GENREADY LOAD CENTER AND TRANSFER SWITCH

Similar documents
Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Contractors Guide Central Inverter System Installation

Eaton Automatic Transfer Switches

SPEEDFAX TM 2011 Load Centers & Circuit Breakers Contents

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Transfer switch BTPC open, closed or delayed transition

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Distribution Dry Type Transformers

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

For 100 Amp Automatic Transfer Switch/Load Center Models: 10 Circuit, 12 Circuit and 16 Circuit. Installed with 7, 10, 13 and 16kW Generators.

Continuous Power... Continuous Protection

Magnum Mobile Generator MMG55 Specifications

Introduction. Upon completion of Basics of Load Centers you should be able to: Explain the role of a load center in residential power distribution

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

Requirements for Electrical Installations

residential & commercial Generators

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Remote Power Panels with Breakers

Diesel Engine Driven Generators Page 1 of 6

ELECTRICAL INSPECTION BULLETIN (Effective )

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Mini Power-Zone Unit Substation

Electrical Service Guidelines

Generator DoCKInG StatIonS

Owner's/Installation Manual

PowerPlus. Integrated Power Distribution Cabinets. Most effective space-saving. integrated system on the market. Engineered to be shipped as a

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

MCC Ratings. Voltage Rating

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Secondary Unit Substations

IRRIGATION PUMPING Table of Contents - Section 900

Lightning Arresters P KVA P KVA. Description & Installation

ASCO SERIES 185 Power Transfer Switches

GTEC transfer switch open transition

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Iso-Gard Series 6 Line Isolation Monitors

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Mazda CX

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

INTRODUCTION INTERLOCK KIT K-8110

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Limited Service Fire Pump Controllers Features

LIEBERT VNSA Installation Sheet

Mazda CX up B

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

SENTRON Switching and Protection Devices Air Circuit Breakers

Frequently Asked Questions Generators

Electrical Grounding. Appendix C

For Models #6-5001, #6-7501, # & #10-12K1

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Commercial Gas Furnace Upflow

GHN424NW HHN426N HUN361AW

RAY-MAX Integrated Solar Power Strip

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

FW-X240 AUTO TRANSFORMER Installation Manual

Redesign of kW Diesel Products Reflects Voice-of-The-Customer Improvements

The complete range of consumer switchboards and switchgear

Temporary Power Outlet Panels. Selection and Application Guide.

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Video Camera Installation Guide

Temporary Power Outlet Panels

Owner's Manual. Automatic Transfer Switch. This manual should remain with the unit.

UNDERGROUND ELECTRIC TEMPORARY SERVICE PANEL

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Cable/Conduit Conversion

8146/5 Series Breaker Panelboards

How To Test A Power Switch On A Power Supply

DIESEL GENERATOR SETS

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

BASIC NEC CODE RULES AND DESIGN PRACTICE

TC Grounding and Bonding for Telecommunications Systems

Circuit Breakers. Next Generation of Protection Capabilities

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Air-cooled Generator Battery Charger Installation Guidelines

SPEEDFAX TM 2011 Disconnect Switches Contents

Transcription:

GENREADY LOAD CENTER AND TRANSFER SWITCH DESCRIPTION The GenReady load center is a hybrid panel that operates as a normal load center and also allows for seamless integration of standby generators. GENREADY LOAD CENTER FEATURES 40 circuit capacity with the use of tandem breakers Dimensions are the same as a standard 42-space main load center Utilizes standard Siemens components Protect up to 18 circuits, up to 30 with the use of tandem breakers 10 circuits available for non-protected loads Circuits can easily be shifted from protected to non-protected and vice versa UL listed and service entrance rated Models available with or without EZ Transfer operator factory installed Single panels are compatible with generators rated up to 125 Amps/30 kw Multiple GenReady load centers can be supported with a single generator Flush Mount NEMA 1 Enclosure EZ TRANSFER OPERATOR FEATURES Factory installed on the GenReady Advanced model. Can be easily installed in the field on the GenReady Basic with available kit Allows for manual or automatic operation Please Note: The GenReady Panel is designed to be directly compatible with any Generac manufactured product. Use of another manufacturer s generator may require the purchase and installation of additional sensing and control components.

PRODUCT OPTIONS GenReady Basic Load Center Model Number 5448 GenReady Advanced Load Center with EZ Transfer Operator Model Number 5449 EZ Transfer Operator Field Installation Kit Model Number 5447 Transfer Operator Field Installation Kit Transfer Operator 15A Double Pole Breaker for Generator Sensing Circuit Includes GenReady Basic plus: 125A Circuit Breaker EZ Transfer Operator 125A Lower Panel Circuit Switch 200A Main Circuit Breaker 15A Double Pole Breaker for Sensing Circuit Plus all other components found in the field installation kit. Hold Down Bracket Interlock Bar Mounting Hardware Decals Installation Guide INSTALLATION OPTIONS GenReady Basic GenReady Advanced GenReady Complete without the EZ Transfer operator. It replaces the home s main load center. This option will save the homeowner thousands in upgrade costs when a generator is installed. with the EZ Transfer operator. All fuel and electrical lines (contractor supplied) are installed to the planned generator site along with the generator pad (if required). The home is completely wired and ready for the addition of a generator in the future. Everything included in the GenReady Advanced level is installed along with an automatic standby generator. The home s selected circuits will be backed up by generator power whenever the utility is lost.

PRODUCT OPTIONS GenReady Basic Load Center Model Number 5448 GenReady Advanced Load Center with EZ Transfer Operator Model Number 5449 EZ Transfer Operator Field Installation Kit Model Number 5447 Transfer Operator Field Installation Kit Transfer Operator 15A Double Pole Breaker for Generator Sensing Circuit Includes GenReady Basic plus: 125A Circuit Breaker EZ Transfer Operator 125A Lower Panel Circuit Switch 200A Main Circuit Breaker 15A Double Pole Breaker for Sensing Circuit Plus all other components found in the field installation kit. Hold Down Bracket Interlock Bar Mounting Hardware Decals Installation Guide INSTALLATION OPTIONS GenReady Basic GenReady Advanced GenReady Complete without the EZ Transfer operator. It replaces the home s main load center. This option will save the homeowner thousands in upgrade costs when a generator is installed. with the EZ Transfer operator. All fuel and electrical lines (contractor supplied) are installed to the planned generator site along with the generator pad (if required). The home is completely wired and ready for the addition of a generator in the future. Everything included in the GenReady Advanced level is installed along with an automatic standby generator. The home s selected circuits will be backed up by generator power whenever the utility is lost.

PRODUCT OPTIONS GenReady Basic Load Center Model Number 5448 GenReady Advanced Load Center with EZ Transfer Operator Model Number 5449 EZ Transfer Operator Field Installation Kit Model Number 5447 Transfer Operator Field Installation Kit Transfer Operator 15A Double Pole Breaker for Generator Sensing Circuit Includes GenReady Basic plus: 125A Circuit Breaker EZ Transfer Operator 125A Lower Panel Circuit Switch 200A Main Circuit Breaker 15A Double Pole Breaker for Sensing Circuit Plus all other components found in the field installation kit. Hold Down Bracket Interlock Bar Mounting Hardware Decals Installation Guide INSTALLATION OPTIONS GenReady Basic GenReady Advanced GenReady Complete without the EZ Transfer operator. It replaces the home s main load center. This option will save the homeowner thousands in upgrade costs when a generator is installed. with the EZ Transfer operator. All fuel and electrical lines (contractor supplied) are installed to the planned generator site along with the generator pad (if required). The home is completely wired and ready for the addition of a generator in the future. Everything included in the GenReady Advanced level is installed along with an automatic standby generator. The home s selected circuits will be backed up by generator power whenever the utility is lost.

UNIT DIMENSIONS 14.38 15.63 4 Outside Dimensions of Enclosure Shell Front Cover & Door 42 43.25 Equipment Ground Utility Generator Transfer Operator Bonding Connection Neutral

SPECIFICATIONS Enclosure...NEMA Type 1, general purpose, painted metal Main Breaker... 200 Amp Generator Switch... 125 Amp Main breaker wire size... # 1 to 300 mcm Cu-Al Generator switch wire size...# 2 to 1/0 Cu, 1/0-2/0 Al Neutral Lug... # 6 to 300 mcm Ground Lug... # 14-2/0 Ground Fault or Arc Fault Circuit Breaker... QPF or QAF Siemens Maximum number of circuits (standard 1" breakers / tandem 1/2" breakers) Protected circuits...18/30 Non-protected circuits...10/na Total circuits...28/40 Withstand rating Main bus (amps)...22,000 Meets NEC wire bending space...yes UL listed...yes Seismically qualified to meet UBC code...yes Weight GenReady Basic w/o EZ transfer operator (GenReady Advanced with EZ transfer operator)...45.5 lbs. (49 lbs.) Operating temperature range...-20º F to 140º F GENERAC POWER SYSTEMS, INC. P.O. BOX 8 WAUKESHA, WI 53187 262/544-4811 FA X 262/544-4851 Bulletin 0175200SBY / Printed in USA 03.08 2008 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.