Measuring Power BJT Electrical Characteristics using the B1505A



Similar documents
802.11ac Power Measurement and Timing Analysis

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E5063A ENA Series Network Analyzer

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Agilent U2000 Series USB Power Sensors

Agilent FieldFox Remote Viewer

Agilent 87421A/87422A Power Supply

Variable Frequency Drive Troubleshooting with U1610A/U1620A

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent 4338B Milliohm Meter

Make Better RMS Measurements with Your DMM

DDR Memory Overview, Development Cycle, and Challenges

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

BD238. Low voltage PNP power transistor. Features. Applications. Description. Low saturation voltage PNP transistor

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PXI and AXIe Modular Instrumentation

TIP31, TIP32 High Power Bipolar Transistor

Agilent Television Power Consumption Testing. Application Note

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

PCI Express 1.0 (2.5 GT/s) Protocol Test

BUX48 High Power Bipolar Transistor

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Features: Characteristic Symbol Rating Unit. Collector-Emitter Voltage V CEO 100 Collector-Base Voltage I C

PXI and AXIe Modular Instrumentation

Agilent 4339B/4349B High Resistance Meters

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

BD241A BD241C. NPN power transistors. Features. Applications. Description. NPN transistors. Audio, general purpose switching and amplifier transistors

Agilent U2000 Series USB Power Sensors

The Next Generation in Automated Oscilloscope Test

BUX48/48A BUV48A/V48AFI

Agilent Automotive Power Window Regulator Testing. Application Note

BC107/ BC108/ BC109 Low Power Bipolar Transistors

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

DATA SHEET PNP SILICON EPITAXIAL TRANSISTOR FOR HIGH-VOLTAGE HIGH-SPEED SWITCHING

ULN2801A, ULN2802A, ULN2803A, ULN2804A

BD135 - BD136 BD139 - BD140

2STBN15D100. Low voltage NPN power Darlington transistor. Features. Application. Description

Evaluating Oscilloscope Bandwidths for Your Application

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

TOSHIBA Transistor Silicon PNP Epitaxial Type (PCT Process) 2SA1020

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

ST High voltage fast-switching NPN power transistor. Features. Applications. Description

TDA4605 CONTROL CIRCUIT FOR SWITCH MODE POWER SUPPLIES USING MOS TRANSISTORS

Agilent EEsof EDA.

Application Note. Double click System tray icon after service started. Click start/continue button

STGW40NC60V N-CHANNEL 50A - 600V - TO-247 Very Fast PowerMESH IGBT

Updating the QIAcube operating software

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

BSP52T1 MEDIUM POWER NPN SILICON SURFACE MOUNT DARLINGTON TRANSISTOR

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Agilent U2000 Series USB Power Sensors

HCF4056B BCD TO 7 SEGMENT DECODER /DRIVER WITH STROBED LATCH FUNCTION

LM833 LOW NOISE DUAL OPERATIONAL AMPLIFIER

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent P940xA/C Solid State PIN Diode Switches

1.5 GHz Active Probe TAP1500 Datasheet

HCF4001B QUAD 2-INPUT NOR GATE

STW34NB20 N-CHANNEL 200V Ω - 34A TO-247 PowerMESH MOSFET

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Agilent E6832A W-CDMA Calibration Application

STP80NF55-08 STB80NF55-08 STB80NF N-CHANNEL 55V Ω - 80A D2PAK/I2PAK/TO-220 STripFET II POWER MOSFET

.OPERATING SUPPLY VOLTAGE UP TO 46 V

Get the benefits of Norgren s unique range of Online services

HCF4081B QUAD 2 INPUT AND GATE

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

STP62NS04Z N-CHANNEL CLAMPED 12.5mΩ - 62A TO-220 FULLY PROTECTED MESH OVERLAY MOSFET

Keysight N6854A Geolocation System. Configuration Guide

TOSHIBA Transistor Silicon NPN Epitaxial Type (PCT Process) 2SC2383

DISCRETE SEMICONDUCTORS DATA SHEET BC856; BC857; BC858

TDA2822 DUAL POWER AMPLIFIER SUPPLY VOLTAGE DOWN TO 3 V LOW CROSSOVER DISTORSION LOW QUIESCENT CURRENT BRIDGE OR STEREO CONFIGURATION

Agilent 8762/3/4A,B,C Coaxial Switches

LM134-LM234 LM334 THREE TERMINAL ADJUSTABLE CURRENT SOURCES. OPERATES from 1V to 40V

LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description

Symbol Parameter Value Unit V DS Drain-source Voltage (V GS =0) 50 V V DGR Drain- gate Voltage (R GS =20kΩ) 50 V

STP6N60FI N - CHANNEL ENHANCEMENT MODE POWER MOS TRANSISTOR

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

L293B L293E PUSH-PULL FOUR CHANNEL DRIVERS. OUTPUT CURRENT 1A PER CHANNEL PEAK OUTPUT CURRENT 2A PER CHANNEL (non repetitive) INHIBIT FACILITY

IV and CV Characterizations of Solar/ Photovoltaic Cells Using the B1500A

Agilent Model Quality Assurance (MQA) Industry Standard SPICE Model Signoff and Acceptance Software

HCF4070B QUAD EXCLUSIVE OR GATE

ULN2001, ULN2002 ULN2003, ULN2004

HCF4010B HEX BUFFER/CONVERTER (NON INVERTING)

The Real Total Cost of Ownership of Your Test Equipment

DATA SHEET. MMBT3904 NPN switching transistor DISCRETE SEMICONDUCTORS. Product data sheet Supersedes data of 2002 Oct Feb 03.

Symbol Parameter Value Unit IAR Avalanche Current, Repetitive or Not-Repetitive

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

DDSL01. Secondary protection for DSL lines. Features. Description

High-Speed Inter Connect (HSIC) Solution

AN438 APPLICATION NOTE SAFETY PRECAUTIONS FOR DEVELOPMENT TOOL TRIAC + MICROCONTROLLER

Agilent OSS access7 Signaling Meter

DATA SHEET. PBSS5540Z 40 V low V CEsat PNP transistor DISCRETE SEMICONDUCTORS. Product data sheet Supersedes data of 2001 Jan Sep 21.

Transcription:

Measuring Power BJT Electrical Characteristics using the B1505A Agilent B1505A Power Device Analyzer/Curve Tracer Application Note Introduction The Agilent B1505A Power Device Analyzer/Curve Tracer is a powerful tool for measuring and characterizing power bipolar junction transistors (BJTs). The B1500A has many advanced features that greatly improve measurement efficiency. The B1505A employs Source/ Measure Unit (SMU) technology and has 40 A and 3 kv sourcing capability. This makes it much easier to apply precise currents and voltages to a device and to perform fast and accurate parameter extraction than is possible with a traditional analog curve tracer. The B1505A can perform accurate capacitance versus voltage (CV) measurement at up to 3 kv of DC bias. The B1505A makes it easy to directly measure BJT data sheet capacitance parameters. EasyEXPERT, the GUI-based software resident on the B1505A, supports the automatic extraction of Power BJT parameters (including the auto-placement of lines and markers), eliminating the need for manual post-measurement adjustments. The B1505A is a powerful replacement for traditional curve-tracers that provides both improved test efficiency and measurement accuracy. This application note explains how the B1505A can measure the typical DC and capacitance parameters of power BJT devices. Typical Power BJT Parameters The DC and capacitance parameters listed in a typical power BJT data or specification sheet are summarized in table 1. The right-most column indicates the B1505A s measurement range for that parameter. Previously, these parameters were only measurable using either a DC test system or a collection of instruments that included a curve tracer, a CV meter and a DC bias source. However, with the introduction of the B1505A, all of these parameters can be measured by a single-box instrument solution.

Table 1. Typical DC and Capacitance parameters of power BJT and the measurement range of the B1505A. Typical power BJT Parameter Symbol Unit Measurement 1 Typical Measurable Range of B1505A Collector Current Ic A Ic-Vce -40 A to 40 A (Minimum 10 fa resolution) 2 DC Current gain hfe Ic-Ib 1 ~ 10000 3 Collector Emitter Sustaining Voltage Collector Emitter Breakdown Voltage VCE(SUS) V(BR)CEO V Ic-Vceo -3,000 V to 3,000 V (Minimum 200 µv resolution) 4 Collector-Emitter Cut-off Current ICEO A Ic-Vceo -8 ma to 8 ma (Minimum 10 fa resoluion) 4 Collector-Base Voltage VCBO V Ic-Vcbo -3,000 V to 3,000 V (Minimum 200 µv resolution) 5 Collector-Base Cut-off Current ICBO A Ic-Vcbo -8 ma to 8 ma (Minimum 10 fa resolution) 4 Emitter-Base Voltage VEBO V Ie-Vebo -20 V to 20 V Emitter Cut-off Current IEBO A Ie-Vebo -1 A to 1 A (Minimum 10 fa resolution) 7 Collector-Emitter Saturation Voltage VCE(sat) V Vce(sat)-Ic -20 V to 20 V Collector-Base Saturation Voltage VBE(sat) V Vce(sat)-Ic -20 V to 20 V Base Emitter ON Voltage VBE(on) V Ic-Vbe -20 V to 20 V Collector-Emitter Voltage (Base-Emitter short) VCES V Ic-Vces -3,000 V to 3,000 V (Minimum 200 μv resolution) 5 Output Capacitance Cob pf C-V Better than 1% at C<10 nf 8 1. Measurement used for extracting the parameter. 2. With two HCSMUs and requires Dual HCSMU Combination Adapter. 3. Rule of thumb (Example (Ic/Ib): 20 A/20 A ~ 1 A/100 µa). 4. HVSMU. Maximum 4 ma at 3 kv, 8 ma at 1,500 V. 5. HVSMU. 6. HPSMU and HCSMU. 2 µv resolution at 2 V range. 7. HPSMU at 20 V range. 8. Max. 3,000 V DC bias with High-voltage Bias T adapter. 2

Typical Power BJT Parameter Measurements Typical power BJT parameters can be measured easily using the B1505A. The following section illustrates how to measure some of the power BJT parameters listed in table 1. Multiple test modes available The B1505A has three available test modes: Application Test, Classic Test and Tracer Test. Each of these test modes has unique capabilities, and the choice of which one to use in a given situation depends upon a variety of factors (including personal preference). The following descriptions briefly highlight the features of each test mode. The Application Test mode includes a library of pre-defined tests that eliminate the need to manually specify most of the instrument parameters for common tests (such as Ic-Vce measurements). The user can perform a measurement through an intuitive fill in the blanks procedure. Measurements are performed and parameters are automatically extracted with just the simple click of the measurement button. The Classic Test mode resembles the user interface of the Agilent 4155/4156 Semiconductor Parameter Analyzers, and users familiar with these popular instruments can easily use Classic Test mode to create measurement setups. Any application not furnished in the Application Test mode library can be performed using Classic Test mode. In fact, Classic Test mode represents the fundamental method of instrument control, and all of the pre-defined application tests included in the Application Test mode libraries internally use the Classic Test mode. The Tracer Test mode emulates an analog curve tracer, allowing parameters to be modified in real time during a measurement using the knob on the B1505A s front panel. This ability to get real-time feedback on device parameters (such as breakdown voltage) while varying a voltage or current input can be invaluable when characterizing or performing a quick check on new or unknown devices. The following measurement examples illustrate power MOSFET parameter extraction using these different test modes. 1. DC Current gain: hfe The hfe-ic Application Test shown in figure 1 measures two parameters: hfe and Vbe. Figure 1(a) shows the GUI-based measurement parameter setup window that includes a schematic detailing the connections between the device terminals and the SMUs. You can begin measuring after specifying the SMU connections and modifying the default measurement parameters as necessary. Sample test results are shown in figure 1(b), with the automatically extracted parameters of 74.8 for hfe and 984 mv for Vbe_On at 8 A collector current shown in the parameters field of the output. As this example shows, the Application Test mode makes performing a complex parameter extraction straightforward and simple. This allows the user to focus on their real objective of making the measurement, and it also eliminates many of the errors associated with creating a test setup from scratch. Agilent has a Power BJT measurement handbook available that explains how to use the B1505A s new and furnished application tests to measure all of the parameters shown in table 1. Extracted Parameters: - hfe: 74.8 at 8 A - Vbe_On: 984 mv (a) Test parameter setup window (b) Test result window Figure 1. hfe-ic and Vbe-Ic measurement example using new hfe-ic Application Test. 3

2. Collector-Emitter voltage: Vce(sat) It is possible to measure the data sheet parameter Vce(sat) using Classic Test mode to sweep the collector current as shown in Figure 2. Figure 2(a) shows one of the Classic Test mode parameter setup windows, and figure 2(b) shows the measurement output. It shows automatically extracted Vce(sat) and Vbe(sat) parameters in the parameters field of the output. As can be seen, the output of Classic Test is the same as that of an application test. This is perfectly logical since all application tests ultimately use the Classic Test mode as their measurement engine. Using Classic Test mode you can perform the same measurements as you can using the Application Test mode, except that in Classic Test mode there is no elaborate GUI like that shown in figure 1(a). Of course, using the EasyEXPERT application test editor, you can create a GUI interface for any Classic Test and thereby convert it into a new application test. Power device characterization is typically performed using pulsed inputs with short pulse widths to eliminate self heating effects. The B1505A s minimum pulse width of 50 µs effectively minimizes self-heating effects and enables the achievement of accurate and stable test results. (a) Test parameter setup window of Classic Test (b) Test result window of Classic Test Extracted Parameters: - Vce_sat: 233 mv - Vbe_On: 997 mv both at lc = 8 A Figure 2. Vce_sat and Vbe_sat measurement example using Vce(sat)-Ic_CT Classic Test. 4

3. Collector characteristics: Ic-Vce Figure 3 shows a measurement that uses the Tracer Test mode to measure Ic-Vce collector characteristics. This example shows how Tracer Test mode s interactive knob sweep capability allows the user to interactively control the maximum voltage in the sweep in real time as the measurement is being made. Knob sweep is especially useful for failure analysis, since the voltages and currents that need to be applied are usually not known before the user begins to make a measurement. Note that figure 3 measurement was made with the power compliance set at 230 W (limit shown in red line) so as to not exceed the maximum power rating of the example device. Tracer Test mode supports unique capabilities that are not available in traditional curve tracers, such as the ability to add markers and lines exactly on the curve and to capture the screen image in a PC-compatible format. In Tracer Test mode, the B1505A also supports a real time data capture feature that saves recent measurement data into a memory buffer. Even if your device is inadvertently damaged or destroyed, this feature allows you to display recorded measurement data right up to the point where the damage occurred. None of the features listed above are available in traditional analog curve tracers, and the combination of them with the B1505A s precision measurement capabilities create a powerful and unique solution for characterizing power devices. Agilent recognizes that one major barrier when switching to a new test system is the cost of the test fixtures. Therefore, the Agilent N1259A High Power Test Fixture for the B1505A supports a test adapter socket module that enables you to use legacy interfaces designed for the Tektronix 370B and 371B curve tracers. Step by Step Measurement Handbook The detail of the test setup and the tips of the measurements with the B1505A for each test specifications listed in table 1 are available as "Step by Step Measurement Handbook for Power BJT by Agilent B1505A" with the new example application test definitions through Agilent web. Visit www.agilent.com/find/b1505a for downloading the measurement handbook. 230 W Power Limit Figure 3. Ic Vce Tracer Test example. 5

www.agilent.com www.agilent.com/find/b1505a Conclusion This application note explains how the B1505A can measure the typical DC and capacitance parameters specified on a commercial power BJT specification or data sheet. The measurement range of the B1505A is up to 3 kv and 40A, and it also supports high-voltage CV measurement with up to 3 kv of DC bias (using the high-voltage bias-t). These capabilities combine with the B1505A s many other data analysis features to create a state-of-the-art tool for power BJT measurement that far surpasses the abilities of a traditional curve tracer. The B1505A s three modes of operation (Application Test mode, Classic Test mode and Tracer Test mode) provide the user with different options for device evaluation for maximum measurement flexibility. The B1505A s N1259A test fixture supports a socket adapter that permits the use of legacy Tek curve tracer test fixtures. More detail on the test setups as well as tips for making measurements with the B1505A for each of the test specifications listed in table 1 are available in Agilent`s free Power BJT measurement handbook, including the test setup files and new sample application test definitions covered in this application note. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices www.agilent.com/quality Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 131 452 0200 For other unlisted countries: www.agilent.com/find/contactus Revised: June 8, 2011 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2011 Published in USA, August 30, 2011 5990-8988EN