CABLE ACCESSORIES kv

Similar documents
CABLE ACCESSORIES kv

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

EDITION 2012 CABLE SYSTEMS

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

a Nexans company Catalogue 2014

08. SEK IDC CONNECTORS

ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

Premolded cable termination, indoors SOT 7.2 kv

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

Transformer Bushings for GIS

UGVCL/SP/591/11KV HT AB CABLE

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

SECTION DRY-TYPE TRANSFORMERS

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

Medium voltage insulator

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

a Nexans company Catalogue 2013

Analytical Report RF high voltage cable accessories market

Transmission Silicone Insulators Line Post 69 kv to 161 kv

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

OLI. Oil level indicator

1 FOSC cover 1 piece Protecting fiber cable splices in whole 2 FOSC bottom 1 piece Fixing reinforced core, fiber cable

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

Terminal Boxes Series 8146

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

A Study of a MV Cable Joint

Series 8146/5-V37 and Series 8150/5-V37

Wall Mounted Products

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

No Heat. No Flames. No Shoving. No Special Tools. 3M Cold Shrink. 3M Cold Shrink. Medium Voltage Joints & Terminations. 3M Cold Shrink Joint

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.:

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Development of 22-kV XLPE Cable and Joint with Reduced Insulation Thickness Having Water-Impervious Aluminum Layer

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

KNOW YOUR OPTIONS: 230 KV POWER CABLES

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Unified requirements for systems with voltages above 1 kv up to 15 kv

High Voltage Systems. Today. The history of cables

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Section kv Power Cables

INTERNATIONAL STANDARD

How To Read A Pipe From A Sensor

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

Linear Luminaire with LED Series EXLUX 6402/2

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

DS 600. A contact free flux gate based current measurement sensor 600A rms

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

HERZ-Thermal Actuators

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

BETAtrans. Cables and Systems for Rolling Stock. Edition 2006

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Cable Plug acc. to DIN EN , Form A

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

THE PATHWAY TO POWER HIGH-VOLTAGE CABLES

ADM1TE 5/30A DIN rail single phase two wire energy meter

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

High Voltage Cable Systems

Portable digital microprocessor thermometers with interchangeable probes

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

ACCESSORIES FOR XLPE-INSULATED HIGH AND EXTRA-HIGH VOLTAGE CABLES

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Gulf Cable & Electrical Ind. Co.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Type K current limiting fuse canister Technical information and installation guide

VIPERFLEX ELECTRIC CABLE

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Catalog. Arc Guard System TM TVOC-2

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Voltage Regulator SPAU 341 C. Product Guide

6-36kV Medium Voltage Underground Power Cables. XLPE insulated cables

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

LED High Bay Light 100W

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Vario-Series Accessories

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

XLPE Land Cable Systems User s Guide. Rev 5

F05D Meeting on Damped AC Voltage Testing

ENERGY /// HIGH VOLTAGE CABLE ACCESSORIES UP TO 245 KV RAYCHEM HIGH VOLTAGE CABLE ACCESSORIES UP TO 245 KV

TELESCOPE Motorized Lighting Suspension

SD Memory Card Connectors

Medium Voltage Joints & Terminations

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

HV Submarine Cable Systems Design, Testing and Installation

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Fault location on power cables. Fault location on power cables

Important Information: Complete Terms and Conditions are printed on sales invoices

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

Product and functional description

Transcription:

CABLE ACCESSORIES 110-220 kv

Introduction Long terms of cable accessories delivery very often are a big problem for cable lines establishing. That is why there is a great demand of cable accessories for HV cables in the market, with high quality and minimum terms of delivery for the reasonable price. Arkasil SK LLC sets the goal to hold a strong position in the cable business. The main activity of Arkasil is HV accessories 110-220 kv production and delivery, and also related products such as tools, heat shrinkable components, HV connectors and other products for cable line construction. History Arkasil SK LLC was established in 2010. Owing to the unique skills and knowledge of cable business the company could develop cable accessories 110-220 kv design for a short period of time. The equipment was chosen and the necessary material and components were purchased for the insulating parts production. In 2010 Arkasil SK LLC obtained the production facility in Moscow region, it was renovated and reconstructed to organize the cable accessories 110 kv production. Successful Type Tests At the beginning of 2011 the type tests of the cable accessories 110 kv in accordance to IEC 60840-2004 were successfully carried out together with CESI (market leader among the leading international organizations providing measurements and inspection, testing & certification). In autumn 2011, the type tests of Arkasil SK terminations and joints for 110 kv were completed. The tests were performed in the KEMA (the Netherlands) laboratory under the Harmonized European Standard HD 632 S2, part 1, analogue of the IEC 60840, rev. 3 (2004). The company have start long-term tests of the cable system 220 kv together with 220 kv Arkasil cable accessories till the end of 2012.

Outdoor termination 110 kv Technical description Outdoor termination MKB 126 / 145 with silicone type insulator uses for the connection of cable line with other elements of power supply systems. Outdoor termination MKВ 126 /145 uses for outdoor and indoor installation, for XLPE cables 64/110 kv with the conductor cross-section up to 2000 mm2. Basic components Insulator silicone type insulator with glass fiber reinforced epoxy resin tube and silicone rubber sheds sheds color light gray top and bottom flanges glued and sealed to the silicone insulator Cable end pre-moulded and factory-tested silicone stress cone cable end base plate branch pipe with flange support insulators seals and fixing materials polybytene insulation oil optical fiber splice box for the connection to the equipment Application Type MKВ 126 / MKB 145 Highest voltage for equipment (Um), kv 126 / 145 Cable conductor cross section range, mm2 185 2000 Maximum cable diameter, mm 115 Maximum cable insulation diameter, mm 94 Demands to the electrical parameters: AC voltage withstand test: Partial discharge test: Impulse voltage (10+/10- impulses) Operating temperature range: 160 kv for 30 min / 190 kv for 30 min 5 pc at 96 kv / 5 pc at 114 kv 550 kv / 650 kv -60 С/ +50 С Nominal operating current: limited by cable specification 2

Description Highest voltage for equipment (Um) Maximum cable insulation diameter Maximum cable diameter Cable conductor cross -section range Maximum allowed inclination, angle Length (approx.) Creepage distance length Pollution level in accordance with (IEC 60137) Volume of insulation oil (approx.) Weight (approx.) Maximum allowed force on top connector kv mm mm mm 2 mm mm l kg kn MKB126 / 145 126 / 145 94 115 185-2000 45 1540 1863 1875 3670 4300 5000 3/3 4/3 4/4 28 32 38 104 108 113 3,5 3,5 3,5 Stress cone routine tests for MKB 126 / MKB 145 Test voltage level: 160 kv for 30 min / 190 kv for 30 min Partial discharges level: <5pC at 96 kv / <5pC at 114 kv Support insulator withstand voltages: AC voltage: 10 kv DC voltage: 20 kv Mechanical characteristics: Maximum allowed inclination with vertical: 45 C Approximate weight, kg: 115 Maximum allowed force on top connector, H (horizontal): 3500

Cable clamps To fix the cable near the outdoor termination and joints, BKK cable clamps with the rubber inserts (PST-80) is used. Cable clamps together with rubber inserts exclude the cable longitudinal movement. Type BBK L l h d 65/90 175 140 50 13 85/105 185 150 64 13 100/125 204 170 67 13 Flat connectors To connect terminations to the networks, flat connectors should be used. Arkasil SK supplies aluminum, bronze and bimetallic flat connectors. Splice box It is applied for connection of fiber-optical modules. Splice box is a protective metal box, safety class IP66, with 4 inputs for fiber-optical modules, 2,5-5,5 mm in diameter. It protects the connection point and is applied to store the fiber stock necessary for repair or preventive works.

Joints 110 kv Technical description Pre-moulded outdoor joint MСВ 126 / 145 is designed to connect two XLPE 64/110 kv high voltage cables. Joint MСВ 126 / 145 could be produced in different constructions which give the possibility of screen wires direct connection, cross-bonding connection of different cable phase wires screen (screen transition), wires screen connection with optical fibers in the metal tubes (modules). Basic components Joint body Silicone pre-moulded joint body with conductive elements for electrical field control Connector and sealing materials One piece pre-moulded silicone joint body Special tapes for different purposes Protective covering from heat shrinkable tubes and sleeves (optionally it other protective covering) Application Type МСВ 126 / 145 Highest voltage for equipment (Um),kV 126 / 145 Cable conductor cross- section range, mm² 185 2000 Maximum cable diameter, mm 115 Maximum cable insulation diameter, mm 91 Technical data Demands to the electrical parameters: AC voltage withstand test: 160 kv for 30 min. / 190 kv for 30 min. Partial discharge test: <5 pc at 96 kv / <5 pc at 114 kv Impulse voltage (10+/10- impulses) 650 kv Operating temperature range: -60 С/+50 С Currency load rating: Rated operational current: Short circuit current: limited by cable specification limited by cable specification 5

Joint body routine tests: Test voltage level: Partial discharges level: 160 kv for 30 min / 190 kv for 30 min <5pC at 96 kv / <5 pc at 114 kv Mechanical characteristics: Approximate weight, kg: 35 Joints overall dimensions MСВ 126 / 145 Joints overall dimensions МСВ 126X / 145X Additionary Joint Splice box It is applied for connection of fiber-optical modules which is used for temperature monitoring of high voltage cables. A joint splice box is a protective rubber base with slots and channels for the optical fibers, it provides connection of the modules, protects the connection point. It is fixed during the joint installation. The supply complete set includes all necessary accessories for the optical modules welding. 6

Installation and Supervision service Arkasil SK LLC renders services on installation and supervision of own high voltage cable accessories. Installation supervision services for cable accessories: basic and technical control quality control of trained stuff in Arkasil SK to installed cable accessories and who have special certificates. guarantee documentation on the installed Arkasil SK cable accessories Arkasil SK cable accessories related consultations "Installation Supervision" in the construction standards is not defined yet. Therefore, when making an agreement, it is necessary to be governed by the normative documents, including The Regulations For Installation/ Supervision, governing the bases for granting consulting services and the contractual relations, in general. For more information on the installation and supervision provided by Arkasil SK, please call: +7 (495) 669-39-49 Installation Training Arkasil SK LLC arranges training for the installation contractor specialists. The training is arranged at Arkasil SK training center. There, for optimization of the educational process, Arkasil SK renders the training service at the installation contractor production facilities. The training shall include: Theory training Practical training Tests Sample preparation for certification Granting certificates By the results of examinations, the installation contractor specialists are receiving the permission for Arkasil SK cable accessories installation.