FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

Similar documents
Quick response concealed horizontal sidewall sprinkler

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

esfr pendent sprinkler vk510 (k25.2)

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

Model F1FR Series Quick Response Glass Bulb Sprinklers

Viking Residential Sprinkler Installation Guide

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Model KFR56 Series Quick Response Standard Spray

Model F156 Sprinkler Types. Model F156 Recessed Sprinkler Types. Model F142, F1XLH & F128 Sprinkler Types

Model/Sprinkler Identification Numbers

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Extended Coverage Sprinklers

Viking Residential Sprinkler Installation Guide

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Sprinkler Identification Numbers (SINs) Technical Data

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

IDENTIFICATION BROCHURE FOR Central RESIDENTIAL WET SPRINKLERS

HIGH VELOCITY WATER SPRAY NOZZLE

Sprinkler Guards Model C Model D

TECHNICAL DATA. Dry 122a. November 12, 2013

IDENTIFICATION BROCHURE FOR Central COMMERCIAL WET SPRINKLERS

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

08.08 Vic-Check Valves

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

C I T Y O F S E L M A F I R E D E P A R T M E N T

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Engineering Specifications

4 Posiflow Proportional Solenoid Valves

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

REGULATORS 175/153 Series

Tyco Fire & Building Products is a leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the

Many Products...One Source

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Technical Data. Installation

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

STORED PRESSURE STAINLESS STEEL

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

Powers Controls TH 192 S Single Temperature Room Thermostat

Baumann Way Bronze or Stainless Steel Control Valve

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Screw Plug Immersion Heaters

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING

Terminal Boxes Series 8146

VALVES FOR REFRIGERATING SYSTEMS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Installation Instructions

Steel Fire Sprinkler Pipe

INSPECTION, MAINTENANCE AND RECHARGE SERVICE MANUAL P/N 16303

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Antifreeze Solutions in Residential Fire Sprinkler Systems

Automatic Fire Sprinkler Submittal Requirements

! WARNING. Before using product, read and understand instructions.

ASX7-4-IOM-7 J

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

HL Series - Commercial Heaters Tankless Water Heating Solutions

Accents & Accessories

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

SECTION PIPE HANGERS AND SUPPORTS

PRESSURE REDUCING CONTROL VALVE

1805 Series Relief Valves

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

pvc well casing & drop pipe

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

A99B Series Temperature Sensors

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Explosion-Proof Electric Unit Heaters

FOAM CHAMBER MODEL - FC

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

EFSN Training i Module Minutes

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

AMERICAN SOCIETY OF CERTIFIED ENGINEERING TECHNICIANS

Transcription:

Page 1 of 5 1. DESCRIPTION Viking Freedom Residential Pendent Sprinkler VK468 is a small, thermosensitive, glassbulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 4.9 (70.6 metric ), allows efficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. 2. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW NYC Approved: MEA 89-92-E, Volume 35 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric ) Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 F (-55 C) Overall Length: 2-1/4 (58 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000, Phosphor Bronze UNS-C51000, or Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Polytetrafluoroethylene (PTFE) Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Compression Screw: Brass UNS-C36000 For ENT coated sprinklers: Belleville spring - Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 637 Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 155 F (68 C) = B, 175 F (79 C) = D For example, sprinkler VK468 with a Brass finish and a 155 F (68 C) temperature rating = Part No. 637AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000) B. Wrench for recessed sprinklers: Part No. 577W/B* (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) (Added EU Listing)

Page 2 of 5 *A ½ ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1 diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Bulb Color Ordinary 155 F (68 C) 100 F (38 C) Red Intermediate 175 F (79 C) 150 F (65 C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings 3 : ENT 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. Figure 1: Standard Sprinkler Wrench 10896W/B

Page 3 of 5 Approval Chart Viking VK468, 4.9 K-Factor Residential Pendent Sprinkler For systems designed to NFPA D or NFPA R. For systems designed to NFPA, refer to the design criteria. For Ceiling types refer to NFPA, R or D 20 Editions Sprinkler Base Part Number 1 SIN NPT Thread Size Nominal K-Factor Maximum Water Overall Length Inches mm U.S. metric 2 Working Pressure Inches mm 637 VK468 1/2 15 4.9 70.6 175 psi (12 bar) 2-1/4 58 Max. Coverage Area 4 Ft.X Ft. (m X m) Ordinary Temp Rating (155 F/68 C) Flow 4 GPM (L/min) Pressure 4 PSI (bar) Intermediate Temp Rating (175 F/79 C) Flow 4 GPM (L/min) Pressure 4 PSI (bar) Deflector to Ceiling Installation Type Listings and Approvals 3 5 NYC 6 NSF 8 Minimum Spacing Ft. (m) 12 X 12 (3.7 X 3.7) 14 X 14 (4.3 X 4.3) 16 X 16 (4.9 X 4.9) 18 X 18 (5.5 X 5.5) 20 X 20 (6.1 X 6.1) 17 (64.4) 20 (75.7) 12.0 (0.83) 16.7 (1.15) 17 (64.4) 20 (75.7) 12.0 (0.83) 16.7 (1.15) 1-1/8 to 2 inch Standard surface-mounted escutcheons, the Microfast Model F-1 Adjustable Escutcheon, or recessed with the Micromatic Model E-1, E-2, or E-3 Recessed Escutcheon 7 and 10. Footnote 7. Footnote 7. 8 (2.4) 1 Part number shown is the base part number. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4 For areas of coverage smaller than shown, use the Flow and Pressure for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Flow and Pressure used. 5 Listed by Underwriter s Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 35. 7 Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester 9 8 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). 9 Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon.

Page 4 of 5 Figure 2: Wrench 577W/B for Recessed Sprinkler Figure 3: Sprinkler VK468 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon

Page 5 of 5 Figure 4: Sprinkler VK468 Dimensions with the Model E-1 and E-2 Recessed Escutcheons UL Listing Requirements (C-UL-US-EU): DESIGN CRITERIA (Also refer to the Approval Chart.) When using Viking Residential Pendent Sprinkler VK468 for systems designed to NFPA D or NFPA R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA : The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart for NFPA D and NFPAR applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the design area in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA. Minimum distance between residential sprinklers: 8 ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. (Added EU Listing)