Fuel Storage & Control Systems Generator Packaging & Enclosures

Similar documents
Industrial Generator Set Accessories

Dual wall sub-base fuel tanks-ibc Certified kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2)

Industrial Generator Set Accessories

Industrial Generator Set Accessories

Morrison Bros. Co. General Product Specifications

Industrial Generator Set Accessories

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Industrial Generator Set Accessories

Petroleum Storage Tank Compliance 101

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Shop Fabricated Aboveground Tank Construction Standards

OREGON FIRE CODE Interpretations and Technical Advisories

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

Industrial Generator Set Accessories

Midwest Industrial Tanks

Element D Services Plumbing


COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Waste Oil Collection / Storage

Secondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute

The following definitions apply with regard to requirements specified in this document:

NFPA31FuelOilPiping 1 Revised

Industrial Generator Set Accessories

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Industrial Generator Set Accessories

Highland Aboveground Steel Storage Tanks

Drum Dispensing Stations

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Spill Containment Manholes

Northern Region. Underground Storage Tank

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

List of Frequently Utilized Storage Tank Standards and Practices

UST RULES CHANGES. Heather Peters, Environmental Specialist

The following definitions apply with regard to requirements specified in this document:

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

NFPA : Basic Requirements for Storage Tanks

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

SECTION 22 LIGHTNING PROTECTION SYSTEM

IBC Tote Containment Sumps

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Since HMT Inc. 24 Waterway Avenue, Suite 400 The Woodlands, Texas Ph: Fax:

Ethanol Vehicle and Infrastructure Codes and Standards Citations

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Fire Pump Plan Review March 2010

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

FUEL TANKS DOUBLE WALL FUEL TANKS

Underground Storage Tanks

SECTION GROUND WATER STORAGE TANKS

FUEL-OIL PIPING AND STORAGE

Pressure Vessels (Air Compressors) and LPG Tanks

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

Arctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009

SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES TOXIC/HAZARDOUS MATERIAL TRANSFER FACILITY DESIGN GUIDELINES

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

Chemical Feed System Operation and Design Considerations

Section 8 Storage Tanks & Equipment

SECTION DIESEL-DRIVEN, FIRE PUMPS

Steel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA

Aboveground Indoor Tank Design Guidelines

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Reliant Series Fuel Tanks. Day Tanks Filtration Tanks Specialty Tanks

Element D Services Plumbing

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Magnum Mobile Generator MMG55 Specifications

Vacuum drying oven for non-flammable solvents

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

REHABILITATION OF MOBILE HOMES R

LEAK DETECTION ALARM SYSTEM GUIDELINES FOR TOXIC HAZARDOUS/MATERIALS STORAGE

ROOF TOP MOUNTED Air Handler Specification

SECTION AIR CONDITIONING UNIT

Safe Operating Procedure

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Property Policyholder Risk Improvement Report and Hurricane Survey

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

VDL 53 - Vacuum drying oven for flammable solvents

Daily Inventory and. Statistical Inventory Analysis. Daily Inventory and Statistical Inventory Analysis (SIA) are inventory control

Waste Oil Handling, Spill Containment & Lighting

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

MOTOR FUEL DISPENSING SAFETY

FILLING AND PURGING THE SYSTEM

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System

Recommended Fuel Piping Specification For UPP Piping, UL-971

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

BP WIND ENERGY POLICIES AND PROCEDURES

Heavy-Duty Lube and Fuel Truck Sales Tool

Transcription:

Fuel Storage & Control Systems Generator Packaging & Enclosures Options Include: Double-Walled & Fire Rated Tanks, Hurricane Rated & Sound Attenuated Enclosures phoenixproducts 1727 Bennett Street, Jacksonville, FL 32206 904-354-1858 904-354-7929 Fax phoenix.sales@phoenixprods.com www.phoenixprods.com

fueltanks Aboveground & Sub Base Tanks Envirovault & Fire-Steel UL2085 Protected Aboveground Tanks True double-wall construction with lightweight concrete filled interstitial space UL 2085 listed and labeled Protected aboveground tank for flammable and combustible liquids Fire, vehicle impact and ballistic rated Meets requirements for secondary containment, leak monitoring, spill containment, and overfill protection Inner and outer tanks constructed per UL 142 Steel aboveground tanks for flammable and combustible liquids Six inches of lightweight concrete protection between inner and outer tanks provides minimum two-hour fire rating High-build polyester epoxy glassflake impregnated coating used for salt water submersion protection on offshore platforms, 20,000 hour ASTM B117 salt spray tested Primary and emergency vents standard All fittings and protrusions are stainless steel Steel support channel allow visual tank bottom inspection and air circulation Designed to meet or exceed national, state and local codes No exposed concrete Exceeds liability insurance requirements Engineered for seismic IBC standards Integral earthquake and hurricane tie downs Leak detection space provided Meets NFPA 30 and 30A Options Stairs and platforms (aluminum/galvanized steel) meeting OSHA standards with handrails Stainless steel inner and outer tanks Fuel heaters Stainless steel inner and outer tanks Multiple internal compartments Stainless steel accessory equipment boxes and top/remote fill boxes Fuel monitoring and control systems Tank top hand rails approved by OSHA Day tanks with supply and return pumps Custom color matching Fuel polishing systems Dispensing equipment

PowerTank & Double-Wall UL142 Secondary Containment Tanks Steel aboveground tanks for flammable and combustible liquids UL 142 listed and labeled protected aboveground tank for flammable and combustible Meets requirements for secondary containment, leak monitoring, spill containment, and overfill protection No external cross beams or side supports to interfere with generator placement or stairs and walkways Supports generator sets up to 80,000 pounds, with or without enclosures Primary and emergency vents standard Rounded corners allowing proper adherence of industrial grade enamel coating Steel support channel allow visual tank bottom inspection and air circulation Designed to meet or exceed national, state and local codes NFPA 30, 30A, 37 & 110 True double-wall construction for UL certification Exceeds liability insurance requirements Engineered for seismic rating Earthquake and hurricane tie downs Leak detection space provided Options Stairs and platforms (aluminum/galvanized steel) meeting OSHA standards with handrails Fuel heaters Stainless steel fittings, protrusions and fill boxes Stainless steel inner and outer tanks Custom color matching Over-fill spill protection Fuel polishing systems Dispensing equipment Fuel monitoring and control systems Day tanks with supply and return pumps Tank top hand rails approved by OSHA Manway access Remote fill

generatorenclosures Genset Enclosures Weather Proof, Sound Attenuated, High Velocity-Hurricane Zone & Agency for Health Care Administration Fully weather, corrosion and wind load resistant all aluminum enclosure Interlocking aluminum panels, make a lightweight and corrosion resistant housing Standing seam sloped roof, mill-finish aluminum Fixed intake louvers with expanded aluminum and gravity dampers on discharge provide water intrusion prevention Weather-proof gasket and stainless steel hardware on 36-inch doors with padlocking handles Reinforced door and roof structure Wind load rating 150 MPH Optional 200 MPH ALL ALUMINUM, CORROSION, WEATHER, WIND & MISSILE-IMPACT RESISTANT ENCLOSURES Optional Certifications Miami-Dade County Notice of Acceptance Department of Business and Professional Regulations Florida Building Code SUPERIOR STRUCTURAL DESIGN & MISSILE IMPACT PROTECTION

Enclosure Options Motorized air intake and discharge dampers Stainless steel hold-downs Sound attenuation Three point door latches with padlocking handles Reinforcements at all corners and openings 200 MPH wind load construction PE signed & sealed drawings Interior silencer Interior AC and DC lights with timer switch Exterior emergency stop station Electrical and lighting systems Custom paint matching AHCA Compliance High Velocity Hurricane Zone Rating PROTECTIVE ENCLOSURES FOR ALL GENERATOR SIZES

moreproducts Falcon Enclosures & Tanks High quality, economical Fuel Storage and Enclosures for Generators 300kW and Lower UL 142 Listed, FDEP Compliant both inner and outer tanks are completely sealed and pressure tested Meets requirements for secondary containment, leak monitoring, spill containment, and overfill protection Supports generators up to 300KW Accommodates Phoenix Products and factory generator enclosures, both weather-proof and sound attenuated Fill cap, primary vents and emergency vents package standard Steel 2-inch channel supports, allow visual inspection of tank bottom as well as air movement to prevent condensation induced corrosion Black satin industrial grade enamel paint Spill containment with spring-loaded drain valve Leak sensor probe Low and high fuel level floats Interlocking aluminum panels, make a lightweight and corrosion resistant housing Standing seam sloped roof, mill-finish aluminum Fixed intake louvers with expanded aluminum and gravity dampers on discharge provide water intrusion prevention Weather-proof gasket and stainless steel hardware on 36-inch doors with padlocking handles Reinforced door and roof structure Wind load rating 120 MPH; Optional 150 MPH Diesel Director Day Tanks UL 142 double wall secondary containment tanks Optional UL 2085 interstitial concrete filled double wall tanks with 2-hour fire rating Supply & return pumps Control panel with high and low level alarms Leak sensor Emergency and Primary vents Gauge stick Float fuel level Mechanical leak sensor Spare fittings ports Tank drains with ball valve Lockable fill cap Phoenix Products coating system Optional OSHPD certification Diesel Director Remote Fillport Ground level connection to fuel truck fill hose Single or multiple tanks Spill containment Optional control panel and 2, 3 or 4 inch fill pipe sizes with or without booster pumps Lockable, weatherproof stainless steel enclosure Hand pump discharge Two-point alarm for high and leak indication Optional control panel with tank selector, automatic ball valves, digital capacity display Optional stainless steel base stand Additional ball valves UL listed Optional flanged automatic valves Optional fusible link fire valves Optional high capacity pump and motor for fuel transfer from gravity trucks

aboutus About Phoenix Products Based in Jacksonville, Florida, Phoenix Products was established in 1991 as a fuel tank supplier. Our heritage differentiates us from other generator packagers because of our expertise in fueling systems. In fact, we pioneered several innovative fueling alternatives, now widely used and required by many regulatory agencies. For example, our patented Fire-Steel Generator Base Tank, which was the first UL2085 listed base tank, is now a regulatory requirement in many jurisdictions. Also, our Pipe Daytank System allows placement of emergency power systems in locations where it once was impractical or simply not allowed. We understand that fueling systems are an integral part of any Emergency Power System design; not an afterthought. Built to Last Phoenix Products is a pioneer in the use of aluminum structures for enclosure design. Most competitive generator packages are built with steel housings. Our interlocking panel design provides the corrosion resistance of aluminum, yet provides the structural integrity of up to a 200 MPH wind rating, and sound attenuation options up to 45 dba reduction. One Call Does It All With more than 20 years of experience and customers in a variety of environments, we are familiar with virtually every possible requirement or expectation. Our fabrication technicians are highly trained, extremely talented and willing to take on challenging builds. So if you have a special need or custom request, just ask. Phoenix Products is committed to providing superior product design, exceptional quality, timely delivery and competitive pricing. 1727 Bennett Street, Jacksonville, FL 32206 904-354-1858 904-354-7929 Fax phoenix.sales@phoenixprods.com www.phoenixprods.com

phoenixproducts 1727 Bennett Street, Jacksonville, FL 32206 904-354-1858 904-354-7929 Fax phoenix.sales@phoenixprods.com www.phoenixprods.com