Polymer Braced Post Insulators

Similar documents
Transmission Silicone Insulators Line Post 69 kv to 161 kv

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

Design Test Report Veri*Lite Suspension Insulators Catalog Numbers: , , ,

V.A PJM Design and Application of Overhead Transmission Lines 69kV and Above

INSTALLATION. General. Important Note. Design. Transport

Rear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003

Pole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E.

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

EFFECTS OF CORONA RING DESIGN ON ELECTRIC FIELD INTENSITY AND POTENTIAL DISTRIBUTION ALONG AN INSULATOR STRING

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Mounting Instructions. Torque Transducer. A en

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

INTRODUCTION TO BEAMS

Hi*Lite XL Transmission Insulators

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

CHATILLON DG Series Mechanical Force Gauge. Operating Instructions

CLEAR-DIVISIONS CENTERFOLD

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

LCWM Glossary. Mettler Toledo LCWM Glossary

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

OLI. Oil level indicator

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Manufacturing. Detailing. Transmission Structures. Quality. Reliability. Timely Delivery. Design. Prototyping. Testing. Supply. Towers.

Truss. are both simple and A Matsuo Example continuous trusses. The

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

Optimum proportions for the design of suspension bridge

FXA UNIT G484 Module Simple Harmonic Oscillations 11. frequency of the applied = natural frequency of the

Nordson Automatic Spray Gun Support Kits

V47 Series Temperature Actuated Modulating Water Valves

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Transformable Billboard

PRODUCT SPECIFICATION

Length measuring instruments

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

Seismic Analysis and Design of Steel Liquid Storage Tanks

Weatherproof Tournament Table Tennis Table

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

KS-70. Catheterization Table GENERAL

AMF112 Instruction Manual

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Boom and fly capacities for this machine are listed by the following sections:

CLEAR-DIVISIONS VARIOFOLD

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Medium voltage insulator

The Collapse of Building 7 by Arthur Scheuerman December 8, 06

PART 1 GENERAL 1.1 SECTION INCLUDES

4.4 WAVE CHARACTERISTICS 4.5 WAVE PROPERTIES HW/Study Packet

Current Transformers

SMA Interface Mating Dimensions (Per MIL-STD-348)

Evaluation Report CCMC R Pieux Vissés Vistech / Postech Screw Piles

Milling and Machining Center Basics

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

PowerLine Magnetic-Laser Sheave Alignment System Instructions

9300BC SERIES Light Commercial Door Closer

uline.com SPECIFICATIONS

Advantages of Fixed Circuit Breaker Switchgear

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

High Strain Dynamic Load Testing of Drilled Shafts

Toroidal Conductivity Sensor

TubeTrace, ThermoTube

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

AMF112 ( <00>) 13mm (1/2 in.)

bi directional loading). Prototype ten story

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Chapter 3 Pre-Installation, Foundations and Piers

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LD Physics Leaflets P

Shaft- Mounted Speed Reducers

POST AND FRAME STRUCTURES (Pole Barns)

SECTION WINDOW WASHING SYSTEMS

SEISMIC EVALUATION OF HOSPITAL PIPING SYSTEMS

CASE HISTORY #2. APPLICATION: Piping Movement Survey using Permalign Laser Measurement System

The Bonelle Tool and Cutter Grinder

ElectroMagnetic Induction. AP Physics B

Centripetal Force. This result is independent of the size of r. A full circle has 2π rad, and 360 deg = 2π rad.

Impact testing ACTIVITY BRIEF

EVALUATION OF DUAL CABLE SIGNAL SUPPORT SYSTEMS

DELRIN HYTREL MINLON RYNITE

A Practical Guide to Dielectric Testing

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

HYDRAULIC LIFT TABLE CART 2200-LB.

GUIDELINE FOR HAND HELD SHEAR VANE TEST

Settlement of Precast Culverts Under High Fills; The Influence of Construction Sequence and Structural Effects of Longitudinal Strains

MONDOATHENS BASKETBALL SET (Reference PK110)

Transcription:

CATALOG 145 Polymer Braced Post Insulators NGK-Locke Polymer Insulators, Inc. Virginia Beach, Virginia, U.S.A.

TABLE of CONTENTS Braced Line Post (BLP) Assemblies................ 2 Load Definitions............................... 3 Types of BLP Assemblies........................ 4 Braced Line Post (BLP) Assembly Swivel Horizontal V (SHV) Assembly Application Guideline for SHV insulators............. 5 BLP Insulator Catalog........................... 6 Braced Line Post using 2.5" LP................... 7 Braced Line Post using 3.0" LP................... 8 Swivel Horizontal Vee with 2.5" LP................. 9 Customer Design Form......................... 10 Research & Development....................... 11 Notes...................................... 12 NGK-Locke Polymer Insulators, Inc. management systems comply with the requirements of ISO 9001:2008 (Certificate #FM36580, since 1997) and ISO 14001:2004 (Certificate #EMS96014, since 2005); the registrar for both certificates is BSI Group America Inc., based in Reston, Virginia. 1

BRACED LINE POST (BLP) ASSEMBLIES A Braced Line Post assembly consists of a stay (sometimes called a brace or suspension) insulator, a strut (a post) insulator and hardware that connects them to each other and to a supporting structure. The assembly forms a V shape away from the supporting structure, so it is often called a Horizontal Vee. More correctly, it should be called a braced post assembly, because the strut (post insulator) is not often horizontal. BLP assemblies simultaneously achieve dimensional compactness and the high strength desired for transmission lines. Their compact form is derived from a standard line post (LP) which forms the strut component and allows for a narrow right-of-way. A high vertical load capacity is achieved with the addition of a stay. BLP construction is one solution to the growing demands of a modern society for transmission line designs that consider both the environment and the budget. Fig.1 shows the relationship between the vertical loading capacities of LP (1.75 ~ 3.5 FRP core) and BLP (braced line post with a 2.5 FRP core) constructed of polymer insulators. The curves show the Maximum Design Load (MDL) level. As the chart indicates, the loading capacity of the BLP far exceeds that of the LP s. Fig. 1 Load comparison chart Large 2.5" BLP 10000 Vertical Loading Capacity 8000 6000 4000 3.5" LP 3.0" LP 2.5" LP 2000 1.75" LP Small 0 0 20 40 60 80 100 120 140 Short Insulator Length Long 2

LOAD DEFINITIONS The loads that can be applied to the BLP assembly at the conductor attachment point are defined as follows: 1) Vertical load is the load perpendicular to the ground. The weight of a conductor and connecting hardware, for example, create a vertical load. 2) Longitudinal load is a load along the conductor that the BLP supports. It is generated by forces that are unbalanced from one side of the insulator to the other. Factors causing imbalance include: different conductor lengths (spans), changes in altitude, changes in conductor angle, wind and/or icing, and a broken conductor. 3) Transverse load is a load along the post that is generated either toward or away from the supporting structure. Transverse loading toward the structure is Compression and loading away from the structure is Tension. Factors that can affect this type of loading include post angle and wind strength. Fig. 2 Load directions 3

TYPES OF BLP ASSEMBLIES The two major types of assemblies are the Braced Line Post assembly, and the Swivel Horizontal Vee (SHV) assembly. Braced Line Post (BLP) Assembly: A BLP is a line post insulator that is braced with a suspension insulator (Fig. 3). BLP design takes into account the different types of loading, but its greatest advantage is that vertical load capacity is improved by the brace. While longitudinal load capacity can be improved, it generally depends on the strength of the line post alone. Fig. 3 Braced Line Post (BLP) Swivel Horizontal Vee (SHV) Assembly: A SHV is a braced post insulator which has a swivel base connecting it to the supporting structure (Fig. 4). The advantage of the SHV is that it resists longitudinal loads by swinging in the direction of the load. However, care must be exercised in designing SHV. Please see application guideline for SHV insulators on the next page. Fig. 4 Swivel Horizontal Vee (SHV) 4

APPLICATION GUIDELINE FOR SHV INSULATORS Under extreme environmental conditions such as hurricanes or blizzards, SHV assemblies can experience unexpected transverse loads from high winds or icing. These loads are cumulative and are amplified over the length of the system, which can lead to cascading collapse. But under normal service conditions, a welldesigned system using SHV assemblies will support typical transverse loading. General guidelines or "rules of thumb" for successful SHV application are shown below: A) The hinge angle should be greater than 20 in order to increase longitudinal stability (refer to Fig. 4). B) The number of SHV assemblies in sequence should be fewer than eight, depending upon span length and anticipated wind loading, because insulator displacement (swing) is cumulative (see Fig. 5). C) Span lengths should be less than 700 feet (213 m), depending upon hinge angle and number of consecutive assemblies. E) SHVs should not be used where they can experience uplift, such as where there are different elevations between the supporting structures, or where there is a possibility of conductor gallop. It s recommended that the user analyze all SHV applications. This type of assembly should be used with caution where the guidelines must be exceeded. The analysis will show whether the proposed installation is safe. Although unlikely, conditions may also arise that cause the insulator to collapse (e.g., excessive rotational deflection), even if the installation falls within the guidelines. The purchaser must carefully determine potential excessive longitudinal behavior when designing this type of system. During construction, the preferred method of conductor stringing involves temporarily mounting the stringing sheave directly to the supporting structure. If the sheave is mounted directly to the SHV assembly, it is recommended that the SHV be temporarily anchored with ropes to keep the assembly from longitudinal movement. D) Compressive horizontal line (deflection) angles should be less than 2. Fig. 5 Illustration of cumulative displacement of insulators 5

BLP INSULATOR CATALOG Standard BLP assembly designs appear on the following pages. They may be ordered as complete sets, including all illustrated hardware, by referencing the catalog number. Upon request, combined load curves can be supplied for all BLP assemblies. All items carry the NGK-Locke standard warranty. In addition to the items in this catalog, custom BLP assemblies can be designed to customer specifications. Please use the worksheet at the end of this section to specify your needs. 6

2.5" (63mm) CORE BRACED LINE POST (BLP) ASSEMBLY System Voltage, Catalog No. Component Catalog No. 1) Arcing Distance, Leakage Distance, 2) A Dimension B C Low Frequency Flashover Dry Wet Critical Impulse Flashover Pos. Neg. Vertical Design Loads, lbs. 3),4) Tension Compression Longitudinal 115 HV-554 L2-SN321-13 251-SC480-EE 46.5 (1181) 132.3 (3360) 58.2 (1478) 69.8 (1772) 64.1 (1628) 495 435 730 800 10000 7500 7500 1530 138 HV-556 L2-SN361-13 251-SC550-EE 52.4 (1331) 148.8 (3780) 64.0 (1625) 78.0 (1982) 71.3 (1810) 545 475 820 890 10000 7500 7500 1375 161 HV-558 L2-SN431-13 251-SC670-EE-04 62.0 (1575) 177.8 (4515) 74.1 (1881) 92.2 (2343) 83.4 (2118) 620 545 960 1040 10000 7500 7500 1165 230 HV-560 L2-SN581-13 251-SC920-EE-08 81.8 (2078) 239.8 (6090) 95.7 (2432) 121.8 (3093) 108.1 (2745) 765 670 1255 1350 8450 7500 7500 880 1) Refer to individual product catalogs for details of the components. 2) The leakage distance is the lesser value of the strut and stay. 3) Design loads are for single loads in the specified direction. 4) Design load values do not consider the supporting structure strength. The catalog numbers listed above use a bendable curved base. A flat base option is also available upon request. Application of corona ring(s) depends on requirements. For more detailed information please contact our local sales representative. 7

3.0" (76mm) CORE BRACED LINE POST (BLP) ASSEMBLY System Voltage, Catalog No. Component Catalog No. 1) Arcing Distance, Leakage Distance, 2) A Dimension B C Low Frequency Flashover Dry Wet Critical Impulse Flashover Pos. Neg. Vertical Design Loads, lbs. 3),4) Tension Compression Longitudinal 115 HV-562 L3-SN321-13 251-SC470-EE 47.3 (1202) 131.4 (3337) 59.2 (1504) 68.6 (1742) 67.3 (1710) 500 440 745 815 11000 7500 7500 2400 138 HV-564 L3-SN361-13 251-SC530-EE 53.1 (1350) 148.1 (3763) 64.8 (1647) 75.7 (1922) 73.4 (1864) 550 480 830 905 11000 7500 7500 2160 161 HV-566 L3-SN421-13 251-SC630-EE-04 61.3 (1557) 176.1 (4473) 73.3 (1862) 87.5 (2222) 84.3 (2140) 615 540 950 1030 11000 7500 7500 1880 230 HV-568 L3-SN581-13 251-SC880-EE-08 82.5 (2096) 246.0 (6248) 95.9 (2436) 117.1 (2973) 110.2 (2800) 770 675 1265 1360 11000 7500 7500 1395 1) Refer to individual product catalogs for details of the components. 2) The leakage distance is the lesser value of the strut and stay. 3) Design loads are for single loads in the specified direction. 4) Design load values do not consider the supporting structure strength. The catalog numbers listed above use a bendable curved base. A flat base option is also available upon request. Application of corona ring(s) depends on requirements. For more detailed information please contact our local sales representative. 8

2.5" (63mm) CORE SWIVEL HORIZONTAL V (SHV) ASSEMBLY System Voltage, Catalog No. Component Catalog No. 1) Arcing Distance, Leakage Distance, 2) A B Dimension C D E Deg. Approx. Low Frequency Flashover Dry Wet Critical Impulse Flashover Pos. Neg. Design Loads, lbs. 3),4) Vertical Tension Compression 115 HV-570 L2-SN321-1S*1 251-SS370-EE 47.0 (1195) 125.5 (3188) 59.8 (1518) 56.8 (1442) 56.6 (1437) 22.8 (580) 59 485 430 740 800 10000 7500 7500 138 HV-571 L2-SN361-1S*1 251-SS420-EE 52.8 (1341) 141.8 (3602) 65.6 (1667) 62.7 (1592) 61.3 (1557) 24.5 (622) 58 540 480 825 890 10000 7500 7500 161 HV-572 L2-SN431-1S*1 251-SS510-EE-04 62.3 (1582) 172.8 (4388) 75.9 (1928) 73.3 (1862) 70.2 (1783) 27.7 (704) 58 625 545 965 1045 10000 7500 7500 230 HV-573 L2-SN581-1S*1 251-SS710-EE-08 82.0 (2083) 239.8 (6090) 98.0 (2489) 97.0 (2463) 90.7 (2304) 35.2 (894) 57 765 670 1260 1355 10000 7500 7500 1) Refer to individual product catalogs for details of the components. 2) The leakage distance is the lesser value of the strut and stay. 3) Design loads are for single loads in the specified direction. 4) Design load values do not consider the supporting structure strength. Other base options are available upon request. Application of corona ring(s) depends on requirements. For more detailed information please contact your local sales representative. 9

CUSTOM BRACED POST REQUEST FORM In order for us to design the correct assembly for your application, please fill out as much of this form as possible. Items shown in yellow are the most critical requirements. NGK-LOCKE Polymer Insulators, Inc. Date Inquiry Number System Voltage () Country Company Name Quantity Contact information Insulator Side Line Earth Line Earth Corona Ring Application Insulator Type Yes No s t r 10 For swivel HV design please contact your local sales representative

RESEARCH & DEVELOPMENT Calculating the mechanical and electrical performance of BLP assemblies is more complicated than for individual line post or suspension insulators because BLPs consist of a combination of insulators and hardware that have individual characteristics. Full-scale testing is extremely important to verify the assembly designs. Testing of the designs has been conducted at the NGK High Voltage Laboratory in Japan, one of the world s largest and most advanced private-sector laboratories. Mechanical Tests: Insulators with various core diameters and lengths were subjected to single and combined load tests. See Fig. 6 & 7. (Bare rods are often used during the tests to attach strain gauges directly to the rods for monitoring and data collection purposes.) Electrical Tests: Complete BLP assemblies are subjected to various electrical tests, as shown in Fig. 8 & 9. The electrical characteristics of assemblies are dependent on the combination of the stay and strut, the angle between the two, and the resultant air gap. Fig. 6 - One axis testing (transverse compression load) Fig. 7 Load testing on three axes Fig. 8 Dry flashover test Fig. 9 Impulse flashover test 11

NOTES: NGK-Locke Polymer Insulators, Inc. 12

1609 Diamond Springs Road, Virginia Beach, Virginia 23455, U.S.A. Tel: +1(757) 460-3649 Fax: +1(757) 460-3550 Website: www.ngk-polymer.com Email: info@ngk-polymer.com NGK INSULATORS, LTD. U.S.A. NGK-Locke, Inc. Atlanta Office 1880 West Oak Parkway, Suite 104 Marietta, Georgia 30062, U.S.A. Tel: +1(404) 659-3153 Fax: +1(404) 524-6185 Baltimore Office 2525 Insulator Drive Baltimore, Maryland 21230, U.S.A. Tel: +1(410) 347-1700 Fax: +1(410) 347-1724 Los Angeles Office 21250 Hawthorne Blvd., Suite 500 Torrance, California 90503, U.S.A. Tel: +1(310) 316-3323 Fax: +1(310) 316-3944 Canada NGK Insulators Canada, Ltd. Toronto Office 2700 Matheson Blvd. East, Suite 700 East Tower, Mississauga L4W 4V9, Ontario, Canada Tel: +1(905) 602-1266 Fax: +1(905) 238-8247 Montreal Office 1501, Avenue McGill College Bureau 515 Montreal (Quebec) H3A 3M8, Canada Tel: +1(514) 281-8488 Fax: +1(514) 281-8596 All Other Countries NGK Insulators, LTD Add: 2-56, Suda-cho, Mizuho, Nagoya, 467-8530, Japan Tel: +81-52-875-7511 Fax: +81-52-872-7530 Web: http://www.ngk.co.jp/english/index.html pr-office@ngk.co.jp