Kurz Instruments Inc. 30 March 2010



Similar documents
Kurz MODBUS Client User s Guide

Configuring Serial Terminal Emulation Programs

GEIGER COUNTER "Gamma Check Pro"

MAXREFDES46# Quick Start Guide UG6207; Rev 1; 9/15. Abstract

The Answer to the 14 Most Frequently Asked Modbus Questions

EnerVista TM Viewpoint Monitoring v7.10

Transmitter Interface Program

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Using a USB to Serial adapter and Terminal Emulator in Windows 7 to communicate with a DM101

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Global Monitoring + Support

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

BIODEX. ATOMLAB 500/WIPE TEST COUNTER DATA MANAGER SOFTWARE Version 1.10 (and higher). OPERATION MANUAL

SOF-710 ANIMAL FOOD INTAKE MONITOR

User Manual. Thermo Scientific Orion

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

RFID Logger Software User Manual Rev 1.0

PMS. Energy management and monitoring software. Installation and operation instructions

Modbus Communications for PanelView Terminals

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

SenseLink TM. End-Point Controller. Addendum

PRT3 Printer Module: ASCII Protocol Programming Instructions

CRE Monitor Instructions Manual

UDG1000 Hach PCX2200 Serial Port Input Driver configuration

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

20 Using Scripts. (Programming without Parts) 20-1

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

User Guide. Temperature and Humidity Datalogger. Model 42280

BMV-602 Data Link Manual

microsd Card Functionality

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

ROC Protocol Specifications Manual

GE Measurement & Control

KM Metering Inc. EKM Dash User Manual. EKM Metering Inc. (831)

Sigma Control PC INSIDE. 97 psi 187 F R on load

ModS. SIO. USB analog. computer

S4000TH HART. HART Communication Manual

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

WeatherLink for Emergency Response Teams Addendum

SA-9600 Surface Area Software Manual

ee-quipment.com ee203 RTCM USB Quick-Start Guide

Navigator Software. Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.

Ovation Operator Workstation for Microsoft Windows Operating System Data Sheet

How To Use An Fsm1

CONCEPT1 RS232 COMMUNICATION

GE Security. FHSD Monitor / Web Server user manual

Tera Term Telnet. Introduction

SoundLAB Software Download Software from the Bogen website:

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Job Scheduler User Guide IGSS Version 11.0

IGSS. Interactive Graphical SCADA System. Quick Start Guide

ODBC Client Driver Help Kepware, Inc.

Using SPSS, Chapter 2: Descriptive Statistics

Iridium Satellite Phonebook Tool Version H2PT0901 User Guide v3.2

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

PROMIS Tutorial ASCII Data Collection System

8051 MICROCONTROLLER COURSE

DS2438EVKIT+ Smart Battery Monitor Evaluation Kit

BENCHMARK WIRELINE PRODUCTS AMS Monitor

SNMP Web Management. User s Manual For SNMP Web Card/Box

User Manual MMI , Rev AE March ProLink III. Configuration and Service Tool for Micro Motion and Rosemount Flow Devices

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

SYMETRIX SOLUTIONS: TECH TIP August 2015

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

LMR Plus Electric Fire Pump Controllers Custom Messages

4-Channel Thermometer / Datalogger

User's Guide DylosLogger Software Version 1.6

Monnit Wi-Fi Sensors. Quick Start Guide

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

March Module 3 Processing MOVES Output

Controlling LifeSize Video Systems from the CLI

Sending SMS Messages and s

Model 288B Charge Plate Graphing Software Operators Guide

Fingerprint Time & Attendance. User s Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

PM1122 INT DIGITAL INTERFACE REMOTE

Raptor-CAN User Manual

THUM - Temperature Humidity USB Monitor

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

GT-521S MANUAL. Met One Instruments, Inc 1600 Washington Blvd. Grants Pass, Oregon Telephone Facsimile

Pendragon Forms Industrial

Using the HT1632 for Dot Matrix LED Displays

Maintaining the Content Server

Korosi Monitoring System (KMS) Software Manual

Hydras 3 LT Quick Start

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Instructions on How to Use HyperTerminal to Test Serial Ports ...

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

Application & Quick-Start Guide

To export data formatted for Avery labels -

Nemo 96HD/HD+ MODBUS

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Using HyperTerminal with Agilent General Purpose Instruments

Transcription:

Data Logging Most data logging operations are used during a field calibration process or troubleshooting a process flow or the meter readings. In addition to any historical data recorded via the 4-20 ma interface, the MFT B-Series provides various logged reports and supports four types of digital data logging: 1. Continuous data logging to the USB port, CSV formatted text output (spreadsheets) using an internal timer 2. USB port, ASCII escape commands 3. Modbus command query(s) 4. Internal volatile RAM logging which can be extracted using KzComm For additional information and description of the Log Reports capability of the MFT B-Series Flow Meter and Log Mode, see the Section on Built-In Diagnostics. USB port formatted text The data logging output is a string of comma separated values sent to the USB port (a Windows driver must be installed to use this as a COM port) with all meter summary information on one line. If captured using a remote terminal program, such as Tera Term or HyperTerminal, and saved to a text file, this will import into a spreadsheet like Microsoft Excel for further data manipulation or plotting. The data logging function is normally OFF but can be turned ON in Program Mode as follows: Enter Program Mode, press P, the 654321 access code, and E. Press 2 to invoke the Quick Jump option entry method and select Option #18 for the Data Logging setup menu. The meter will prompt as follows: ENABLE DATA LOG >OFF ^v Change the response to 'ON' by pressing the ^ or v key and press E to accept the selection. Once Data Logging has been turned ON, the meter will prompt for a LOG INTERVAL in seconds. The LOG INTERVAL defines the frequency of data logged to the USB port. Using the numeric keys, type in the number of seconds for the LOG INTERVAL. The minimum log interval is 1 second; the maximum is 32,768 seconds or the equivalent of 9.1 hours. The example below will log data to the USB port every 300 seconds (or every 5 minutes). Press E to accept the value. 360209-D Rev. C B-Series Data Logging D - 1

LOG INTERVAL SEC >300 The LCD screen echo should be turned off using the + key on the remote terminal keyboard when capturing data with the logging feature using the internal timer. This ensures that the data displayed on the local LCD screen is not streamed to the USB port along with the logged data. Example data from the.csv format logging function imported into a MS Excel spreadsheet: The above data was captured with HyperTerminal and saved as a.csv file. This was then opened directly by MS Excel then column labels were added by hand for this illustration. Using HyperTerminal, once you have the basic remote terminal operation working you select the top menu Transfer then the pull down menu item Capture Text as shown here: A pop up window will prompt for a file name which you enter with a.csv extension so it will load directly into a spreadsheet without doing an import conversion. Press the start button and the data sent by the flow meter to the PC s USB port will be saved to a file. 360209-D Rev. C B-Series Data Logging D - 2

To stop the data capture to the file, select Transfer Capture Text Stop, which ends the file capture and closes the file. 360209-D Rev. C B-Series Data Logging D - 3

USB Port ASCII commands The ASCII commands allows for communications with the flow meter using either a custom software program or a terminal emulator program. By using esc commands you can obtain the process data of the meter. The structure of the command string is: <ESC>[command]<CR> where: <ESC> is the escape character 0x1B [command] is one of the commands listed in the Table below <CR> is the carriage return character 0x0D All response values are sent as printable ASCII characters and terminated with <CR><NL> (carriage return character followed by newline character). The following Table shows the valid commands and the value(s) provided by the command. ASCII Command qflow qvel qtemp qmeterid qrppower qrpcurrent qrpres qrptemp qrtcres Description Flow Rate as a floating point value (XXXX.XX) Velocity as a floating point value Temperature as a floating point value Tag Name as a string with up to 13 characters Rp Power as a floating point value Rp Current as a floating point value Rp Resistance as a floating point value Rp Temperature as a floating point value Rtc Resistance as a floating point value qsnumber Meter Serial Number as a string with up to 10 characters qruntime qfunit qmeter1 qai1 qerror qao1 Meter Run Time Counter as an integer value Flow Units as a string with up to 4 characters Comma separated flow meter information: Tag Name, Run Time Counter, Flow with units, Totalized Flow with units, Elapsed Time, Velocity with units, Std Density with units, Flow Area with units, Correction Factor, Filtered Irp, Raw Linearized Output External Analog Input Value (output depends on configuration of Analog Input Channel) Meter s Event Code as a HEX value with 8 characters Analog output channel #1 value as a floating point 360209-D Rev. C B-Series Data Logging D - 4

qao2 qalarm value Analog output channel #2 value as a floating point value Alarm status as an unsigned integer Modbus command query. Data logging from the MFT B-Series flow meter using Modbus is very flexible as you have access to just about all possible data at whatever data rate you want. A full explanation of how to use the Modbus interface and its commands are available in the network communications section of the manual. Internal volatile RAM data logging In support of field service and troubleshooting, there is a continuous logging of the meter s flow, temperature and run time every 10 seconds which is stored in the flow meter s internal memory. There are 20,416 samples for 56+ hours of data. If the power is cycled, this data is lost. The data can be extracted using KzComm then saved in a coma separated value file (.csv) which can then be graphed and analyzed in any spreadsheet program. 360209-D Rev. C B-Series Data Logging D - 5