SOLAR POWER MICRO-INVERTER

Similar documents
YSmart Technology Co.,Ltd

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

User s Manual Before using the inverter, you need to read and save the safety instructions.

WVC300 Micro-inverter solar grid system (Power line communications)

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

Photovoltaic Solar Energy Unit EESFB

TruPower-Portable-500W. Solar Starter kit

BB800 Off-Grid Solar System

ST Series POWER SUPPLIES USER INSTRUCTIONS

ABB central inverters PVS to 1000 kw

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Product catalogue. solar charge controller & inverter BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: Fax:

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Owner s Manual channel amplifier

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

How To Control A Battery Cell Phone With A Battery Power Control System

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Actuator-Sensor-Interface

46120-F0 Solar Energy Training System

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Battery Power Inverters

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

INVERTER SYSTEM PRODUCT BROCHURE

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Online UPS. PowerWalker VFI 1000R/1U

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

ADM1TE 5/30A DIN rail single phase two wire energy meter

ACS-30-EU-EMDR-10-MOD

ATLAS DC. Model: CSFDC B1 CSFDC B1/CSFDC B2 CSFDC B1/CSFDC B2

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Power Electronics Testings

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

THE INPUT/OUTPUT SYSTEM. Key Points

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Manual. Solar Fountain Mobile Phone Charger

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

12 Volt 30 Amp Digital Solar Charge Controller

Installation and Operation Back-UPS 1250, 1300, 1500

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SNMP Web Management. User s Manual For SNMP Web Card/Box

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

User Manual for CH-PFC76810

T Substation Maintenance and Commissioning Test Equipment

Three-phase monitoring relay CM-PFE

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

AutoRanging Digital MultiMeter

Everything you need for protection scheme testing

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Power Supplies 3. SDN-P DIN Rail Series

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

BITMAIN. APW PSU Series User Guide

MAJORSINE Power Inverter

DC DC CONVERTER 1000W VDC Input / 12VDC Output

Connecting your Victron product to a computer with VE Configure

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Hybrid Power System with A Two-Input Power Converter

AJ s Technical Tips: Designing a Small Solar PV System Part IV; Selecting Wires for the System

Wind/solar hybrid controller instructions

ECEN 1400, Introduction to Analog and Digital Electronics

The Basics of Solar Power for Producing Electricity An excellent place to start for those just beginning. The basics of solar power: 1000 W/m²

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

User Manual 1K/2K/3K Online UPS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

PERF10 Rubidium Atomic Clock

DC Electronic Loads 8500 series

RM4TG20 three-phase network control relay RM4-T - range V

Fronius IG Plus. The next generation grid-connected PV inverter

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Transcription:

2011 Beijing Multift Electrical Technology Co., Ltd. Tel:86-10-87227420 Fax:86-10-87227420 Website:http://www.multifitele.com Address:Room812,Block B.3# Rongjingdong Street,Beijing Economic&Technological development Zone 100176 Beijing, China.

260W PV micro inverter User Manual System function Power line carrier-current communication(used in WVC series) By using electric power as a carrier of AC alternating current, can modulate high-frequency and carrier frequency (60KHz) in AC wire transmission and can achieve the communication/ newsletter between inverters or between inverter and computer. And it can transfer the power data and the brightness date of the sunshine in the real-time. Also monitor all functions of inverter. 1. Carrier frequency:60khz(frequency customizable) 2. Interface way:ttl level serial interface 3. Carrier rate:300bps 4. Serial rate:9600bps(can customize according to customer's request) 5. Modulation mode:fsk+dsss 6. Newsletter distance:2km 6-grade power search In overcast weather, the solar battery s output current is extremely tiny, then inverter will automatic open 6-grade power search function. 1. The program can automatically open power adjustment for 6 times. 2. The current direction can adjust from the maximum to the minimum. 3. In automatic adjustment process, we will see the LOW light flashing. And the power will keep as a starting point, from 0 to the maximum output power, and it will restart at most for 6 times, then locked in the maximum power, the ST lamp long bright. 4. It need 10 minutes for 6-grade power search. Wide voltage input(22-60vdc) Achieve wide voltage input. 1. DC voltage input:22-60vdc 2. Second level power variable voltage conversion High-frequency two-way and one-way grid function 1. High frequency direct modulation, AC half wave synthesis 2. Two-way grid means: Load consume directly. And can reverse AC current transmission. Kinds of frequency output function. 1. It can apply to 50Hz and 60Hz frequency of AC. 2. Frequency range: 48Hz ~ 63Hz directly connected to the solar panels (do not need to connect the battery) Using precise Dynamic differential pressure type MPPT function, APL functions, the inverter automatically adjust the solar panels of maximum output power,simply connect the solar panel to the grid inverters. Do not need to connect the battery. 1. Differential pressure type MPPT: 0.1 V accuracy 2. Power lock: 10W (AC output) AC 0 angle with high precision auto-detection AC phase angle of 0 through isolation amplifier then input to the MCU for high-precision detection and analysis. The phase shift rate is less than 1%, thus achieve high-precision with phase modulation AC output together. 1. AC phase shift: < 1% 2. Over-zero protection: 0.2 VAC 3. AC switching: 50Hz / 60Hz Synchronous High-frequency Modulation In the process of the grid, usually adapt the same phase angle in parallel. (ie, When the two-phase alternating current total is equal to 0.Use switch to combination the two AC fusion) and the product is rectified AC half-frequency AC to 100Hz first, then the machine use the high frequency current in the circuit and semi-100hz frequency alternating current generated combination, to achieve high-frequency modulation. 1. Modulation synthesis: half wave and full-bridge modulation synthesis (100Hz / 120Hz) 2. Synthetic way: MOSFET full-bridge 3. High frequency: 50KHz Pure Sine Wave Output Use SPWM directly to make pure sine wave output. 1. Output waveform: Adopt complementary PWM to push-pull pure sine wave. 2. Generate means: enhancement-mode SPWM Automatic Sensing Function Solar Luminosity Use the latest luminosity perception operation technology. The different illuminate angle and intensity of the solar panel will produce different current output. Use advanced CPU to operate the different intensity of illumination and the data can be directly displayed on the LCD. Then you can visually see the sense of the strength of the sun unit. Used more convenient. 1. Luminosity sampling point :power sampling point 2. High precision AD sampling: integral AD sampling method Power Automatically Locked (APL) In different current fluctuations, we should use the MPPT function. When the MPPT function adjusted to the maximum power point, the product automatically powers locked in maximum power point, then made the output power more stable. 1. Power lock: The biggest sampling point of MPPT. Automatically Adapt To Different Load Power Factor Adapt to any of the power load. Constant Current, Constant Power This product is constant current, constant output power, without any overload, over-current phenomenon. Automatically Shut Down When The Power Grid Fault When the city power system is in failure, the inverter will automatically turn off the output. 1. Current Limit Protection 2. Current limit Stack Multiple Machines Multiple small power inverters in parallel can achieve large output power. High-Frequency High Conversion Rate Adapt high frequency converter, the output more efficient. Maximum Power Point Tracking (MPPT) Because the current intensity and the voltage changes at any time, if there is no power point tracking, there will be a lot of problems. In the past time, usually adopt a solar controller, but this product uses high-precision (MPPT) operation power, automatic and immediate adjust the solar panels output power at the maximum output point, then achieve a stable output purposes. 第 2 页

MPPT is for short of "Maximum Power Point Tracking". It means the controller can sense the voltage of the solar panels on time, and can track the highest voltage and current (VI).Then made the inverter discharge to power grid with the highest efficiency. The peak voltage (Vpp) of the solar panels is about 38V when it in factory. And the environment temperature is 25 C. The reason of setting this temperature(interestingly, different from the subjective imagination, we ordinary people the conclusion may let us surprised) is that when the weather is very hot, solar panels peak voltage will fall to about 36 V while in cold weather, the peak voltage can achieve 43 V. Now we back to contrast the difference of MPPT solar energy grid inverter and traditional inverter. The traditional solar inverter is a bit like the manual gearbox. When the engine speed increase, while the gearbox gear don't increase at the same time, it will definitely affect the speed of the car. For traditional inverter speaking, the parameter output power is been set in factory. It likes a car have been fixed set on fixed 1 gears, no matter how powerfully you trample accelerator, the speed of a car is limited. While have the MPPT function it will be different, it is automatically. It will automatically adjust the gears according to the engine speed, so it can make cars in the most gears in a reasonable efficiency standard operation. It means the MPPT controller can track the maximum power point of solar panels in real-time then express the biggest efficiency of solar panels. The higher the voltage, the more power can be output through the MPPT. Thus improve the charging efficiency. Theoretically speaking, using MPPT, the efficiency can be increased by 50% compared with the traditional inverter. But due to environmental impact and various around energy loss, the ultimate efficiency can improve 20%-30% according to our actual testing. Stack using In order to achieve higher power use requirements, this product can be stacked. Such as: 4 micro inverter of 260W stacking can achieve 1040W. And the number of the stacking is unlimited. DC input Input voltage range: 22V to 60V Solar Panel: Recommend using the power more than 30W and the standard voltage of 36V PV panels. Recommend using multiple solar panels. Solar panel in series will result in high-input voltage which will exceed the working voltage range of the inverter. AC output Voltage range of the inverter whose output is 220V AC.: 190V - 260V, 50HZ Voltage range of the inverter whose output is 110V AC.: 90V - 160V, 60HZ Parameter table models 260W-230V/50Hz/120V/60Hz Recommend use solar panels 300Wpv DC MAX input current 20A AC MAX output power 260Watt DC MAX Open-circuit input-voltage 100VDC DC input voltage range 22~60VDC MAX output power factor 0.99 DC input Reverse voltage protection FUSE AC output voltage range (120V versions 90~160VAC)(230V versions 190~260VAC) AC frequency range 48~63Hz Output current total harmonic distortion THDIAC <5% AC Phase <0.5% Islanding protection VAC;f AC Output short circuit protection Current-limiting Show LED mode power instruction voltage instruction AC frequency instruction over-voltage instruction Communication way 60KHz modulation,power line carrier-current communication Standby Power <1W Night Power <1W Ambient temperature range -25 ~60 Humidity 0~100%(Indoor Type Design) Waterproof Indoor Type Design Electromagnetic Compatibility EN50081.part1 EN50082.part1 Power System Disturbance EN61000-3-2 EN62109 Network test DIN VDE 1026 UL1741 Certificate CE Packing and weight Net weight 0.66kg Gross weight 0.78kg Size (L x W x H) 215 78 50mm Package (L x W x H) Inner box:31x12x8.5cm Big box:54x33x51cm Installation Back of solar panel 第 3 页

Operation Instruction 1. Use the 4*10mm screws to fix the inverter on the holder of the solar panel. Show below: Finished all the connections, confirm the AC and DC connection is right. The LED is red when the AC power is unconnected and the LED shows like below when the AC power is connected. The LED shows like below: A) Power failure display LED in red: 1. Power cut off 2. Output failure 3. Power grid fault 4. DC low- voltage display(protection) 5. DC over-voltage display(protection) 6. Over temperature display(protection) B) Power adjust display 1. LED in green, but flashing, it means power is in adjusting condition. 2. LED in green and steady, it means the power is locked, and the inverter works. Single-phase connection Connection electrical diagram of the solar inverter used in single-phase power generation system, show below 2. Connect the two DC terminal of the PV to the inverter, positive to positive, negative to negative. Show below: 3. Connection of AC output, connect the AC wire to the AC waterproof plug. Show below: Three-phase connection Connection electrical diagram of the solar inverter used in three-phase power generation system, show below 4. Connect the AC plug to the inverter s AC terminal. Show below: LED display Notes: ---Please connect the inverter following the operation instruction show above. If have any question please contact with relative persons. 第 4 页

--- Non-professionals do not disassemble. Only qualified personnel may repair this product. --- Please install inverter in the low humidity and well-ventilated place to avoid the inverter over-heating, and clear around the inflammable and explosive materials. --- When using this product, avoid children touching, playing, to avoid electric shock. --- Connected solar panels, battery or wind generators DC input DC power supply cable. Laboratory test results and waveforms The following figure shows the grid voltage, grid current, system transfer and island transportation MPP voltage waveform. In the following oscilloscope images, waveforms color and have the following meanings: CH1 = yellow color is the solar micro- CH2 = green color is the solar micro-inverter input current CH3 = purple color is the power grid voltage CH4 = magenta color is the power grid current System islanding operation: When the AC voltage power grid in the zero value at the failure of the system shut down Grid voltage and grid current Night mode: When the input voltage is less than the low-voltage threshold, the system shut down System islanding operation: power failure, the system shut down PV panels voltage ripple and current ripple System islanding operation: When the AC voltage peak power failure the system shut down Accessories for product 1. One warranty card 2. One user manual 3. One certificate of quality 第 5 页