Miniature Circuit-Breaker IEC Series 8562



Similar documents
Series 8146/5-V37 and Series 8150/5-V37

Plug and Socket Devices CES 63 A Series 8579

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Plug and Socket Devices SolConeX 16 A Series 8570

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

R.C.C.B. s two-pole LEXIC

Terminal Boxes Series 8146

Linear Luminaire with LED Series EXLUX 6402/2

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Control and Distribution Boxes made of Stainless Steel Series 8150

Actuator-Sensor-Interface

The complete range of consumer switchboards and switchgear

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Circuit Breakers. Next Generation of Protection Capabilities

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

8146/5 Series Breaker Panelboards

5SV Residual Current Protective Devices

7 Lighting Technology

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Pluggable interface relays CR-P Pcb relays

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Type: DILM9 10(24VDC) Article No.:

Manual motor starter MS116

Type: DILM32 10(24V50HZ) Article No.:

RM4TG20 three-phase network control relay RM4-T - range V

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Manual Motor Starter MS 116 up to 16 A Technical Data

Safety technique. Emergency stop module BO 5988 safemaster

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Redundancy Module QUINT-DIODE/40

How can a charging station for electric vehicles be set up simply and safely?

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Three-phase monitoring relay CM-PFE

A good connection. International approvals.

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

MOTOR PROTECTIVE DEVICES

E-STOP relays, safety gate monitors

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Residual Current Protective Devices

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Thermistor motor protection

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

HERZ-Thermal Actuators

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RY2 miniature industrial relays

Bimetallic Overload Relay Specifications

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Flameproof Audible Signal 115 db (A) Series YA90

Residual current socket 30mA Order No.:

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Tmax MCCBs. Molded case circuit breakers. Tmax

Thyristor-controlled power supplies and battery chargers

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Phone: Fax: Web: info@clrwtr.com

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Technical Data. Dimensions

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Low Voltage Products. Switches Automatic Transfer Switches

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Remote Monitoring and REC 501 Control Unit Product Guide

PSR The compact range Description

Catalog. Modular DIN rail components Installation contactors

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Safety automation solutions

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Technicaldata General

Quick Connect. quick - simple - efficient.

Breaking and protection devices

7 - Phaseo power supplies and transformers

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Inductive sensor NI10-M18-Y1X-H1141

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Transcription:

> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips > Power limitation class 3 www.stahl.de /5 miniature circuit-breakers meet all technical requirements relating to safe and selective tripping. When short-circuits occur, they restrict the load on the installed circuits due to their excellent current limiting and related high breaking capacity and provide a high level of discrimination for lineside fuses. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x 12503E00 WebCode 8562B Components for System Solutions /1

Selection Table MCB 8562 for AC, C-Characteristic Breaking capacity o. of poles Rated operational current Additional options Module width Order number Weight ka mm kg 6 1 pole 1 A without 36 8562/51-1030-010 0.800 2 A without 36 8562/51-1030-020 0.800 3 A without 36 8562/51-1030-030 0.800 4 A without 36 8562/51-1030-040 0.800 6 A without 36 8562/51-1030-060 0.800 10 A without 36 8562/51-1030-100 0.800 16 A without 36 8562/51-1030-160 0.800 20 A without 36 8562/51-1030-200 0.800 1 pole + 1 A without 54 8562/52-5030-010 1.200 2 A without 54 8562/52-5030-020 1.200 2 A Auxiliary 72 8562/53-5034-020 1.500 contact 1 changeover 4 A without 54 8562/52-5030-040 1.200 6 A without 54 8562/52-5030-060 1.200 6 A Auxiliary 72 8562/53-5034-060 1.500 contact 1 changeover 10 A without 54 8562/52-5030-100 1.200 10 A Fault signal, 72 8562/53-5035-100 1.500 1 changeover 16 A without 54 8562/52-5030-160 1.200 2 pole 2 A without 54 8562/52-2030-020 1.200 6 A without 54 8562/52-2030-060 1.200 10 A without 54 8562/52-2030-100 1.200 16 A without 54 8562/52-2030-160 1.200 20 A without 54 8562/52-2030-200 1.200 32 A without 54 8562/52-2030-320 1.200 3 pole 2 A without 72 8562/53-3030-020 1.500 4 A without 72 8562/53-3030-040 1.500 6 A without 72 8562/53-3030-060 1.500 10 A without 72 8562/53-3030-100 1.500 10 A Auxiliary 99 8562/54-3034-100 1.800 contact 1 changeover 16 A without 72 8562/53-3030-160 1.500 20 A without 72 8562/53-3030-200 1.500 25 A without 72 8562/53-3030-250 1.500 32 A without 72 8562/53-3030-320 1.500 3 pole + 10 A without 99 8562/54-4030-100 1.800 16 A without 99 8562/54-4030-160 1.800 32 A without 99 8562/54-4030-320 1.800 10 1 pole + 16 A without 54 8562/52-5040-160 1.200 2 pole 10 A without 54 8562/52-2040-100 1.200 16 A without 54 8562/52-2040-160 1.200 3 pole 32 A without 72 8562/53-3040-320 1.500 3 pole + 32 A without 99 8562/54-4040-320 1.800 other versions and accessories on request /2 Components for System Solutions

Selection Table MCB 8562 for AC, B-Characteristic Breaking capacity o. of poles Rated operational current Additional options Module width Order number Weight ka mm kg 6 1 pole 6 A without 36 8562/51-1010-060 0.800 6 1 pole 10 A without 36 8562/51-1010-100 0.800 6 1 pole 16 A without 36 8562/51-1010-160 0.800 6 1 pole + 6 A without 54 8562/52-5010-060 1.200 6 1 pole + 10 A without 54 8562/52-5010-100 1.200 6 1 pole + 10 A Auxiliary 72 8562/53-5014-100 1.500 contact 1 changeover 6 1 pole + 16 A without 54 8562/52-5010-160 1.200 6 1 pole + 20 A without 54 8562/52-5010-200 1.200 6 2 pole 10 A without 54 8562/52-2010-100 1.200 6 3 pole 16 A without 72 8562/53-3010-160 1.500 6 3 pole 25 A without 72 8562/53-3010-250 1.500 6 3 pole 32 A without 72 8562/53-3010-320 1.500 10 2 pole 16 A without 54 8562/52-2020-160 1.200 10 1 pole + 6 A without 54 8562/52-5020-060 1.200 10 1 pole + 10 A without 54 8562/52-5020-100 1.200 10 3 pole 16 A without 72 8562/53-3020-160 1.500 other versions and accessories on request Miniature Circuit-Breaker 1-pole B-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/51-1...-... 8562/52-1...-... 2/1 07614E00 Supplement / Breaking cpacity AC 6 ka 8562/..-.01.-... 8562/..-.01.-... AC 10 ka 8562/..-.02.-... 8562/..-.02.-... AC / DC 6 ka 8562/..-.15.-... -- UL 10 ka 8562/..-.18.-... 8562/..-.18.-... 1 CO -- 8562/..-...4-... Components for System Solutions /3

Miniature Circuit-Breaker 1-pole C-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/51-1...-... 8562/52-1...-... 2/1 07614E00 Supplement / AC 6 ka 8562/..-.03.-... 8562/..-.03.-... AC 10 ka 8562/..-.04.-... 8562/..-.04.-... AC / DC 6 ka 8562/..-.16.-... -- UL 10 ka 8562/..-.19.-... 8562/..-.19.-... UL 135 % 10 ka 8562/..-.39.-... 8562/..-.39.-... 1 CO -- 8562/..-...4-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Miniature Circuit-Breaker 1-pole D-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/51-1...-... 8562/52-1...-... 2/1 07614E00 Supplement / AC 6 ka 8562/..-.21.-... 8562/..-.21.-... AC 10 ka 8562/..-.22.-... 8562/..-.22.-... UL 10 ka 8562/..-.23.-... 8562/..-.23.-... 1CO -- 8562/..-...4-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 /4 Components for System Solutions

Miniature Circuit-Breaker 1-pole Z-Characteristic Module width Width 36 mm Width 54 mm 1/2 8562/51-1...-... 8562/52-1...-... 2/1 07614E00 Supplement / AC 10 ka 8562/..-.24.-... 8562/..-.24.-... 1CO -- 8562/..-...4-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Miniature Circuit-Breaker 1-pole + B-Characteristic Module width Width 54 mm Width 72 mm 1/2 8562/52-5...-... 8562/53-5...-... 2/1 07613E00 Supplement / AC 6 ka 8562/..-.01.-... 8562/..-.01.-... AC 10 ka 8562/..-.02.-... 8562/..-.02.-... UL 10 ka 8562/..-.18.-... 8562/..-.18.-... Auxiliary contact without 8562/..-...0-.. -- 1 CO -- 8562/..-...4-.. Fault signal 1 CO -- 8562/..-...5-.. Components for System Solutions /5

Miniature Circuit-Breaker 1-pole + C-Characteristic Module width Width 54 mm Width 72 mm 1/2 8562/52-5...-... 8562/53-5...-... 2/1 07613E00 Supplement / AC 6 ka 8562/..-.03.-... 8562/..-.03.-... AC 10 ka 8562/..-.04.-... 8562/..-.04.-... UL 10 ka 8562/..-.19.-... 8562/..-.19.-... UL 135 % 10 ka 8562/..-.39.-... 8562/..-.39.-... Auxiliary contact without 8562/..-...0-.. -- 1 CO -- 8562/..-...4-.. Fault signal 1 CO -- 8562/..-...5-.. current A 0,5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Miniature Circuit-Breaker 1-pole + D-Characteristic Module width 1/2 Width 72 mm 8562/53-5...-... 2/1 07613E00 Supplement / AC 6 ka 8562/..-.21.-... AC 10 ka 8562/..-.22.-... UL 10 ka 8562/..-.23.-... Auxiliary contact without -- 1 CO 8562/..-...4-... Fault signal 1 CO 8562/..-...5-... 0.5 8562/..-...-005 1 8562/..-...-010 2 8562/..-...-020 3 8562/..-...-030 4 8562/..-...-040 6 8562/..-...-060 10 8562/..-...-100 13 8562/..-...-130 16 8562/..-...-160 20 8562/..-...-200 25 8562/..-...-250 32 8562/..-...-320 /6 Components for System Solutions

Miniature Circuit-Breaker 2-pole B-Characteristic Module width Width 54 mm Width 72 mm 1/2 3/4 8562/52-2...-... 8562/53-2...-... 2/1 4/3 07612E00 Supplement / AC 6 ka 8562/..-.01.-... 8562/..-.01.-... AC 10 ka 8562/..-.02.-... 8562/..-.02.-... AC / DC 6 ka 8562/..-.15.-... -- UL 10 ka 8562/..-.18.-... 8562/..-.18.-... 1 CO -- 8562/..-...4-... order spec. -- 8562/..-...9-... current A Miniature Circuit-Breaker 2-pole C-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/52-2...-... 8562/53-2...-... 2/1 4/3 07612E00 Supplement / AC 6 ka 8562/..-.03.-... 8562/..-.03.-... AC 10 ka 8562/..-.04.-... 8562/..-.04.-... AC / DC 6 ka 8562/..-.16.-... -- UL 10 ka 8562/..-.19.-... 8562/..-.19.-... UL 135 % 10 ka 8562/..-.39.-... 8562/..-.39.-... 1 CO -- 8562/..-...4-... order spec. -- 8562/..-...9-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Components for System Solutions /7

Miniature Circuit-Breaker 2-pole D-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/52-2...-... 8562/53-2...-... 2/1 4/3 07612E00 Supplement / AC 6 ka 8562/..-.21.-... 8562/..-.21.-... AC 10 ka 8562/..-.22.-... 8562/..-.22.-... UL 10 ka 8562/..-.23.-... 8562/..-.23.-... 1 CO -- 8562/..-...4-... order spec. -- 8562/..-...9-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Miniature Circuit-Breaker 2-pole Z-Characteristic Module Width Width 54 mm Width 72 mm 1/2 3/4 8562/52-2...-... 8562/53-2...-... 2/1 4/3 07612E00 Supplement / AC 10 ka 8562/..-.24.-... 8562/..-.24.-... 1 CO -- 8562/..-...4-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 /8 Components for System Solutions

Miniature Circuit-Breaker 3-pole B-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/53-3...-... 8562/54-3...-... 2/1 4/3 6/5 07611E00 Supplement / AC 6 ka 8562/..-.01.-... 8562/..-.01.-... AC 10 ka 8562/..-.02.-... 8562/..-.02.-... UL 10 ka 8562/..-.18.-... 8562/..-.18.-... 1 CO -- 8562/..-...4-... 2 CO - 1 CO normal and Fault signal 1 CO -- 8562/..-...6-... Miniature Circuit-Breaker 3-pole C-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/53-3...-... 8562/54-3...-... 2/1 4/3 6/5 07611E00 Supplement / Breaking capacit AC 6 ka 8562/..-.03.-... 8562/..-.03.-... AC 10 ka 8562/..-.04.-... 8562/..-.04.-... UL 10 ka 8562/..-.19.-... 8562/..-.19.-... UL 135 % 10 ka 8562/..-.39.-... 8562/..-.39.-... 1 CO -- 8562/..-...4-... 2 CO - 1 CO normal and fault signal 1 CO -- 8562/..-...6-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Components for System Solutions /9

Miniature Circuit-Breaker 3-pole D-Characteristic Module width Width 72 mm Width 99 mm 1/2 3/4 5/6 8562/53-3...-... 8562/54-3...-... 2/1 4/3 6/5 07611E00 Supplement / AC 6 ka 8562/..-.21.-... 8562/..-.21.-... AC 10 ka 8562/..-.22.-... 8562/..-.22.-... UL 10 ka 8562/..-.23.-... 8562/..-.23.-... 1 CO -- 8562/..-...4-... 2 CO - 1 CO normal and fault signal 1 CO -- 8562/..-...6-... 0.5 8562/..-...-005 8562/..-...-005 1 8562/..-...-010 8562/..-...-010 2 8562/..-...-020 8562/..-...-020 3 8562/..-...-030 8562/..-...-030 4 8562/..-...-040 8562/..-...-040 Miniature Circuit-Breaker 3-pole + B-Characteristic Module width 1/2 3/4 5/6 Width 99 mm 8562/54-4...-... 2/1 4/3 6/5 07610E00 Supplement / AC 10 ka 8562/..-.02.-... UL 10 ka 8562/..-.18.-... Auxiliary contact without 8562/..-...0-... 1 CO 8562/..-...4-... Fault signal 1 CO 8562/..-...5-... 2 CO - 1 CO normal and Fault signal 1 CO 8562/..-...6-... 6 8562/..-...-060 10 8562/..-...-100 13 8562/..-...-130 16 8562/..-...-160 20 8562/..-...-200 25 8562/..-...-250 32 8562/..-...-320 /10 Components for System Solutions

Miniature Circuit-Breaker 3-pole + C-Characteristic Module width 1/2 3/4 5/6 Width 99 mm 8562/54-4...-... 2/1 4/3 07610E00 Supplement / AC 6 ka 8562/..-.03.-... AC 10 ka 8562/..-.04.-... UL 10 ka 8562/..-.19.-... UL 135 % 10 ka 8562/..-.39.-... Auxiliary contact without 8562/..-...0-... 1 CO 8562/..-...4-... Fault signal 1 CO 8562/..-...5-... 2 CO - 1 CO normal and Fault signal 1 CO 8562/..-...6-... Miniature Circuit-Breaker 3-pole + D-Characteristic Module width 1/2 3/4 2/1 4/3 6/5 5/6 6/5 07610E00 0.5 8562/..-...-005 1 8562/..-...-010 2 8562/..-...-020 3 8562/..-...-030 4 8562/..-...-040 6 8562/..-...-060 10 8562/..-...-100 13 8562/..-...-130 16 8562/..-...-160 20 8562/..-...-200 25 8562/..-...-250 32 8562/..-...-320 Width 99 mm 8562/54-4...-... Supplement / AC 6 ka 8562/..-.21.-... AC 10 ka 8562/..-.22.-... UL 10 ka 8562/..-.23.-... Auxiliary contact without 8562/..-...0-... 1 CO 8562/..-...4-... Fault signal 1 CO 8562/..-...5-... 2 CO - 1 CO normal and Fault signal 1 CO 8562/..-...6-... 0.5 8562/..-...-005 1 8562/..-...-010 2 8562/..-...-020 3 8562/..-...-030 4 8562/..-...-040 6 8562/..-...-060 10 8562/..-...-100 13 8562/..-...-130 16 8562/..-...-160 20 8562/..-...-200 25 8562/..-...-250 32 8562/..-...-320 Components for System Solutions /11

Explosion Protection Marking IECEx Ex d e IIC Ex d e I Europe (ATEX) E II 2 G Ex d e IIC Gb E I M 2 Ex d e I Mb Certificates IECEx IECEx PTB 06.0062U Europe (ATEX) PTB 02 ATEX 1049 U Other certificates Belarus (Gospromnadzor) Technical Data Device version AC MCBs AC / DC MCBs o. of poles 1 pole, 1 pole +, 2 pole, 3 pole, 3 pole + 1 pole, 2 pole Electrical data AC MCBs AC / DC MCBs voltage Standard version Standard version AC DC AC 1 pole 230 V 48 V 1 pole + 230 V - - 2 pole 230 / 400 V 110 V 1) 3 pole 230 / 400 V - - 3 pole + 230 / 400 V - - 1) 2 poles in series UL- 1 pole 277 V 2) 60 V 2) 1 pole 230 V 3) 60 V 3) 2 pole 277 / 480 V 2) 125 V 2) 2 pole 230 / 400 V 3) 125 V 3) 3 pole 277 / 480 V 2) 125 V 2) 3 pole 230 / 400 V 3) 125 V 3) 2) acc. to UL 1077 3) acc. to E 60898 DC 1 pole 230 V 220 V 1 pole + - - - - 2 pole 230 / 400 V 220 V 440 V 1) 1) 2 poles in series Minimal Voltage U bmin 12 V AC / DC 12 V AC / DC Maximal Voltage U bmax AC 250 V / 440 V AC 250 V / 440 V DC 53 V / 120 V DC 250 V / 440 V Rated insulation voltage 500 V 500 V current Tripping characteristic B 6... 40 A Tripping characteristic B Tripping characteristic C/D/Z 0.5... 40 A Tripping characteristic C/D Rated frequency 50 / 60 Hz 50 / 60 Hz DC Isolation function yes (IEC/E 60947-2) yes (IEC/E 60947-2) Pulse resistance 6 kv 6 kv Utilization category A (IEC/E 60947-2) A (IEC/E 60947-2) 6... 40 A 0,5... 40 A /12 Components for System Solutions

Technical Data Electrical data Tripping characteristic curves 08903E02 11514E02 Components for System Solutions /13

Technical Data Electrical data Tripping characteristic curves Tripping Z-characteristic curve Selectivity class 3 (IEC/E 60898) 6 ka resp. 10 ka Rated switching capacities AC MCBs Poles Series with 6 ka Series with 10 ka Voltage Current Voltage Current (V) (ka) (V) (ka) AC to IEC/E 60898 1-3 I cn 230 / 240 6 I cn 230 / 240 10 AC to IEC/E 60947-2 1 I cu 240 10 I cu 240 15 1+, I cu 127 30 I cu 127 40 2 240 20 240 30 415 10 415 15 3 I cu 240 20 I cu 240 30 415 10 415 15 DC to IEC/E 60947-2 (Time constante 15 ms) 01546E02 1 I cu / I cs 60 20 I cu / I cs 60 25 2 125 25 125 30 AC / DC MCBs AC to IEC/E 60898 1 I cn 230 6 2 I cn 230 / 400 6 DC to IEC/E 60898 1 I cu / I cs 220 6 2 220 / 440 6 Circuit breaker, current limiting with thermal and magnetic release /14 Components for System Solutions

Technical Data Characteristics Characteristic to IEC/E 60898 Rated current range Loads ormal temperature Thermal overload trip Z B C D 0.5... 32 A 6... 32 A 0.5... 32 A 0.5... 32 A > Semiconductor devices > Elektric heatings > Lighting > Socket outlet circuits > Control circuits e.t.c. > Operating > Operating equipment equipment > Light fitting groups > Motors with > Motors heavy starting > Transformers characteristic e.t.c. e.t.c. 20 C 30 C 30 C 30 C 30 C 1.05... 1.2 I n 1.13... 1.45 I n 1.13... 1.45 I n 1.13... 1,45 I n 1.13... 1.45 I n Thermal overload -- -- -- 1.13... 1.35 I n -- trip 135% UL Magnetic trip 2... 3 I n 3... 5 I n 5... 10 I n 10... 20 I n Components for System Solutions /15

Technical Data Electrical data Response value of short-circuit trip Back-up protection Service life Electrical Mechanical Auxiliary contact Rated working current Ambient Conditions Ambient temperature Correction factors The response value of the short-circuit trip is approximately 40 % higher for DC than for AC at 50 / 60 Hz Fuses must be fitted upstream to protect miniature circuit-breakers against high short-circuit currents in high power networks. These protect the miniature circuit-breakers against short-circuit currents of up to 50 ka. If a short-circuit occurs, both protective devices cut out simultaneously, so that the miniature circuit-breaker is not destroyed and remains fully functional. Following MCBs Type 10 4 switching cycles 2x10 4 switching cycles see circuit diagrams 5 A at 230 V AC 1 A at 60 V DC MCB tripping characteristic Rated operational current I th (A) C, D B, Z B, C, D, Z Preceding fuse type gg Minimal rated operational current (A) 8562/5 1 4 - - - - 2 8 63 3 10 6 20 10 80 10 25 16 16 40 20 20 50 32 100 25 63 40 32 80 50 40 100 50 125-20... + 60 C In case of different temperature range please consider correction factor! Correction factors for ambient temperatures other than 30 C Maximal rated operational current (A) 10889E00 10887E00 10888E00 /16 Components for System Solutions

Technical Data Mechanical data Degree of protection Degree of protection acc. to IEC/E 60529 Connecting terminals IP20 Material Enclosure Epoxy resin Mounting / Installation Terminals Main contacts 1.5... 10 mm 2 clamp terminals Auxilliary contacts 1.5 mm 2 clamp terminals Schematic 1/2 1/2 1/2 3/4 1/2 3/4 5/6 2/1 2/1 2/1 4/3 2/1 4/3 6/5 07614E00 07613E00 07612E00 07611E00 1 pole 1 pole + 2 pole 3 pole 1/2 3/4 5/6 2 2 4 2/1 4/3 6/5 +1 +1-3 07610E00 14628E00 14629E00 3 pole + Universal current +/-, 1 pole Universal current +/-, 2 pole 96 98 06 08 98 08 96 98 06 08 95 05 95 05 95 05 11536E00 07618E00 12218E00 12219E00 Auxiliary contact 1 CO Fault indication contact 1 CO Auxiliary contact 1 O Fault indication contact 1 O Auxiliary contact 1 CO Fault indication contact 1 CO U> U< C2 C1 12220E00 D1 D2 12221E00 Remote trip Undervoltage trip Components for System Solutions /17

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Ø5,50 117 18 117 1,50 R5,50 156 146 156 146 5,50 R5,50 5,50 25 1,50 R2,75 25 36 97,50 18 97,50 54 04733E00 04734E00 MCB 8562/51-... MCB 8562/52-... 18 1 R5,50 117 18 1 R5,50 117 156 146 156 146 5,50 5,50 R5,50 R5,50 5,50 72 18 R2,75 25 97,50 99 1 27 R2,75 25 97,50 04735E00 04736E00 MCB 8562/53-... MCB 8562/54-... We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /18 Components for System Solutions