TECHNICAL DATA. edition of this Technical Data Page.

Similar documents
TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

Quick response concealed horizontal sidewall sprinkler

esfr pendent sprinkler vk510 (k25.2)

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Sprinkler Guards Model C Model D

Model KFR56 Series Quick Response Standard Spray

Viking Residential Sprinkler Installation Guide

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model F1FR Series Quick Response Glass Bulb Sprinklers

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Model/Sprinkler Identification Numbers

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Sprinkler Identification Numbers

TECHNICAL DATA. Dry 122a. November 12, 2013

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

Viking Residential Sprinkler Installation Guide

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

HIGH VELOCITY WATER SPRAY NOZZLE

Extended Coverage Sprinklers

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Sprinkler Identification Numbers (SINs) Technical Data

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

08.08 Vic-Check Valves

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

C I T Y O F S E L M A F I R E D E P A R T M E N T

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Your safety and the safety of others are very important.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Technical Data. Installation

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

Approval Standard for Plastic Suspended Ceiling Panels

Metal Pressfitting Pipe Systems

SECTION PIPE HANGERS AND SUPPORTS

Explosion-Proof Electric Unit Heaters

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

POWERS Controls No. 4 Pneumatic Damper Actuator

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

! WARNING. Before using product, read and understand instructions.

DESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

Stainless Steel Single and Dual Circulation Kits

A99B Series Temperature Sensors

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

James M. Pleasants Company

FOAM CHAMBER MODEL - FC

Select Radiators Installation Guide

PART 1 GENERAL 1.1 SECTION INCLUDES

Automatic Fire Sprinkler Submittal Requirements

CEILING CASSETTE FAN COIL UNIT

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Binks Spray Gun Extensions

EFSN Training i Module Minutes

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Installation Manual DIAPHRAGM WELL TANK

STABITHERM INSTALLATION & SERVICE BOOKLET

Toroidal Conductivity Sensor

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Model 43AP Pneumatic Controller, Style B

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

Office of the State Fire Marshal. Fire Rated Doors

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Installation Instructions

TARIFF CODE and updates standard

Installation Instructions

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

FAIRBANKS NIJHUIS FIRE PUMPS.

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Installation Manual DIAPHRAGM WELL TANK

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

GUE, GUB Junction Boxes

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems

Automatic Fire Sprinkler System Checklist

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

CABINET & ENCLOSURE STANDARD FEATURES MATERIALS APPLICATION N C B C A B I N E T P/N:NCB

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Transcription:

Page 1 of 5 1. DESCRIPTION Viking Intermediate Level In-Rack Sprinklers consist of a water shield installed on specifically listed and/or approved frame style standard and quick response sprinklers equipped with glass bulbs or fusible elements. Refer to Approval Charts 1 and 2 for listings and approvals. They are available in both upright and pendent styles with or without sprinkler guards. Refer to Section 5. ORDERING INSTRUCTIONS. Viking Water Shields protect sprinkler heat-sensing elements from water spray discharging from sprinklers located at a higher elevation. They may be used on in-rack sprinkler systems, under grating, on pilot sprinklers for deluge systems, outdoors as a weather shield, or any other application where water shielding is required. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Classes 2005 and 2020 See the Approval Charts 1 and 2 on pages for sprinklers listed and/or approved as Intermediate Level Sprinklers with water shields.. Specifications: A. Water Shield for Pre-assembled Viking Technical Data may be found on Viking Upright Intermediate Level The Viking Corporation s Web site at Sprinklers (See Figure 1): http://www.vikinggroupinc.com. Dimensions: 2-/4 (70 mm) diameter, The Web site may include a more recent 0.059 (0.91 mm) thick. edition of this Technical Data Page. B. Model E-1 Water Shield for Upright Sprinklers equipped with Model D-1 Guards (See Figure 2 - Top): Dimensions: 4-/8 (112 mm) diameter, 2-1/8 (54 mm), 1/2 (12.7 mm) depth, 0.059 (0.91 mm) thick. Available since 1998. C. Model F-1 Water Shield for Pendent Sprinklers (See Figure - Top): Dimensions: (75 mm) diameter, 0.059 (0.91 mm) thick. Available since 1998. Material Standards: Water Shields: Cold Rolled Steel UNS-G10080. Finish: Clear Chromate over Zinc Plating, or Stainless Steel UNS-S0400 Ordering Information: (Also refer to the current Viking price list.) Upright Intermediate Level Sprinklers (without guards): Upright Intermediate Level Sprinklers shown in Figure 1 are pre-assembled with the water shields factory installed (see note below). Refer to the chart on page 4 for upright sprinklers listed and/or approved with water shields. To order a factory pre-assembled Intermediate Level Upright Sprinkler by part number, use the base part number for the sprinkler selected from the chart on page 4. Add the suffix U after the suffixes for the desired temperature and finish (see current Viking Price Book for temperature and finish suffixes). NOTE: Sprinkler guards are NOT available for use with factory preassembled Intermediate Level Upright Sprinklers. For Upright Intermediate Level Sprinklers with guards, see paragraph below. Upright Intermediate Level Sprinklers (with Model D-1 Sprinkler Guards): For Upright Intermediate Level Sprinklers with guards (Figure 2), the special water shield must be ordered separately and installed in the field. Refer to page 4 for upright sprinklers listed and/ or approved for installation with water shields. Upright Intermediate Level Sprinkler (Factory pre-assembled only) The standard response glass bulb style sprinkler shown above is representative only. Standard response fusible link sprinklers and quick response glass bulb or fusible element style sprinklers are also available as intermediate level sprinklers. Refer to Approval Chart 1 for listings and approvals. Figure 1 Model E-1 Water Shield (Viking Part No. 1026 or Stainless Steel Part No. 14682) for Frame Style Upright Sprinklers with the Model D-1 Sprinkler Guard Order Water Shield Separately. (Field Assembly Required. See Installation Instructions.) Order Sprinkler Guard Separately or Factory Installed. (See Ordering Instructions.) Upright Intermediate Level Sprinkler (with Guard and Water Shield) The standard response sprinkler equipped with a 5 mm glass bulb shown above is representative only. Standard response fusible link sprinklers and quick response sprinklers equipped with glass bulbs or fusible elements are also available as intermediate level sprinklers. Refer to Approval Chart 1 on page 4 for listings and approvals. Figure 2

Page 2 of 5 1. Order the sprinkler using the base part number (plus appropriate suffixes for temperature and finish) for the sprinkler selected from Approval Chart 1 on page 4 (see current Viking Price Book for temperature and finish suffixes). a. To order the sprinkler guard factory installed on the upright sprinkler, add the suffix G. b. To order the Model D-1 Sprinkler Guard separately, order Part No. 1025 or Stainless Steel Part No. 12198 (see pages 1-). 2. Order the upright Model E-1 Water Shield, Viking Part No. 1026 or Stainless Steel Part No. 14682. Pendent Intermediate Level Sprinklers: For pendent Intermediate Level Sprinklers Figure ), the Model F-1 Water Shields and sprinklers must be ordered separately and the water shield must be installed in the field. Refer to page 5 for pendent sprinklers listed and/or approved for installation with water shields. 1. Order the sprinklers using the base part number (plus appropriate suffixes for temperature and finish) for the sprinkler selected from the chart on page 5 (see current Viking Price Book for temperature and finish suffixes). a. For optional sprinkler guards factory installed on the pendent sprinkler, add the suffix G. b. To order the optional Model D-1 Sprinkler Guard separately, order Part No. 1025 or Stainless Steel Part No. 12198 (see pages 1-). 2. Order the Model F-1 Water Shields using the appropriate part number for the thread size required. For ½ NPT, order Part No. 102 or Stainless Steel Part No. 1468. For /4 NPT, order Part No. 1024 or Stainless Steel Part No. 14684. NOTE: Water shields are for use on pendent sprinklers with or without guards. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/B (available since 2000). Model D-1 Sprinkler Guard: Part No. 1025 or Stainless Steel Part No. 12198 (NOT for use with factory pre-assembled Upright Intermediate Level Sprinkler.) (See technical data pages 1-.) Sprinkler Cabinet: Six-head capacity: Part No. 0985A for factory pre-assembled upright intermediate level sprinklers (available since 1977) 4. INSTALLATION Refer to the appropriate sprinkler technical data page for warnings and additional installation instructions. Then install units according to the following. Where sprinkler guards* are used, follow installation steps described on pages 1-. (Note: sprinkler guards* may be ordered factory pre-installed). For pre-assembled Upright Intermediate Level Sprinklers* (see Figure 1): Go to steps 2 and below. * Note: Sprinkler guards are NOT available for pre-assembled Upright Intermediate Level Sprinklers. For Upright Intermediate Level Sprinklers with Guards (see Figure 2): 1. Install the Model E-1 Water Shields for upright sprinklers with Model D-1 Sprinkler Guards. a-1. Position the concave surface of the water shield facing the guard. a-2. Align the x slots in the water shield with the intersecting wires at the top of the guard. a-. Press the water shield down firmly until the shield snaps into place with the flat inside surface of the water shield resting on the top horizontal wire ring of the guard (see Figure 2). 2. Go to steps 2 and below. For Pendent Intermediate Level Sprinklers (see Figure ): 1. Install the Model F-1 Water Shields, threading the pendent sprinklers into the shields. 2. Apply a small amount of pipe-joint compound or tape to the external sprinklers threads only, taking care not to allow a build-up of compound in the sprinkler orifice.. Install the sprinkler on the piping using the special sprinkler wrench designed for the sprinkler used. DO NOT use the water shield or guard to start or thread the sprinkler into the fitting. Model F-1 Water Shield for Pendent Sprinklers For ½ NPT, order Part No. 102 or Stainless Steel Part No. 1468. For /4 NPT, order Part No. 1024 or Stainless Steel Part No. 14684. Order Water Shield and Pendent Sprinkler Separately (Field Assembly Required) For Optional Sprinkler Guard, Order Guard Separately or Factory Installed (See Ordering Instructions.) Pendent Intermediate Level Sprinklers (Water Shield Installed in Field) The standard response glass bulb style sprinkler shown above is representative only. Standard response fusible link sprinklers and quick response glass bulb or fusible element style sprinklers are also available as intermediate level sprinklers. Refer to Approval Chart 2 on page 5 for listings and approvals. Figure

Page of 5 IMPORTANT NOTES Sprinkler guards are NOT available for pre-assembled Upright Intermediate Level Sprinklers. For Upright Intermediate Level Sprinklers with guards (Figure 2), the special water shield must be ordered separately and installed in the field. For pendent Intermediate Level Sprinklers (Figure ), the Model F-1 Water Shields and sprinklers must be ordered separately and the water shield must be installed in the field. Refer to the Approval Charts on pages 4-5 for sprinklers listed and/or approved for installation with water shields. WARNING: Viking products are manufactured and tested to meet the rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will nullify the approval and any guarantee made by The Viking Corporation. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the appropriate sprinkler data page. Viking sprinklers are designed to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. 5. OPERATION Refer to the sprinkler techical data page for the sprinkler model used. Viking Water Shields protect sprinkler heat-sensing elements from water spray discharging from sprinklers located at a higher elevation. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Intermediate Level In-Rack Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Page 4 of 5 Sprinkler Base Part No. 1 SIN Sprinkler Style Approval Chart 1 Upright Intermediate-Level Sprinklers (The following upright sprinklers may be ordered with water shields factory installed.) Listings and Approvals Overall Length Thread Size Orifice Size K-Factor Maximum (Also refer to Important (Sprinkler) Pressure Notes on page.) NPT BSP U.S. metric 2 Inches mm culus 4 FM 5 Standard Response, Glass Bulb Type 12986 VK550 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-/8 60 B1 A1 1826 VK560 Upright /4 -- Large 8.0 115.2 175 psi 2-5/16 59 B1 A1 18268 VK560 Upright 1/2 -- Large 8.0 115.2 175 psi 2-5/16 59 B1 -- Standard Response, Fusible Link Type 1297 VK552 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-/8 60 C1 C1 1825 VK562 Upright /4 -- Large 8.0 115.2 175 psi 2-5/16 59 C1 C1 Quick Response, Glass Bulb Type 12978 VK556 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-5/16 60 B1 B1 12281 VK558 Upright 1/2 -- Standard 5.6 80.6 250 psi 2-1/4 57 B1 -- 18257 VK566 Upright /4 -- Large 8.0 115.2 175 psi 2-5/16 59 B1 B1 Quick Response, Fusible Element Type 12279 VK551 Upright 1/2 -- Standard 5.6 80.6 175 psi 2-5/16 59 D1 -- 18275 VK567 Upright /4 -- Large 8.0 115.2 175 psi 2-5/16 59 D1 D1 Approved Temperature Ratings A - 15 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (9 C), 286 F (141 C), and 60 F (182 C) B - 15 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (9 C), and 286 F (141 C) C - 165 F (74 C), 220 F (104 C), and 286 F (141 C) D - 165 F (74 C), 205 F (96 C), and 280 F (18 C) Approved Finish 1 - Brass Footnotes 1 Base part number is shown. For complete part number, refer to Viking s current price list. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories, Inc. for use in the U.S. and Canada. 5 FM Approved for protection of occupancies described in the FM Global Loss Prevention Data Sheets (including 2-0 and 8-9) and Technical Advisory Bulletins.

Page 5 of 5 Sprinkler Base Part No. 1 SIN Sprinkler Style Approval Chart 2 Pendent Intermediate-Level Sprinklers (The following pendent sprinklers may be installed with water shields. Pendent sprinklers and water shields must be ordered separately and field assembled.) Thread Size Orifice K-Factor Maximum Pressure Overall Length (Sprinkler) Listings and Approvals (Also refer to Important Notes on page.) NPT BSP U.S. metric 2 Inches mm culus 4 FM 5 Standard Response, Glass Bulb Type 12987 VK102 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 B1 A1 18264 VK202 Pendent /4 -- Large 8.0 115.2 175 psi 2-5/16 59 B1 A1 07961 VK56 Pendent /4 -- ELO 11.2 161. 175 psi 2-5/16 58.7 -- E1 14820 VK56 Pendent -- 20 mm ELO 11.2 161. 175 psi 2-5/16 58.7 -- E1 Standard Response, Fusible Link Type 12972 VK110 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 57 C1 C1 18254 VK206 Pendent /4 -- Large 8.0 115.2 175 psi 2-5/16 59 C1 C1 Quick Response, Glass Bulb Type 12979 VK02 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 58 B1 B1 12282 VK17 Pendent 1/2 -- Standard 5.6 80.6 250 psi 2-1/4 58 B1 -- 18258 VK52 Pendent /4 -- Large 8.0 115.2 175 psi 2-/8 60 B1 B1 0877 VK77 Pendent /4 -- ELO 11.2 161. 175 psi 2-5/16 58.7 -- E1 Quick Response, Fusible Element Type 12275 VK0 Pendent 1/2 -- Standard 5.6 80.6 175 psi 2-1/4 58 D1 -- 18274 VK5 Pendent /4 -- Large 8.0 115.2 175 psi 2-/8 60 -- D1 Approved Temperature Ratings A - 15 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (9 C), 286 F (141 C), and 60 F (182 C) B - 15 F (57 C), 155 F (68 C), 175 F (79 C), 200 F (9 C), and 286 F (141 C) C - 165 F (74 C), 220 F (104 C), and 286 F (141 C) D - 165 F (74 C), 205 F (96 C), and 280 F (18 C) E - 155 F (68 C), 175 F (79 C), 200 F (9 C), and 286 F (141 C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking s current price list. Approved Finish 1 - Brass 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories, Inc. for use in the U.S. and Canada. 5 FM Approved for protection of occupancies described in the FM Global Loss Prevention Data Sheets (including 2-0 and 8-9) and Technical Advisory Bulletins. (Revised part numbers, images, and format)