanded surface to be prepared by pre-torching the surface of the membrane). Apply pressure to the jointed area to ensure adhesion. Apply a 200mm strip of the tanking membrane equidistant over the unit flange/membrane lap. Apply pressure to ensure adhesion. Apply a 200mm strip of the tanking membrane around the unit upstand/pipe lap. Apply pressure to ensure adhesion and secure with a mechanical fastening clip. When using a gas torch, ensure the flame is directed away from the pipe and pipe sleeve unit during installation. Visqueen Flexible Preformed Pipe Sleeve (Top Hat) Unit A black, flexible polyethylene preformed pipe sleeve unit, supplied to suit pipe external diameter as required. Pipe sleeve for effective waterproofing protection around service pipe penetrations. Easy to trim on site. Ideal for pipes positioned close to each other or pipes tight against internal walls. Ensure surfaces are clean and dry. Dress the tanking membrane to the base of the pipe. Apply Visqueen Zedex DPC Jointing Tape to the underside of the unit flange and the circumference of the pipe. Remove tape release paper, slide the unit over the pipe and

Page 2 bond to the membrane and pipe (Visqueen TorchOn Tanking requires the sanded surface to be prepared by pretorching the surface of the membrane). Apply pressure to the jointed area to ensure adhesion. Apply a 200mm strip of the tanking membrane equidistant over the unit flange/membrane lap. Apply pressure to ensure adhesion. Apply a 200mm strip of the tanking membrane around the unit upstand/pipe lap. Apply pressure to ensure adhesion and secure with a mechanical fastening clip. When using a gas torch, ensure the flame is directed away from the pipe and pipe sleeve unit during installation. Visqueen Flexible Internal and External Preformed Corner Units Black, flexible polyethylene preformed corner units, supplied 150mm x 150mm x 150mm. Preformed units for effective waterproofing of internal and external corners when using Visqueen self adhesive tanking membranes. Ensure surfaces are clean and dry. Apply Visqueen Zedex DPC Jointing Tape to the underside of the unit and bond into position. Lap the self adhesive tanking onto the unit and apply pressure to ensure adhesion. Visqueen Heavy Duty Protection Board A 3mm thick, flexible and rot proof bituminous board, supplied in 1m x 2m sheets. For protection of tanking membranes against damage from backfill, following trades, and the process of positioning spacers and reinforcement prior to laying a reinforced concrete slab. In horizontal applications, boards are loose laid and closely butt jointed. To prevent lateral movement the boards should be over-taped with Visqueen Girth Jointing Tape applied equidistant over the junction. Ensure surfaces are clean and dry prior to application of tape. Apply pressure to the tape to ensure adhesion. In vertical applications, boards should be strip bonded to the tanking membrane with Visqueen Zedex DPC Jointing Tape and the joints over-taped with Visqueen Girth Jointing Tape applied equidistant over the junction. Ensure surfaces are clean and dry prior to application of tape. Apply pressure to the tape to ensure adhesion. Visqueen UDG Protection Board A 3mm thick, flexible and rot proof board, supplied in 1.22m x 2.44m sheets. For protection of urban drainage geomembranes or as medium duty protection for Visqueen tanking membranes. In horizontal applications, boards are loose laid and closely butt jointed. To prevent lateral movement the boards should be over-taped with Visqueen Girth Jointing Tape applied equidistant over the junction. Ensure surfaces are clean and dry prior to application of tape. Apply pressure to the tape to ensure adhesion. In vertical

Page 3 applications, boards should be strip bonded to the membrane with Visqueen Zedex DPC Jointing Tape and the joints over-taped with Visqueen Girth Jointing Tape applied equidistant over the junction. Ensure surfaces are clean and dry prior to application of tape. Apply pressure to the tape to ensure adhesion. Visqueen Zedex DPC Jointing Tape A black, double sided butyl mastic tape, supplied in 100mm x 15m rolls. Double sided adhesive tape for a variety of bonding applications including adhering protection boards to externally applied vertical tanking. Ensure surfaces are clean and dry. Apply tape, remove tape release paper and form bond as required. Apply pressure to the jointed area to ensure adhesion. When the weather is cold, store tape in a warm, dry place until required. is not recommended below 5C. Visqueen Zedex DPC Fixing Strip A semi-flexible black plastic strip, 2m long and 30mm wide. The strip is pre-drilled at approx 150mm centres (14 holes per strip). For securing the top edge of vertically applied tanking membranes to masonry units or concrete. Bond the vertically applied tanking membrane. Position the Visqueen Zedex DPC Fixing Strip approximately 5mm below the top edge of the tanking membrane and secure in position with Visqueen Zedex DPC Fixing Pins for Masonry to provide a permanent mechanical fixing. Visqueen Zedex DPC Fixing Pins for Masonry A grey plastic fixing pin with a central nail. Hammering the central nail into the body of the fixing expands the fixing securing it in the drilled hole. Supplied in a box of 50 pins. For securing the top edge of vertically applied tanking membranes to masonry units or concrete. Bond the vertically applied tanking membrane. Position the Visqueen Zedex DPC Fixing Strip approximately 5mm below the top edge of the tanking membrane. At one end of the Fixing Strip, drill a 6mm diameter hole (through the tanking) into the substrate, to a depth of 55mm, using the hole in the Fixing Strip as a guide. Insert the Fixing Pin through the Fixing Strip into the drilled hole and secure in position by tapping the central nail into the body of the fixing using a flat faced hammer. The barbed portion of the Fixing Pin will expand securing the Fixing Strip and tanking membrane in position. Repeat for each hole of the Fixing Strip. Visqueen HP Tanking Primer

Page 4 Visqueen High Performance Tanking Primer is a black, elastomeric bituminous priming solution designed to prepare surfaces prior to the application of Visqueen self adhesive and torch applied damp proofing and tanking membranes. The product is manufactured in the UK and supplied in 5L tins. Uses Visqueen High Performance Tanking Primer can be used to prepare a variety of substrates including metal, concrete, brickwork, blockwork and stonework. It significantly improves the bond of Visqueen self adhesive and torch applied damp proofing and tanking membranes and helps to ensure a long-term watertight finish. It is suitable for green concrete, damp surfaces or substrate temperatures below 5C. Visqueen High Performance Tanking Primer can be applied by brush or roller. Care should be taken to prevent splashes as primer will permanently stain porous surfaces. Surfaces must be smooth, clean, and free from contaminants such as dust, dirt, grease, lichen, frost, etc. Substrate temperature must be greater than -4C. Coverage rates on porous surfaces e.g. concrete is 6 8m./litre. Visqueen High Performance Tanking Primer will dry in 1 5 hours depending upon temperature, surface porosity and ventilation. Wait until primer is tack free. The primer will be resistant to light rainfall almost immediately after application. Allow to dry fully before application of waterproofing membrane. Avoid pouring the primer directly onto a horizontal surface; use a dip tray. The primer should not be allowed to puddle during application as this will increase drying time. All tools can be cleaned after use with white spirit. Priming should be limited to an area that can be covered with membrane in 24 hours. Areas that accumulate significant amounts of dust or dirt must be re-primed before membrane application. When used on green concrete or damp surfaces, moisture may become trapped under the membrane which may result in blistering, particularly in warm, sunny weather. To reduce this risk, the membrane should be covered as soon as possible after application.

Appendix A Visqueen Building Products Visqueen is the market leader in the manufacture and supply of structural waterproofing and gas protection systems. Visqueen offers the complete package - a proven, reliable range backed by a technical support service that goes unmatched in the market - everything you would expect from a reputable and ethical company. System Accessories To ensure full waterproofing protection please use the following certified system components: Visqueen High Performance (HP) Tanking Primer Visqueen TreadGUARD1500 Visqueen Protect&Drain Visqueen Top Hat Unit Downloads Library Technical Datasheet Declaration of Performance Visqueen s Guide to CE Marking Find your local stockist Search our directory of Visqueen specification Stocking Centres to locate your nearest Visqueen Partner. Distributor Support Our specification Stocking Centres can access a free library of sales support tools, bespoke catalogues and more, click here. Technical support throughout your project We are specialists in our field and can help you specify the correct solutions with the necessary performance levels, in accordance with building regulations. Nationwide site support team Specification advice guidance & project sign off System design including CAD details