EFFICIENCY COMPARISON OF MODERN VARIABLE SPEED DRIVE TECHNOLOGIES

Similar documents
Principles of Adjustable Frequency Drives

Motor Fundamentals. DC Motor

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Unit 33 Three-Phase Motors

AC Induction Motor Slip What It Is And How To Minimize It

How to Turn an AC Induction Motor Into a DC Motor (A Matter of Perspective) Steve Bowling Application Segments Engineer Microchip Technology, Inc.

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Synchronous motor. Type. Non-excited motors

FREQUENCY CONTROLLED AC MOTOR DRIVE

Motors and Generators

Technical Guide No High Performance Drives -- speed and torque regulation

8 Speed control of Induction Machines

Pulse Width Modulated (PWM)

Principles and Working of DC and AC machines

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

SYNCHRONOUS MACHINES

Pulse Width Modulated (PWM) Drives. AC Drives Using PWM Techniques

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Induction Motor Theory

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

DIRECT CURRENT GENERATORS

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Inductance. Motors. Generators

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

THIS paper reports some results of a research, which aims to investigate the

Modelling, Simulation and Performance Analysis of A Variable Frequency Drive in Speed Control Of Induction Motor

Application Information

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

C Standard AC Motors

The Emergence of Brushless DC Motors Within Medical Applications

Fundamentals of Inverter Fed Motors

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

Phase-Control Alternatives for Single-Phase AC Motors Offer Smart, Low-Cost, Solutions Abstract INTRODUCTION

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

13 ELECTRIC MOTORS Basic Relations

Specifying a Variable Frequency Drive s

Chen. Vibration Motor. Application note

SPEED, the tool for designing electrical machines. Markus Anders, CD-adapco

1150 hp motor design, electromagnetic and thermal analysis

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

Lab 14: 3-phase alternator.

Speed Control Motors. Speed Control Motors. Brushless Motor's Structure and Principle of Operation H-40. Structure of Brushless Motor

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

HIGH SPEED PERMANENT MAGNET SYNCHRONOUS MOTOR / GENERATOR DESIGN FOR FLYWHEEL APPLICATIONS

WHITE PAPER. DC Motors Explained. DC Motors Explained: White Paper, Title Page

ELECTRICAL ENGINEERING Vol. III - Induction Motor and Self-Excited Induction Generator - Tze-Fun Chan

WIND TURBINE TECHNOLOGY

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

Simulation of VSI-Fed Variable Speed Drive Using PI-Fuzzy based SVM-DTC Technique

Outline. Turbine Generators. Generator History 3/25/2014

AC Replacement for DC Mill-Duty Motors

Drives Low Voltage. Adjustable Frequency. Adjustable Frequency Drives Low Voltage Contents

Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC

Basics on electric motors. EJ Moyer, U. Chicago

Basics of Electricity

Lab 8: DC generators: shunt, series, and compounded.

Introduction. Upon completion of Basics of AC Motors you should be able to:

INDUCTION REGULATOR. Objective:

Tuning Up DC Motors and Generators for Commutation and Performance

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

AC Generators and Motors

Understanding Variable Speed Drives

BRUSHLESS DC MOTORS. BLDC 22mm. BLDC Gearmotor Size 9. nuvodisc 32BF. BLDC Gearmotor Size 5

How the efficiency of induction motor is measured?

BALDOR ELECTRIC COMPANY SERVO CONTROL FACTS A HANDBOOK EXPLAINING THE BASICS OF MOTION

Simulation and Analysis of PWM Inverter Fed Induction Motor Drive

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

DC Motor control Reversing

Design and Analysis of Switched Reluctance Motors

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Understanding the Alternator

INSTRUMENTATION AND CONTROL TUTORIAL 2 ELECTRIC ACTUATORS

Three-Phase Induction Motor

Topics to cover: 1. Structures and Drive Circuits 2. Equivalent Circuit. Introduction

How to Optimize Performance and Minimize Size in High Speed Applications High Performance Brushless DC Motors

How To Measure Power Of A Permanent Magnet Synchronous Motor

1. The diagram below represents magnetic lines of force within a region of space.

Analysis of Space Vector Pulse Width Modulation VSI Induction Motor on various conditions

Renewable Energy Laboratory for Engineering Students

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

SIMULATION AND SPEED CONTROL OF INDUCTION MOTOR DRIVES

This slide is hidden. It will not show up during presentation.

3-Phase BLDC Motor Control with Hall Sensors Using 56800/E Digital Signal Controllers

Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors

Enhancing the Design of Electric Machines through the Interaction of Software Tools. Markus Anders Electric machine sector manager CD-adpaco

Simple Analysis for Brushless DC Motors Case Study: Razor Scooter Wheel Motor

CNC Machine Control Unit

ADJUSTABLE FREQUENCY DRIVES APPLICATION GUIDE

ELECTRIC MOTORS. Energy Efficiency Reference Guide STATOR POLE COMMUTATOR LINE

DC motors: dynamic model and control techniques

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

Motors and Inverters for Environmentally Friendly Industrial Equipment

Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

Transcription:

EFFICIENCY COMPARISON OF MODERN VARIABLE SPEED DRIVE TECHNOLOGIES JUNE 1993 BY EDWARD C. LEE POWERTEC INDUSTRIAL CORPORATION

Abstract: Brushless D.C. technology is new to the general industrial maketplace and is one of the new technology variable speed drives. Efficiency and performance comparisons will be made between the various technologies available to assist the end user in choosing a technology appropriate to the job to be done. Basic theory will be presented for Brush type DC, AC induction, AC vector, and Brushless DC types and actual results of independent tests will be presented to support the conclusions. I. Types of Modern Drives A. AC Induction B. Brush DC C. AC Vector D. Brushless DC II. Basic Theory of Operation of Drive Types III. Areas of performance comparison A. Speed/velocity accuracy B. Dynamic Response C. Power Factor D. Line Harmonics E. Efficiency IV. Actual Independent Testing Comparisons A. Punch Press - Constant Speed AC motor vs Brushless DC retrofit of existing machine. B. General test - Brush type DC vs Brushless DC V. Conclusions and Summary A. Brushless DC has advantage in all areas of performance over fixed speed AC. B. Brushless DC has advantage in all areas of performance over Brush DC.

I. Introduction: Variable Speed drive techology has made significant advances in the last 10 years primarily due to the recent availability of both high power switching devices and magnet materials that were not available in earlier years. Technology has been known for 30 years or more to design such equipment but the parts have not been available to make them reliable at competitve prices. A description of basic drive types is presented below together with a summary of the efficiency parameters typical of each type. The specific types referred to are: AC Induction with PWM VVI Controller AC Induction with Vector Controller Brushless DC Brush DC (as a baseline for comparison) II. AC Induction: The AC induction motor was invented by Nikola Tesla in 1924 and became the most commonly used motor type and remains so today. It has the characteristic that motor shaft speed is proportional to the applied frequency and inversely proportional to the number of poles. The induction principle requires that the motor rotor (squirrel cage) develop flux induced from the stator current. This requires that a "slip" occur between the rotating flux of the stator (3600 rpm at 60 hz) and the actual turning speed of the motor shaft (3500 rpm typical for 2 pole motor). Once the rotor flux is established through slip, the flux fields from the stator and rotor interact to produce torque output. The AC motor has the advantage of being stone simple and widely available. Two types of modern drives (there are some variations but they are not widely used) utilize this motor design. They are the PWM type AC Inverter and the newer Vector Inverter. The PWM type Inverter produces three phase sinusoidal current output at frequencies adjustable typically over a range of 3 to 120 hz holding the motor voltage at a constant ratio relative to frequency. This ratio is relatively fixed but it is necessary to increase it at low speeds to correct for the low speed losses and it is typically necessary to let it decrease at speeds above the 60 hz level. This type of controller on an AC motor is open loop. That is, the controller commands the motor to run at a speed but if load causes a change in speed, there is no actual feedback device used to detect and correct the speed change that occurs. While this simple type of controller is acceptable for some applications, it cannot replace high accuracy, high dynamic response requirements usually performed by brush type DC drives.

The Vector controller is similar to the AC PWM variable frequency controller from a power point of view, but works on a completely different control principle. In the vector controller, the flux in the rotor is produced dynamically by the instantaneous current in the stator, as controlled by the solution of an algorithm (formula) that results in the vector current necessary. Vector refers to the amount and the angular direction of the current. This vector changes both in amount and angle dynamically as the motor changes either speed or load, or both and the change can be very quick. Consequently the algorithm; which is based on current, temperature, voltage, speed, and motor inductance and resistance must be continuously calculated fast enough to control the motor parameters. Using this technique, assuming it is properly designed and uses an encoder or other precision feedback device on the motor shaft, provides very good accuracy and dynamic response from a relatively ordinary AC Induction motor. It does not however improve the efficiency of the motor at rated speed and load conditions. III. Brushless DC Drives The Brushless DC motor works on a principle like that of the brush DC machine, hence the name. One can think of it as an inside out DC motor in which the field windings are replaced with permanent magnets and moved from the frame to the shaft. The armature still consists of multiple windings and are moved from the shaft to the frame. In effect the "fields" now rotate and the"armature" stays still. Because of the obvious mechanical similarity to the AC motor, however, the parts are referred to as Stator and Rotor. The power section of the controller is nearly identical to the Vector Inverter and uses a PWM method of current control but the similarity stops there. The current is not controlled sinusoidally, but trapezoidly. Current is also only conducted in two of the three motor wires at a time instead of being conducted in all three of the wires at a time vectorially. Brushless DC is very simple compared to a Vector Drive since it only switches DC to a pair of wires at a time and determines which wires to switch on based on an encoder made inside the motor. This encoder is essentially the "commutator" and is a very simple magnetic device with magnetic sensing switches rather than being an optical device as is typically the case with normal encoders.

Comparisons of efficiency Actual data was taken in a test commissioned by the Ontairo Hydro power company in Canada to determine the comparison of a conventional brush type drive and a Brushless DC type drive for the purpose of determining whether rebates for power savings would be appropriate using the newer technology drive and whether the claims being made by the manufacturer were substantiated by independent testing. The equipment used was a POWERTEC Brushless DC system with a 25 hp Totally Enclosed Non- Ventilated motor (TENV) which was rated for 100:1 speed range at full rated torque and did not require a cooling fan. The brush DC system was an Emerson controller and Leroy-Sommer 20 hp Blower Cooled motor with a 20:1 full torque speed range. The equipment was tested by Ortech International Energy Technologies and a detailed report was prepared for Ontario Hydro (1). The specific characteristics tested were: Efficiency, Power Factor, Accuracy, and input line harmonics. No representatives from the manufacturers of the drives were allowed to be present during the testing. The following data are taken from this report. Tables 1 through 3 show the efficiency of the two systems at variable speeds from 10% to 100% and variable loads from 25% to 100%. The results show Brushless DC efficiency increases over brush type of 13% at full speed and load to 206% at 10% speed, 25% load. Note that there is difference in the rated HP of each system but each system was run to percentages of it's full load rating. BRUSHLESS DC DRIVE, POWERTEC - 25 HP EFFICIENCY IN PERCENT, AC LINE TO OUTPUT SHAFT TORQUE, PERCENT OF RATED 100 87.9 86.7 85.0 78.4 75 85.4 84.9 82.9 76.6 50 80.8 80.0 79.0 72.6 25 69.8 67.6 66.8 64.3 10 65.1 65.1 65.1 58.9 TABLE 1 BRUSH DC DRIVE, EMERSON - 20 HP EFFICIENCY IN PERCENT, AC LINE TO OUTPUT SHAFT TORQUE, PERCENT OF RATED 100 77.8 77.1 76.6 N.A. 75 74.0 72.6 68.7 65.4 50 66.7 65.1 60.9 50.9

25 51.8 50.4 46.7 38.1 10 31.3 30.0 26.9 19.2 TABLE 2 INCREASED PERCENTAGE EFFICIENCY OF BRUSHLESS OVER BRUSH TYPE DRIVE TORQUE, PERCENT OF RATED 100 13.0 14.0 15.5 N.A. 75 15.4 16.6 22.1 17.1 50 21.1 22.8 29.7 42.6 25 34.7 34.1 43.0 78.1 10 108.0 117.0 142.0 206.7 TABLE 3 Tables 4, 5 and 6 present similar data but for Power Factor rather than efficiency. Power factor is a relative measure of how much of the input current is being used to produce useful work versus how much is reactive. The results show significantly higher power factor near base speed for the Brushless DC drive and at low speeds the Brushless DC drive is well over 200% better than the brush drive. BRUSHLESS DC DRIVE, POWERTEC - 20 HP MEASURED AC INPUT POWER FACTOR TORQUE (PERCENT OF RATED) 100.93.95.94.90 75.95.95.94.87 50.95.95.91.81 25.94.92.85.72 10.83.80.77.72 TABLE 4 BRUSH DC DRIVE, EMERSON - 20 HP MEASURED AC INPUT POWER FACTOR TORQUE (PERCENT OF RATED) 100.80.81.81 NA 75.65.64.63.62 50.48.48.47.46 25.32.32.32.33 10.22.22.22.26 TABLE 5 INCREASED PERCENTAGE POWER FACTOR OF BRUSHLESS OVER BRUSH TYPE DRIVE TORQUE (PERCENT OF RATED) 100 16.0 17.2 16.0 NA 75 46.1 48.4 49.2 40 50 100.0 98.0 93.6 76.0 25 193.8 187.5 165.6 118.2 10 277.3 263.6 250.0 176.9 TABLE 6

AC input harmonics were also measured in the same series of tests and harmonics up to the 30th were measured at full speed and half speed at full load. The reader should refer to the complete report if all the harmonic results are desired but full load, full speed results are shown below out to the 13th harmonic. Other speeds and loads show similar results. 4.0 Percent 3.0 2.0 1.0 0.0 1 2 3 4 5 6 7 8 9 10 11 12 13 Harmonic Number Chart 1: POWERTEC Harmonic Results Percent 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 1 2 3 4 5 6 7 8 9 10 11 12 13 Harmonic Number Chart 2: Brush DC Drive Harmonic Results The data show that the 3rd, 5th, 7th, and 9th harmonics which are usually highest and cause the most concern were markedly lower for the Brushless system. Note that the fundamental (1st harmonic) is truncated on both graphs for readability and they are really both 100%, not 4% as shown on the axis. Summary and Conclusions

Based on these data it is obvious that Brushless D.C. demonstrates significant advantages over the conventional brush type technology using the SCR type controller. While there is a more complex controller used with Brushless D.C., it is no more complex than modern variable frequency type drives and the motor is very simple with no wear out parts except bearings. These data show increased efficiency, more accurate speed control, higher power factor, and lower line harmonics than conventional DC drive technology.