Flygt 3085, 50Hz. Technical Specification

Similar documents
Flygt 3068, 50Hz. Technical Specification

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Welcome to Grindex Pump handbook! With this handbook we want to share some of our wide experience in pumping with submersible pumps.

Series description: Wilo-Drain TC 40

Flygt N-pump series SelF-cleaNiNg pumps with SuStaiNed high efficiency

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Flygt 2700 series. Corrosion resistant dewatering pumps. 60 Hz

No: En Revision Parts List. MINEX

N-PUMP SERIES FOR MAXIMUM RELIABILITY AND EFFICIENCY IN WASTEWATER HANDLING. Flygt

4" SUBMERSIBLE PUMPS

Pure Performance. Steady 1300 Series

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Godwin NC series Dri-Prime pumps

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

How To Pump A Pump

CRK A-W-A-BUBV

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Project: Model: Chk d: Date: Model 32DGUII61.5S

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Pumps SELECTION OF A PUMP

SIGMA GROUP a. s. Divize průmyslová čerpadla

SJT / SJM / SJP Large Vertical Pumps

ROBOT PUMPS RT - TURBOTEX PUMPS

Submersible pumps Grundfos With top exit Mop sump pomps Simer en City With top exit Submersible pumps Homa Submersible pumps DAB

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

WATER & WASTEWATER. Flygt Submersible Pumps

The conditions below apply to the curves shown on the following pages.

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Flygt Ball Check Valves

Conlift1, Conlift2, Conlift2 ph+

Tsurumi BER. Submersible Ejectors

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

Multistage high-pressure multistage centrifugal pumps

SEG range kw GRUNDFOS WASTEWATER

Vertical Pumps for the Oil & Gas Industry

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

Hydraulic Control Solutions

Horizontal Jet Pumps 1/3-1-1/2 HP

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Vertical selfpriming Side-Channel Pumps Type WPV

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Vogel - Multistage Pumps Design MP, MPA, MPB, MPV Sizes DN 40 - DN 125

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

BS Small Dewatering Pump - Stainless Steel Capacity up to 260 GPM, Heads up to 85 ft. Specifications

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

Transformer oil cooler ALFA A02

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

Dry Pit Solids Handling Pumps

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

PS1800 Centrifugal Pumping Systems

Standard offering (pumps)

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

RUBBER SLEEVE KNIFE GATE VALVE

Solar Hot Water Heaters

General Information. Applications

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

James M. Pleasants Company

Submersible Motor Pump. Amarex N. 50 Hz DN 50 - DN 100. Type Series Booklet

BASIS RANGE TMB SERIES

Model 1210C Battery Powered Pump Shown. Description

VERTICAL TURBINE AND PROPELLER PUMPS

LC/LCD ranges level controllers

MODEL INSTALLATION INSTRUCTIONS

SUBM Electrical Submersible Pumps and Motors

sealed close coupled pumps

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Series description: Wilo-Yonos MAXO

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

SECTION DUCTILE IRON PIPE AND FITTINGS

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

GENIX AUTOMATIC LIFTING STATIONS

3/2-way Solenoid Valve, direct-acting, NC or NO

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

IN series. Centrifugal pumps standardized to DIN-24255

GRUNDFOS INDUSTRY. Grundfos Immersible Pumps

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

OPERATION & MAINTENANCE MANUAL SUBMERSIBLE SEWAGE PUMP

Axial and Mixed Flow Pumps for Large Volume Pumping

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Transcription:

Flygt 3085, 50Hz Technical Specification

Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...7 Product description...7 Motor rating and performance curves...9 F-pump...12 Product description...12 Motor rating and performance curves...14 G-pump...16 Product description...16 Motor rating and performance curves...18 M-pump...19 Product description...19 Motor rating and performance curves...21 N-pump...23 Product description...23 Motor rating and performance curves 3085.160/.190...25 Motor rating and performance curves 3085.183/.092...27 Dimensions and Weight...30 Drawings, C-pump...30 Drawings, D-pump...34 Drawings, F-pump...35 Drawings, G-pump...36 Drawings, M-pump...37 Drawings, N-pump...38 Flygt 3085, 50Hz Technical Specification 1

C-pump C-pump Product description Usage Denomination Submersible pump for pumping clean water, surface water and waste water containing solids or fibred material. Type Non explosion proof version Explosion proof version Pressure class Installation types Standard 3085.183 3085.092 MT Medium head F, P, S, T, Z The pump can be used in the following installations: F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. T Vertical permanent, dry well arrangement with flange connection to suction and discharge piping. Z Horizontal permanent, dry well arrangement with flange connection to suction and discharge piping. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 30 Code compliance IEC 60034-1 Rated output variation ±10% 2 Flygt 3085, 50Hz Technical Specification

C-pump Feature Description Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% H (180 C, 356 F) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 35B GJL-250 Impeller, alternative 1 Cast iron, gray 35B GJL-250 Impeller, alternative 2 Cast iron, gray 30B GJL-200 Wear ring Bronze C924 CC491K; CC492K Lifting handle Stainless steel AISI 316L 1.4404,1.4432, Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Fluorinated rubber (FPM) 70 IRH Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) 1.4401,1.4404, Table 1: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide 3 Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Flygt 3085, 50Hz Technical Specification 3

C-pump Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Leakage sensor in the oil housing (CLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves Star-delta starting current is 1/3 of Direct on-line starting current. 4 Flygt 3085, 50Hz Technical Specification

C-pump MT WS005001A Table 2: 400 V, 50 Hz, 3 phase Rated power kw hp Curve/Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 0,9 1,2 632 940 2,9 11 0,65 F,P,S 0,9 1,2 634 940 2,9 11 0,65 F,P,S 0,9 1,2 636 940 2,9 11 0,65 F,P,S 1 1,3 436 1455 3,2 23 0,6 T,Z 1 1,3 438 1455 3,2 23 0,6 T,Z 1 1,3 440 1455 3,2 23 0,6 T,Z 1,3 1,7 434 1440 3,6 23 0,68 F,P,S 1,3 1,7 436 1440 3,6 23 0,68 F,P,S 1,3 1,7 438 1440 3,6 23 0,68 F,P,S 1,3 1,7 440 1440 3,6 23 0,68 F,P,S 1,4 1,9 434 1435 3,7 23 0,7 T,Z 1,4 1,9 436 1435 3,7 23 0,7 T,Z 1,4 1,9 438 1435 3,7 23 0,7 T,Z 1,4 1,9 440 1435 3,7 23 0,7 T,Z 2 2,7 432 1400 4,8 23 0,8 F,P,S 2 2,7 434 1400 4,8 23 0,8 F,P,S Installati on Flygt 3085, 50Hz Technical Specification 5

C-pump Rated power kw hp Curve/Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 2 2,7 436 1400 4,8 23 0,8 F,P,S 2 2,7 438 1400 4,8 23 0,8 F,P,S 2 2,7 440 1400 4,8 23 0,8 F,P,S Table 3: 230 V, 50 Hz, 1 phase Rated power kw hp Curve/Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 0,95 1,3 436 1410 7,2 28 0,86 F,P,S 0,95 1,3 438 1410 7,2 28 0,86 F,P,S 0,95 1,3 440 1410 7,2 28 0,86 F,P,S 1,5 2 434 1425 9,4 43 0,9 F,P,S 1,5 2 436 1425 9,4 43 0,9 F,P,S 1,5 2 438 1425 9,4 43 0,9 F,P,S 1,5 2 440 1425 9,4 43 0,9 F,P,S Installati on Installati on 6 Flygt 3085, 50Hz Technical Specification

D-pump D-pump Product description Usage Denomination Submersible pump for pumping liquids containing solids, abrasive media or low volumes at high heads. Type Non explosion proof version Explosion proof version Pressure class Cast iron 3085.183 3085.092 MT Medium head HT High head The pump can be used in the following installations: Installation types P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. P, S Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 30 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Maximum 2% Flygt 3085, 50Hz Technical Specification 7

D-pump Feature Insulation class Description H (180 C, 356 F) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable NSSHÖU../3E+St 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 3x2.5+3x2.5/3E+3x1.5 St Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing, alternative 1 Pump housing, alternative 2 Cast iron, gray 35B GJL-250 Cast iron, gray, 45 HRC 35B GJL-250 Impeller, alternative 1 Cast iron, gray 35B GJL-250 Impeller, alternative 2 Cast iron, gray 30B GJL-200 Impeller, alternative 3 Cast iron, gray 30B GJL-200 Lifting handle Stainless steel AISI 316L 1.4404,1.4432, Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Fluorinated rubber (FPM) 70 IRH Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) 1.4401,1.4404, Table 4: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide 3 Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 8 Flygt 3085, 50Hz Technical Specification

D-pump Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Leakage sensor in the oil housing (CLS) Surface treatment (Epoxy) Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves Star-delta starting current is 1/3 of Direct on-line starting current. Flygt 3085, 50Hz Technical Specification 9

D-pump MT WS005003A Table 5: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 2 2,7 470 1400 4,8 23 0,8 P,S 2 2,7 472 1400 4,8 23 0,8 P,S 2 2,7 474 1400 4,8 23 0,8 P,S 2 2,7 485 1400 4,8 23 0,8 P,S 2 2,7 486 1400 4,8 23 0,8 P,S 2 2,7 487 1400 4,8 23 0,8 P,S Table 6: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 1,5 2 472 1425 9,4 43 0,9 P,S 1,5 2 474 1425 9,4 43 0,9 P,S 1,5 2 486 1425 9,4 43 0,9 P,S 1,5 2 487 1425 9,4 43 0,9 P,S Installatio n Installatio n 10 Flygt 3085, 50Hz Technical Specification

D-pump HT WS005004A Table 7: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 2,4 3,2 276 2845 4,8 29 0,9 P,S 2,4 3,2 278 2845 4,8 29 0,9 P,S Installatio n Flygt 3085, 50Hz Technical Specification 11

F-pump F-pump Product description Usage Denomination Submersible pump for pumping liquid manure, or heavily contaminated sewage and sludge. The impeller is S-shaped and fitted with a cutting device. Type Non explosion proof version Explosion proof version Pressure class Cast iron 3085.183 3085.092 LT Low head P, S The pump can be used in the following installations: Installation types P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 30 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% H (180 C, 356 F) 12 Flygt 3085, 50Hz Technical Specification

F-pump Cables Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable NSSHÖU../3E+St 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 3x2.5+3x2.5/3E+3x1.5 St Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 35B GJL-250 Impeller Cast iron, nodular GJS-400-18-LT Suction cover Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Lifting handle Stainless steel AISI 316L 1.4404,1.4432, Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Fluorinated rubber (FPM) 70 IRH Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) 1.4401,1.4404, Table 8: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide 3 Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Flygt 3085, 50Hz Technical Specification 13

F-pump Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Leakage sensor in the oil housing (CLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves LT Star-delta starting current is 1/3 of Direct on-line starting current. WS005005A Table 9: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 2 2,7 490 1400 4,8 23 0,8 P,S 2 2,7 491 1400 4,8 23 0,8 P,S Installatio n 14 Flygt 3085, 50Hz Technical Specification

kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 2 2,7 492 1400 4,8 23 0,8 P,S Table 10: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 1,5 2 492 1425 9,4 43 0,9 P,S F-pump Installatio n Installatio n Flygt 3085, 50Hz Technical Specification 15

G-pump G-pump Product description Usage Denomination A submersible pump designed for pumping raw water. Type Non explosion proof version Explosion proof version Pressure class Standard 3085.183 3085.092 MT Medium head F The pump can be used in the following installations: Installation types F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. Application Limits Feature Liquid temperature Depth of immersion Description Maximum 40 C, (104 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 30 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% H (180 C, 356 F) 16 Flygt 3085, 50Hz Technical Specification

G-pump Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable NSSHÖU../3E+St 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 3x2.5+3x2.5/3E+3x1.5 St Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 35B GJL-250 Impeller Cast iron, gray 35B GJL-250 Strainer bottom Stainless steel AISI 304 1.4301 Cutter plate Steel, stainless steel Lifting handle Stainless steel AISI 316L 1.4404,1.4432, Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti O-rings Nitrile rubber (NBR) 70 IRH Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) 1.4401,1.4404, Table 11: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide 3 Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. Options Leakage sensor in the oil housing (CLS) Leakage sensor in the stator housing (FLS) Flygt 3085, 50Hz Technical Specification 17

G-pump Surface treatment (Epoxy) Other cables Accessories Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves MT Star-delta starting current is 1/3 of Direct on-line starting current. WS005006A Table 12: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 0,77 1 242 2775 1,7 7,5 0,9 F 0,77 1 244 2775 1,7 7,5 0,9 F Table 13: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 0,77 1 242 2785 3 13 0,9 F 0,77 1 244 2785 3 13 0,9 F Installation Installation 18 Flygt 3085, 50Hz Technical Specification

M-pump M-pump Product description Usage Denomination Submersible pump for pumping waste water containing solids that need to be macerated. The impeller is equipped with a grinder device. Type Non explosion proof version Explosion proof version Pressure class Cast iron 3085.172 3085.891 HT High head F, H, P The pump can be used in the following installations: Installation types F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. H Semi permanent, wet well quick connection suspended arrangement, incorporating integral non-return valve. P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. Application Limits Feature Liquid temperature Depth of immersion Description Maximum 40 C, (104 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Starting method Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Direct on-line Star-delta Number of starts per hour Maximum 30 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Maximum 2% Flygt 3085, 50Hz Technical Specification 19

M-pump Feature Insulation class Description H (180 C, 356 F) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable NSSHÖU../3E+St 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 3x2.5+3x2.5/3E+3x1.5 St Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 35B GJL-250 Impeller Cast iron, gray 30B GJL-200 Cutter wheel Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Cutter plate Steel, stainless steel Lifting handle Stainless steel AISI 316L 1.4404,1.4432, Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti O-rings Nitrile rubber (NBR) 70 IRH Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) 1.4401,1.4404, Table 14: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide Surface Treatment Priming Painted with a primer, see internal standard M0700.00.0002 Finish Navy gray color NCS 5804-B07G. Two-component highsolid top coating, see internal standard M0700.00.0004 for standard painting and M0700.00.0008 for special painting. 20 Flygt 3085, 50Hz Technical Specification

M-pump Options Accessories Leakage sensor in the stator housing (FLS) Leakage sensor in the oil housing (CLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves HT Star-delta starting current is 1/3 of Direct on-line starting current. WS005007A Table 15: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ Installatio n 2,4 3,2 250 2845 4,8 29 0,9 F,H,P 2,4 3,2 253 2845 4,8 29 0,9 F,H,P 2,4 3,2 254 2845 4,8 29 0,9 F,H,P 2,4 3,2 259 2845 4,8 29 0,9 F,H,P Flygt 3085, 50Hz Technical Specification 21

M-pump kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ Installatio n 1,8 2,4 254 2890 3,6 29 0,87 F,H,P 1,8 2,4 259 2890 3,6 29 0,87 F,H,P Table 16: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ Installatio n 1,9 2,5 249 2915 12 61 0,87 F,H,P 1,9 2,5 254 2915 12 61 0,87 F,H,P 22 Flygt 3085, 50Hz Technical Specification

N-pump N-pump Product description Usage Denomination The submersible pump is designed for pumping clean water, surface water, and wastewater containing solids or long-fibred material. Type Non explosion proof version Explosion proof version Pressure class Adaptive 3085.160 3085.190 MT Medium head Cast iron 3085.183 3085.092 SH Super head Curve 460, 461, 463, and 253 256 Installation types F, P, S, T, Z Hard-Iron Curve 464, 465, 466 3085.183 3085.092 MT Medium head The pump can be used in the following installations: F Free standing semi permanent, wet well arrangement where the pump is placed on a firm surface. P Semi permanent, wet well arrangement with pump installed on two guide bars with automatic connection to discharge. S Portable semi permanent, wet well arrangement with hose coupling or flange for connection to discharge pipeline. T Vertical permanent, dry well arrangement with flange connection to suction and discharge piping. Z Horizontal permanent, dry well arrangement with flange connection to suction and discharge piping. Application Limits Feature Liquid temperature Liquid temperature, warm water version Depth of immersion Description Maximum 40 C, (104 F) Maximum 70 C, (158 F) Maximum 20 m (65 ft) ph of the pumped liquid 5.5 14 Liquid density Maximum 1100 kg/m 3 Motor data Feature Motor type Frequency Power supply Description Squirrel-cage induction motor 50 Hz 1-phase or 3-phase Flygt 3085, 50Hz Technical Specification 23

N-pump Feature Starting method Description Direct on-line Star-delta Number of starts per hour Maximum 30 Code compliance IEC 60034-1 Rated output variation ±10% Voltage variation Continuously running: Maximum ±5% Intermittent running: Maximum ±10% Voltage imbalance between phases Insulation class Maximum 2% H (180 C, 356 F) Cables Application Type Denomination Direct-on-line start Y/D start SUBCAB heavy-duty submersible cable SUBCAB heavy-duty submersible cable 4G1.5 mm 2 4G1.5+2 1.5 mm 2 4G2.5 mm 2 4G2.5+2 1.5 mm 2 7G2.5 mm 2 Monitoring Equipment Thermal contacts opening temperature 125 C (257 F) Materials Denomination Material ASTM EN Major castings Cast iron, gray 35B GJL-250 Pump housing Cast iron, gray 35B GJL-250 Impeller, alternative 1 Cast iron, gray 35B GJL-250 Impeller, alternative 2 Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Insert ring, alternative 1 Insert ring, alternative 2 Cast iron, gray 35B GJL-250 Cast iron, Hard-Iron A 532 IIIA GJN-HB555(XCR23) Lifting handle Stainless steel AISI 316L 1.4404,1.4432, Shaft Stainless steel AISI 431 1.4057+QT800 Screws and nuts Stainless steel, A4 AISI 316L, 316, 316Ti O-rings, alternative 1 Nitrile rubber (NBR) 70 IRH O-rings, alternative 2 Fluorinated rubber (FPM) 70 IRH 1.4401,1.4404, 24 Flygt 3085, 50Hz Technical Specification

N-pump Denomination Material ASTM EN Oil, part no 901752 Medical white oil of paraffin type. Fulfills FDA 172.878 (a) Table 17: Mechanical face seals Alternative Inner seal Outer seal 1 Carbon/ Aluminum oxide Corrosion resistant cemented carbide/ Corrosion resistant cemented carbide 2 Carbon/ Aluminum oxide Silicon carbide/ Silicon carbide Surface Treatment All cast parts are primed with a water-borne primer. The finishing coat is a high-solid two pack paint. Options Accessories Warm liquid version (non-explosion proof versions) Leakage sensor in the stator housing (FLS) Leakage sensor in the oil housing (CLS) Surface treatment (Epoxy) Zinc anodes Other cables Discharge connections, adapters, hose connections, and other mechanical accessories. Electrical accessories such as pump controller, control panels, starters, monitoring relays, cables. Motor rating and performance curves 3085.160/.190 Star-delta starting current is 1/3 of Direct on-line starting current. Flygt 3085, 50Hz Technical Specification 25

N-pump MT P 2 [kw] P 2 [kw] 2.5 2.0 1.5 1.0 463 462 461 460 1.6 1.4 1.2 1.0 0.8 463 462 H [m] H [m] 10 MT 7 MT 6 8 5 6 4 4 3 2 463 462 461 460 2 1 463 462 0 0 5 10 15 20 25 30 35 Q [l/s] 0 0 5 10 15 20 25 30 Q [l/s] Figure 1: 3 phase WS005022A Figure 2: 1 phase WS004116A Table 18: 400 V, 50 Hz, 3 phase Rated power kw hp Curve/Impeller No Revolutio ns per minute, rpm Rated current, A Starting Power factor, cos φ 1 1,3 463 1455 3,2 23 0,6 T,Z 1,3 1,7 462 1440 3,6 23 0,68 F,P,S 1,3 1,7 463 1440 3,6 23 0,68 F,P,S 1,4 1,9 462 1435 3,7 23 0,7 T,Z 1,4 1,9 463 1435 3,7 23 0,7 T,Z 2 2,7 460 1400 4,8 23 0,8 F,P,S 2 2,7 461 1400 4,8 23 0,8 F,P,S 2 2,7 462 1400 4,8 23 0,8 F,P,S 2 2,7 463 1400 4,8 23 0,8 F,P,S Table 19: 230 V, 50 Hz, 1 phase Rated power, kw Rated power, hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1.5 2.0 462 1425 9.4 43 0.9 F,P,S 1.5 2.0 463 1425 9.4 43 0.9 F,P,S Installati on Installation 26 Flygt 3085, 50Hz Technical Specification

N-pump SH P 2 [kw] 2.5 2.0 1.5 255 256 253 254 24 H [m] SH 20 16 12 8 4 0 253 255 254 256 0 4 8 12 16 20 Q [l/s] WS004117A Table 20: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 2,4 3,2 253 2845 4,8 29 0,91 P,S 2,4 3,2 254 2845 4,8 29 0,91 P,S 2,4 3,2 255 2845 4,8 29 0,91 P,S 2,4 3,2 256 2845 4,8 29 0,91 P,S 2,4 3,2 253 2870 4,9 34 0,87 P,S 2,4 3,2 254 2870 4,9 34 0,87 P,S 2,4 3,2 255 2870 4,9 34 0,87 P,S 2,4 3,2 256 2870 4,9 34 0,87 P,S Installation Motor rating and performance curves 3085.183/.092 Star-delta starting current is 1/3 of Direct on-line starting current. Flygt 3085, 50Hz Technical Specification 27

N-pump MT P 2 [kw] P 2 [kw] 2.5 2.0 1.5 1.0 0.5 0.0 H [m] 463/466 461/465 461 460/464 1.6 1.4 1.2 1.0 0.8 H [m] 463 461 10 MT 3~ 7 MT 1~ 8 6 5 6 4 4 3 2 463/466 461/465 460/464 2 1 463 461 0 0 5 10 15 20 25 30 35 Q [l/s] WS005008A Figure 3: 3 phase 0 0 5 10 15 20 25 30 Q [l/s] Figure 4: 1 phase WS005009A Table 21: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1 1,3 463 1455 3,2 23 0,6 T,Z 1 1,3 466 1455 3,2 23 0,6 T,Z 1,3 1,7 461 1440 3,6 23 0,68 F,P,S 1,3 1,7 463 1440 3,6 23 0,68 F,P,S 1,3 1,7 465 1440 3,6 23 0,68 F,P,S 1,3 1,7 466 1440 3,6 23 0,68 F,P,S 1,4 1,9 461 1435 3,7 23 0,7 T,Z 1,4 1,9 463 1435 3,7 23 0,7 T,Z 1,4 1,9 465 1435 3,7 23 0,7 T,Z 1,4 1,9 466 1435 3,7 23 0,7 T,Z 2 2,7 460 1415 5,2 27 0,73 F,P,S 2 2,7 461 1415 5,2 27 0,73 F,P,S 2 2,7 463 1415 5,2 27 0,73 F,P,S 2 2,7 464 1415 5,2 27 0,73 F,P,S 2 2,7 465 1415 5,2 27 0,73 F,P,S Installation 28 Flygt 3085, 50Hz Technical Specification

kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 2 2,7 466 1415 5,2 27 0,73 F,P,S Table 22: 230 V, 50 Hz, 1 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 1,5 2 461 1425 9,4 43 0,9 P,S 1,5 2 463 1425 9,4 43 0,9 P,S N-pump Installation Installation SH P 2 [kw] 2.5 2.0 1.5 256 255 254 253 H [m] 24 SH 20 16 12 8 4 0 253 255 254 256 0 4 8 12 16 20 Q [l/s] WS005010A Table 23: 400 V, 50 Hz, 3 phase kw hp Curve/ Impeller No Revolutions per minute, rpm Rated Starting Power factor, cos φ 2,4 3,2 253 2845 4,8 29 0,9 P,S 2,4 3,2 254 2845 4,8 29 0,9 P,S 2,4 3,2 255 2845 4,8 29 0,9 P,S 2,4 3,2 256 2845 4,8 29 0,9 P,S Installation Flygt 3085, 50Hz Technical Specification 29

Dimensions and Weight Dimensions and Weight Drawings, C-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 5: LT, P-installation Figure 6: LT, P-installation 30 Flygt 3085, 50Hz Technical Specification

Dimensions and Weight Figure 7: LT, S-installation Figure 8: LT, S-installation Figure 9: MT, F-installation Figure 10: MT, P-installation Flygt 3085, 50Hz Technical Specification 31

Dimensions and Weight Figure 11: MT, P-installation Figure 12: MT, P-installation Figure 13: MT, S-installation Figure 14: MT, S-installation 32 Flygt 3085, 50Hz Technical Specification

Dimensions and Weight Figure 15: MT, T-installation Figure 16: MT, Z-installation Figure 17: HT, P-installation Figure 18: HT, P-installation Flygt 3085, 50Hz Technical Specification 33

Dimensions and Weight Figure 19: HT, S-installation Drawings, D-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 20: MT, P-installation Figure 21: MT, P-installation 34 Flygt 3085, 50Hz Technical Specification

Dimensions and Weight Figure 22: MT, S-installation Figure 23: MT, S-installation Figure 24: HT, P-installation Figure 25: HT, S-installation Drawings, F-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Flygt 3085, 50Hz Technical Specification 35

Dimensions and Weight Figure 26: J-installation Figure 27: P-installation Figure 28: S-installation Drawings, G-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. 36 Flygt 3085, 50Hz Technical Specification

Dimensions and Weight Figure 29: F-installation Drawings, M-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 30: F-installation Figure 31: H-installation Flygt 3085, 50Hz Technical Specification 37

Dimensions and Weight Figure 32: P-installation Drawings, N-pump All drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Contact your sales representative for more information. All dimensions are in mm. Figure 33: MT, F-installation Figure 34: MT, P-installation 38 Flygt 3085, 50Hz Technical Specification

Dimensions and Weight Figure 35: MT, P-installation Figure 36: MT, P-installation Figure 37: MT, S-installation Figure 38: MT, S-installation Flygt 3085, 50Hz Technical Specification 39

Dimensions and Weight Figure 39: MT, T-installation Figure 40: MT, Z-installation Figure 41: SH, P-installation Figure 42: SH, S-installation 40 Flygt 3085, 50Hz Technical Specification

Xylem zīləm 1) The tissue in plants that brings water upward from the roots 2) A leading global water technology company We're 12,500 people unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com Xylem Water Solutions AB Gesällvägen 33 174 87 Sundbyberg Sweden Tel. +46-8-475 60 00 Fax +46-8-475 69 00 http://tpi.xyleminc.com Visit our Web site for the latest version of this document and more information The original instruction is in English. All non- English instructions are translations of the original instruction. 2012 Xylem Inc. 883448_1.0_en.US_2012-07_TS_3085_50Hz