Digital mammography with multi-electrode ionization chamber

Similar documents
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY

Digital Mammography Update: Design and Characteristics of Current Systems

Physics testing of image detectors

S2000 Spectrometer Data Sheet

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

High resolution and two-dimensional focal plane detector for intermediate energy heavy ions

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Development of on line monitor detectors used for clinical routine in proton and ion therapy

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Information about the T9 beam line and experimental facilities

2 Absorbing Solar Energy

A.Besson, IPHC-Strasbourg

ELECTRON SPIN RESONANCE Last Revised: July 2007

Atomic and Nuclear Physics Laboratory (Physics 4780)

Coating Thickness and Composition Analysis by Micro-EDXRF

Design of analog-to-digital converters for energy-sensitive hybrid pixel detectors

Remote RadEye Product Family

A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY

Dose enhancement near metal electrodes in diamond X- ray detectors. A. Lohstroh*, and D. Alamoudi

Solar Cell Parameters and Equivalent Circuit


The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Radiation Strip Thickness Measurement Systems

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Evaluation of various planar gaseous detectors with CsI photocathodes. for the detection of primary scintillation light from noble gases

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

How Does One Obtain Spectral +Imaging Data

CMS Tracker module / hybrid tests and DAQ development for the HL-LHC

Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

A study of breakdown limits in microstrip gas counters with preamplification structures

Gamma and X-Ray Detection

Construction of an Alpha- Beta and Gamma-Sensitive Radiation Detector on the Basis of a Low-Cost PIN-Diode

ENERGY PER PHOTOELECTRON IN A COINCIDENCE LIQUID SCINTILLATION COUNTER AS A FUNCTION OF ELECTRON ENERGY. Donald L. Horrocks

Characteristic and use

Lecture 14. Point Spread Function (PSF)

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Irradiation Field Size: 5cmX5cm 10cmX10cm 15cmX15cm 20cmX20cm. Focus-Surface Distance: 100cm. 20cm Volume of Ion Chamber : 1cmX1cmX1cm

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Results from first tests of TRD prototypes for CBM. DPG Frühjahrstagung Münster 2011 Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2

Appendix A. An Overview of Monte Carlo N-Particle Software

Wir schaffen Wissen heute für morgen. Paul Scherrer Institut Bernd Schmitt Jungfrau, Mönch and Eiger: Detector Development at the Swiss Light Source

Archimedes Palimpsest Metadata Standard XRF Extensions DRAFT

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Design and Construction of a First Prototype Muon Tomography System with GEM Detectors for the Detection of Nuclear Contraband

FREQUENCY RESPONSE ANALYZERS

Gaseous Micropattern Detectors In Astrophysics, Radiology And Plasma Physics *

Silicon Drift Detector Product Brochure Update 2013

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

Signal to Noise Instrumental Excel Assignment

On the first Townsend coefficient at high electric field

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Solar Photovoltaic (PV) Cells

Introduction to CCDs and CCD Data Calibration

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

Silicon Sensors for CMS Tracker at High-Luminosity Environment - Challenges in particle detection -

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Page: 1 of 6 Page: 1 of 6

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Project 2B Building a Solar Cell (2): Solar Cell Performance

Sound absorption and acoustic surface impedance

TOF-PET DETECTOR CONCEPT BASED ON ORGANIC SCINTILLATORS

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Dynamic Neutron Imaging

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

Basic RTD Measurements. Basics of Resistance Temperature Detectors

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Comparison of Epson scanner quality for radiochromic film evaluation

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Plasma Activated Fuel Cells

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

World-first Proton Pencil Beam Scanning System with FDA Clearance

INTRODUCTION. A. Purpose

SPADIC: CBM TRD Readout ASIC

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

Flex Circuits for the ATLAS Pixel Detector

High-resolution bio-imaging with liquid-metal-jet x-ray sources

Performance of Carbon-PTFE Electrodes and PTFE Separators in Electrochemical Double Layer Capacitors (EDLCs)

Solid State Detectors = Semi-Conductor based Detectors

Development of High-sensitivity and High-resolution Digital Mammography System AMULET

Radiation Safety Characteristics of the NOMAD Portable X-ray System

C.-K. Ng. Stanford Linear Accelerator Center. and. T. Weiland. University oftechnology. FB18, Schlossgartenstr. 8. D64289, Darmstadt, Germany.

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Transcription:

Nuclear Instruments and Methods in Physics Research A 454 (2000) 130}135 Digital mammography with multi-electrode ionization chamber V.R. Groshev, V.R. Kozak, V.I. Nifontov, S.M. Pishenuok, A.A. Samsonov, L.I. Shekhtman*, V.I. Telnov Budker Institute for Nuclear Physics, 630090 Novosibirsk, Russia Abstract For viewing micro-calci"cations smaller than 100 μm investigation of image formation in mammography shows that a signi"cant dose to the patient is imperative. We propose a novel one-dimensional Multi-electrode Ionisation Chamber (MIC), with high spatial resolution, and lowered doses. In this work, "rst results from a prototype are presented. High spatial resolution is demonstrated working with Xe mixture at high pressure. An addition of a Gas Electron Multiplier (GEM) allowed an improvement in sensitivity up to almost single-photon level. 2000 Elsevier Science B.V. All rights reserved. 1. Introduction Radiography of mamma gland (mammography) is still one of the most often used examinations for diagnostics. In order to see some limitations of this method we consider basic features of image formation in mammography. The mamma gland is compressed down to &5 cm thickness. It is combined of soft tissues with some "bre-like and node-like structures, with size down to 1 mm and contrast in 20 kev X-rays down to &1%. The most di$cult objects to view are micro-calci"cations that are composed of Ca (PO ) OH with the size down to 0.1 mm and less. If we assume no intrinsic noise in the detector, the noise at the image will be proportional to the * Corresponding author. E-mail address: lshekhtm@inp.nsk.su (L.I. Shekhtman). square root of X-ray #ux passing through the object. In Fig. 1 the image signal-to-noise ratio is shown as a function of X-ray energy. Here, we took the contrast of micro-calci"cation inside 4, 5 and 6 cm of soft tissue as a signal and the square root of #ux after the object, as noise. From the "gure we can see that the optimal energy to view such an object is &20 kev. In Fig. 2 a contrast of 0.1 mm size calci"cation introduced into 5 cm of soft tissue (1}1 mixture of muscle and fat) is shown as a function of X-ray energy. The contrast at 20 kev is equal to &10%. If a pixel size is less than 100 μm, in order to view the object, pixel noise has to be less than the contrast by a certain factor [1]. It means that the detector has to accumulate several hundred photons per pixel in this region. Following the simple assumption about quantum-limited noise at the image, one can "nd that in order to view a micro-calci"cation, the #ux at the surface of an object has to be reversed proportional to the size of micro-calci"cation to the power 4 (see 0168-9002/00/$ - see front matter 2000 Elsevier Science B.V. All rights reserved. PII: S 0 1 6 8-9 0 0 2 ( 0 0 ) 0 0 8 1 4-7

V.R. Groshev et al. / Nuclear Instruments and Methods in Physics Research A 454 (2000) 130}135 131 Fig. 1. Signal-to-noise ratio versus X-ray energy for di!erent thickness of the object. Fig. 3. Dose needed to view a micro-calci"cation as a function of size of this micro-calci"cation. Fig. 2. Image contrast of 0.1 mm calci"cation in 5 cm thick soft tissue as a function of X-ray energy. Appendix A). In Fig. 3 we show the result of calculations of the object surface dose which is necessary to view a micro-calci"cation as a function of the size of this micro-calci"cation. From the "gure we can see that in order to view a micro-calci"cation below 0.1 mm the surface dose has to be comparable or higher than 1 R (&0.01 Gy). Limitation on the dose level becomes even stronger if a one-dimensional detector is used in scanning mode. In this case the tube load becomes higher than in case of a true two-dimensional detector by a factor that is equal to the ratio of total exposure time over exposure time of one line. This number represents the number of lines in an image. Assuming that we can get a mammography tube with a maximum load capacity of 600 mas [2] and using data from Ref. [3] to convert tube load into the dose at a distance of 50 cm, we get the maximum dose that can be delivered to the surface of an object is &10 mr (1000 lines in the image). This limit is marked with a dashed line in Fig. 3. From the "gure we see that in this case, a minimum size of calci"cation which can be viewed is about 0.2 mm (for 5 cm thick soft tissue). In this paper we propose to build a detector for digital mammography based on one-dimensional multi-electrode ionisation chamber (MIC). The chamber works without any ampli"cation or with small ampli"cation (&10) provided with Gas Electron Multiplier (GEM). The "rst results obtained with the prototype of such detector are presented. 2. Detector description and results from the prototype Ionisation chambers have been used for X-ray imaging in angiography with synchrotron radiation [4] and for whole-body radiography [5]. This detector is simple in construction, robust and can MEDICINE/BIOLOGY

132 V.R. Groshev et al. / Nuclear Instruments and Methods in Physics Research A 454 (2000) 130}135 provide necessary e$ciency, rate capability and spatial resolution. We have designed a multi-electrode ionisation chamber for mammography that consists of a multi-strip plane made on printed circuit board (PCB) together with the front-end electronics. The strips are directed to the source of radiation placed at a distance of 50 cm. The pitch of the structure at the wide side is 125 μm. Each strip is connected to the input of integrator array chip RL0128MB produced by EG&G Reticon [6]. The integrator chip contains 128 channels of low-noise integrators with analog bu!er and multiplexer. The output of each chip is connected to ADC which converts signals to digital form synchronously with the readout of the chip. Information from the output of ADC is stored in 128-word bu!er. Complete detector contains 12 cells with integrator chip, ADC and memory bu!er. The total number of channels is 1536. All memory bu!ers will be read out through Ethernet link to Pentium PC. The PCB with electronics and multistrip structure is put into a cylindrical high-pressure box made of aluminium alloy with the entrance window of 1 mm thick carbon "bre. Highvoltage electrode that pushes ionisation down to the multi-strip structure is placed 2 mm above the PCB (Fig. 4). Tests of the front-end electronics and main parameters of the detector have been performed. The Fig. 4. Cross-section of the MIC for mammography. 1 } Aluminium high-pressure box; 2 } gas volume; 3 } carbon "bre inlet window; 4 } PC board with multi-strip structure; 5 } drift electrode; 6 } read-out electronics. Fig. 5. Channel response function of the MIC prototype for 2 and 5 atm of Xe#CO gas mixture. prototype consists of a multi-strip structure with 200 μm pitch bonded to 64-channel version of the integrator chip with its output connected to the electronic cell described above. The high-pressure box with the PCB and drift electrode has been "lled with Xe}CO (80}20) gas mixture up to 5 atm. An X-ray tube with Mo anode has been used with maximum intensity at 18 kev. Spatial resolution of the prototype has been tested with the help of a 30 μm slit. The chamber was irradiated through the slit and channel response has been measured as a function of slit position. The result of the measurement is shown in Fig. 5 for 2 and 5 atm. Channel response curve for 2 atm has a halo that is suppressed at 5 atm. This halo is caused by higher-energy photoelectrons with long range. Detective quantum e$ciency (DQE) has been measured as a function of photon #ux through a single channel. Exposure time was tuned to 3 ms. The detector performed 100 exposures and readout cycles. RMS of the signal in each channel was calculated as well as the average value of the signal. Input #ux was calculated according to the calibration of X-ray tube current performed before. According to the de"nition DQE"(s/n) /(s/n) (1) where the notation s/n means signal-to-noise ratio. If N is the number of photons equal to noise rms

V.R. Groshev et al. / Nuclear Instruments and Methods in Physics Research A 454 (2000) 130}135 133 Fig. 6. DQE as a function of photon #ux per channel for two di!erent pressures of the gas mixture. Fig. 7. Signal as a function of GEM voltage. of a single channel and ε is the fraction of input #ux absorbed in the sensitive volume, then DQE"ε/(1#N/εN). (2) Here, N is average input photon #ux through a single channel within exposure time. From Eq. (2) we can see that at high #ux DQE is constant and equal to ε, and at low #ux it drops due to the intrinsic noise of the detector. Results of the measurements are shown in Fig. 6 for 2 and 5 atm. The values of DQE at high #ux agree very well with the calculation of the absorption of 18 kev X-rays in 30 mm layer of gas mixture with 3 mm dead zone. However, the DQE drops at around 1600 photons per channel that corresponds to &40 photons noise rms. According to the speci"cations of the integrator chip its noise is equal to 1500 electrons or approximately to two 18 kev photons. The chip does not contain any ampli"er at the output of the multiplexer. Signal from one 18 kev photon give at the output (15 pf feedback capacitor) &7 μv. One bin of 14-bit ADC with 5 V range corresponds to &300 μv. Hence, 1 ADC bin is equal to about 40 photons and therefore the ADC noise determines total noise of electronic chain rather than the integrator noise. In order to solve this problem and improve DQE we had to introduce some ampli"cation either to the electronic chain or into the detector itself. The Gas Electron Multiplier (GEM) was used to introduce uniform gas ampli"cation between the conversion region and multi-strip structure. GEM is made from thin kapton foil double clad with copper. Narrow holes are etched through the material. Gas ampli"cation starts in the holes when high voltage is applied between two sides of the structure. Detailed description of GEM and its properties can be found in Ref. [7]. The possibility of GEM operation at high pressure was studied in Ref. [8]. A 50μm thick GEM with 80 μm and 140 μm diameter and pitch of holes respectively has been inserted 1 mm above the multi-strip plane. Performance of the detector with GEM was tested at 2 atm. In Fig. 7 the dependence of signal versus GEM voltage is shown. Ampli"cation of more than 30 can be reached before the structure started to discharge. This ampli"cation allowed improvement of the sensitivity to almost single photon per ADC bin. GEM ampli"cation has improved the DQE at lower #uxes that can be observed in Fig. 8. Here we can see the comparison of DQE versus #ux performance with and without GEM. With GEM, DQE is stable in the range between 300 and 6000 photons/channel. In case without GEM, DQE was dropping at &2000 photons/channel already. Lower value of DQE with GEM can be explained by some misalignment of the foil that partly shadowed the beam. There is some drop of DQE at higher rates that can be explained by limited rate capability of GEM (note that 10 000 photons per MEDICINE/BIOLOGY

134 V.R. Groshev et al. / Nuclear Instruments and Methods in Physics Research A 454 (2000) 130}135 Appendix A. Calculation of the surface dose necessary to view a micro-calci5cation Fig. 8. DQE as a function of #ux per channel with GEM ampli"cation and without it. channel corresponds to &10 mm s #ux density). 3. Conclusions A simple analysis of image formation in mammography shows that micro-calci"cations smaller than 100 μm cannot be viewed without signi"cant dose delivered to a patient. We also showed that a scanning technique is possible with one-dimensional position sensitive detector and a powerful enough X-ray tube. A prototype of the one-dimensional Multi-electrode Ionisation Chamber (MIC) was tested, with the proposed electronic chain and low-noise integrator array chip. High spatial resolution with 5 atm Xe mixture was demonstrated. However, the DQE dropped at rather high X-ray #ux, explained by the low sensitivity of the electronic chain. Additional ampli"cation has been introduced with Gas Electron Multiplier that has provided multiplication of &30 at 2 atm. The DQE measured with GEM has been stable down to &100 photons/channel. Stable performance of the detector with GEM still has to be tested at higher pressures. We plan that the "nal system will include ampli"- cation stages in the electronic chain that will allow to use GEM at higher pressures with lower multiplication. We will de"ne the following notations used in the equations below. J #ux density at the surface of the object J #ux density after the object with calci"cation J di!erence between #ux density after the object without calci"cation and with calci"cation L thickness of the object a size of calci"cation (with cubic shape) μ linear absorption coe$cient in a calci"cation; μ linear absorption coe$cient of the tissue around calci"cation. Flux behind the object with calci"cation is equal to J"J exp[!(!a)μ!aμ] &J exp[!μ ](1!a μ). (A.1) The di!erence between the #ux behind the object with calci"cation and without is approximately equal to J&J exp[!μ exp[!μ ]!J ](1!a μ) "J a μ exp[!μ ]. (A.2) Total #ux through the calci"cation is N&J a μ exp[!μ ]. (A.3) In order to see the di!erence between the #ux behind calci"cation and behind soft tissue, the difference between the total #ux through the calci"cation and through the similar region nearby has to be larger than noise rms by a certain factor [1]. This factor is di!erent for di!erent observer but normally it is about or larger than 5. Thus N/N"5 (A.4) where N is total #ux through the region of background area equal to the calci"cation in size. From Eqs. (A.1) and (A.2) we obtain μaj exp[!μ ]&5 or J "25( μ)a exp[μ ]. (A.5) (A.6)

V.R. Groshev et al. / Nuclear Instruments and Methods in Physics Research A 454 (2000) 130}135 135 If factor K is the conversion between the #ux density and dose, then the surface dose is equal to D"K 25( μ)a exp[μ (A.7) ]. References [1] A. Martinez-Davalos, R.D. Speller, J.A. Horrocks, D.J. Miller, S.E. Baru, A.G. Khabakhpashev, O.A. Ponomarev, L.I. Shekhtman, Phys. Med. Biol. 38 (1993) 1419. [2] Phillips Medical Systems, private communications. [3] V.V. Kljuev (Ed.), Pentgenotekhnika, Mashinostroenie, Moscow, 1980. [4] H.J. Besch, Nucl. Instr. and Meth. A 360 (1995) 277. [5] E.A. Babichev et al., Nucl. Instr. and Meth. A 419 (1998) 290. [6] EG&G Reticon, MB Series, Ampli"er}Multiplexer array chips, 055-0343, January 1997. [7] F. Sauli, Nucl. Instr. and Meth. A 386 (1997) 531. [8] A. Bondar et al., Nucl. Instr. and Meth. A 419 (1998) 418. MEDICINE/BIOLOGY