Labconco FreeZone 4.5 Liter Freeze Dry System Bergen County Technical Schools Stem Cell Lab

Similar documents
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Instruction manual for Firstline FCS12000CH

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

Chapter Test A. States of Matter MULTIPLE CHOICE. a fixed amount of STAs2 a. a solid. b. a liquid. c. a gas. d. any type of matter.

Flushing and Cleaning the A/C System

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Meaco 30L and Meaco 40L dehumidifier instruction manual

Single Zone LCD Thermostat Operating Instructions

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

SECTION 2 3 OPERATION OF INSTRUMENTS AND CONTROLS. Lights, Wipers and Defogger

Split Air Conditioner

Chemistry 13: States of Matter

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

Portable Air Conditioner

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Tassimo The Art of the Perfect Cup

Use and Care Manual. Model CPA12KH AIR CONDITIONER

2-SLICE COOL TOUCH TOASTER

CARING FOR YOUR WATER HEATER

PORTABLE AIR CONDITIONER

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER

Boiler Preparation, Start-Up and Shutdown

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Peasouper Operator s Manual

National- Spencer Inc.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Description of a Basic Vacuum System

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

75th anniversary blender

Refrigeration Basics 101. By: Eric Nelson

Chapter 2, Lesson 5: Changing State Melting

Ultrasonic support removal tank

GenStore Archive Cabinet

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

PBX Series Quick Fit Connector Bimetallic Steam Traps

LCD BacPac. User Manual + Warranty Info

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

VCR Ion Beam Sputter Coater

Physical Properties of a Pure Substance, Water

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

REMOTE CONTROL MANUAL

Operating Instructions Split System Air Conditioner

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

THE NEWCASTLE UPON TYNE HOSPITALS NHS FOUNDATION TRUST SAFE USE AND STORAGE OF LIQUID NITROGEN AND SOLID CARBON DIOXIDE (DRY ICE)

Dehumidifier Users manual. For Models: DH45S DH65S

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

KINDERGARTEN WATER 1 WEEK LESSON PLANS AND ACTIVITIES

Digital Photo Picture Frame. Operation Manual

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

Deluxe Bottle Warmer

Triple Point Experiment

PC1130 Electric Air Compressor

Every mathematician knows it is impossible to understand an elementary course in thermodynamics. ~V.I. Arnold

1. The Kinetic Theory of Matter states that all matter is composed of atoms and molecules that are in a constant state of constant random motion

WARNING To reduce the risk of. READ ALL INSTRUCTIONS BEFORE USING. KEEP AWAY FROM WATER DANGER Any appliance is

PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition

Standard Operating Procedure for a Chemical Spill

OPTIONAL SLENDER REMOTE CONTROL

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Important Safeguards

Micro Hair Extension Machine Model EX-P100 Patent-pending. Operating Manual

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Physical Chemistry Laboratory I CHEM 445 Experiment 6 Vapor Pressure of a Pure Liquid (Revised, 01/09/06)

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

1. The Determination of Boiling Point

PC1131 Electric Air Compressor

Automobile Air Conditioning Primer

Mold Alert... Operation Manual P0270

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

MAINTENANCE & TROUBLESHOOTING

Action Camcorder Rollei Youngstar USER MANUAL

Hygiene Standards for all Food Businesses

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

Standard rules SR3 (2016) Dry cleaning

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Recharge Procedure for Telemark TVP-2000 and TVP-3500

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Bottom Loading Water Dispenser

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

CG PTFE Diaphragm Liquid Transfer Pump

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

STANDARD OPERATING PROCEDURE S (SOP S) FOR HAZARDOUS ANALYSIS CRITICAL CONTROL POINT (HACCP) PLANS

Transcription:

Labconco FreeZone 4.5 Liter Freeze Dry System Bergen County Technical Schools Stem Cell Lab Room 213

Labconco FreeZone 4.5 Liter Freeze Dry System Information Sheet The Labconco FreeZone 4.5 Liter Freeze Dry System is an instrument used in sample preparation, and for the preservation and storage of biological specimen, pharmaceuticals, and foods. Freeze drying, or lyophilization, is one of a number of dehydration methods, but is especially suited for substances that are heat sensitive. The process of freeze drying works by freezing the material, and then reducing the surrounding pressure and adding enough heat to allow the frozen water in the material to sublime directly from its solid phase to a gas. The Freeze Dry Process Freeze drying has been used extensively in the development of pharmaceuticals, such as antibiotics, and preservation of biological samples, such as proteins, plasma, viruses, and microorganisms. This process has been shown to be nondestructive in nature, which has been demonstrated by the retention of viability in freeze dried viruses and microorganisms. As already stated, freeze drying is a process of freezing a sample and reducing the pressure, followed by a heating that causes the solid water to sublime. The basis of the sublimation process involves the absorption of heat by the frozen sample in order to vaporize the ice, the use of a vacuum pump to enhance the removal of water vapor from the surface of the sample, the transfer of water vapor to a collector, and the removal of heat by the collector in order to condense the water vapor.

Freeze Dry Rates The efficiency of the freeze drying process is dependent upon the surface area and thickness of a sample, the collector temperature and vacuum obtained, the eutectic point (melting point), and solute concentration of the sample. See the table below for examples of materials and dry times. In most cases, the greater the surface area of a sample is, the faster the rate of freeze drying. In contrast, the thicker a sample is, the slower the rate of freeze drying. The heat of sublimation is often absorbed on one side of a frozen sample and must travel through the frozen layer to vaporize the water at the other surface. The water vapor must also travel through a layer of dried material. Therefore, the thicker a sample is, the greater the chance that the dried layer may collapse, causing a decrease in the rate of drying. The process of sublimation is accomplished using the collector and vacuum pump. The collector should always be set as 15 to 20 C colder than the eutectic point of the sample. This traps the vapor as ice. The low pressure caused by the vacuum then draws the vapor to the collector. This vacuum is essential to maintain an efficient rate, since diffusion occurs very slowly under normal atmospheric conditions. The rate of freeze drying is directly proportional to the vapor pressure, and the vapor pressure of a sample is dependent upon both the eutectic temperature and the solute concentration of a sample.

Labconco FreeZone 4.5 Liter Freeze Dry System Quick Start Guide Before starting the Labconco FreeZone 4.5 Liter Freeze Dry System, the user must: 1. Wipe the interior of the collector chamber with a soft cloth or paper towel to remove any accumulated moisture. 2. Using a soft, lint free cloth or paper towel, wipe the collector chamber gasket to remove any dirt and contaminants that could cause a vacuum leak. 3. Check the collector chamber drain hose to ensure the hose is free of moisture and that the drain plug is securely installed. Note: The Freeze Dryer will not start if any moisture is detected. 4. Check that each sample valve is closed, or in the Vent position. a. The Vent position is shown to the right. The bevel on the valve knob is facing upward when in the Vent position. 5. Make sure that the oil level in the instrument s vacuum is not low, and that the oil is clear. Once all of these items have been checked, the user can proceed to using the instrument. Turn the instrument on by pressing the Power Button, located on the lower right side of the instrument.

Configuring the Freeze Dryer The Freeze Dryer is already set-up with lab standards. If these conditions need to be altered for a freeze dry protocol, proceed with the following steps under instructor supervision. Otherwise, continue to the next section. 1. Press the Menu Button on the Control Panel. a. The LCD Screen will show Vacuum Units. i. Press Select until the desired unit (mbar, Pa, or Torr) is flashing. Press Menu to select and advance to the next screen. b. Vacuum Set Point will be the next item on the LCD Screen. This is used to tell the instrument how low the vacuum needs to be set for the sample being used. i. Press Select until the desired set point is shown on the screen. Press Menu to select and advance to the next screen. c. Temperature Units is the next item on the LCD Screen.

i. Press Select to select whether to display the temperature in Celsius or Fahrenheit. When the item is flashing, press Menu to select and advance to the next screen. d. The next two screens show the total hours that the Refrigeration and the Vacuum have been used. No changes need to be made on these screens. Press Menu to advance past each. e. The next screen is the Transmission Rate Screen. This is used to change the time between data transmissions. i. Press Select to change the time interval to 10, 30, 60, 300, or 600 seconds. Press Menu to select and advance to the next screen. 2. After moving through these screens, the instrument will return to the LCD Main Screen, and show the conditions of the instrument. At this point, the user will be able to proceed to the Freeze Drying Procedure. Starting Up a Freeze Dry Protocol The Freeze Dryer can be operated in one of two modes: Automatic and Manual. Determine which mode to use, and follow that procedure.

Automatic Start-Up 1. To run the Auto Mode, press the Refrigeration Auto Button on the Control Panel. This will start the instrument s refrigeration system. a. The Green LED above the button will illuminate. 2. When the collector temperature reaches -40 C, the vacuum pump will automatically start. a. The Temperature Graph will illuminate LED lights incrementally as the temperature of the unit drops to -40 C. b. The LCD Display will show the actual temperature of the instrument at all times. 3. Once the vacuum starts, the pressure in the instrument will begin dropping until it reaches <0.133mBar. a. The Vacuum Pressure Graph will illuminate LED lights incrementally as the pressure in the unit drops to < 0.133 mbar. The last light will blink when between 0.45 and 0.133 mbar, and then become steady once it reaches 0.133 mbar. b. The LCD Display will read High when the pressure in the instrument is above 5 mbar. It will then display the actual vacuum once the pressure drops below 5 mbar. 4. Once the last green LED light is illuminated for the vacuum, samples can be added.

Manual Start-Up 1. To run the Manual Mode, press the Refrigeration Manual Button on the Control Panel. This will start the instrument s refrigeration system. a. The Green LED above the button will illuminate. 2. When the collector temperature reaches -40 C, the vacuum pump can be started by pressing the Vacuum Button on the Control Panel. a. The Temperature Graph will illuminate LED lights incrementally as the temperature of the unit drops to -40 C. b. The LCD Display will show the actual temperature of the instrument at all times. 3. Once the vacuum starts, the pressure in the instrument will begin dropping until it reaches <0.133mBar. a. The Vacuum Pressure Graph will illuminate LED lights incrementally as the pressure in the unit drops to < 0.133 mbar. The last light will blink when between 0.45 and 0.133 mbar, and then become steady once it reaches 0.133 mbar. b. The LCD Display will read High when the pressure in the instrument is above 5 mbar. It will then display the actual vacuum once the pressure drops below 5 mbar. 4. Once the last green LED light is illuminated for the vacuum, samples can be added.

Freeze Drying Samples Note: The samples should always be pre-frozen. The sample container should always be two to three times the sample size. The freeze drying temperature should always be at least 10-20 C colder than the eutectic temperature of the sample. 1. Connect a pre-frozen sample to a Sample Valve on the Drying Chamber using an adapter. 2. Turn the plastic valve knob from the Vent position to the Vacuum position to open the valve. a. The bevel on the knob should be positioned Downward toward the sample to apply vacuum to the sample. 3. Before adding another sample, allow the system vacuum to return to 0.133 mbar or lower. Repeat for each sample. Note: Adding the samples one at a time and allowing the pressure to return to 0.133 mbar is necessary to ensure that the samples do not melt. 4. Allow the Freeze Dryer to run. Once all of the frost has disappeared from the outer surface of the sample container, and no cold spots can be detected upon handling, the sample is nearly dry (This may take several hours). Continue to dry the sample for several more hours to ensure low moisture content.

5. To remove a container from the instrument after drying is complete, turn the knob back to the Vent position. The sample container can then be removed. Shut Down and Defrosting To shut down and defrost the instrument after the freeze dry procedure is completed: 1. Release the vacuum by turning the plastic knob on a valve to the Open, or Vacuum Position. 2. Press the Vacuum Button on the Control Panel to turn the vacuum pump off. 3. Press the Refrigeration Button next to the illuminated LED to turn the refrigeration system off. 4. Turn off the instrument power by pressing the Power Switch on the lower right side of the instrument. 5. Pull the Collector Chamber Drain Hose out from the left side of the instrument and remove the Drain Plug. Place the hose in a container to collect any condensate from the instrument. 6. Remove the Collector Chamber Lid and allow room temperature air to melt the ice. 7. Once all ice is melted, flush the collector chamber with water and wipe the chamber clean. 8. Once all liquid is cleared from the instrument, close the drain plug and reinsert the hose into the instrument. 9. Make sure the station is neat before leaving the instrument!

Labconco FreeZone 4.5 Liter Freeze Dry System Safety Sheet 1. Samples should be handled according to good laboratory procedures and methods in order to prevent accidents. 2. Dispose of all waste solutions according to waste disposal procedures. 3. Do not remove any panels or cords from the instrument to avoid electrical shock. Do not remove any vacuum hoses from the instrument. 4. Food and drinks should not be placed on or near the instrument. 5. Do not operate the instrument if the vacuum oil level is low. 6. Do not operate the instrument if the vacuum oil is cloudy, discolored, or contains particles. 7. Never operate the instrument or start the vacuum when there is liquid in the collector chamber. This could result in damage to the vacuum pump. 8. Some of the rubber and plastic components of the instrument can be attacked and degraded by certain chemicals and solvents. Thoroughly rinse the components with water after use of these chemicals or solvents in the instrument. A list of these chemicals and solvents is included on the next page. 9. The instrument s collection chamber should be wiped with a soft cloth or paper towel prior to use to remove any accumulated moisture. The collection chamber drain hose must be checked to ensure that it is free of accumulated moisture before use. 10. Dirt, dust, or contaminants on the collection chamber lid gasket can lead to a vacuum leak. Use a soft, linen free cloth or paper towel to remove any dirt or dust prior to use. 11. The instrument will achieve extremely low temperatures (as low as -40 C) and pressure (<0.15 mbar). Be aware of the temperature and pressure when operating the instrument to avoid injury. 12. After a sample had been dried completely, the collection chamber and cooling coil must be defrosted and dried of accumulated liquid. Never attempt to chip ice from the collector coil. Damage to the coil can result.

Chemical Degradation of Instrument Parts

Labconco FreeZone 4.5 Liter Freeze Dry System Instrument Information Sheet Labconco FreeZone 4.5 Liter Freeze Dry System Overview: 1. FreeZone Control Panel 2. Drying/Collector Chamber and Cooling Coil 3. Sample Valves and Ports 4. Power Button

FreeZone Control Panel Overview: 1. LCD Display 2. Menu Button 3. Vacuum Graph Display 4. Collector Temperature Graph Display 5. Automatic Refrigeration Mode Button 6. Manual Refrigeration Mode Button 7. Vacuum Button 8. Select Button 9. Alarm Indicator 10. Automatic Refrigeration Mode Indicator 11. Manual Refrigeration Mode Indicator

Drying/Collector Chamber Overview: 1. Cooling Coil inside of the Drying/Collector Chamber 2. Sample Port (internal) 3. Sample Port Connection Adaptor (external) 4. Port Valve 5. Sample Container 6. Sample Container Adaptor