NATURAL STONE LABORATORY

Similar documents
Final Report. Commercial name of analysed material: Piedra Paloma. Requested by: Piedra Paloma S.L. January 2011 LABORATORIO DE PETROLOGÍA APLICADA

SPECIAL COMPOUND FOR RHEOPLASTIC AND ANTI-CORROSION SUPERCONCRETE WITH VERY HIGH DURABILITY

Construction Materials Testing. Classes of Test

Global Hybrid Roofing Solutions (Delaware) LLC

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

The AASHO Road Test site (which eventually became part of I-80) at Ottawa, Illinois, was typical of northern climates (see Table 1).

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule Levent- İSTANBUL/TÜRKİYE 07 EN

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

TSL Professional Services

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

SUPPORTED STANDARDS BY

TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2

Testing and appraisal of Lucobit polymer effect as an additive on asphalt mixture performance

4 Thermomechanical Analysis (TMA)

Dowel-Bar Retrofit Using Polyester Polymer Concrete

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Understanding BS EN 771-3: Aggregate concrete masonry units

Specifications, Product Testing and Terminology

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Annex of the certificate (Page 1/6) Accreditation Scope

BETONYP building boards. The modern way of living.

SITE INVESTIGATION FACILITIES

EDUCATIONAL GUIDE TO PROPERTIES OF MASONRY MORTAR

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

2. The mold is closed up and held under hydraulic pressure while the rubber material or compound cures.

WOOD PLANK DIGITAL PORCELAIN TILES

Specification N : NPS - 63/8. Underground Power Cable Covers

1.5 Concrete (Part I)

Nomex KD Technology. DuPont TM. DuPont s Heritage in Hot Gas Filtration Application. For over 4 decades, a filter media made of Nomex

Pavement Thickness. esign and RCC-Pave Software. Roller-Compacted Concrete Pavement: Design and Construction. October 24, 2006 Atlanta, Georgia

Durability of clay roofing tiles: assessing the reliability of prediction models

SECTION PLAYGROUND SURFACING TILES

SD-0150 GENERAL PURPOSE ABS (Acrylonitrile Butadiene Styrene) (TA)

Product Guide Specification

ENGINEERED QUARTZ STONE

The Concrete Life Cycle: Maintain to Sustain. Fred Goodwin BASF Construction Chemicals (EB-N) Beachwood OH

Physical Testing of Pulp and paper Method and service list June 2014

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Concrete CTE. AASHTO Joint Technical Committee on Pavements. Jackson Hole, WY May 27 28, 2009

Engineering Plastics Technical Presentation

PC-Concrete Injectable Concrete Anchoring and Repair System

STUDY OF THE BEHAVIOUR OF BITUMINOUS MIXTURES RESISTANT TO FUEL

Study of durability of sprayed concrete

European technical approval

September Author: Dipl.-Ing. K. Lehmann, FEhS Institut für Baustoff-Forschung e. V., Duisburg

Quality Assurance Concepts. Outline

The design process. Design life. Actions on structures. How to design concrete structures using Eurocode 2 2. Getting started

ETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

TIE-31: Mechanical and thermal properties of optical glass

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION

LE MARAIS Series White Body Wall Tiles

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

How To Determine The Effect Of Frost Deterioration On Chloride Penetration And Carbonation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Vip PORCELÁNICO FULL BODY

APE T CFRP Aslan 500

Condition assessment and repair of antenna towers concrete foundations

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Choosing the Right Mortar for the Job

Example Specification for Concrete using Current Building Code Requirements

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

Hardened Concrete. Lecture No. 14

Schedule of Accreditation Issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Concrete Repair. Applications and Procedures

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

Data sheets Material characteristics 1.2/1

digital floor 50x50 FLOORtiles

Manufacturing Quality Concrete Products

Material data sheet. EOS CobaltChrome MP1. Description

Common Defects in Digital Printing. Paul Geldenhuys & Amir Shapira January, 2009

Fire and Concrete Structures

Dryvit Finish System For Exterior Soffits

Materials for the production of primary aluminium

Specification Guidelines: Allan Block Modular Retaining Wall Systems

COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET

PRODUCT DATA SHEET DESCRIPTION:

VeMet, Utrecht, NL «Solution in Wear Protection» Dipl.-Ing. Wolfgang Leichnitz. Quit

PLEXIGLAS SUNACTIVE GS. For a Better Feeling

Dimensional Change Characteristics for Printed Circuit Board Films

Krystol Internal Membrane (KIM )

Quality Assurance Program. June by Texas Department of Transportation (512) all rights reserved

FINAL REPORT STRUCTURAL LOAD TESTING AND FLEXURE ANALYSIS OF THE ROUTE 701 BRIDGE IN LOUISA COUNTY, VIRGINIA

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

(T indicates a Tropicalised version with extended workability. No change has been made to the formulation)

2.1 DEFINITION OF INSULATION GENERIC TYPES AND FORMS OF INSULATION PROPERTIES OF INSULATION MAJOR INSULATION MATERIALS 4

FLEX-WRAP Foam Pipe Wrap

Transcription:

Price List 2.015 Rev.3 Sheet 1 of 5 Natural stone: PN001 Petrographic examination EN 12407:2007 185,00 PN002A Geometric characteristics EN 13373:2003 18,00 PN003 Water absorption at atmospheric pressure EN 13755:2008 97,00 PN004A Apparent density and open porosity EN 1936:2006 97,00 PN005A Real and apparent density and total and open porosity EN 1936:2006 245,00 PN006C Abrasion resistance: method A (Capon) EN 14157:2004 126,00 PN007A Frost resistance: Identification test until 14 cycles EN 12371:2010 165,00 PN007B Frost resistance: Identification test until 56 cycles EN 12371:2010 356,00 PN007C Frost resistance: Identification test until 84 cycles EN 12371:2010 468,00 PN007D Frost resistance: Identification test until 140 cycles EN 12371:2010 683,00 PN007E Frost resistance: Identification test until 168 cycles EN 12371:2010 776,00 PN008A Frost resistance: Technological test (lost of flexural strength under concentrated load after 12 cycles) EN 12371:2010 164,00 PN008B Frost resistance: Technological test (lost of flexural strength under concentrated load after 48/56 cycles) EN 12371:2010 353,00 PN008C Frost resistance: Technological test (lost of compressive strength after 12 cycles) EN 12371:2010 177,00 PN008D Frost resistance: Technological test (lost of compressive strength after 48/56 cycles) EN 12371:2010 403,00 PN008E Frost resistance: Technological test (lost of breaking load at a dowel hole after 12 cycles) EN 12371:2010 223,00 PN009A Compressive strength EN 1926:2006 135,00 PN009B Compressive strength EN 772-1:2011 135,00 PN010 Flexural strength under concentrated load EN 12372:2006 97,00 PN011 Flexural strength under constant moment EN 13161:2008 97,00 PN012A Breaking load at a dowel hole: Identification test EN 13364:2001 154,00 PN012B Breaking load at a dowel hole: Technological test EN 13364:2001 154,00 ( ) Tests accredited by

Price List 2.015 Rev.3 Sheet 2 of 5 PN012C Breaking load at a dowel hole (without cement) PE 17 Rev.7 126,00 PN012D Resistance to anchorage (grooved slabs) ETAG 034-1:2012 5.4.2.3.1 144,00 PN013 Resistance to salt crystallisation EN 12370:1999 265,00 PN014 Static elastic modulus EN 14580:2005 245,00 PN015 Knoop hardness EN 14205:2003 91,00 PN016 Rupture energy (by impact) EN 14158:2004 58,00 PN017A Water absorption coefficient by capillarity EN 1925:1999 97,00 PN017B Water absorption due to capillary action EN 772-11:2011 97,00 PN019C Resistance to ageing by thermal shock EN 14066:2013 257,00 PN019D Sensivity to changes in appearance produced by thermal cycles EN 16140:2011 120,00 PN020A Slip resistance by means of the pendulum tester (wet and dry conditions) EN 14231:2003 141,00 PN020E Slip/skid resistance value (wet conditions) ENV 12633:2003 97,00 PN020H Slip/skid resistance value (wet and dry conditions) ENV 12633:2003 141,00 PN020J Slip/skid resistance value (wet and dry conditions) CEN/TS 16165:2012 141,00 PN023 Surface roughness EN ISO 4288:1997 78,00 PN024 Chemical resistance EN ISO 10545-13:1997 240,00 PN035A Initial adhesion PE 31 Rev.1 183,00 PN035B Adhesion after 20 thermal shock cycles PE 31 Rev.1 265,00 PN035C Adhesion after 48/56 frost/thaw cycles PE 31 Rev.1 307,00 PN036 Wet tensile adhesion strength PE 31 Rev.1 183,00 PN050 Organic matter content 76,00 PN051A Thermal expansion coefficient PE 28 Rev.1 97,00 PN051B Thermal expansion coefficient EN 14581:2004 245,00 PN053 Resistance to ageing by salt mist EN 14147:2003 289,00 PN054 Sound speed propagation EN 14579:2004 86,00 ( ) Tests accredited by

Price List 2.015 Rev.3 Sheet 3 of 5 PN068 Mohs hardness EN 101:1991 35,00 Dimensioned stone (ASTM): PN025 Absorption and bulk specific gravity ASTM C97/C97M-09 97,00 PN026 Modulus of rupture ASTM C99/C99M-09 97,00 PN027 Compressive strength ASTM C170/C170M-14a 135,00 PN028 Flexural strength ASTM C880/C880M-09 97,00 PN029B Abrasion resistance ASTM C1353/C1353M-15 130,00 PN078B PN078C Resistance to rapid freezing and thawing (lost of flexural strength after 125 cycles, method B) ASTM C666/C666M-03 403,00 Resistance to rapid freezing and thawing (125 cycles, method A) ASTM C666/C666M-03 583,00 PN080 Petrographic examination ASTM C1721-09 185,00 PN082 Flexural modulus of elasticity ASTM C1352/C1352M-09 97,00 PN084 Strength of individual stone anchorages ASTM C1354/C1354M-09 154,00 Slates for roofing: PT039 Geometric characteristics EN 12326-2:2011 18,00 PT040 Flexural strength EN 12326-2:2011 205,00 PT041 Water absorption EN 12326-2:2011 97,00 PT042 Freeze-thaw EN 12326-2:2011 356,00 PT044 Sulphur dioxide exposure EN 12326-2:2011 168,00 PT045 Thermal cycle EN 12326-2:2011 123,00 PT046 Petrographic examination of thin sections EN 12326-2:2011 185,00 ( ) Tests accredited by

Price List 2.015 Rev.3 Sheet 4 of 5 Agglomerated stone: PA055 Apparent density and water absorption EN 14617-1:2013 90,00 PA056 Flexural strength EN 14617-2:2008 95,00 PA058 Freeze-thaw resistance EN 14617-5:2012 227,00 PA059 Thermal shock resistance EN 14617-6:2012 212,00 PA060 Impact resistance EN 14617-9:2005 58,00 PA061 Chemical resistance EN 14617-10:2012 136,00 PA062A Thermal expansion coefficient (20-80ºC) PE 28 Rev.1 97,00 PA062C Thermal expansion coefficient (30-130ºC) EN 14617-11:2006 118,00 PA063 Compressive strength EN 14617-15:2005 123,00 PA064 Resistance to fixing (dowel hole) EN 14617-8:2007 154,00 PA067A Slip/skid resistance value (wet conditions) ENV 12633:2003 97,00 PA067B Slip resistance by means of the pendulum tester (wet and dry conditions) EN 14231:2003 141,00 PA067E Slip/skid resistance value (wet and dry conditions) ENV 12633:2003 141,00 PA067F Slip/skid resistance value (wet and dry conditions) CEN/TS 16165:2012 141,00 PA069 Abrasion resistance EN 14617-4:2012 97,00 PA070 Electrical resistivity EN 14617-13:2013 99,00 PA071 Dimensional stability EN 14617-12:2012 68,00 PA072 Knoop hardness EN 14205:2003 91,00 PA073 Initial adhesion PE 31 Rev.1 183,00 PA074 Mohs hardness EN 101:1991 35,00 PA075 Dimensions, geometric characteristics and surface quality EN 14617-16:2006 180,00 PA076A PA076B Weathering by exposure to filtered xenon-arc radiation. Method 1: daylight, (200 h) EN ISO 11341:2004 160,00 Weathering by exposure to filtered xenon-arc radiation. Method 2, window ligth, (200 h) EN ISO 11341:2004 160,00 ( ) Tests accredited by

Price List 2.015 Rev.3 Sheet 5 of 5 PA107A Resistance to anchorage (grooved slabs) ETAG 034-1:2012 5.4.2.3.1 144,00 General conditions The CTM reserves the right to modify the prices without notice. Sending of samples will be paid by the customer. For tests which are requested by customers a detailed offer will be presented, and this proposal will contain prices and specific conditions, as well as the samples specifications. Acceptance of the offer should be sent in writing before beginning tests. If the customer has doubts about the terms of the offer, or this offer doesn t serve the customer exact needs, customers should contact the laboratory before testing begins. The CTM guarantees the confidentiality of received information and the results included in the report. All information to third parties must be previously authorised in writing by the petitioner. Clients who request tests, will have access to laboratory facilities to be present when tests, whenever this is possible. For each test carried out an independent report will be done, in Spanish + English or Spanish + French. Results in the reports will refer only to the samples and information provided by the customer. The CTM is not responsible for the representativily with respect to the marketed product. Specimens not destroyed will remain stored for 3 months from completion of tests, at the disposition of the customer which requested them. Complaints about test results should be made in writing, addressed to the test laboratory CTM. ( ) Tests accredited by