Application Note: Absorbance



Similar documents
Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Measuring Protein Concentration through Absorption Spectrophotometry

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Lab #11: Determination of a Chemical Equilibrium Constant

Using the Spectrophotometer

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Experiment #5: Qualitative Absorption Spectroscopy

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

2 Spectrophotometry and the Analysis of Riboflavin

where h = J s

How to measure Chlorophyll-a

Upon completion of this lab, the student will be able to:

Colorimetric Determination of Iron in Vitamin Tablets

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

MCAL Spectrophotometry. Spectrophotometry

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:

An Introduction to Algae Measurements Using In Vivo Fluorescence

Chem 131A: Absorbance of Riboflavin

2 Absorbing Solar Energy

Electromagnetic Radiation (EMR) and Remote Sensing

A Beer s Law Experiment

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

INTERNATIONAL OLIVE COUNCIL

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

CHEM 161: Beer s Law and Analysis of a Sports Drink

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

Reaction of Blue Food Dye with Bleach

Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

Beer's Law: Colorimetry of Copper(II) Solutions

The Determination of an Equilibrium Constant

Copyright by Mark Brandt, Ph.D. 12

INTRODUCTION TO SPECTROMETRY

Experiment C-31 Color Absorption

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Infrared Spectroscopy: Theory

Molecular Spectroscopy

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

Solubility Product Constants

Studying Photosynthetic Electron Transport through the Hill Reaction

Lab 2. Spectrophotometric Measurement of Glucose

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

Phenolphthalein-NaOH Kinetics

Symmetric Stretch: allows molecule to move through space

Determination of the Mass Percentage of Copper in a Penny. Introduction

Measuring Manganese Concentration Using Spectrophotometry

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Name Class Date. spectrum. White is not a color, but is a combination of all colors. Black is not a color; it is the absence of all light.

Stage 1 Desired Results

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

UV-Visible Spectroscopy


Ultraviolet Spectroscopy

- particle with kinetic energy E strikes a barrier with height U 0 > E and width L. - classically the particle cannot overcome the barrier

How do scientists prepare solutions with specific concentrations of solutes?

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

5.33 Lecture Notes: Introduction to Spectroscopy

Where does it come from?

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

Biology 309 Lab Notebook

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

Introduction to Fourier Transform Infrared Spectrometry

Project 2B Building a Solar Cell (2): Solar Cell Performance

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

Introduction: Growth analysis and crop dry matter accumulation

BET Surface Area Analysis of Nanoparticles

Quantifying Bacterial Concentration using a Calibrated Growth Curve

Biomedical Optics Theory

Light Backscatter Applications in Milk and Dairy Foods Processing

EDXRF of Used Automotive Catalytic Converters

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

OPTICAL FIBERS INTRODUCTION

The photoionization detector (PID) utilizes ultraviolet

4.2 Bias, Standards and Standardization

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Supporting Information. Rational design of Au nanorods assemblies for highly sensitive and selective SERS detection of prostate specific antigen

AP Physics 1 and 2 Lab Investigations

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Application Note Noise Frequently Asked Questions

NNIN Nanotechnology Education

Coordination Compounds with Copper (II) Prelab (Week 2)

Transcription:

Units Units Theory of absorbance Light absorption occurs when atoms or molecules take up the energy of a photon of light, thereby reducing the transmission of light as it is passed through a sample. Light attenuates exponentially as it passes through clear materials or solutions. So, naturally the reduction of transmitted light is exponentially related to the concentration of the sample and path length of light traveled (Figure 1A). %T = [(Transmitted Light) / (Incident Light)] * 1 3.5 3.5 3 1A 3 1B 2.5 2.5 2 1.5 1.5 2 4 6 8 1 % Transmittance 2 1.5 1.5.5 1 1.5 2 2.5 3 3.5 2 - Log 1 (%T) Fig. 1A) % Light transmitted per Unit, 1B) relationship between absorbance and %T Beer-Lambert Law Beer-Lambert Law relates the transmittance of light to absorbance by taking the negative logarithmic function, base 1, of the transmittance observed by a sample, which results in a linear relationship to the intensity of the absorbing species and the distance traveled by light. = 2 - Log 1 (T) In short, Beer-Lambert Law states that the absorbance of a sample is directly proportional to the path length of the sample holder and the concentration of the sample. Incident Light 1 cm Light Path Transmitted light = 2 Log 1 (T) LED Filter Sample Detector Light Cuvette Source Figure 2. Absorption measurement scheme S-75 Revision A Page 1 of 5

Units Range and detection limits is measured in absorbance units (Au), which relate to transmittance as seen in figure 1. For example, 1.Au is equal to 1% transmittance, 2.Au is equal to 1% transmittance, and so on in a logarithmic trend. Because transmittance inherently decreases logarithmically, linearity breaks down at higher concentrations due to sample saturation (Figure 3). Since the transmitted light at 2.Au is less than 1%, any increases in concentration will reflect only slight changes in absorbance. Generally, you will never reach an absorbance of 4.Au and still maintain a linear relationship. The same applies for lower end limits. Samples being measured for absorption, which are primarily clear solutions or close to zero, are subject to the errors associated with light refraction, reflection, or scattering. For example, scattering can decrease the transmission of light through a sample and will effect the absorbance even though no absorption is occurring. These kinds of errors can be reduced in turn maximizing resolution through particle removal, which minimizes scattering of light and using glass cuvettes, which minimizes absorption of light. Applications micromolar Concentration Figure 3. Theoretical response curve of absorbances at increasing concentrations measurements can be used to measure the concentrations in different ways such as using absorption coefficients with pigment calculations or calibration curves as with nutrient analyses. For either method used the basic principal is to create a correlation factor between absorbance and concentration to be used for determination of absorbing species in natural samples. S-75 Revision A Page 2 of 5

Pigments Pigment concentrations are calculated by taking the absorbance reading of the largest peak in a pure pigment spectrum, as characterized by a spectrophotometer, and dividing that absorbance value by the pigments specific absorption or molar absorption coefficients. Units (Au) Concentration of Pigment (mg/l) = * 1 Specific Absorption Coefficient (L g -1 cm -1 ) Pigment Algal Group Represented Specific Absorption Coefficient (L g -1 cm -1 ) Units (Au) Calculated Concentrations (mg/l) Chlorophyll a All Algae 87.67.2519 ( = 664nm) 2.87 Fucoxanthin Diatoms 166.1675 ( = 443nm) 1.9 Chlorophyll b Green Algae 51.36.3549 ( = 646nm) 6.91 Table 1: Example of spectrophotometric determination of pure pigment concentrations using specific absorption coefficients (Jeffrey et al 1997) for Chlorophyll a, b, and Fucoxanthin. The derivations of these coefficients require extremely careful and highly analytical techniques but the end calculation is very simple. To obtain a specific absorption coefficient of a pigment, one would need to purify the pigment from all contaminants and either dry or crystallize the molecule. After purification, the resulting material needs to be dissolved in solvent and measured for absorbance. Keep in mind that absorbance measurements are solvent specific as well. The specific absorption coefficient obtained from a spectrum of the pigment would serve as the universal standard for quantifying this specific pigment s concentration from any spectrophotometric measurement. Specific absorption coefficients of pigments are usually given in volume per weight with respect to path length of the cuvette used (i.e. liter gram -1 centimeter -1 ). Nutrients Nutrient concentrations are simpler calculations and less tedious. The simplicity of nutrient calculations comes from a basic understanding of algebraic expressions. A calibration curve is produced, which relates the absorbance to concentration of absorbing species. S-75 Revision A Page 3 of 5

Concentration (um) Concentration (um) 6 1uM - 5uM y = 45.965x - 13.353 R 2 =.9856 8 3uM - 7uM y = 63.894x - 33.375 R 2 =.9876 5 4 3 7 6 5 4 Regression equation. R 2 value showing good linear relationship 2 1 3 2 1.2.4.6.8 1 1.2 1.4 1.6 1.8 2.2.4.6.8 1 1.2 1.4 1.6 1.8 2 Units (Au) Units (Au) Figure 4: Example of established linear correlation between concentration of absorbing species and absorbance readings (Au) for 2 different working ranges. The equation of the regression can be used to calculate the concentrations of unknown samples by simply plugging in X values that fall within your working range. The equation of the curve is used to calculate natural sample concentrations as long as they fit within the range of the curve (Fig. 4). Accurate concentration values can be achieved from absorbance measurements if a couple of important points are kept in mind: 1) Choosing a range of absorbance units and establishing a linear calibration curve for that range 2) If measuring samples outside the range your calibration curve, making sure your samples are diluted to fit the range calibrated 3) Following procedure for correct preparation of reagents 4) Avoid cross contamination among samples 5) Keeping the optical path constant (i.e. don t change cuvettes sizes while analyzing samples) 6) Blank correcting by running a reagent blank 7) Minimizing transmission loss, due to particle scattering, by centrifugation or other means of particle removal 8) Minimizing transmission loss by using sample holders that will not absorb of light 9) Plugging x, the absorbance value from an instrument, into the regression equation, Y = mx+b will provide you with an accurate estimate of your absorbing species if you have established a good linear relationship as determined by the R 2 value or your regression (Note: Accuracy of estimates increase as your R 2 value increases) S-75 Revision A Page 4 of 5

References: S. W. Jeffrey, Mantoura R. F. C. and Wright S. W., 1997. Phytoplankton pigments in oceanography. UNESCO Publishing France, Paris J. D. H. Strickland and T. R. Parsons, 1972. A practical handbook of seawater analysis. Second Edition, Bulletin 167. Fisheries Research Board of Canada, Ottawa Timothy R. Parsons, Maita Y. and Lalli C. M., 1984. A manual of chemical and biological methods for seawater analysis. First Edition. Pergamon Press Ltd., Great Britain Brian M. Tissue, 1996. On-line Educational Hypermedia (www.scimedia.com hypermedia for science education). Science Media Ltd. Irvine, Ca. S-75 Revision A Page 5 of 5