Preventative Maintenance

Similar documents
Pump Maintenance - Repair

Lift Station Condition Assessment, Repair and Rehab the Full Monty. How to Participate Today

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Oil and Coolant Circulating Heating System. Model - OCSM

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

MODEL INSTALLATION INSTRUCTIONS

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Troubleshooting with ABS Service Data Kit

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

Trouble Shooting. Pump

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Flygt N-pump series SelF-cleaNiNg pumps with SuStaiNed high efficiency

Chapter 7 Hydraulic System Troubleshooting

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Hydraulic Troubleshooting PRESENTED BY

This instruction is valid for all ACD pump models shown on page 2

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

1/3 HP Submersible Sump Pump with Vertical Float Switch

13. REAR WHEEL/BRAKE/SUSPENSION

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

AC Electric Motors best practice

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

INSTALLATION & OPERATING INSTRUCTIONS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

CARING FOR YOUR WATER HEATER

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Maintenance and Service Instruction

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

AC Submersible Pump Motors Installation & Operating Manual

SunMaxx Solar Filling Station Operating Instructions

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

WGL20, WGL20H, WGL20F Grinder Pumps

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

BOWIE PUMPS OPERATION - MAINTENANCE

TECHNICAL INFORMATION Bulletin

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Engine, Drive Train, and Hydraulic Repair Indicator Quick Reference Guide

Evaluate, Clean, and Tune Guidance

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Gas Oven Repair Guide

TROUBLESHOOTING GUIDE

Specifying a Variable Frequency Drive s

IMPORTANT SAFETY NOTICE

Service and Maintenance. SEW-EURODRIVE Driving the world

FUEL-16, Troubleshooting Fuel Supply Problems

Technical Guide 08/15/14

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / SC / SC / 1250SC / 1600SC / 1800SC / 2000SC

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

, User s Manual

Why and How we Use Capacity Control

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Diesel Engine Driven Generators Page 1 of 6

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

OPERATING AND MAINTENANCE INSTRUCTIONS CLIMATE CONTROL/INDUSTRIAL

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

BERMAD Fire Protection

Single Phase Soft Starter

Federal Wage System Job Grading Standard for Electrical Equipment Repairing, Table of Contents

Webinar Series. Committee. Disc Brake Wheels Off Inspection and Reline. Presents

Online Hydro Machinery Monitoring Protection, Prediction and Performance Monitoring Solutions

OPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE PUMP

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

. Failure. Analysis... Report...

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

accidents which arise due to nonobservance and the safety information herein.

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Service Instructions Manual B Chicago Pump type VOS and VPM non-clog pumps

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

PC1130 Electric Air Compressor

Float and Thermostatic Traps Series H, C and X

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Dry Pit Solids Handling Pumps

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Pump and Valve Components and Maintenance

12. REAR WHEEL/BRAKE/SUSPENSION

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

PC1131 Electric Air Compressor

AC-Synchronous Generator

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Transcription:

Submersible Pumps & Motors Preventative Maintenance June 7, 2012 Randy Cowden Sales Representative

Submersible Pump Applications Submersible Pumps Can Operate Submerged In A Wet Well Or Permanently Mounted In A Dry Well Pump Preventative Maintenance Should Include The Pump Environment & Equipment, The Pump Itself And The Controls Proper Preventative Maintenance Of The Well Will Increase The Longevity Of The Pumps Regular Control Panel Checks Can Give Forewarning Of Potential Problems Annual Pump Inspections Can Increase The Life Of The Pump And Prevent Catastrophic Failures 2

Maintenance & Troubleshooting Safety Follow All Safety Guidelines When Working Around Lift Stations And With Mechanical & Electrical Equipment Check For Any Hazards Including Trip, Fall, Chemical And Dangerous Gases Use Proper Safety Gear Including Proper Safety Shoes, Hard Hats, Harnesses, Gas Monitors And Gloves Only Qualified Service Personnel Should Perform Work And Should Never Work Alone Do Not Ignore Health Hazards. Observe Strict Cleanliness A First-aid Kit Must Be Handy Use Lock-out Tag-out Procedures On Electrical Equipment 3

Wet Well Preventative Maintenance Properly Ventilate Well And Check For Gases Before Observing Wet Well Remove Debris From Top Of Wet Well Water Level Check Condition Of Power Cables Check Guide Rails 4

Wet Well Preventative Maintenance Clean Level Sensors (Floats, Transducers) And Check For Proper Operation Clean Floats And Check By Tilting Check Transducers By Using Known Water Height and Verify In Controls Check Pump Connection For Proper Sealing If Water Swirls Or Sprays Around Discharge Connection, This Could Indicate Improper Sealing or Sludge Build Up Around Pump 5

Wet Well Preventative Maintenance Pump Lift Station Down And Clean Side Walls Off Flygt Pumps Can Be Operated Until The Pumps Snore To Help Remove Debris And Decrease Build Up. (Check Other Manufactures If Pumps Can Be Operated Continuously This Low.) Use Two Pumps To Pump Down Station To Increase Velocity In The Discharge Piping i And Reduce Chance Of Clogging. 6

Submersible Dry Pit Preventative Maintenance Follow The Same Guidelines For The Wet Well Check Ventilation Equipment Properly Ventilate Dry Well And Check For Gases Before Entering Follow Safety Codes Before Entering The Dry Well And Before Opening The Wet Well 7

Submersible Dry Pit Preventative Maintenance The Dry Well Needs To Be Checked For Cracks And For Water Leaks In The Walls Sump Pump Needs To Be Checked For Operation Fittings Need To Be Checked For Tightness Gate & Plug Valves Need To Be Operated To Prevent Seizing i And Allow Full Closure When Needed 8

Submersible Pump & Motor Submersible Pumps And Motors Are One Unit (No Couplings, Impeller Is Directly Attach To The Motor Shaft) Mechanical Seals Isolate Motor From Pumped Media Most Submersible Pumps Use Upper & Lower Mechanical Seals That Provide A Seal Chamber For Lubricating & Cooling The Seals Mechanical Seal Failure Can Be Cause By Erosion, Vibration Or Thermal Shock Water Intrusion Into The Motor Chamber Causes Motor Failure, Leak Sensors Notify The Onset Of A Leak Motor Failure Can Also Be Caused By Electrical Malfunction 9

Typical Submersible Pump JUNCTION CHAMBER MOTOR COMPARTMENT SEAL OIL CHAMBER HYDRAULIC WET END 10

Typical Small Submersible Pump JUNCTION CHAMBER MOTOR COMPARTMENT SEAL OIL CHAMBER HYDRAULIC WET END 11

Flygt N-technology Working together for higher efficiency N-impeller Insert ring Guide pin Relief groove Pump housing Update Presentation Name or Confidentiality Status Under Footer Menu 12 6/22/2012 12

Compact Mixers/Pumps 4600 - Series

Horizontal Axial Flow Pumps PP4600 - Series

15

16

Pump Preventative Maintenance (Annually) Run Pump And Listen For Any Unusual Noise In Upper & Lower Bearings Remove Pumps And Clean Off Build Up Check For Build Up Around Power And Lifting Cables/Chain Check Impeller Clearance Check For Clogging 17

PUMP DRAWS HIGH AMPS MAY BE CLOGGED 18

Beaver 19

Pump Preventative Maintenance (Annually) Remove Pump From Volute To Remove Any Stringy Material From Around Impellers And Any Lodged Or Debris Build Up Check Oil Chamber For Oil Condition And Level Plus Change Oil (Properly Dispose Of Old Oil & Replace O-Rings) Meggering The Power Leads Insulation Check Water Intrusion Check Cable Damage Check 20

Checking A Pump With Multimeter Check Each Power Lead To Pump Ground Lead Open Winding Is Not Grounded Resistance Winding Is Grounded Check Between Power Leads To Determine Resistance Values Shows What Voltage Pump Is Wired For Open Circuit Could Be Open Windings Or Cut Cable 21

Checking A Pump With Megger Disconnect Pump Power And Ground Leads Check With A Cool Motor Check Power Lead To Pump Ground Lead High Megohm Good Motor Medium Megohm Used Motor, Hot Motor or Slightly Wet Low Megohm Deteriorated Motor Insulation, Bad Cable, Wet Windings Low-No Megohm Burnt Motor, Grounded Leads, Soaked Cable or Motor Do NOT Megger Pump If It Has Internal Contactors Or Capacitors (Single Phase) 22

Check Pump Sensor Leads Check Manufacture s Ratings For Sensor Leads And To Determine Proper Test Procedure And Function Usually Sensor Leads Are Checked by Resistance (1200 1550 normal) Open Resistance Will Show Fault, Possible Open Thermals (~) Resistance Values On Leak Sensors Can Determine If A Leakage Has Occurred (300) 23

MOISTURE IN PUMP 24

Control Panel Preventative Maintenance Check In-Coming Power Check Run Time Meters And Compare Previous Run Times Check Operating Amps For Each Pump And Compare To Previous Readings & Full Load Ratings Check All Electrical Components And All Connections Including Surge Arrestors, Alternators, Relays And Pump Sensors 25

Control Panel Preventative Maintenance Check Alarm Light & Horn Operation De-energize energize Panel, Check And Tighten All Connections Check Conduit For Tightness And Sealing (Replace Sealing When Floats Or Pumps are Pulled Through) Use A Mild Protective e Spray On The Door Gasket To Ensure Watertight Integrity 26

Pump Troubleshooting Pump is operating but not pumping Air Locked (Pump will pull lower than usual amps) Pump Is Not Sitting On The Discharge Connection Properly Valves stuck or closed (Pump will pull lower than usual amps) Debris in front of inlet pipe (Can possibly hear cavitation or rattling in pump) Wear Ring is worn out or Impeller clearance needs adjusted Pump is turning backwards (Three Phase Only) (Pump may vibrate more) Loose or Broken Impeller (Pump will pull lower than usual amps) Verify check valve on opposite side is closed (Will see return flow around pump) 27

Pump Troubleshooting Pump will not operate Check phase monitor is tripped Check for thermal/leak sensor is tripped Check Starter overloads Check for Low Level Shut off Pump will operate but motor protection ti trips Check the impeller Check incoming power (out of phase) Megger the pump for wet or burnt motor 28

OVERHEATED MOTOR 29

Types of Electrical Motor Failures Winding Single-Phased A single-phased winding failure is the result of an open in one phase of the power supply to the motor. The open is usually caused by a blown fuse, an open contactor, a broken power line or bad connections. o Phase Damage Due to Unbalanced Voltage Thermal deterioration of insulation in one phase of the stator winding can result from unequal voltage between phases. Unequal voltages usually are caused by unbalanced loads on the power source, a poor connection at the motor terminal, or a high resistance contact (weak spring). Note: A one-percent voltage unbalance may result in a six- to ten-percent current unbalance. 30

Types of Electrical Motor Failures Winding Damaged Due to Overload Thermal deterioration of the insulation in all phases of the stator t winding typically is caused by load demands exceeding the rating of the motor. Note: Under-voltage and over-voltage (exceeding NEMA standards) will result in the same type of insulation deterioration. Damage Caused by Locked Rotor Severe thermal deterioration of the insulation in all phases of the motor normally is caused by very high currents in the stator winding due to a locked rotor condition. It may also occur as a result of excessive starts or reversals. 31

Types of Electrical Motor Failures This types of insulation failures is typically caused by contaminants, abrasion, vibration or voltage surges. Winding Grounded at Edge of Slot Winding Grounded in the Slot Winding Shorted Phase-to Phase Shorted Connection Winding with Shorted Coil 32

33

Questions Any Questions? 34