ALL-TEST IV PRO Motor Circuit Analyzer

Similar documents
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

APPLICATIONS FOR MOTOR CURRENT SIGNATURE ANALYSIS

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

MIT510/2, MIT520/2 and MIT1020/2

AC-Synchronous Generator

Use your troubleshooting superpowers for good Application Note

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Insulation resistance testing. A complete solution for every person.

SmartVFD HVAC and BYPASS

, User s Manual

Predictive Maintenance

Troubleshooting accelerometer installations

Specifying a Variable Frequency Drive s

DC MOTOR ANALYSIS & TROUBLESHOOTING

Poor quality welds Machine downtime High maintenance costs Lost revenue

C Standard AC Motors

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Voltage Unbalance and Motors

13 common causes of motor failure

Why Buy HVI VLF Products?

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Multi-Function Ground

LC103 ReZolver In-Circuit Capacitor & Inductor Analyzer

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Module Title: Electrotechnology for Mech L7

Intelligent Vibration Monitoring

ABB PSPS Erich Steinmann; Generator control-2013

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Permissible ambient temperature Operation Storage, transport

Troubleshooting with ABS Service Data Kit

Power Capacitor Units for improved power quality

Essential Electrical Concepts

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

PAT Tester Printers and Barcode Scanners

32VFD Variable Frequency Drives for Centrifugal Chillers

Single-Phase AC Synchronous Generator

Welcome to Linear Controls Quarterly Training

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

TIG INVERTER INSTRUCTION MANUAL

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Advanced Systems Tester 900AST

Back-UPS Pro 1300/1500 Installation and Operation

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Diesel Engine Driven Generators Page 1 of 6

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

Lab 14: 3-phase alternator.

EMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Federal Wage System Job Grading Standard for Electrical Equipment Repairing, Table of Contents

Fluke Digital Multimeters Solutions for every need

Physical Specifications (Custom design available.)

On-line PD Monitoring Makes Good Business Sense

Lab 8: DC generators: shunt, series, and compounded.

Table of Contents. TransformerIQ FAQs 1

4 DEDICATED SINGLE PHASE LIMA MAC GENERATOR LIGHT TOWER DUTY MODELS 250MSL1278 AND 250MSL1299 SERVICE PROCEDURE ELECTRICAL COMPONENT TESTING

TROUBLESHOOTING PRELIMINARY

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

46120-F0 Solar Energy Training System

ATS Overhead Table Shelf System INSTRUCTION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Predictive Maintenance in a Mission Critical Environment

Unified requirements for systems with voltages above 1 kv up to 15 kv

Photovoltaic Solar Energy Unit EESFB

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

T Substation Maintenance and Commissioning Test Equipment

Excitation.

User Guide. Model Insulation Tester / Megohmmeter

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Number 1 in efficiency

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

cams Management Systems Technology focused on conserving energy Performance. Period.

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Vibration analysis: what does it mean?

Magnum Mobile Generator MMG55 Specifications

SECTION VARIABLE FREQUENCY DRIVES

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

How To Test For Safety On A Power Cable

User Manual for CH-PFC76810

WIRE AND CABLE ENGINEERING GUIDE

How To Use A Power Supply Unit (Upu)

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

OCSM Series. High Resolution Digital Crane Scale. User Guide

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Fundamentals of Inverter Fed Motors

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Installation and Operation Back-UPS 1250, 1300, 1500

Condition Monitoring of equipment to improve quality of supply to customers by averting failures

Maximizing return on plant assets

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Field-Tested and Fixed in Five!

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Transcription:

ALL-TEST IV PRO Motor Circuit Analyzer PREDICTIVE MAINTENANCE QUALITY CONTROL TROUBLE SHOOTING LOOKING FOR TROUBLE? FIND IT WITH ALL-TEST PRO! Using ALL-TEST Pro Greatly Increases the Profitability of Your Plant! Versatile works on all types and sizes of motors-induction, synchronous, servo, DC and more. Sensitive detects faults at their earliest stages, before motor failure. Detects deep winding faults. Fast testing only takes a few minutes and will give you a complete picture of motor health. Convenient tests can be taken from the motor control center, through hundreds of feet of cable. Easy to use menu driven with on-screen prompts. Expert software provides fault diagnosis plus trending of all data.

Motor Circuit Analysis Applications with The ALL-TEST IV PRO Predictive Maintenance Regular testing can identify developing faults before a failure occurs. All measurement data can be trended for predictive maintenance condition monitoring. By making proactive repairs and eliminating unscheduled down-time, plant productivity is greatly improved. Application Story: A drive failure on a critical 200 HP motor was traced to poor connections using MCA. MCA was performed on 10 similar machines. Five of the machines indicated poorly crimped connections at the motor terminals. These connections would have deteriorated to the point of failure within weeks. Pro-active repairs were performed, cost avoidance of this find was over $500,000. Quality Assurance New motors of any size can be defective. Spares on the shelf are often unknowns. A 2-minute test can insure that your motor will run once you install it! Test new and spare motors before installing (be sure they are good, plus you have a baseline for future comparison) Test motors before you put them on the shelf as spares Test failed motors before and after repairs (make sure you don t have a $900 paint job!) Application Story: A power plant performed a routine test on a new 50 HP motor about to be installed as a back-up bearing coolant pump. A significant phase unbalance was detected, the motor was not installed. Further evaluation revealed that motor was a new design, the unbalance was a manufacturing defect. Had the motor been installed as the backup and been called into service, it would have tripped and failed within minutes. Potential costs would have been in excess of $1 Million. Troubleshooting If the motor system quits running, the ALL-TEST IV PRO evaluates the connections, cable and motor right from the starter, VFD, or disconnect. Takes the guess-work out of determining if you have a Mechanical or Electrical problem. Application story: A 300 HP motor was drawing significantly unbalanced current. Motor Circuit Analysis was performed at the MCC indicating no problems with the motor, cables, or connections. Examination of other components in the circuit identified a blown power factor correction capacitor (The ALL-TEST IV Pro also tests capacitors). The capacitor was much easier and less expensive to replace than the motor. Without the ALL-TEST PRO, this plant would have replaced the motor, only to find the problem was not solved. How much money would this save in your plant? The All-Test IV Pro finds the faults you can t see with any other hand-held instrument. Turn-to-turn, coil-to-coil, and phase-to-phase faults Open phases Burned or contaminated windings Poor connections Broken/cracked rotor bars and rotor casting voids Rotor eccentricity Grounded windings Cable faults Testing spare motors to confirm their status insures against installing a faulty motor. Portable and easy to use, the ALL-TEST IV PRO is right at home on the plant floor. No need for a cart when you re testing motors!

ALL-TEST IV PRO Features Easy To Use An automatic test mode is used for most tests. On screen prompts walk you through the test. In just a few minutes, anyone can learn to use it! On The Spot Diagnosis For Troubleshooting ALL-TEST IV PRO results are immediately displayed for field evaluation. Our quick reference guide helps you make the call on the spot. Answer the mechanical/electrical question immediately, rule the motor in or out. Data Collector With Companion Software For PdM The ALL-TEST IV PRO has enough memory to store 500 tests (more than a day s work). Upload test results to your computer, our software provides expert diagnosis, trending, and a wide variety of printed or on screen reports. Convenient Test From The Motor Control Center Most tests on installed motors are done from the MCC, you can test through over 1000 feet of cable. Even hard to reach motors (overhead cranes, submersible pumps, etc) can be tested quickly and easily. In many cases you do not even need to disconnect from the drive output terminals! No need to test at the motor terminals unless a fault is indicated. Testing the electrical health of a motor/pump combination lets you make a better repair/replace decision. Safe For Operators And Equipment All tests are performed on de-energized circuits. Measurement technology is low voltage and current, and completely nondestructive. Regular and repeated testing will not affect the life of the windings. Quickly Evaluates The Entire Motor Circuit A single 2 minute test evaluates the windings, cabling, and connections. Additional tests let you evaluate the rotor, and capacitors, and cabling to pinpoint the fault. Sensitive Detects motor faults at their earliest stages. Even detects conditions such as deteriorating or contaminated insulation. Light Weight And Hand Held The instrument weighs under 2 lbs, is battery powered and handheld. No need to take a cart when you test a motor. And it can test virtually any size motor. Tests All Kinds Of Motors And Coil Based Devices All types of motors: induction, synchronous, DC, brushless DC, servo, wound rotor, even single phase motors. All Components: induction windings and rotors, DC shunt and field windings, armatures, Field and rotor coils in synchronous motors. Transformers: Single and 3-phase, pole and pad mounted. A 2-minute test from the MCC evaluates the windings, cabling, and connections through even hundreds of feet of cable.

Introduction to Motor Circuit Analysis One of your motors has just stopped running, and your production has stopped. Is the problem mechanical or electrical? Is it the drive? Overload? Load? Connections? Capacitors? Finding the root cause could take hours. And could you have seen it coming? Could you have identified the potential fault in advance, and corrected the issue through scheduled maintenance, and avoided the unplanned shut-down? From the day you install a motor, it is in the process of failing. The only question is when. According to an EPRI study, almost half of all motor failures are electrical in nature (the rest are mechanical). The majority of electrical motor faults start as shorted turns within the windings. In addition, poor connections, winding contamination, and rotor issues all lead to motor failure. Some facts about winding faults: They usually start in the end-turns of the windings where stress is greatest, and the insulation system is the weakest They start small, and escalate over time They sometimes progress to a ground fault They always end in motor failure You can t detect them with a Megohm meter or DMM until the motor has totally failed Motor Circuit Analysis (MCA) MOTOR CIRCUIT ANALYSIS MCA is a technology that lets you examine the electrical health of a motor through measuring multiple electrical properties of the windings. The ALL-TEST IV PRO Motor Circuit Analyzer performs 5 measurements on each of the three winding phases: Winding resistance, impedance, and inductance is measured A low voltage AC signal is applied, and the resulting phase angle is measured A multiple frequency current response test (I/F) is performed Insulation resistance to ground is measured at either 500 or 1000 V In a healthy motor, all of these measurements are balanced. When one or more is out of balance, you have a clear indication of where the fault most likely is. For example if all measurements except resistance are balanced, a loose connection is indicated. Unbalance in the phase angle or I/F test indicates shorted turns within the windings. You can also isolate and identify rotor faults, and eccentricity in assembled motors without run testing under load! Extensive research and field tests have shown that the guidelines for detecting fault conditions are the same on any size and type of device we have successfully evaluated 40,000 HP synchronous machines, tool machine servos, induction motors of all sizes and voltages, and even pad and pole mounted distribution transformers. And you can rely on the results there are virtually no false positives or negatives. Most tests are done from the motor control center, through cable runs of 1000 feet or more. All tests are low voltage and totally non destructive, so there is no danger of damaging sensitive equipment. A test takes less than 3 minutes, and can show you turn, coil, and phase-to-phase faults, open phases, poor connections, contaminated or burned windings, grounded windings and connections or a motor that is perfectly healthy. Once your motor looks like this, it s too late! There is no more powerful instrument for electrical motor evaluation!

Makes it easy to organize and manage motors and test-records Provides trending and diagnostics for 3-phase motors Sets up complete databases for plant and motor nameplate data Interfaces with ALL-TEST IV PRO Gives you built-in report generator TREND is included with the ALL-TEST IV PRO and it is compatible with our flagship software package, EMCAT PRO TREND Trending and diagnostic software for the ALL-TEST IV PRO TREND combines with your ALL-TEST IV PRO to create a powerful tool for troubleshooting and managing 3-phase motors. The database is designed to collect and organize nameplate information of your motors. For a manufacturing site, records can be grouped by building or process; for a service organization, you can group them by customer name and location. Motor Diagnostics for Troubleshooting TREND takes the guesswork out of interpreting test data. It provides a tabular and graphic view of the results, applies proprietary algorithms and automatically diagnoses likely motor faults on the screen. A built in report generator is included for printer output. Motor Trending for Predictive Maintenance For condition monitoring, all measurements can be trend-graphed. Increasing unbalances give you advance notice of deteriorating conditions. Planning for repairs and avoiding unscheduled down-time saves money and aggravation. Scheduling and Review For scheduling purposes, TREND allows you to review motors to be tested by date and then record completed work. You can even record test data from other technologies like infrared. Upgrade from TREND 2003 If you have been using our original TREND 2003 software, you can upgrade to TREND for a nominal fee. All test-data files can be directly imported, analyzed, and trended. Contact the factory for details. Upgradeable to EMCAT PRO Our EMCAT PRO motor management software adds diagnostics and trending for DC motors and Transformers as well as a powerful rotor diagnostic tool. TREND can be easily upgraded to EMCAT PRO. Electric Motor Circuit Analysis Tool (EMCAT PRO Sotware) EMCAT PRO is our flagship software package for motor management. Designed with input from our largest users, it expands on the capabilities of TREND. Expanded diagnostics and trending to include DC motors, transformers, and single-phase motors. Rotor diagnostic module. Modular interface capability with CMMS programs. EMCAT PRO Enterprise network version. EMCAT PRO Rotor Test

Specifications: Resistance: 1 to 999 Ω 1 Impedance: 1 to 999 Ω 2 Inductance: 1 to 9999mH 3 Phase Angle: Current/Frequency Response (I/F): Capacitance: Insulation Resistance: Each ALL-TEST IV PRO includes: Case, Charger, Test Leads, PC Interface Cable, and TREND software. Optional Accessories ATF11 Armature Text Fixture: for bar-to-bar testing of DC motor armatures in disassembled motors. M2000 Training Motor: A 1/3 HP 3-phase motor with known switch-selectable faults. EMCAT PRO Software: Comprehensive software for diagnostics and trending of AC motors, DC Motors, single phase motors, and transformers. ATPRO-115E or - 230E The ALL-TEST PRO Professional System 9-90 degrees (whole number) 0-99% (whole number) 0.2 μf to 200 μf 0.1 to >99 MΩ, 500 and 1000V test voltages Measurement Repeatability: +-1% for all parameters except as noted below Phase Angle- +-1 degree Current/Frequency Response (I/F) +-1 digit Capacitance- +-5% Insulation Resistance- +-5% Test Frequency: 100, 200, 400, 800 Hz Display: 3-line alphanumeric LCD with backlight Size: 4.8 x 9.92 x 2 (122 x 252 x 50 mm) Weight: 1.7 lb/0.75 kg Power: Internal NiMH rechargeable battery pack 1 Auto & Manual mode displays from 0.001 to 999 2 Manual mode displays from 0.001 to 999 3 Manual mode displays from 0.001 to 9999mH Our most comprehensive package for off-line diagnostics and predictive maintenance. It combines the basic troubleshooting and real-time rotor test of the ALL-TEST PRO 31, the analytical and trending power of the ALL-TEST IV PRO, and the motor management capabilities of the EMCAT PRO software. EMCAT PRO software supports AC and DC motors of all types, as well as coils, transformers, and even single phase motors. Used together, these tools deliver unparalleled capability to both new and established predictive, preventive and reliability based maintenance programs. Includes: ALL-TEST IV PRO analyzer, ALL-TEST PRO 31, manuals and guidebooks, leads, chargers, cases, EMCAT PRO software (requires Windows XP or greater), Condition Calculator software, an ATF-11 armature test fixture and an M2000 training motor. ATPOL II ALL-TEST PRO OL II (On-line testing) adds the power of Electrical Signature Analysis and Power Analysis to the Professional System (see above). ALL-TEST Pro, LLC P.O Box 1139 Old Saybrook, CT 06475 Tel 860-399-4222 Fax 860-399-3180 Email info@alltestpro.com Web www.alltestpro.com AT122010 Represented by: Specifications subject to change without notification. All-Test Pro, LLC 2010. All rights reserved.