Time relays RXKL 1 and RXKM 2H

Similar documents
Current and voltage measuring relays

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Trip circuit supervision relay. Type RXTCS

80 Series - Modular timers 16 A. Features

Three-phase monitoring relay CM-PFE

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

RM4TG20 three-phase network control relay RM4-T - range V

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage Regulator SPAU 341 C. Product Guide

Safety technique. Emergency stop module BO 5988 safemaster

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Circulating Current Relay. Type IRXm

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

15 Series - Electronic step relay and dimmer. Features SERIE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Telephone- and leased line modem for industrial applications TD-36

Analog signal converters CC-E I/I Current / current isolators

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

80 Series - Modular timers 16 A. Features

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Rack mounted telephone- and leased line modem for industrial applications

Waveguide Access Point WGA631. Product Guide

Electronic overload relay EF65, EF96 and EF146

Auxiliary Relay. Type P8n, PQ8n, PN8n

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Combined overcurrent & earth-fault relay. Type SPAJ 140 C

Electronic overload relay EF19 and EF45

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Power Meter Series 700

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Communication Unit 560CMU05 Data sheet

Pluggable interface relays CR-P Pcb relays

60 Series - General purpose relays 6-10 A. Features

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Energy Management Energy Meter Type EM23 DIN

Arc Protection Relay REA 10_. Product Guide

RY2 miniature industrial relays

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

E-STOP relays, safety gate monitors

Safety automation solutions

Speed Control Relays SX2

Quick Connect. quick - simple - efficient.

13 SERIES. Electronic step relays A

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

7.5 Watt AC-DC Switch Power Supply

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Capacitor Protection Relay SPAJ 160 C. Product Guide

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver.

Thermistor motor protection

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

FP2 Relay. The Best Relaytion

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Data Sheet. Electro-mechanical counters Hengstler 800 series

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Disturbance Recoder SPCR 8C27. Product Guide

Arc Terminator Active Arc-Resistant Switchgear

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Pilot-wire differential relay for lines with two or more terminals

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

CompactLogix Power Supplies Specifications

E-STOP relays, safety gate monitors

Transcription:

Time relays and (xx05000257.tif) (SE940715.eps) Features For protection, control, signal and industrial applications Time setting 30 ms to 99 h Suitable for AC and DC operation Microprocessor design with digital settings High accuracy and performance On-delay relay with continuous, single pulsed and flashing output functions On-delay and off-delay relay with continuous or single pulse output Operating mode for integrating time. Contact for start indication or supervision of supply voltage LED indication of start, elapsed time and operation Application These high performance time relays are intended for use in protection systems, automation control equipment, industrial processes, and control and signal systems. and can replace most other types of time relays due to their wide setting ranges and large operative ranges for both DC and AC voltages. is available in four variants adopted to different rated voltage ranges. Variant A covers the largest voltage range and can be used for all rated voltages. If the energisation of the time relay is controlled by a contact outside the relay cubicle there is a potential risk that the wiring between the contact and the relay can be subjected to an earth-fault. If this occurs in a DC battery system, the relay will be energized with a voltage pulse with a maximum value of about 50 % of actual voltage and decreasing over time to a steady-state value. To avoid an unwanted operation, in such applications, we recommend use of a variant that will only operate when the applied voltage is larger than 55 % of the system rated voltage. See Start voltage in table 1, defining these variants. When is to be used as a flasher relay and also for replacement of older flashing relays e.g. type RXSU 2 and 4 our recommendations are found in Application Instructions 1MRK 508 002-WEN, available on request.

Design and installation The is a DC or AC voltage operated, high-precision, digital on-delay relay utilizing a microprocessor for the time functions. The relay has two electromechanical output relays providing two medium-duty changeover contacts. The timing starts when the energising voltage is applied to terminals 11 and 21 and after the setting time has elapsed, the output switches to the operate condition. Each time the voltage supply is interrupted for a period exceeding the relay recovery time, the relay releases and the timing restarts from the beginning. The time setting is done by three rotary switches marked K, a and b. The product of the scale factor K and the sum of a and b gives the set operate time (t) for the relay, i.e. t= K x (a+b). The setting time can not be changed while the relay is energised. For the continuous function the scale factor K can be set to 1 ms, 10 ms, 0,1 s, 1 s, 10 s, 1 min, 10 min or 1 h. The switch a can be set between 0 and 90 in steps of 10, and the switch b can be set between 0 and 9 in steps of 1. The recommended setting range for a + b is 10 to 99. The nominal setting time range is 30 ms to 99 h. The switch K can also be set for two different pulse functions. One giving a single 500 ms output pulse and the other for flashing output with a pulse frequency of 30 to 600 pulses per minute. In the position for a single pulse, the scale factor is 0,1 s. The sum of the switches a and b can in this case be set between 1 and 99, giving an on-delay setting time range 0,1 to 9,9 s. When the setting time has elapsed, the output relays operate but release after 500 ms. In the position for flashing function, the scale factor is 10 ms. The switches a and b should be set in the range 5 and 99, giving the setting time range 50 to 990 ms. When the relay is energized the output periodically switches on and off with identical pulse on time and pulse off time.the setting time range corresponds to 30 and 600 flashes per minute. The number of flashes per minute is equal to 30000 divided by set time in milliseconds. The is a DC or AC voltage operated, high-precision, digital on-delay and offdelay relay utilizing a microprocessor for the time functions. The relay has three electromechanical output relays providing one instantaneous and two delayed medium-duty changeover contacts. The instantaneous output switches to the operate condition / release condition, immediately upon applying / removing voltage to terminals 111 and 121. The time setting is done by three rotary switches marked K, a and b. The product of the scale factor K and the sum of a and b gives the set operate time (t) for the relay, i.e. t = K x (a+b). The setting time can be changed while the relay is energised. If it is done, the relay will restart and operate when the new setting time has elapsed. The scale factor K can be set to 1 ms, 10 ms, 0,1 s, 1 s, 10 s, 1 min, 10 min or 1 h. The switch a can be set between 0 and 90 in steps of 10, and the switch b can be set between 0 and 9 in steps of 1. The recommended setting range for a + b is 10 to 99. The nominal setting time range is 30 ms to 99 h. On the front, the relay has four yellow LEDs for start and elapsed time indications and one red LED for indication of operation. When the timing starts, a yellow LED begins to flash. After one fourth of the setting time the LED gets a steady light and the next LED starts to flash. In this way the elapsed time is indicated in quarters of the setting time. At operation the yellow LEDs are turned off and the red LED turns on. This LED can be set for either latching or automatically reset when the energising voltage is disconnected. At latching the LED is reset with a push button on the front of the relay or when the supply voltage to terminals 111 and 121 is interrupted. The relay has an 8-pole programming switch on the front for making the following selections: on-delay or off-delay time function latching or automatic reset indication continuous or summation time measuring pulse function 100, 250, 500 or 1000 ms The relay occupies one seat (2U 6C). 2 Time relays - 1MRK508002-BEN Revision: B

For on-delay time function with continuous time measuring and automatic reset of indication, the timing starts and the instantaneous output relay operates, when the energising voltage is connected to terminals 111 and 121. After the setting time has elapsed, the delayed output relays switch to the operate condition. For summation time measuring, latching indication and offdelay time function, the supply voltage shall continuously be connected to terminals 111 and 121. Then the instantaneous output relay is in operate condition.the on-delay timing starts when terminal 312 is connected to terminal 111. For off-delay time function, the delayed output relays immediately switches to the operate condition when terminal 312 is connected to terminal 111. The timing starts when this connection is disconnected. For continuous time measuring the delayed output relays switch to the release condition when the setting time has elapsed. Installation The time relays and can normally be installed without any special precautions. For relays energised via contacts outside the relay cubicle, it is an recommended to use an RXKL variant having a start voltage larger than 55 % of rated voltage.this is to avoid influence on the time function of induced AC voltages or DC earth faults. RXKM in such applications, it is recommended to use terminal 312 to control the function, as the start value of that input is larger than 55 % of the voltage applied to terminals 111 and 121. For on-delay function the relay shall then be set for latching indication. For summation time measuring, the delayed output relays switch when the setting time has elapsed by summing up the time intervals during which voltage has been applied to (ondelay) or removed from (off-delay) terminal 312. The output relays release and the timing and the LEDs reset, if the supply voltage to terminals 111 and 121 is interrupted. Reset of elapsed time and the LEDs can also be done with the reset push button on the front. The relay occupies two seats (4U 6C). Time relays - 1MRK508002-BEN Revision: B 3

Technical data Table 1: Energizing quantities, rated values and limits for Function Measurement Rated voltage U r variant A variant B variant C variant D Setting time range continuous output function single pulse output function flashing output function Scale constant K Release time Recovery time before operation after operation Overshoot time Pulse length (single pulse) Start voltage variant A variant B variant C variant D Release voltage variant A variant B variant C variant D Nominal operative voltage range Power consumption at voltage 24/48 V DC 110/250 V DC 100/240 V AC Setting accuracy continuous output function single pulse output function (setting < 0,7 s) single pulse output function (setting > 0,7 s) flashing output function Repeatability in operate time Change in operate time at voltage change within the nominal operative range Change in operate time at temperature change within the nominal operative range On-delay with continuous, single pulse and flashing output functions Continuous 24-250 V DC / 24-240 V 50-60 Hz 48-250 V DC / 48-240 V 50-60 Hz 110-250 V DC / 110-240 V 50-60 Hz 220-250 V DC / 220-240 V 50-60 Hz 10-99 x scale constant K 1-99 x 0,1 s 5-99 x 10 ms 1 ms, 10 ms, 0,1 s, 1 s, 10 s, 1 min, 10 min and 1 h < 50 ms 500 ±10 ms 15-18 V DC / 14-19 V 50-60 Hz 30-36 V DC / 28-38 V 50-60 Hz 75-82 V DC / 65-85 V 50-60 Hz 150-165 V DC / 130-170 V 50-60 Hz >10 V DC / AC >20 V DC / AC >25 V DC / AC >25 V DC / AC 80-110 % of rated voltage DC 85-110 % of rated voltage 50-60 Hz before operation after operation 0,15/0,25 W 0,8/1,0 W 0,6/1,5 W 2/3 W 1/2 VA 2/3,5 VA < 0,5% of set value or 10 ms (20 ms for AC supply) < 25 ms < 0,5% of set value or 10 ms (20 ms for AC supply) < 10 ms < 0,05% of set value or 5 ms (15 ms for AC supply) < 0,1% of set value or 10 ms < 0,1% of set value or 5 ms 4 Time relays - 1MRK508002-BEN Revision: B

Table 2: Energizing quantities, rated values and limits for Function Measurement Rated voltage U r Start voltage input 312-121 Release voltage input 312-121 Setting time range Scale constant K Release time input 312-121, on delay input 312-121, off delay Recovery time input 312-121, on- and off delay Overshoot time input 312-121, on delay input 312-121, off delay Pulse length (single pulse) Nominal operative voltage range Power consumption at voltage 24/48 V DC 110/250 V DC 100/240 V AC Setting accuracy at U=110 V and setting (10-99) x K Repeatibility in operate time Change in operate time at voltage change within the nominal operative range Change in operate time at temperature change within the nominal range On-delay and off-delay with continuous and single pulse output functions Continuous and summation 24-250 V DC and 48-240 V 50-60 Hz 16-19 V DC, 18-24 V AC 55-70 % of supply voltage DC > 15 V AC and DC > 40 % of supply voltage DC 10-99 x scale constant K 1 ms, 10 ms, 0,1 s, 1 s, 10 s, 1 min, 10 min and 1 h < 40 ms < 50 ms < 30 ms < 40 ms < 40 ms < 30 ms 500±10 ms 80-110 % of rated voltage before op. after op. 0,6/0,9 W 1,3/1,6 W 1,8/4,0 W 2,8/5,5 W 2,5/6 VA 4/8VA < 0,5% of set value or 10 ms (20 ms for ACsupply) < 0,05% of set value or 5 ms (15 ms for AC supply) < 0,1% of set value or 10 ms < 0,1% of set value or 5 ms Table 3: Environmental conditions for and Environmental conditions Nominal operative temperaure range -20 C to +55 C Transport and storage temperature range (IEC 60068-2-1 and 2) -40 C to +70 C Humidity test (IEC 60068-2-30) Degree of protection Damp heat 93-95 %, 25-55 C, 6 cycles 12+12 h IP 42 (RXKL) and IP44 (RXKM) Time relays - 1MRK508002-BEN Revision: B 5

Technical data Table 4: Electromagnetic compability test for and Tests Fast transient test (SS 436 15 03) 4-8 kv, class PL 4 1 MHz burst test (IEC 60255-22-1) 2,5 kv, class 3 Electrostatic test (IEC 60 255-22-2) air discharge 15 kv, class 4 contact discharge 8 kv, class 4 indirect application (IEC 6100-4-2) 8 kv, level 4 Electromagnetic field test radiated (IEC 61000-4-3) 10 V/m, 26-1000 MHz, level 3 radiated pulse (ENV 50204) 10 V/m, 900 MHZ conducted (IEC 61000-4-6) 10 V, 0,15-80 MHz, level 3 Fast transient test, (IEC 60255-22-4) 4 kv, class 4 Emission tests, (EN 55011) conducted emission 0,15-30 MHz, class A radiated emission 30-1000 MHz, class A Table 5: Insulation tests for and Table 7: Contact data for and Tests Data Dielectric test (IEC 60255-27) 2,0 kv 50 Hz, 1 min Max. system voltage within a contact set DC/AC 250 V/250 V Impulse voltage test (IEC 60255-27) 5,0 kv, 1,2/50 μs, 0,5 J Insulation resistance (IEC 60255-27) > 100 MΩ at 500V Table 6: Mechanical tests for and Current carrying capacity (for already closed contact) 200 ms/1 s 30/15 A continuously 5 A Making and conducting capacity L/R< 10 ms 200 ms/1s 30/10 A Breaking capacity for AC, PF>0,4, max 250V 8,0 A DC,L/R<40 ms U = 24 V/48 V 2,0 A/1,0 A U = 110 V/125 V 0,4 A/0,3 A U = 220 V/250 V 0,2 A/0,15 A Tests Vibration test (IEC 60255-21-1) 0,075 mm/1,0 g, 10-150 Hz, Class 2 Response test 2,0 g, 10-150 Hz, 20 sweeps, Class 2 Endurance test Shock tests (IEC 60255-21-2) Response test 10 g, 11 ms, 3 pulses, Class 2 Withstand test 30 g, 11 ms, 3 pulses, Class 2 Bump test (IEC 60255-21-2) 10 g, 16 ms, 1000 pulses, Class 1 Seismic test (IEC 60255-21-3) X- and Y-axes 11 mm/3 g, 1-50 Hz, Class 2 extended Z-axis 7,5 mm/2 g, 1-50 Hz, Class 2 extended Table 8: Additional general data Dimensions 2U 6C 4U 6C Weight 190 g 400 g 6 Time relays - 1MRK508002-BEN Revision: B

Mounting, diagram and ordering Mounting The relay shall be mounted on separately ordered COMBIFLEX bases. For mounting details refer to the catalogue for COMBIFLEX connection and installation components. Diagrams 11 21 15 16 17 25 26 27 (96000142.eps) + 111 121 + 312 316 317 318 323 324 325 326 328 327 (96000143.eps) Ordering Specify: Time relay or Quantity Ordering No., variant A, U r =24-250 V DC/24-240 V AC 1MRK 000 066-AB, variant B, U r =48-250 V DC/48-240 V AC 1MRK 000 066-BB, variant C, U r =110-250 V DC/110-240 V AC 1MRK 000 066-CB, variant D, U r =220-250 V DC/220-240 V AC 1MRK 000 066-DB 1MRK 000 142-A Related documents Documents COMBIFLEX connection and installation components Relay mounting systems Instruction for Application 1MRK 513 003-BEN 1MRK 514 001-BEN 1MRK 508 002-WEN Time relays - 1MRK508002-BEN Revision: B 7

Contact us ABB AB Substation Automation Products 721 59 Västerås, Sweden Phone: +46 (0) 21 32 50 00 www.abb.com/protection-control Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. ABB AB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in part is forbidden without prior written consent of ABB AB. 1MRK508002-BEN Revision: B ABB India Limited Plot no. 4A, 5 & 6, II Phase Peenya Industrial Area Bangalore - 560 058. India Phone: +91 80 2294 9632 Facsimile: + 91 80 2294 9188 Copyright 2014 ABB. All rights reserved.