QIAcube Packing Instructions

Similar documents
Updating the QIAcube operating software

QIAsymphony RGQ Protocol Sheet

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

Overview menu: ArminLabs - DHL Medical Express Online-Pickup: Access to the Online System

HP SATA/SAS hard drive and Solid State Drive installation

Get the benefits of Norgren s unique range of Online services

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Dolphin 6500 Mobile Computer. with Windows CE 5.0. Quick Start Guide

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Quantum View Manage Administration Guide

QIAGEN Supplementary Protocol

Field Safety Notice Urgent Medical Device Correction C Cloudy Appearance and Potential Tears on System Drapes

Quantum View SM Manage Administration Guide

Configuring DHCP for ShoreTel IP Phones

Reporting practices for domestic and total debt securities

BT Premium Event Call and Web Rate Card

5big Backup Server. Quick Start Guide. Backup Appliance. Gigabit Ethernet DESIGN BY NEIL POULTON

FOCUS ON THE ENVIRONMENT

relating to household s disposable income. A Gini Coefficient of zero indicates

Valves for Safety Applications

To install the I/O Module Board: 1. Remove AC power from decoder.

The Role of Banks in Global Mergers and Acquisitions by James R. Barth, Triphon Phumiwasana, and Keven Yost *

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

Small form factor bay converter and hard drive installation

CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000)

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

MANDATORY PROVIDENT FUND SCHEMES AUTHORITY

[NUGENESIS SAMPLE MANAGEMENT ] AMPLE IMPROVING LAB EFFICIENCY, ANAGEMENT ACCELERATING BUSINESS DECISIONS. bigstock.com $69

Cell Sorting. S3e Cell Sorter Quick Guide

Hong Kong s Health Spending 1989 to 2033

DRAM Memory Modules. Pentium (Use gold-plated SIMMs) Memory Module

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Report on Government Information Requests

1.5 GHz Active Probe TAP1500 Datasheet

Cisco IT Data Center and Operations Control Center Tour

Agilent FieldFox Remote Viewer

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

High-Speed Inter Connect (HSIC) Solution

Release Notes: PowerChute plus for Windows 95 and Windows 98

How To Service A Paper Shredder

How does a venture capitalist appraise investment opportunities?

Report on Government Information Requests

Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings

Image Lab Software for the GS-900 Densitometer

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

Record Cleaning Machine

Norton Ghost How to copy partitions from an HDD to a Samsung SSD

cardscodes PRICE_LIST_MSG_ PRICE_LIST_MSG_2

Installation & Operation Manual. Type 1801 External Seahorse Pantograph Wiper. without Control System

Wat verwacht de hybride consument van de verschillende distributiesystemen? Jan Verlinden Insurance Leader Belgium Capgemini

5big Backup Server. Quick Start Guide. Backup Appliance. Gigabit Ethernet DESIGN BY NEIL POULTON

BUX48 High Power Bipolar Transistor

Boston Scientific Spinal Cord Stimulation (SCS) Systems

QuickSpecs. HP Wireless Keyboard and Mouse. Models

HP 22-in-1 Media Card Reader

THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

Kurzweil KORE 64. ROM Expansion Board for the PC3 and PC3K

Supported Payment Methods

Replacing the Gateway M320 Keyboard

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

Schedule R Teleconferencing Service

Supported Payment Methods

The Path Forward. International Women s Day 2012 Global Research Results

EW7031/EW7032-2,5 SATA/eSATA Hard Disk Enclosure

Waterpik Water Flosser

Report on Government Information Requests

Table of Contents. Conferencing Basics 3. Ready Bridge Set Up Options 4. Call Control Features 5. Security Features 6. Call Control Commands 7

PCI Express 1.0 (2.5 GT/s) Protocol Test

World Consumer Income and Expenditure Patterns

Replacing the Gateway M675 Keyboard

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

Computer Specifications

Features: Characteristic Symbol Rating Unit. Collector-Emitter Voltage V CEO 100 Collector-Base Voltage I C

Lexmark E260, E260d, and E260dn Series. Maintenance Guide

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

Agilent P940xA/C Solid State PIN Diode Switches

Packard Bell Easy Repair

Agilent E5063A ENA Series Network Analyzer

OWNER S MANUAL Table Tennis Table Patent Pending

Comparative tables. CPSS Red Book statistical update 427

How To Get A New Phone System For Your Business

A free call from your Roadpost satellite phone: A free call from North America:

MagIC Installation Manual. Point of Sales Terminals TD06014B

Investor Presentation Q4 2015

GLOBAL EDUCATION PROGRAM (GEP)

Global AML Resource Map Over 2000 AML professionals

KEYPAD LOCK RETROFIT KIT

Meetings. on call. The two popular Audio Conferencing options. Audio Conference. user guide

Replacing a toner cartridge. Removing a toner cartridge. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration.

THE ETHICS HELPLINE Worldwide Dialing Instructions April 2012

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

.com. Table of contents. Fax to

Transcription:

QIAcube Packing Instructions This document describes how to pack the QIAcube before shipping. The packaging should protect the instrument and must be in accordance with these packing instructions. These instructions supersede the information given in Section 4.5 of the QIAcube User Manual, version 1.1 June 2008. Important points before starting Packing and labeling will be checked by QIAGEN to ensure that they are in accordance with these packing instructions. QIAGEN reserves the right to return inadequately packed articles to the sender. If you have any questions about this procedure, contact QIAGEN Technical Services or you local distributor (see the back cover of any QIAGEN handbook or visit www.qiagen.com). Things to do before starting Make sure that the QIAcube is not in use before starting this procedure. Remove reagents and labware from the instrument, clean the worktable, and empty the waste drawer before starting the procedure. The QIAcube must be decontaminated before shipping. For detailed instructions, see Section 6.5 on page of the QIAcube User Manual. Procedure 1. Collect the materials required for packing the QIAcube: Foam rotor-protection disk for the centrifuge Foam transport lock for the robotic arm QIAcube pallet with 4 small foam corners QIAcube cardboard carton Two large foam corners Foam lid (with compartment) Compartment cover Tape Edge protectors and packaging straps (if available) Shipping labels Shipping documents QIAcube Packing Instructions (Nov-09) page 1 of 7

QIAcube cardboard carton Large foam corners Pallet with 4 small foam corners Edge protectors Compartment cover Foam lid 2. Make sure that the QIAcube door is closed and switch on the QIAcube. 3. If the centrifuge lid is not already open, open it as follows: Press Tools in the main menu. Select Maintenance by pressing or to scroll through the list until it is highlighted, and press Select. Select Open lid by pressing or to scroll through the list until it is highlighted, and press Select. 4. Open the QIAcube door. 5. Carefully place the foam rotorprotection disk on top of the centrifuge rotor. QIAcube Packing Instructions (Nov-09) page 2 of 7

6. Gently press the foam rotor-protection disk down onto the rotor until resistance is felt. 7. Close the QIAcube door. 8. Close the centrifuge lid as follows: Press Tools in the main menu. Select Maintenance by pressing or to scroll through the list until it is highlighted, and press Select. Select the protocol Close lid by pressing or to scroll through the list until it is highlighted, and press Start. 9. Switch off the QIAcube and disconnect the power cord. 10. Open the QIAcube door and insert the foam transport lock into the front of the instrument. QIAcube Packing Instructions (Nov-09) page 3 of 7

11. Press the foam transport lock down between the centrifuge and the robotic arm. 12. Push the foam transport lock until the rear of the transport lock touches the back wall of the instrument. Ensure that the robotic arm is held firmly in place and cannot move. 13. Make sure that the QIAcube door can be closed properly. The door should lightly brush against the foam. QIAcube Packing Instructions (Nov-09) page 4 of 7

14. Place the documents to be returned into the drawer. Packing list QIAcube quick-start guide QIAcube installation guide QIAcube loading chart 15. Place accessories into the drawer. The following accessories should be packed in air cushion bags: Rotor key USB stick Allen key Shaker rack plugs (set with 12 pieces) Shaker adapter (S2) WARNING Risk of personal injury and material damage The QIAcube is too heavy to be lifted by one person. To avoid personal injury or damage to the instrument, do not lift the instrument alone. 16. Lift the QIAcube and place it onto the pallet. At least 2 people are required to lift the QIAcube onto the pallet. When lifting the QIAcube, slide your fingers under both sides of the workstation and keep your back straight. Note: We recommend wearing work gloves. 17. Gently place the QIAcube into the foam corners at the edge of the pallet. 18. Place the cardboard carton over the QIAcube. Be sure the cardboard carton fits around the foam corners at the edge of the pallet. QIAcube Packing Instructions (Nov-09) page 5 of 7

19. Slide the two large foam corners into the cardboard carton so that they are at the front of the QIAcube. Place the foam lid on top of the QIAcube. Note: The carton was removed in the photo at the left to show how the foam protectors are inserted. 20. Place accessories to be returned into the compartment in the foam lid. Place the compartment cover on top of the compartment. The following accessories should be packed in air cushion bags: Power cords QIAcube User Manual (CD or print version) Tape 21. Seal the outside edges of the carton with tape to protect against moisture. QIAcube Packing Instructions (Nov-09) page 6 of 7

22. Remove old shipping labels and affix new labels to the carton. 23. Secure the cardboard carton to the pallet with edge protectors and packaging straps, if available. Affix the shipping documents to the side of the carton. Edge protectors For up-to-date licensing information and product-specific disclaimers, see the respective QIAGEN kit handbook or user manual. QIAGEN kit handbooks and user manuals are available at www.qiagen.com or can be requested from QIAGEN Technical Services or your local distributor. Trademarks: QIAGEN, QIAcube (QIAGEN Group). 1059594 11/2009 2008 2009 QIAGEN, all rights reserved. www.qiagen.com Canada 800-572-9613 Ireland 1800 555 049 Norway 800-18859 China 0086-21-3865-3865 Italy 800-787980 Singapore 65-67775366 Denmark 80-885945 Japan 03-6890-7300 Spain 91-630-7050 Australia 1-800-243-800 Finland 0800-914416 Korea (South) 1544 7145 Sweden 020-790282 Austria 0800/281010 France 01-60-920-930 Luxembourg 8002 2076 Switzerland 055-254-22-11 Belgium 0800-79612 Germany 02103-29-12000 Mexico 01-800-7742-639 UK 01293-422-911 Brazil 0800-557779 Hong Kong 800 933 965 The Netherlands 0800 0229592 USA 800-426-8157 Sample & Assay Technologies