Imaging for Proton Treatment Setup and Verification

Similar documents
HITACHI Proton Beam Therapy System

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

Gated Radiotherapy for Lung Cancer

FOR IMMEDIATE RELEASE

IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

Scripps Proton Therapy Center: Configuration and Implementation

Radiation Protection in Radiotherapy

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

Daily IGRT with CT-on-Rails Can Safely Reduce Planning Margin for Prostate Cancer: Implication for SBRT

ADROTERAPIA A MEDAUSTRON

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

Proton Therapy for Prostate Cancer

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

RADIOTHERAPY Giovanna Mantello

REPORT ORGANIZATION ABSTRACT I. INTRODUCTION CALCULATION OF EFFECTIVE DOSE PER IMAGE ACQUISITION CALCULATION OF EFFECTIVE DOSE PER TREATMENT COURSE

Chapter 7: Clinical Treatment Planning in External Photon Beam Radiotherapy

Use of 3D Printers in Proton Therapy

What is the CyberKnife System?

Design and Scheduling of Proton Therapy Treatment Centers

02 CyberKnife: Treatment Delivery

IBA Proton Therapy. Biomed days Vincent Bossier. System Architect Protect, Enhance and Save Lives

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients

First Three Years After Project Proton Therapy Facility:

Total Solutions. Best NOMOS One Best Drive, Pittsburgh, PA USA phone NOMOS

Acknowledgements. PMH, Toronto David Jaffray Doug Moseley Jeffrey Siewerdsen. Beaumont Hospital Di Yan Alvaro Martinez. Elekta Synergy Research Group

Current Status and Future Direction of Proton Beam Therapy

Overview of Proton Beam Cancer Therapy with Basic Economic Considerations

Post Treatment Log File Based QA Varian. Krishni Wijesooriya, PhD University of Virginia. D e p a r t m e n t of R a d i a t i o n O n c o l o g y

Gamma Knife and Axesse Radiosurgery

CBCT for Prone Breast. Todd Jenkins, MS, DABR Nash Cancer Treatment Center

Radiation Therapy. 1. Introduction. 2. Documentation of Compliance. 3. Didactic Competency Requirements. 4. Clinical Competency Requirements

Fundamentals of Cone-Beam CT Imaging

Proton therapy, yesterday, today and tomorrow

Quality Assurance of Radiotherapy Equipment

Quality Assurance in Stereotactic. Radiotherapy

World-first Proton Pencil Beam Scanning System with FDA Clearance

Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179

CTVision System. Accurate Imaging for Precise Treatment.

In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers

Deformable Registration for Image-Guided Radiation Therapy

PROTON THERAPY MADE EASY

Quality Assurance of accelerators; the technologists responsibility

Precise Treatment System Clinically Flexible Digital Linear Accelerator. Personalized radiotherapy solutions for everyday treatment care

Proton Therapy. What is proton therapy and how is it used?

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.

Innovative RT SBRT. The variables with REQ in superscript are required.

HDR Brachytherapy 1: Overview of QA. Disclosures: Learning Objectives 7/23/2014

Radiation Therapy Coverage, Coding, and Reimbursement for New Technologies

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

1. Provide clinical training in radiation oncology physics within a structured clinical environment.

Key words: treatment planning, quality assurance, 3D treatment planning

Evolution of Head and Neck Treatment Using Protons. Mayank Amin, M.Sc,CMD

Clinical Rotation 3: PHYS 705 Fall 2015 (Aug. 25, 2015 to Feb. 25, 2016) COURSE INFORMATION

Radiosurgery 8/16/2011. Intracranial Stereotactic Radiosurgery (SRS) and Stereotactic Radiotherapy (SRT) Kamil M. Yenice, PhD University of Chicago

Chapter 7 CLINICAL TREATMENT PLANNING IN EXTERNAL PHOTON BEAM RADIOTHERAPY

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Proton Therapy for Head & Neck Cancers

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

CHAPTER 7. CLINICAL TREATMENT PLANNING IN EXTERNAL PHOTON BEAM RADIOTHERAPY

2015 ASTRO INVESTOR MEETING. October 20, 2015

A Patient s Guide to the Calypso System for Breast Cancer Treatment

PROTON THERAPY MADE EASY

Data. microcat +SPECT

Tumor. An Brief Introduction to 4D CT Scanning. Outline. Three Types of Motion Artifacts. CT Artifacts in Free Breathing 3D Scan

Proton Therapy Essentials

Proton Therapy - Frequently Asked Questions For Clinicians

Our Facility. Advanced clinical center with the newest and highly exact technology for treatment of patients with cancer pencil beam

Interactive X-Ray and Proton Therapy Training and Simulation

How To Improve Your Ct Image Quality

INTENSITY MODULATED RADIATION THERAPY (IMRT) FOR PROSTATE CANCER PATIENTS

Our Department: structure and organization

Acknowledgement. Prerequisites: Basic Concepts of IMRT. Overview. Therapy Continuing Education Course Clinical Implementation of IMRT for Lung Cancers

Performance evaluation and quality assurance of Varian enhanced dynamic wedges

THE DOSIMETRIC EFFECTS OF

Failure Modes and Effects Analysis (FMEA)

Physics and Dosimetry of SBRT: Simulation and Localization. Moyed Miften, PhD University of Colorado

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Radiation Therapy in Prostate Cancer Current Status and New Advances

Automotive Applications of 3D Laser Scanning Introduction

Proton beam. Medical Technical Complex Joint Institute for Nuclear Research, Dubna, Russia

The Essential Role of CT Planning and TEE Guidance to Optimize Device Deployment

Clinical Education A comprehensive and specific training program. carry out effective treatments from day one

Protons vs. CyberKnife. Protons vs. CyberKnife. Page 1 UC SF. What are. Alexander R. Gottschalk, M.D., Ph.D.

Stereotactic Radiotherapy for Prostate Cancer using CyberKnife

Corporate Medical Policy


Quality Reports With. PlanIQ. *Export only. 510(k) pending. Patent pending. Your Most Valuable QA and Dosimetry Tools

Transcription:

Imaging for Proton Treatment Setup and Verification Jon J. Kruse Mayo Clinic Dept. of Radiation Oncology Rochester, MN

Acknowledgements T.J. Whitaker; Mayo Clinic Hiroki Shirato, Kikuo Umegaki; Hokkaido University Mark Pankuch; ProCure Alessandra Bolsi, Tony Lomax; PSI Sung Park; McLaren Jonathon Farr; St. Jude Lei Dong; Scripps

Proton vs Photon IGRT In the past 15 years IGRT for x-ray therapy has evolved and matured EPID kv Radiographic systems CBCT MR Linacs Proton therapy IGRT has lagged behind Market size Different needs, priorities in proton therapy

Photon IGRT Systems What is the purpose of the system? Pre-treatment setup imaging Intra-fractional monitoring Feed adaptive planning protocols Targeting strategy Bony anatomy Fiducials Soft tissue visualization

Proton IGRT Considerations Delivery system constraints Gantry geometry Treatment modality Efficiency Proton treatment rooms are expensive Precise setup critical protons more sensitive to changes in volume, pose Targeting goals Anatomy targeting for protons different than for photons

Photons: Radiographic Localization Suitable for when bony anatomy is a good surrogate for target tissue, or when fiducials are placed Gantry mounted MV EPID kv Systems Fixed position imagers BrainLab ExacTrac Hokkaido fluroscopic system

Gantry Mounted Imagers

Photon Gantry Mounted Imagers Use of treatment beam for imaging Imaging during treatment BEV imaging Important Sanity Check on patient setup, other IGRT procedures Rotating gantry facilitates CBCT

BEV Imaging in Protons Small spot size important for scanning proton facilities X-ray tube in a scanning nozzle introduces atmospheric drift length; larger spot size Can t image during proton treatment Gillin et al., Med Phys 37 (2010) p. 154

Gated Spot Scanning Proton Beam Therapy System with Real-time Tumor-tracking (RT) Technology Real-time Tumor-tracking Radiation Therapy Developed by Hokkaido University Spot scanning Proton Beam Therapy Integration Developed by Hitachi, Ltd. New PBT System

Cone-beam Computed Tomography, Real-time tumormonitoring, and gated proton spot-scanning beam therapy. Proton beam scanning nozzle Flat panel detectors & X-ray tubes X-ray fluoroscope Proton beam Robotic couch Hokkaido University ; Supported by a grant from the Japan Society for the Promotion of Science (JSPS) through the Funding for World-Leading Innovative R&D on Science and Technology (FIRST program).

High precision positioning system (2D, 3D, and 4D) 2D, 3D positioning based on bony anatomy and soft tissue matching (radiography, CBCT) 4D positioning (real-time tumor-monitoring system) Verification fiducial migration (radiography, CBCT) inter-fractional variation of proton range (CBCT) Gold marker 3 + 1 dimensional positioning (real-time tumor-monitoring system, Hokkaido University)

Limited Gantry Proton Systems Proton gantries are large and expensive Limited number of beam angles gives adequate plan quality for a number of treatment sites Lose the gantry support structure for imaging equipment

ProCure Fixed Beam Imaging Image from ProCure Website

Mayo Clinic Half Gantry Fast Intra-Tx imaging at any gantry/couch position Fluoroscopy capable Large FOV No moving parts stable imaging isocenter 6 DOF matching software

Mayo Clinic Half Gantry Limited to two imaging angles FOV is 30 cm x 30 cm at isocenter may not see center of tumor volume for non-isocentric plans

ProTom Robotic C-Arm Rotates to acquire radiographic projections for setup on 2D images Robotic arm allows for mobile imaging isocenter CBCT capable Courtesy of Sung Park

ProTom Robotic C-Arm Imager Retracts to avoid interference with therapy nozzle, rotating couch Courtesy of Sung Park

St. Jude Hitachi Robotic C-Arm Retractable C-Arm for radiographic/cbct localization St. Jude IGRT protocols rely heavily on CBCT Emphasis on imaging dose reduction Courtesy of Jonathon Farr

Mayo Clinic Half Gantry Limited to two imaging angles FOV is 30 cm x 30 cm at isocenter may not see center of tumor volume for non-isocentric plans Not CBCT capable

Utility of CBCT for Protons Bony anatomy is often a poor surrogate for target/critical anatomy Fiducials or CT localization required in cases where we expect movement of soft tissues relative to radiographically evident bony anatomy Photons: Place target tissue at isocenter, don t worry about upstream bony anatomy Protons:??

CT Localization for Protons: Pelvis Change in position of bony anatomy alters dose distribution CT localization may be of limited use

CT localization of lung tumors desirable for proton therapy CT Localization for Protons: Lung Change in position of rib causes minimal disturbance of dose distribution

CBCT for Lung? Mayo proton facilities will be scanning beam only Treatments of mobile tumors will probably require gating/breath hold Free-Breathing CBCT imaging a poor reference for gated/breath held treatment Gated/breath held CBCT not impossible, but not easy

CBCT for Adaptive Protocols Proton dose calculation is extremely sensitive to CT number accuracy CT number accuracy / consistency not generally a priority in CBCT Increased scatter relative to helical CT degrades imaging performance

Helical/CBCT Phantom Images CBCT Helical CT Images Courtesy of T.J. Whitaker

CT on Rails

CT on Rails Robot moves patient to imaging isocenter CT translates over patient for imaging Robot moves patient back to treatment isocenter while CT registration is performed Helical CT image quality Images for adaptive imaging Fast image acquisition 4D imaging capability

Imaging Outside Treatment Room To increase throughput some imaging and treatment preparation has been moved outside the treatment room Patients should not be in the treatment room unless they re being aligned for treatment or being treated Various approaches Immobilization/treatment preparation Treatment localization Imaging for adaptive planning protocols

Treatment Preparation Some treatment sites require difficult/time consuming preparation and immobilization CSI Brain cases fluid in surgical sites Head and Neck changes in mask fit Immobilize and image patient outside treatment room to verify that patient pose is correct

Treatment Preparation Outside Tx Room 2 rooms with robotic positioners, lasers, and fixed orthogonal imagers Patient is immobilized and imaged Images are compared to DRRs to assess patient pose, not position Patient immobilization can be adjusted and re-imaged with little time pressure When pose is correct, transported to Tx room

Treatment Preparation Outside Tx Room Anesthesia Suite Imaging Rooms Beam Matched Tx Rooms

Treatment Localization Outside Room In some centers treatment localization is performed outside treatment room Less work in treatment room Access to various imaging modalities Imaging isocenter in one room tied to treatment isocenter in another Careful, multiroom QA protocols Precise patient transport systems

Multi Modality Remote Localization Waiting WPE Essen Change room Unload CT/MRI? Fixed Beams Room Gantry 2 Universal Nozzle Gantry 3 Dedicated Scanning Nozzle Courtesy of Jonathon Farr

Multi Modality Remote Localization Waiting PTC Prague Courtesy of Jonathon Farr

Multi Modality Remote Localization Waiting PTC Prague Courtesy of Jonathon Farr

CT Gurney 40

Load Position Guide rails 41

Handoff in the treatment room 42

Use of Fiducials Fiducial markers used to great effect in photon therapy in place of volumetric imaging Proton specific concerns with use of fiducials CT artifact Dose shadowing

CT Artifact from Fiducials Huang et al., PMB 56 (2011) 5287

Dose Perturbations from Fiducials Huang et al., PMB 56 (2011) 5287

Dose Perturbations from Fiducials Huang et al., PMB 56 (2011) 5287

Proton Specific Imaging Proton beams used to treat uveal melanoma Radiographic localization can be used to position skull and orbit Treatment planning optimizes gaze angle of eye Must be replicated and maintained at treatment

System components a. b. c. a. NI PXI system for image acquisition from CCD camera and monitoring eye movement b. CCD camera on eye snout for proton therapy unit c. Labview program for eye tracking system

Eye tracking system for gated ocular proton therapy Moving eye phantom Eye tracking system for Gated Proton therapy Exact simulation with in-house moving eye phantom using infrared CCD camera Quantitative analysis of eye movement is performed using LabView H/W, S/W. Promoting collaboration with IBA 49 Shin DH, Park SY, et al., Med. Phys., Vol. 39(7), pp. 4265-73, 2012

Eye tracking and gating system for proton therapy of uveal melanomas -Developed an eye tracking and gating system using an image pattern matching algorithm for uveal melanoma proton therapy. Korea Patent No. 10-2008-0034405, 2008 US, Europe, Japan Patents, 2009

Summary Imaging for proton therapy setup verification is catching up to photon modalities Sometimes different priorities and constraints It s an exciting time to be involved in the development of a proton therapy facility