Eliminate Problems Created by Oil Carry- Over and Sludge:

Similar documents
Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Coalescing Oil Separators: Technology that improves performance and reduces energy costs of commercial refrigeration systems.

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

How To Design A Refrigeration System

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

How To Clean Water From An Ammonia Refrigeration System

Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

A/C refrigerant system, overview

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Atlas Copco Quality Air Solutions. Compressed Air Filters

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Maintenance Manual. Installation, Service and Adjustments. The more you know, the more you spec' Temprite.

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Basic Hydraulics and Pneumatics

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

COMPRESSOR REPLACEMENT PROCEDURE

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

DESIGN STANDARDS SECTION

COMPRESSOR REPLACEMENT PROCEDURE

- Service Bulletin - Pistons.

Automobile Air Conditioning Primer

Electric Motor Brake Horsepower Calculations

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Chapter 3: Separating Mixtures (pg )

Training Manual SUPER SEAL. Simplifying AC/R Repair. Inside Your Guide PROFESSIONAL FORMULA. Page

WASTEWATER TREATMENT OBJECTIVES

Planning for the ban on R22 in building air conditioning

Increasing Power Plant efficiency for safe wet stack Operation

Powerful protection for commercial heating and cooling systems

Flushing and Cleaning the A/C System

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Putting a chill on global warming

Filtering Samples to On-Line Process Analyzers. Guidelines for Proper Filtration and Delivery of Samples to On-Line Process Analyzers

Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c

Compressed Air Filters

Chemical incompatibility may cause dramatic filter plugging. This may happen when fuels with incompatible additive packages are mixed.

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

TRAINING, EXAMINATION AND CERTIFICATION

A Guide to Trouble-Free Cooling Towers

Natural gas liquids recovery from gas turbine fuel

Refrigeration Basics 101. By: Eric Nelson

Refrigeration System Installation & Operation Manual

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

Owner s Manual Phoenix 300

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Air Conditioning 101. STN Presentation AC101

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Water Wash Spray Booth Paint Sludge Recovery

In-Line Filters and Coalescers with Automatic Drains

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

SECOND GRADE 1 WEEK LESSON PLANS AND ACTIVITIES

REFRIGERATED COMPRESSED AIR DRYERS

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Why and How we Use Capacity Control

Accumulators and Receivers

(Walter Glogowski, Chaz Shapiro & Reid Sherman) INTRODUCTION

HCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22

Subject: 2005 Air Conditioning Service Guidelines

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Improving Diesel Engine Life:

In recent years, formicary corrosion has wreaked havoc on. Micro-channel

Mechanical Seal Piping Plans

Chilled Water HVAC Systems

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Compressors Buying Guide

Solar Hot Water. What systems are available?

Nirvana. Cycling Refrigerated Dryers

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Refrigeration and Air Conditioning Mechanic On-the-Job Training Guide

Steam Jet Vacuum Pumps

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

How Ground/Water Source Heat Pumps Work

How To Understand Evaporator

Owner s Manual Phoenix 200 MAX

RS-24 (R426A): Q & A

BY MCI SOLUTIONS SECONDARY CONTAINMENT ADAPTOR

CONDENSATE MANAGEMENT

SEALED SYSTEM DIAGNOSIS

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

Characteristics of Evaporators

Transcription:

Eliminate Problems Created by Oil Carry- Over and Sludge: Build-up of lubricating oil (carry over) in refrigeration and air-conditioning systems is, perhaps, the oldest unresolved problem vexing the industry This statement was published in the ASHRAE Journal as recently as April 1995. Oil related problems cost the industry millions in terms of service calls, energy costs and compressor burnouts. Evidence a statement by compressor rebuilders Fridgemotors Ltd. published in AC&R News loss of lubrication is the largest single effect of compressor failure. It may be significant that no less than 49 companies are listed under compressor rebuild/remanufacture in the RAC Yearbook. Oil Carry Over How much of a Problem? The scale of oil carry-over is probably much greater than is generally realized. In a previous issue of Service Engineer, Glen Moore highlighted that this is a serious problem even on new systems. Compressor seizures occur, due to lack of oil. In such cases the problem my be due to a number of causes: The system may not have been fitted with an oil separator. The oil separator fitted may have been wrongly sized for the system duty or just inefficient. The use of large diameter ring mains reduces the velocity of the gas/oil mixture (mass flow) preventing the oil from returning to the compressor. If oil carried over to the system is not replaced, the compressor will seize. The causes of oil failure are many and varied. It pays to concentrate on eliminating oil carry over up front, rather than spend time and money to rectify the problem. Prevention is better than the cure. What about Scrolls? It is generally accepted that the carry-over rate on Scrolls is much less than on reciprocating compressors. However, Copeland warns that oil leaves the compressor at start-up, regardless of the low oil carry over of the scroll. The problem increases with multi-compressor systems subject to variable load conditions where compressors may be downloading on a regular basis. Copeland application guidelines highlight the potential for oil carry-over by recommending that the number of start-stop cycles be limited to 10 per minute. According to Copeland, a high cycling rate, will pump oil into the system and may lead to lubrication failure. So, oil carry-over is a problem even on new systems and Scroll compressors. The Effects of Oil Carry-Over.

Clean Oil in a system insulates the evaporator and the condenser, thus reducing efficiency. This makes the compressor work harder which increases energy and maintenance costs and, subsequently reduces the lifecycle of the compressor. Too much oil in the pipework will return down the suction line and result in compressor failure. Installations with electric defrost systems are particularly at risk. Oil in the system cannot remain clean long, especially the new POE oils with their powerful solvent effect. Oil in the system quickly combines with moisture, acids, metal particles and other contaminants to produce sludge. This destroys the lubricating properties of the oil and results in compressor burnout. A major effect of dirty oil circulating in the system is that it quickly clogs up the pores of filter-driers and greatly reduces their capacity to do the job for which they were intended to remove moisture and acids. Eventually, this results in plating of the crankshaft journals which will guarantee a compressor failure. Understanding Oil Separation. The process of oil separation is effected in two states. The oil/gas mixture leaving the compressor and entering the larger diameter oil separator body is allowed to expand. Its velocity is greatly reduced. All of those atomized oil droplets in the mass flow that are madly putting on the brakes collide into one another begin forming larger and larger droplets. These larger droplets then fall to the bottom of the oil separator through gravity. This process would take place in an empty can. The larger diameter the better. Smaller droplets in aerosol form require some sort of mechanical agitation to cause them to collide, grow larger and heavier before falling to the bottom of the separator. Refrigerant oils in aerosol form range from less than 0.1 to 40 microns in size. The majority of aerosols in the discharge gas are in the 0.4 to 10 micron range with more than 50% of the aerosols less than 1 m (micron) in size. Oil in aerosol form is particularly difficult to remove. If this oil is not converted to droplets big and heavy enough to drop out through gravitational pull, it will be re-entrained. If velocity is too low, there will be insufficient forces to cause the smaller droplets to collide and drop to the sump. The chart below shows the typical aerosol distribution exiting the compressor. About Oil Separators. Oil separators as we know them have been around for over 50 years. Efficiency of most separators on the market was pretty much the same. That is to say, around 60% to 80%. These were fine when systems were less complex. However, with the introduction of multi-compressor and dual temp systems, long pipe runs, electric defrost and floating head pressures, subsequent oil carry-over problems multiplied. Conventional Oil Separators.

Conventional oil separators and these include impingement screen, centrifugal, cyclonic, helical, etc., are dependant on velocity for their performance. It s what makes them work. If velocity drops off, efficiency goes with it. The performance of conventional oil separators is unpredictable on systems subject to variable load conditions where separation efficiency fluctuates with the velocity. Go below 50% load and the separation efficiency becomes unreliable. Coalescent Oil Filter Separators. The process of separation by coalescing filter is employed in the petrochemical and industrial gasses industries, where product purity must be maintained. The diagram shown below shows how the process works. Separators designed around the coalescing filter principal have the ability to remove 99.997% of the oil droplets greater than 0.3, removing virtually all of the oil from the mass flow. Because it s totally nonvelocity dependant the separation efficiency is guaranteed across the systems full range of operating conditions. It remains 98% or more efficient even at 10% of the systems rated capacity. The graph below compares the efficiency of different oil separators. Oil Filtration at 0.3 microns Every system should have a filter of at least 10 microns. One major compressor manufacturer voids their warranty if this condition is not met. The coalescing filter element is designed to remove all solid contaminants to 0.3 m. In contrast, a suction line filter can only pull out 30 to 50 microns. This adds a higher level of protection to all components in the system. This especially true for compressors and metering devices. This level of filtration exceeds that of any other component ever built into a commercial system. This filtration is a by-product of the coalescent separator s efficiency, effectively killing two birds with one stone. Coalescing Filters. The photograph below shows a typical filter element in as new condition. In a correctly designed system, the pressure drop ( p) across the filter element will be negligible. Remember, the separator filter element is 90% void material. It s made of exceptionally pure borosilicate glass fibers frozen in place by a binder specially designed for refrigeration applications. Even when the filter element is 50% plugged with contaminants, there s only a minimal 5 pound p.

Retrofitting Temprite 920 Series Coalescent Oil Separators to an Existing System. Fitting a coalescing filter separator is recommended as part of any regular maintenance programme. During a refurbishment programme in a US supermarket, a coalescing oil separator was retro-fitted to an existing system. This particular system had been plagued with poor performance due to excess oil carryover and sludge. Within the first 48 hours, service techs pulled over 100 litres of oil out of the system. Compressor run time was reduced from 19 to 13 hours per day. And after a total of three filter changes, the oil was restored to its original color. The photograph below shows a coalescent oil filter after being removed from a retro-fit that had had a compressor burn-out. A coalescent separator will clean up even the dirtiest system, even after a burn out. It may take more than one filter change, but compared with alternative methods, it will achieve the best results with the lowest

cost and the least mess. Moreover, the original system efficiency will be improved, running and service costs will be reduced and the life cycle of the compressors greatly extended. On New Systems Coalescing oil separators eliminate many problems associated with oil carry-over in new systems. Because separation efficiency is so high, the need to continually check oil levels and top-up reservoirs after commissioning is greatly reduced. Filtering out all solid contaminants to 0.3 m keeps the drier cores clean for moister and acid removal. Oil logging in low-lying pipework and large diameter ring mains ceases to be a problem. Less time is necessary in designing pipe layouts and where to fit oil traps. Systems subject to variable load conditions, long pipe runs, floating head pressures and electrical defrost, etc., are protected from oil return down suction lines, which can be potentially fatal to compressor operation. Best Thing We Ever Did. The following comments come from a major UK pack builder who incorporated coalescing separators into his system over three years ago: Radford adopted the Temprite [920 Series] coalescing oil separation system in conjunction with our own (Radford s) High Pressure Oil Management Control some three years ago. During this period we have manufactured compressor sets using approximately 3500 compressors. For this same period compressor losses [have] been in the order of less than one percent. Some of the earlier sites have undergone cabinet refits. Engineers have reported oil-free liquid and suction lines even in low level pipe work. Temprite [920 Series] coalescing oil separators are also installed at our testing laboratories in Chew Stoke. Once again, we have encountered oil-free refrigerant pipelines when the cabinets have been uninstalled after testing. We have not encountered any service issues or operating problems. Best thing we ever did. -- Mark Lawson at Radford Retail Systems