MGC 1 Multi Gun Control

Similar documents
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

5800 Temperature Sensor Cable Assembly

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Front brakes (FN- 3), servicing

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

Wolflite Safety Handlamp H-251E

PTU Series Ultrahigh-Purity Pressure Transducers

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Installation Instructions S

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

TRIMMING UNIT/DIAMOND MACHINE TST.13

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Combo heat press machine. Instruction

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Original Assembly Guide

Stainless Steel Single and Dual Circulation Kits

2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.

Nordson Automatic Spray Gun Support Kits

SunMaxx Solar Filling Station Operating Instructions

Bulb Replacement REPLACING BULBS WARNING

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

V94 BULK TAPE DEGAUSSER


Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Installation Instructions: Electrical System for Towing Hitch... 3

VOYAGER 570G. 744A Sprayer Control

Operating Instructions Drill rig DRU160

Retrofit Instructions Installing a Sport Heated Steering Wheel - Leather, Multifunction BMW X5, E53,

LT SERIES User s Manual

Operating Instructions Bedienungsanleitung Mode d emploi

Air Vantage 500 Kubota

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Windshield Wiper System

Triac Printed Circuit Board Replacement

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

How To Use A Power Supply Unit (Upu)

430 Power/Electronics Replacement

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

M A N U A L

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

TMS TANK MANAGEMENT SYSTEM

This instruction is valid for all ACD pump models shown on page 2

Installation instructions, accessories. Alarm, siren. Volvo Car Corporation Gothenburg, Sweden. Instruction No Version Part. No

Features: Mounting the Optic

Operation Manual Magic Bowling. Warning Please read this manual carefully before using this machine

SERVICE MANUAL. Permobil C500. Power wheelchair

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Modular I/O System Analog and Digital Interface Modules

AUTO TRANS DIAGNOSIS Article Text 1998 Volkswagen Passat This file passed thru Volkswagen Technical Site -

4.3-inch Back-Up Camera

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

D I G I T A L C L A M

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Polaris 9300 & 9400 Series Robotic Cleaner

BULB REPLACEMENT BROCHURE

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

Operating Instructions

OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

BODY-12, Door Handle - Removal, Installation, and Adjustment

Front axle components, overview

INSTALLATION INSTRUCTIONS

Quickie Rhapsody Service Manual

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

Solstice/Sky Water Pump Replacement

Windshield Wiper System

SENSOR FAUCETS. OPTIMA ETF-80 Faucet. P a r t s G u i d e 24 VAC HARDWIRE FAUCETS SLOAN VALVE COMPANY SEYMOUR AVENUE FRANKLIN PARK, IL 60131

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

Installation and Operation Manual. Shutdown Solenoid for UG Governor. Manual (Revision T)

IH E Sigma Island 90

GPS AutoSteer System Installation Manual

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

Round Housing with Side Ports

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Beam Laser Pointer Service Manual

200W DISCRETE POWER AMPLIFIER K8060

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

MCR1900 Media Converter 19-Slot Chassis

ELECTRIC BICYCLE USER MANUAL

Transcription:

E Operating instructions and Spare Parts List Multi Gun Control GUNS 2 3 4 5 6 7 8 00 90 80 70 60 50 40 30 20 0 kv 000 900 800 700 600 500 400 300 200 00 µa GEMA VOLSTATIC 0 An ITW Company 3

4

Table of contents Multi Gun Control............................................... Fields of application............................................. Description of control module.............................. Technical data for the Multi Gun Control............................. 2 Installation of the............................................... 3 Preparatory steps for initial start-up....................................... 4 a) Connecting the PG 2-A / PG -A powder guns...................... 4 b) Functional check............................................. 5 c) Shut-down................................................. 5 Repairing electrical parts................................................ 6 a) Replacing the bulb in the main switch............................ 6 b) Replacing the fuse - F........................................ 6 c) Replacing a potentiometer..................................... 6 d) Replacing the electronics board (PCB)............................ 7 Trouble shooting guide................................................. 8 Control module - Spare Parts..................................... 0 5

6

Multi Gun Control Fields of application The electrostatic powder gun control is designed to control up to eight (8) PG 2-A or PG -A powder guns simultaneously. Description of control module The corona voltage can be optionally regulated on the front panel with the regulating knob (3). This knob serves two functions, when it is in the depressed mode (pushed in) the kv setting/ reading (2a - output voltage) of the guns can be made using the LED (Light Emitting Diode) high voltage scale (2) to the left of this knob. When the knob is pulled out the µa (2b - output current) setting/reading can also be made on the LED high voltage meter (2). When the knob is turned fully counter clockwise to the stop no voltage/current is measured at the guns. The gun voltage/corona discharge is identical on all guns. Beside the LED meter display for the gun voltage, and corona discharge, on the front panel are also 8 LEDs () for the operation of each gun. The green main ON/OFF switch (4) is located on the right-hand side. When the control module is switched off the switch centre grip is pointing to the zero (upwards). The powder gun control can be easily adapted to suit all available voltages. The power loss inside of control module is cooled by a heat sink with blower. The conveying air, and supplementary air to the injectors, and rinsing air to the gun is controlled (regulated) on the ADC Air Distribution Control. (See Op. Manual ADC ) GUNS 2 3 4 5 6 7 8 00 90 80 70 60 50 40 30 20 0 kv 000 900 800 700 600 500 400 300 200 00 µa GEMA VOLSTATIC 0 2 2a 2b 3 4 Front panel. Operation gun display 2. High voltage/corona current meter. 2a. Guns ON and kv setting/ reading. 2b. Guns ON and µa setting/ reading. 3. HV/corona current control knob. 4. Power switch. Figure

Technical data for the Multi Gun Control Electrical data Single-phase AC Selectable voltage : 0 V or 220 V Voltage selection is made on the inside of the electrical unit by reconnecting the wires on the transformer. The value of the fuse for 0 V is 6,30 AT and for 220 V is 3,5 AT. The equipment is delivered for operation at 220 V from the factory. Tolerance: +0% / -5%, Frequency : 50/60 Hz Connected load : 240 VA Rated output voltage (to each gun) : 0 V Rated output current (to each gun) :,2 VA Type of protection : IP 54 Temperature range : +0 o C to +40 o C (+50 o F to +04 o F) Dimensions Width : Depth : Height : 435 mm 300 mm 96 mm 2

Installation of the The Multi Gun Control is preassembled in the factory to a point where only certain cables must be connected at the rear of the control module. - Connect the solenoid valve cable from the ADC Air Distribution Control to the connection 2 - Connect the 6-pin-cable from the distribution box to the connection 4 - (Optionally) Connect the external signal cable to the connection 3 - Connect the mains cable to the connection 4 5 2 3 6 7 Rear panel. Mains connection 5. Fuse F 2. ADC solenoid valve connection 6. Heat sink 3. External signal input 7. Blower 4. 6-pin-plug Figure 2 3

bar Preparatory steps for initial start-up a) Connecting the PG 2-A / PG -A powder guns. Connect the cables (7) with the 7-pin connector to the distribution box (8). 2. Connect the hoses for conveying air to the booster conveying air (3) and to the guns. 3. Connect the hoses for supplementary air to the booster supplementary air (4) and to the guns. 4. Connect the hoses for rinsing air to the booster rinsing air (5) and to the guns. 5. Connect the powder hoses to the guns and to the injectors (6). 7 6 8 5 4 3 0 2 3 bar 4 0 2 3 bar 4 0 2 3 4 2 00 000 90 900 80 800 70 700 GUNS 0 60 600 50 500 2 3 4 5 6 7 8 40 400 30 300 20 200 GEMA 0 00 VOLSTATIC kv µa Multi Gun Control 5 Booster rinsing air 2 ADC Air Distribution Control 6 PI injectors 3 Booster conveying air 7 Gun cable 4 Booster supplementary air 8 Distribution box Figure 3 4

b) Functional check See trouble shooting guide on page 8 for malfunctions.. Switch on the main switch (4) of the control module. The is under power when the lamp inside the green main switch illuminates. The PG 2-A / PG -A guns begin to spray. 2. Depress the high-voltage control knob (3) on the control module, if not already in this position, and turn to the left-hand stop. 3. The lowest left-hand LED (2a) on the high voltage/corona current meter (2) should illuminate. The equipment is active. 4. Set the high-voltage (or corona current) by turning the control knob (3) until the desired value is achieved. GUNS 2 3 4 5 6 7 8 00 90 80 70 60 50 40 30 20 0 kv 000 900 800 700 600 500 400 300 200 00 µa GEMA VOLSTATIC 0 2 2a 2b 3 4 Figure 4 When all the above checks have been successfully completed, the gun is ready for use. If it fails to function correctly, consult the trouble shooting guide on page 8. c) Shut-down - Switch off the control module. The adjustment for high-voltage must not be changed. 5

Repairing electrical parts The following repairs may be carried out by the user. a) Replacing the bulb in the main switch. Turn the main switch off and disconnect the mains cable of the control module. 2. Unscrew the black retaining ring () of the main switch on the front of the control module and remove the green switch grip. 3. Push the special extractor (supplied) against the defect bulb and turn counter-clockwise to the stop. The bulb can now be removed easily. 4. Replace the new bulb so that the pins on the bulb fit into the slots of the bulb holder. Push the bulb carefully down as far as it will go and turn clockwise. 5. Check that the bulb is seated correctly. 6. Replace the green switch grip and screw on the retaining ring. Make sure that the white stripe is pointing upwards. 7. Reconnect the Mains cable of the control module. b) Replacing the fuse - F. Unscrew the cap of the fuse holder with a wide bladed screwdriver or a small coin. 2. Remove the defective fuse from the control module and replace with a new fuse for the correct line voltage (F= 3.5 AT for 200-240V / 6.30 AT for 00-20V). 3. Replace the cap of the fuse holder. c) Replacing a potentiometer. Remove all electrical connections on the rear of the control module. (2.) Unscrew the retaining screw at the lower rear of the control module 3. Slide out the module from the housing and place on a clean, flat surface. ATTENTION Do not pull out by the control knobs. Push the module out from behind. 4. Unscrew the screws of the cover plate and carefully remove the cover. 5. Unscrew the grub screw of the potentiometer knob with an Allen key and pull the knob off the spindle. 6. Remove the locking nut (with a correct sized spanner) and washer, pull the potentiometer out (to the inside of the housing). 7. Replace the new potentiometer and carefully reassemble the unit in the reverse order to which it was dismantled. Do not cross the locking nut threads. ATTENTION The contacts are not numbered, therefore, the potentiometer should only be replaced by a specialist! When replacing the cover care should be taken that the gasket is not displaced. 6

d) Replacing the electronics board (PCB). Remove all electrical connections on the rear of the control module. (2.) Unscrew the retaining screw at the lower rear of the control module 3. Slide out the module from the housing and place on a clean flat surface. ATTENTION Do not pull out by the control knobs. Push the module out from behind. 4. Unscrew the quick-release screws and carefully remove the cover. 5. Loosen the two nuts (2) and remove the screws completely from the board. 6. Lift the board out carefully, making sure that the LED scale is not damaged in the process. 7. Carefully remove plugs A and B (Never pull on the cables). The plugs should not be connected to the wrong socket on assembly. Reassemble in the reverse order. When replacing the cover care should be taken that the gasket is not displaced. 240 230 200 B A 20 0 00 0 2 2 Figure 5 7

Trouble shooting guide Faults Green lamp does not illuminate although control module has been switched on. Gun does not spray powder although the control module is switched on Gun sprays powder, powder does not adhere to the workpiece Causes Operating error: Module is not switched on No power: Control unit is not connected to Mains Fuse F defective External power line fuse defective In equipment: Lamp defective Electronics board (PCB) defective In the gun: Gun cable defective High voltage section defective - No conveying air - Electronics board (PCB) defective - High voltage too low - Gun connector, gun cable or gun cable connector is defective - High voltage cascade is defective - Electronics board (PCB) defective Remedies Switch on Connect sprayer with power cord to Mains Replace Replace or reset Replace Mail in for repair Replace, eventual mail in for repairs Mail in gun for possible repairs See ADC or Booster Mail in for repair Increase the high voltage on the control module Replace defective item or mail it in for repair Mail in the shaft of the gun for repair Mail in for repair Gun sprays powder, high voltage present, powder does not adhere to the work piece. - Work piece not properly grounded Check the ground connection, also refer to "Safety rules" 8

Spare Parts List Ordering Spare Parts When ordering spare parts for your powder coating booth, please indicate the following specifications:. Type, and serial number of your powder coating booth 2. Order number, quantity, and description of each spare part Example:. Type Serial no: 800 496 2. Order no: 246 573, piece, T-Piece - /8"-ø 8-ø 8 mm When ordering cable or hose material the length required must be given. The spare part numbers of this yard/metre ware is always marked with an *. The spare part number of yard/metre ware always begins with xx xxx. All wear parts are marked with a #. All dimensions of plastic hoses are given as external and internal diameters : e.g. ø 8 / 6 mm = 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d). 9

Control module - Spare Parts 2 Main board (complete) 346 640 3 Heat sink 346 543 5 Printed circuit board CB 3 346 772 Switch 235 9 2 Adapter fixture 235 920 3 Contact unit 235 938 4 Lamp unit 235 946 5 Bulb 24 V/2W 235 954 7 Regulating knob 200 069 8 Clamp nut 200 700 9 Washer 200 27 20 Rubber seal 336 300 2 Potentiometer - complete 370 355 22 Fixed plug, with gasket (for Mains connection) 200 409 23 Socket - 4 pin 205 249 24 Socket - 7 pin 200 093 25 Fuse holder 200 3 26 Fine wire fuse (slow blow) - 220 V, 3,5 AT 200 07-0 V, 6,30 AT 20 570 27 Blower 240 V 2 W 242 80 28 Plug grommet 235 989 29 Printed circuit board CB 2 346 748 30 Quick-release screw 20 625 3 Plug insert 2 354 32 Plug housing 242 837 33 Protective grating 242 829 0

Control module 30 2 22 25; 26 23 24 9 8 7 20 29 3 4; 5 2 2 5 28 33 32 3 3 27 Figure 6

Documentation Edition - July 992 Copyright ITW Gema AG, CH-905 St. Gall All technical products from ITW Gema AG are constantly being developed based on our continuing research and applications. The data found in this publication may therefore change at any time without prior notification. Printed in Switzerland 2