Guidelines for the Construction of Low Flow Bypass Devices

Similar documents
Outlet stabilization structure

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

Emergency Spillways (Sediment basins)

Storm Drain Inlet Protection - IP

Stormwater/Wetland Pond Construction Inspection Checklist

City of Shelbyville Site Inspection Checklist

Watershed Works Manual

Permeable Pavement Construction Guide

Table 4.9 Storm Drain Inlet Protetion Applicable for

BMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.

Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile

SE-10 STORM DRAIN INLET PROTECTION. Objectives

Storm Drain Inlet Protection

Block and Gravel Inlet Protection (BIP)

Construction Site Inspection Checklist for OHC By making use of some simple Best Management Practices (BMPs) a construction site operator can

Storm Drain Inlet Protection for Construction Sites (1060)

LS 2540 SEWER LATERALS AND INSPECTION TEES

Storm Drain Inlet Protection

Minimizes sediment and debris from entering storm drains that lead to waterways and watercourses.

A perforated conduit such as pipe, tubing or tile installed beneath the ground to intercept and convey ground water. or structures.

WATER CONSERVATION TECHNICAL BRIEFS

DRAINAGE :: DRAINAGE CONCERN FREQUENTLY ASKED QUESTIONS

How To Build A Road Into A Lake In The North Of The Korean Island Of Hongkoon

SECTION 5 DRAFTING STANDARDS

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

Experiment (13): Flow channel

BRIDGES ARE relatively expensive but often are

4.3 Cisterns and Rain Barrels

SUSTAINABLE URBAN DRAINAGE SYSTEMS

STORMWATER MANAGEMENT CHECKLIST

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Homeowner s Guide to Drainage

Fabricated Drainage Products

CHAPTER 3 STORM DRAINAGE SYSTEMS

SC-07 STORM DRAIN INLET PROTECTION

Lecture 22 Example Culvert Design Much of the following is based on the USBR technical publication Design of Small Canal Structures (1978)

Storm Drain Inlet Protection for Construction Sites (1060)

Seattle Public Utilities. Natural Drainage Systems (NDS) Maintenance Manual

FY08 SEWER POINT REPAIRS BID TABULATION

Small Dam Hazard Assessment Inventory

PART 5 : WASTEWATER DRAINAGE

CLEANING, INSPECTION, AND TESTING OF SEWERS

CODE OF PRACTICE - VOLUME TWO - TRAIN SYSTEM [CP2] TRANSADELAIDE INFRASTRUCTURE SERVICES. Issue: 2 Date: 26/09/08 Page: 1 of 21

Specifications for Residential Property Owners Connection to New Public Sewer

CITY UTILITIES DESIGN STANDARDS MANUAL

1. Carry water under the canal 2. Carry water over the canal 3. Carry water into the canal

Final. Contact person: Colin Whittemore Aurecon Centre 1 Century City Drive Waterford Precinct, Century City Cape Town, South Africa

Temporary Erosion-Control Measures

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

16. Storm water drainage

Crossing creeks Stream crossings on farms

BMP 6.4.6: Dry Well / Seepage Pit

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

CHAPTER 11 STORM DRAINAGE

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18

Module 3. Irrigation Engineering Principles. Version 2 CE IIT, Kharagpur

Constructing Cistern Installations

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

PART 6 HA 113/05 DRAINAGE

Gas Meter Clearances and Service Installation Requirements

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Flash Flood Science. Chapter 2. What Is in This Chapter? Flash Flood Processes

Town of Elkton & Cecil Soil Conservation District Checklist for Joint Agency Review Stormwater Management / Erosion and Sediment Control

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

BMP #: Dry Wells / French Drains

Sample Micro Hydro Initial Report

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas

CHAPTER 11 STORM DRAINAGE

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SANITARY SEWER SPECIFICATIONS

SECTION 5. Sediment Control Measures

CHAPTER 3A Environmental Guidelines for STREAM CROSSING BY ALL-TERRAIN VEHICLES

Small Dam Repair The Stone Lake Dam Story. Joe Barron, P.E. SynTerra formerly the Fletcher Group, Inc. 148 River St. Suite 220 Greenville, S.C.

ITS specification Jointing chambers and pull pits (ITS-02-02)

40 ltr Domestic Grease Trap GTO ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Top 10+ Mistakes of DWV plumbing design

Siting and settlement: The most important way to protect shelter from floods is to build in a place that is unlikely to be flooded.

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

Moving Small Mountains Vesuvius Dam Rehab

Text and photos: Juha Siekkinen, Life+ Return of Rural Wetlands Cover drawing: Jari Kostet Maps and aerial photos: National Land Survey of Finland

How to build raised beds page

CERTIFYING DRAINLAYER

City of Regina Standard Construction Specification SECTION 1320 SEWERMAIN TESTING

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

SECTION STORM DRAIN SYSTEM

Downspout to storm sewer. Leaky laterals

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

Type of Sewer Systems. Solomon Seyoum

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Transcription:

TECHNICAL FACT SHEETS IN THIS SERIES Sheet 3a On-Stream Dams Sheet 3b Off-Stream Diversions Sheet 3c Off-Stream Diversion with a 50:50 Flow Split Small Weir to Divert Low Flows caption to go here Guidelines for the Construction of Low Flow Bypass Devices ON-STREAM DAMS WHAT IS A LOW FLOW BYPASS? A low flow by-pass is a device used to prevent a water storage, dam or other form of diversion from harvesting low flows (sometimes called environmental flows). These low flows are critical in maintaining our sensitive water dependant ecosystems. THRESHOLD FLOW RATE This is the rate of water flow which must be exceeded before water can be harvested or collected. It is normally measured in litres per second (l/s) and the required rate will be specified in your Water Affecting Activities Permit. WHEN DOES THIS FACT SHEET APPLY? Watercourses and dams or diversions have many forms. Three fact sheets have been prepared to cover most situations. These are: 1. On-stream dams (1 to 70 l/s) 2. Off-stream dams (10 to 520 l/s) 3. Off-stream dams with 50:50 flow split (5 to 2000 l/s) It is not anticipated that the design in this fact sheet will be appropriate for all dams. Some dams will require a special design to suit the local conditions. This fact sheet applies to on-stream dams with a flow threshold of between 1 and 70 l/s. Figure 2: Layout of a Typical Structure Diversion Pipe (buried) Dam Dam Wall Drainage Path Spillway Figure 1: Example of a Structure (buried) Small Weir to Capture Low Flows WHAT IS AN ON-STREAM DAM? An on-stream dam is constructed on or across a drainage path. The drainage path may be a defined watercourse with bed and banks or a less defined area where water flows in wet times. If the conditions detailed on this fact sheet cannot be met for your site, this design is not appropriate and you should either use other fact sheets or consult a qualified engineer to help you develop a special design. HOW DOES THE DEVICE WORK? The device collects low flows using a small weir. The weir directs low flows into a pipe and around the dam. The design of the weir, pipe diameter, pipe slope and flow control mechanism at the pipe inlet govern the amount of water diverted. During low flows water collects behind the weir where it is forced into the bypass pipe rather than flowing into the dam. As flow rates increase the water level behind the weir increases. At flows above the threshold flow rate the capacity of the weir and diversion pipe is exceeded, the weir overtops, and water enters the dam. DESIGN AND CONSTRUCTION These devices are formed using simple materials and can be designed and constructed by skilled handy-people or civil works contractors. A survey (dumpy) level and experienced user are required. Take care to follow the instructions closely. The guidelines have been developed to ensure the structure carries the correct flow and will be unlikely to block with sediment.

FUNCTIONAL DETAILS INTRODUCTION The device collects low flows using a small weir. The weir captures and directs low flows into a pipe and around the dam. The flow carrying capacity of the structure is set to match the threshold flow rate. At larger flows the capacity is exceeded, the small weir overtops and water enters the dam. The capacity of the structure is governed by the following factors: Pipe inlet flow control mechanism (orifice) Pipe diameter Pipe slope Weir design Guidance is provided on each of these factors and must be followed closely. PIPE INLET FLOW CONTROL MECHANISM Flow into the pipe is governed by an inlet flow control mechanism known as an orifice. An orifice is simply a round hole cut into the centre of an end cap placed on the inlet of the pipe. The flow through the orifice is closely related to the orifice diameter. This orifice provides accurate flow control. Use Figure 5 or 6 to determine your required orifice diameter, based on your required threshold flow rate. PIPE DIAMETER We recommend that you use Polypropylene (poly) pipe for the flow bypass device. Poly pipe is available in a number of standard diameters. Select pipe with an internal diameter at least 1.5 times larger than your required orifice diameter. Note that pipes are usually referred to according to their nominal diameter. This is usually slightly larger than the internal diameter. Check the availability of pipe diameters with your local supplier and ask for the internal diameter. You will also need to purchase an end cap for the pipe, in which to drill or cut the orifice. SMALL WEIR A small weir is used to capture low flows and divert them into the pipe. The key design issue with this weir is to provide the correct crest level being the level at which it is overtopped, allowing water to enter the dam. This crest level must be 30 cm, or 2 times the orifice diameter, whichever is greater, above the centre of the orifice. The weir structure includes a shallow pit in which the pipe inlet is placed, as shown in Figures 1, 2 and 8. This pit traps sediment preventing pipe blockages and allows for a lower weir which will be less likely to cause erosion. PIPE SLOPE Pipe slope is of critical importance to the functioning of the device. Incorrect slope will result in incorrect threshold flow rate and increased likelihood of sediment blocking the pipe. When laying the pipe it is important to get the slope as even as possible. Undulations should be avoided. Having said that, the best laid pipe will still have minor variations in slope along its length. It is the slope of the flattest section which is of most importance. This minimum slope must be above a certain value, which is dependant on the pipe diameter. Use Table 1 to select your minimum pipe slope based on your internal pipe diameter. Figure 3: Impoundment and Pipe Inlet Where Channel is Present Figure 4: Diversion Weir Details Levee Small Weir 1m x 1m wide Valley Floor 1m x 1m wide Small Weir Crest Level Orifice Channel Cross Section Orifice 10 cm Crest Level 10 cm Levee

DESIGN DIMENSION FIGURES AND TABLES Figure 5: Orifice Diameter versus Threshold Flow Rate (1 20 l/s) 140 120 Orifice Diameter (mm) 100 80 60 40 Example: For a threshold flow rate of 15 l/s, the orifice diameter is 115 mm. Minimum pipe diameter (internal diameter) is 173 mm. 20 0 5 10 15 20 Threshold Flow Rate (l/s) Figure 6: Orifice Diameter versus Threshold Flow Rate (20 70 l/s) 230 220 Orifice Diameter (mm) 210 200 190 180 170 160 Example: For a threshold flow rate of 60 l/s, the orifice diameter is 210 mm. Minimum pipe diameter (internal diameter) is 315 mm. 150 140 130 20 30 40 50 60 70 Threshold Flow Rate (l/s)

DESIGN DIMENSION FIGURES AND TABLES Table 1: Minimum Pipe Slopes Internal Pipe Diameter Minimum Pipe Slope % m per 100 m 47 mm 4 % 4 m per 100 m 60 mm 3 % 3 m per 100 m 71 mm 2 % 2 m per 100 m 86 mm 2 % 2 m per 100 m 105 mm 2 % 2 m per 100 m 119 mm 1 % 1 m per 100 m Example: For a pipe diameter of 300 mm the pipe must be installed at a slope steeper than 0.4%, or 40 cm fall in 100 m. 133 mm 1 % 1 m per 100 m 152 mm 1 % 1 m per 100 m 171 mm 1 % 1 m per 100 m 190 mm 0.5 % 0.5 m per 100 m 214 mm 0.5 % 0.5 m per 100 m 238 mm 0.5 % 0.5 m per 100 m 267 mm 0.5 % 0.5 m per 100 m 300 mm or greater 0.4 % 0.4 m per 100 m Note that internal pipe diameters vary slightly between pipe manufacturers and pipe structural grades. The table has been prepared based on internal pipe diameters from one manufacturer. Select the internal pipe diameter from the table which is closest to yours. Figure 7: Profile of Device showing Pipe Slopes Pipe Laid on Dam Spillway Flattest Section of Pipe Move pipe inlet further upstream from dam to increase pipe slope Small Weir Flow Dam Wall Dam Pipe Inlet (orifice)

STRUCTURAL DESIGN AND CONSTRUCTION INTRODUCTION Structurally speaking this type of low flow bypass is relatively simple and many aspects of the device can be designed and constructed according to local conditions and available materials. The key functional requirements have been outlined in earlier pages. This section gives guidance to assist with some other aspects of design and information to help with installation. PIPE SLOPE Pipe slope is of critical importance to the functioning of the device. Incorrect pipe slope will result in incorrect threshold flow rate and increased likelihood of the pipe blocking with sediment. No section of pipe can have a slope less than the minimum slope, as determined earlier using Table 1. When installed on existing dams, to meet this requirement the pipe inlet and small weir will need to be located some distance upstream of the dam. From this point the pipe should be laid at an even grade around the dam to the dam wall. The pipe should pass over the dam wall on top of the existing overflow spillway. See Figure 2 on Page 1. Before constructing the bypass, check the slopes using a survey (dumpy) level and tape measure. For a pipe laid at an even grade from its inlet to the dam spillway the slope is determined using the following equation: Height of Pipe Inlet above Dam Spillway (m) Slope (%) = x 100% Length of Pipe from Inlet to Dam Spillway (m) Don t forget to allow for bends or curvature in the pipe when measuring the length of pipe. If the pipe is laid unevenly, the calculated slope will be the average slope. Some sections will be flatter, and these must be steeper than the minimum slope. To increase the pipe slope, shift the pipe inlet further upstream from the dam. See Figure 7 on the previous page. Wherever possible, lay the pipe at a gradient steeper than the minimum slope. The survey (dumpy) level can also be used to mark the route of the pipe on the ground so that its at an even slope. In some very flat locations it may not be possible to achieve the minimum pipe slope. In these locations a special design will be required and you should consult a qualified engineer. For new dams the pipe may be laid through the dam and through the dam wall. Adequate seepage collars will be required to prevent piping failure of the dam wall. SMALL WEIR The small weir can be constructed from a variety of materials such as concrete and timber. The weir must be water tight (a strong, long life, UV resistant commercial grade plastic liner may assist) and provide the required crest level, as directed by guidance on previous pages. Where the dam is located on a watercourse where there is no defined channel, levees may need to be constructed across the valley to direct flows into the weir and pipe inlet. See Figures 4 and 8. These should extend across the drainage path ending at higher ground on either side of the valley, but should not increase the catchment area of the dam. The height of the levees should be determined based on local conditions. They should over top in high flows so that flows are not overly concentrated, causing erosion. A minimum height of 10 cm above the weir level is recommended. Compact well, sow grass on the finished levees and fence to prevent grazing and erosion of the levees SHALLOW PIT The shallow pit is used to collect sediment and prevent it entering the pipe. It also allows a lower weir crest level whilst still achieving the required height above the bottom of the orifice. A lower weir will be less likely to cause erosion associated with water cascading over the weir. The pit should be installed in the lowest point of the drainage path. The shallow pit may be formed with concrete, timber or bricks. It should be rectangular with a hard base (approximately 1 m x 1 m wide) and hard sides. It can immediately abut the weir or be set back slightly. The base level should be 10 cm below the bottom of the diversion pipe. Figures 1, 2 and 8 show the layout and recommended dimensions of the pit.

OTHER DESIGN AND MAINTENANCE ISSUES EROSION CONTROL AT WEIR Water cascading over the small weir is likely to lead to erosion on the downstream side of the weir. To prevent this, the bed of the watercourse channel or drainage path must be protected with rock for a length of 5 times the weir height. Rock protection must also extend up the banks to the height of the weir. Excavate the area to be rock protected to a depth of 30 cm and then fill this area with rock. Rock must have a range of sizes, with the average being about 200 mm in diameter. Some rock should be up to 300 mm in diameter and small rock/gravel should also be used to fill the gaps between bigger rocks. Rock must be hard and angular, not soft or rounded. Rock must be set into the creek bed rather than place upon it. Rock must be placed in such a way as to contain flows. The finished level of the rock must therefore be lower in the centre of the drainage path than at the edges. Encourage grass to grow over the rock by filling gaps in the rock with soil and casting seed over the finished area. BURY THE PIPE Standard grade poly pipe laid directly on the ground will be prone to crushing or damage by stock. If stock access the area the pipe must be buried. EROSION CONTROL AT PIPE OUTLET Water gushing out of the pipe outlet may also lead to localised erosion. It should be angled downstream and not directed at the banks. Ensure the pipe is held in place and unable to move about. One way to do this is to drive steel droppers either side of it and tie it to the droppers with strong wire. Where the dam spillway is stable and erosion resistant, the pipe outlet may be placed on the spillway. Otherwise the pipe outlet should be placed within the watercourse or drainage path, below the dam, at bed level. An energy dissipater must be constructed to prevent water gushing out of the pipe causing erosion. To make an energy dissipater construct a pit, similar to the inlet pit, in the base of the watercourse and place the pipe outlet in the pit. The pit should be at least 3 times as deep as the pipe diameter, or a minimum of 30 cm deep. It should be square with sides at least 5 times as long as the pipe diameter, or a minimum 1 m long. The pit may be formed with concrete, timber or bricks, but must be strong with no gaps in the walls or base. The pipe should pass through the upstream wall of the pit at base level. The pipe should be angled directly at the downstream wall of the pit. The end of the pipe should be at least 4 times the pipe diameter from the downstream wall of the pit. Figure 8: Layout of Small Weir,, Levees and Pipe Inlet (buried) Levee (if required) Rock protection downstream of weir. Length to be 5 times height of weir. Pipe Inlet (with orifice) Flow Drainage Path Drainage Path To Dam Weir Levee (if required) 1 m x 1 m wide Wire netting debris filter (if required)

For further information please: Contact us on: (08) 8391 7500 Visit us at: Upper Level, Cnr Mann & Walker Streets, Mount Barker SA 5251 Or go to our website: www.naturalreso urces.sa.gov.au OTHER DESIGN AND MAINTENANCE ISSUES MAINTENANCE The operation of the low flow bypass should be monitored and any issues addressed as they arise. Most importantly the device should be observed in operation during the first few flow events after installation and regularly thereafter. Attention should be paid to the following potential issues: Blockage of the pipe inlet with debris Blockage of the pipe with debris or silt Sediment accumulation in the shallow pit Leakage through the weir Erosion downstream of the weir Erosion at the pipe outlet Blockage of the pipe inlet orifice with debris (leaves, grass, sticks etc) may be an ongoing problem in watercourses with a high debris load. The restriction provided by the orifice should prevent the pipe blocking with debris. To reduce inlet blockage with debris, place a fence of wire netting (eg chicken wire) across the watercourse upstream of the shallow pit to trap debris. The netting should only be high enough to be effective in low flows, being overtopped in high flows. The fence will require cleaning on a regular, but less frequent basis. Sediment should be removed from the pit regularly to prevent it entering the pipe. This design has been prepared to minimise the likelihood of the pipe blocking with sediment. In the unlikely event that it does block it may be cleaned using commercial sewer cleaning equipment. Contact a contractor.