Fan curves and optimum operating points

Similar documents
FAN PROTECTION AGAINST STALLING PHENOMENON

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area

Data Center Cooling. The engineer s choice

ebm-papst North America

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Mobile field balancing reduces vibrations in energy and power plants. Published in VGB PowerTech 07/2012

TABLE OF CONTENT

OPERATING FANS IN PARALLEL IN VIEW OF VARIABLE FLOW RATE OUTPUT

Fan Basics and Selection Criteria (How to Use)

Accurate Air Flow Measurement in Electronics Cooling

Centrifugal Fans and Pumps are sized to meet the maximum

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Equilibrium of a firm under perfect competition in the short-run. A firm is under equilibrium at that point where it maximizes its profits.

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

Basic Rowing Technique. Autor: Thor S. Nilsen (NOR) Editors: Ted Daigneault (CAN), Matt Smith (USA)

Circulator Fan Performance Testing Standards BY CHRISTIAN TABER, BEMP, HBDP, MEMBER ASHRAE

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

Shrinking a power supply and the challenge to maintain high reliability.

Highly flexible couplings

Theory of turbo machinery / Turbomaskinernas teori. Chapter 4

Design and testing of a high flow coefficient mixed flow impeller

Midterm Exam #1 - Answers

Circumference of a Circle

1150 hp motor design, electromagnetic and thermal analysis

Wind Energy Math Calculations Calculating the Tip Speed Ratio of Your Wind Turbine

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

product application guide

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

Minimizing Fan Energy Costs. Parts 1 and 2

Fluid Dynamics Basics

VariTrane Duct Designer An in depth look...

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Chapter 3.5: Fans and Blowers

Optimum fin spacing for fan-cooled heat sinks

How Curve Shape Can Influence Pump Selection

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

Absolute and relative humidity Precise and comfort air-conditioning

Air Conditioning Clinic

Pfaudler Mixing Systems. Reduce processing times and save costs

Demand Based Static Pressure Reset Control for Laboratories

Practice Problem Set 2 (ANSWERS)

Experiment 3 Pipe Friction

A Simplified 3d Model Approach in Constructing the Plain Vane Profile of A Radial Type Submersible Pump Impeller

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

The Effects of Start Prices on the Performance of the Certainty Equivalent Pricing Policy

Understanding patent claims (d) Double pipe

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.

NUMERICAL ANALYSIS OF WELLS TURBINE FOR WAVE POWER CONVERSION

7.3 Fit selection. Inner ring: Rotating. Outer ring: Stationary. Inner ring: Stationary. Outer ring: Rotating. Inner ring: Stationary

Performance prediction of a centrifugal pump working in direct and reverse mode using Computational Fluid Dynamics

FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER

Odyssey of the Mind Technology Fair. Simple Electronics

Duct Design. Presented by Dave Janquart

Circuit diagrams and symbols (1)

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Name Partners Date. Energy Diagrams I

HVAC Efficiency Definitions

ENGINEERING DATA. Fan Performance Troubleshooting Guide

ebm-papst North America

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Compact Fans for AC and DC. Catalogue 2008

Physical Principle of Formation and Essence of Radio Waves

EC medium pressure axial fans. The effi cient system solution.

Fatigue Analysis of an Inline Skate Axel

chapter Perfect Competition and the >> Supply Curve Section 3: The Industry Supply Curve

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Development of the Inverter Air Conditioner for Southeast Asia in FY2014

Shear Force and Moment Diagrams

5. FANS AND BLOWERS. 5.1 Introduction. 5.2 Fan Types

Pushing the limits. Turbine simulation for next-generation turbochargers

Installation Manuals Version n. 01 of 14/06/2013

Application and Design of the ebooster from BorgWarner

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

MODELING OF CAVITATION FLOW ON NACA 0015 HYDROFOIL

PFT Two stage axial fan The high pressure fan for modern boiler plants

Lesson 2 - Force, Friction

INDUSTRIAL KILN & DRYER GROUP KILN & DRYER ROLLER ADJUSTMENTS

DSRQ - DSRSQ - DSRSQ-THERM

FAN SYSTEM REPLACEMENTS IN HVAC EQUIPMENT TO IMPROVE ENERGY

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

Conceptual Questions: Forces and Newton s Laws

Chapter 25: Exchange in Insurance Markets

PowerScore Test Preparation (800)

Chapter 2 Pump Types and Performance Data

Conlift1, Conlift2, Conlift2 ph+

How To Understand General Relativity

EXPERIMENTAL RESEARCH ON FLOW IN A 5-STAGE HIGH PRESSURE ROTOR OF 1000 MW STEAM TURBINE

Power and Cooling for Ultra-High Density Racks and Blade Servers

Lenses and Telescopes

CRANFIELD UNIVERSITY ELEFTHERIOS ANDREADIS DESIGN OF A LOW SPEED VANEAXIAL FAN SCHOOL OF ENGINEERING. MPhil THESIS

FLUID FLOW AND MIXING IN BIOREACTORS (Part 2 of 2)

Transcription:

Press News Airflow performance and speed at a glance: Fan curves and optimum operating points Fans create a flow of air, which they can then force through equipment that needs cooling. The necessary output is determined from the flow rate and the required static pressure. If the airflow through the equipment is restricted to any great extent by built-in components or bends and junctions, then this will lead to a loss of pressure; the fan will try to compensate for this by an increase in the static pressure, though the fan will have to work harder than in free air operation. The characteristic curve of the fan gives precise information about the flow rate at specific static pressures. The whole airflow operation for cooling is often seen as very complicated, but this in reality is not the case. With a fan the flow rate decreases as the loss of pressure ( resistance ) in the equipment increases. The actual construction and nature of the appliance leads to differing characteristics for the pressure loss depending on the flow rate. This is termed the characteristic curve of the appliance. It describes the progression in the static pressure necessary to force through the equipment a particular airflow against the resistance created by components within the equipment. This is calculated according to technical parameters concerning the flow. Characteristic curves, the fingerprint of the fan Even with the active components of the fan, one works with a characteristic curve. In contrast to the purely technical flow parameters of the device curve, here the influence of the drive motor must be taken into consideration. This additional parameter has a greater influence on the shape of the curve. Because of the limitations placed on them because of their construction, all small fans have relatively small low-performance drive motors. This means that depending on the different loads placed on them their speed and power consumption alter dramatically. With axial fans for example the maximum speed is achieved at the greatest flow rate but at the same time with the lowest power consumption. As the static pressure rises, so the power requirement increases, the speed of the motor falls until the power available from the motor once again matches the power demand of the ebm-papst Inc. 100 Hyde Road. Farmington, CT 06034. Phone (860) 674-1515. Fax (860) 674-8536 sales@us.ebmpapst.com. www.ebmpapst.us

fan impeller. If one observes the interaction between the appliance and fan it becomes clear that both curves have an intersection point. This is the so-called optimum operating point of the fan (Fig 1). Here the technical flow requirements of the appliance correspond with the delivery possibilities of the chosen fan. In order to be able to quickly assess this physical detail for the fan in question, the fan specialist ebm-papst shows these characteristic curves in its catalogue, together with other relevant fan data. Axial fans are designed to move large quantities of air with low counterpressure. If the loss of pressure in the appliance increases, then the airflow quickly falls off (Fig 2). The saddle point in the fan curve is typical for axial fans. If the airflow is further restricted the flow round the impeller blades breaks away at the hub. This leads to a drop in pressure and a substantial increase in the noise level, caused by turbulence. Radial fans however, thanks to their design, are able to transfer more energy to the air molecules. With radial fans the airflow always exits the impeller at its outer circumference and thanks to the higher circumferential velocities can thus achieve a higher pressure level. The speed curve has a distinct lowest point, but this can be at higher or lower airflow values (Fig 3). The efficiency achieved is at around the same level as with an axial fan. Diagonal fans combine the extremes of axial and radial fans. Depending on their layout these fans can demonstrate either more axial or more radial characteristics. Special versions can even achieve an almost constant motor speed over the whole operating range. There is no longer any saddle in the fan curve, which overall is flatter than that of a radial fan (Fig 4). The different shapes of the various fan curves are typical for a particular type of fan. However even fans of the same type of construction can show peculiarities - either because of their design or the motor with which they are equipped. Dimensionless numbers If one goes a step further when looking at different fans, the question often arises as to whether there is a simple way of comparing the different designs. This is where so-called dimensionless numbers can be of assistance. If one calculates the functional dependence of the static pressure and flow rate with reference to the circumferential velocity u, the outside diameter of the impeller wheel D and the density of the air, this gives the dimensionless

volume number j and the pressure number Y. Using these it is possible to calculate quickly the performance of geometrically similar fans having different speeds and sizes. It is also possible to show clearly in a diagram a comparison between various types of fans (Fig 5) and look at the effects of designs incorporating differing types of construction, size or speed. Fan curves are thus meaningful diagrams that provide the user with the necessary information concerning the performance of a fan under different operating conditions. For this reason leading fan manufacturers such as ebm-papst show these diagrams in their catalogues. Using dimensionless numbers, standard characteristic curves offer the user a simple and quick way to compare the performance of the various types of fan on offer.

PAP053_Intro.jpg

PAP053_fig1.jpg Fig 1: Calculation of the operating point PAP053_fig2.jpg Fig 2: Change in speed and efficiency of an axial fan

PAP053_fig3.jpg Fig 3: Change in speed and efficiency of a radial fan PAP053_fig4.jpg Fig 4: Change in speed and efficiency of a diagonal fan

PAP053_fig5.jpg Fig 5: Comparison between the performance curves for different fan designs