Influence of Tobacco Additives on the Chemical Composition of Mainstream Smoke - Additional Analysis of Three Tobacco Industry Based Laboratories*



Similar documents
How To Develop A Recipe Card

Benzo[a]pyrene Method Development

Cigarette Variability Task Force: CVAR

File M C2 - Document DE/1 - Page 1/5 TEST REPORT. This document is a translation in the lab of original report M Document DE/2 in french

CORESTA RECOMMENDED METHOD N 72

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

The Facts on Equine Drug Testing

AP 4 - de Roton - Potential changes of TSNA composition in stored tobacco powder : consequences for sample preparation and ground tobacco storage

Pesticide Analysis by Mass Spectrometry

CORESTA RECOMMENDED METHOD Nº 80

Ecology Quality Assurance Glossary

Determination of N-cyclohexyl-diazeniumdioxide (HDO) containing compounds in treated wood using GC-MS

Unit title: Chemical Laboratory Techniques

Chemistry Instrumental Analysis Lecture 1. Chem 4631

Certifying Reference Materials to ISO Guide 34

EN ISO :2005/AC

Methods verification. Transfer of validated methods into laboratories working routine. Dr. Manuela Schulze 1

NUVISAN Pharma Services

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

English version Version Française Deutsche Fassung

EFFECT OF CERTAIN LIQUID FILTER ADDITIVES ON MENTHOL DELIVERY

HEATING FUELS - FATTY ACID METHYL ESTERS (FAME) - REQUIREMENTS AND TEST METHODS STANDARD I.S. EN 14213:2003. Price Code

Performance and advantages of qnmr measurements

Proficiency testing schemes on determination of radioactivity in food and environmental samples organized by the NAEA, Poland

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

B i o s o l u t i o n s

Waters Core Chromatography Training (2 Days)

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Reference Report. Assessment of Analytical Literature

ProteinChip Energy Absorbing Molecules (EAM)

CORESTA RECOMMENDED METHOD Nº 81

ONLINE LAUNCHER. Choose one of the following: RADEON Products. HydraVision. Compliance Information

Standards for Cannabis Testing Laboratories

SAMPLE. Gas Chromatography/Mass Spectrometry Confirmation of Drugs; Approved Guideline Second Edition

Indoor Air Comfort Test Report

1- Monitoring of Industrial Pollution

Tar Yield Nicotine CO Yield

(51) Int Cl.: C08K 5/523 ( ) C08K 5/521 ( ) C08K 5/52 ( ) C08G 64/00 ( )

The laboratory fulfils the requirements for periodic emission measurement according to ČSN P CEN/TS 15675:2009

Maria Belli. (former APAT) IX. Congress of clinical chemistry & laboratory medicine Prague September 2009

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

This document is a preview generated by EVS

Roza Tekstil Fermuar San. ve Tic. A.Ş.

AppNote 6/2003. Analysis of Flavors using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

DRAFT ÖNORM EN ISO 11986

OLIVÉR BÁNHIDI 1. Introduction

Manual stack emission monitoring Performance standard for organisations. Environment Agency November 2011 Version 7.2

PT/EQA STANDARDS AND GUIDELINES: QUALITY AND RELIABILITY OF TEST ITEMS

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

PREHEATING AUTOMATIC DRYING AND PREHEATING STATIONS

Air Sampling for Gases and Vapors. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio

A ROUND-ROBIN TO MEASURE THE DIRECT PIEZOELECTRIC COEFFICIENT USING THE BERLINCOURT METHOD

Vitamin C quantification using reversed-phase ion-pairing HPLC

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Fast Continuous Online Analysis of VOCs in Ambient Air using Agilent 5975T LTM GC/MSD and Markes TD

*EP B1* EP B1 (19) (11) EP B1 (12) EUROPEAN PATENT SPECIFICATION

The Empirical Formula of a Compound

(51) Int Cl.: H04L 29/06 ( ) G06F 9/445 ( ) G06F 13/00 ( )

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Bringing Innovations to Standards AC Analytical Controls by PAC All In One Biodiesel Analyzer

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

Identification of Surfactants by Liquid Chromatography-Mass Spectrometry

The Changing Global Egg Industry

Volume 22 Number 22. C43-A ISBN ISSN Gas Chromatography/Mass Spectrometry (GC/MS) Confirmation of Drugs; Approved Guideline

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

LC-MS/MS for Chromatographers

(51) Int Cl.: H05K 1/02 ( )

CORESTA Study Grant Final Report. Analysis of Variability in Curing Conditions and TSNA within Barns of Dark Air-Cured Tobacco

Tanja Wissik. COTSOES Terminology and Documentation Working Group Meeting, 13 May 2013, Stockholm

Chapter 28: High-Performance Liquid Chromatography (HPLC)

CB Test Certificates

LOGOBOOK GUIDELINES & RULES

Quality of organic legumes prediction of main ingredients and amino acids by Near-Infrared Spectroscopy

Light, robust, versatile

Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015

Smokeless Tobacco and Cancer: Questions and Answers

13C NMR Spectroscopy

Retail Products CHF CHF Reseller Pricelist. September 2006 CHF Enduser Price: CHF (incl.

Procedure for Equipment Calibration and Maintenance

Another way to look at the Project Une autre manière de regarder le projet. Montpellier 23 juin - 4 juillet 2008 Gourlot J.-P.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

Electrospray Ion Trap Mass Spectrometry. Introduction

Optimizing the Post-implementation Monitoring of a LC-MS/MS Method

Analysis of Vegetable Oils by High Performance Liquid Chromatography

smokeless tobacco and cancer: questions and answers

Performance objectives and performance criteria Two sides of the food chain*

EG REACH Information für besonders besorgniserregenden Stoffe der Kandidatenliste

Calibration of flow meters for liquids and gases

HYPO TIROL BANK AG. EUR 5,750,000,000 Debt Issuance Programme (the "Programme")

Transcription:

Beiträge zur Tabakforschung International/Contributions to Tobacco Research Volume 24 @ No. 3 @ November 2010 Short Communication Influence of Tobacco Additives on the Chemical Composition of Mainstream Smoke - Additional Analysis of Three Tobacco Industry Based Laboratories* by Michael Intorp 1, Jutta Pani 2, Martin Blumenstock 3 1 Imperial Tobacco Group, Albert-Einstein-Ring 7, 22761 Hamburg, Germany 2 JTI/Ökolab GmbH., Hasnerstrasse 127, 1160-Vienna, Austria 3 British American Tobacco, Product Centre Europe, Weiherstraße 26, 95448 Bayreuth, Germany SUMMARY Three tobacco industry based laboratories determined selected mainstream components using their established in-house methods. Machine smoking was done according to the ISO smoking regime. The Test cigarettes smoked for this investigation were manufactured with different amounts of added glycerol, cocoa powder and sucrose. Variability between the three laboratories differed clearly for the analyzed smoke components. No overall effects due to the added ingredients on smoke components could be found. The high tar products with the highest lodading of sucrose showed a slight increase in formaldehyde emissions among all three laboratories. [Beitr. Tabakforsch. Int. 24 (2010) 139 144] ZUSAMMENFASSUNG Drei Laboratorien der Zigarettenindustrie bestimmten ausgewählte Hauptstomrauchbestandteile mit Hilfe ihrer in den Häusern etablierten Methoden. Das maschinelle Abrauchen erfolgte entsprechend den ISO-Bedingungen. Die für diese Untersuchung eingesetzten Zigaretten waren mit unterschiedlichem Zusatz von Glycerin, Kakaopulver und Saccharose hergestellt worden. Es wurden deutliche Unterschiede zwischen den beteiligten Laboratorien hinsichtlich der analysierten Rauchkomponenten festgestellt. Es konnten keine allgemeinen Auswirkungen der zugesetzten Stoffe auf die Zusammensetzung des Hauptstomrauches nachgewiesen werden. Zigaretten mit einem höheren Teer -Gehalt und der höchsten Zugabe von Saccharose zeigten einen leichten Anstieg der Formaldehyd-Konzentrationen in allen drei Laboratorien. [Beitr. Tabakforsch. Int. 24 (2010) 139 144] RESUME Trois laboratoires industriels ont quantifié des composés de la fumée principale avec leurs propres méthodes d'analyses en utilisant le régime de fumage ISO. Les cigarettes testées ont été fabriquées avec différentes quantités de glycérine, de poudre de cacao et de saccharose. Pour les composés de la fumée analysés, la variabilité entre les trois laboratoires est clairement différente. L'ajout des ingrédients n'a montré aucun effet sur la concentration de ces composés. Seul l'ajout le plus élevé de saccharose sur les produits donnant des "Tars" importants montre, pour les tous les laboratoires, une légère augmentation dans la production de formaldéhyde. [Beitr. Tabakforsch. Int. 24 (2010) 139 144] INTRODUCTION The following communication contains the results of mainstream smoke analysis of the test cigarettes (test pieces) already described and characterized in the paper of *Received: 10 th March 2010 accepted: 18 th September 2010

Table 1. Methods routinely used by the three laboratories for measuring the analytes under consideration. Parameter Lab 1 Lab 2 Lab 3 1,3-Butadiene Health Canada T-116 (gas phase sampling in cooled impingers followed by GC-MS analysis) (5) a Isoprene Health Canada T-116 (gas phase sampling in cooled impingers followed by GC-MS analysis) Formaldehyde Health Canada T-104 (HPLC- UV detection) (5) Acetaldehyde Health Canada T-104 (HPLC-UV detection) TSNA (NNN, NNK, NAT, NAB) Health Canada T-111 (GC-TEA) Benzo[a]pyrene (5) CORESTA Recommended Method No. 58; GC-MS method (7) In-house method; gas bag sampling followed by GC-FID analysis In-house method; gas bag sampling followed by GC-FID analysis In-house method based on Health Canada T-104 In-house method based on Health Canada T-104 In-house LC-MS/MS method In-house method based on Health Canada T-103 (HPLC fluorescence detection) (5) Health Canada T-116, but GC- Ion trap Health Canada T-116 but GC- Ion trap Health Canada T-104 (HPLC- UV detection) Health Canada T-104 (HPLC- UV detection) CORESTA Recommended Method No. 63; GC-TEA (6) CORESTA Recommended Method No. 58; GC-MS method a GC = Gas chromatography, MS = Mass spectrometry, FID = Flame ionization detector, HPLC = High-perfomance liquid chromatophraphy HAHN and SCHAUB in this issue of Beiträge zur Tabakforschung International (1). The investigation was performed by the three laboratories BAT (Regulatory Analysis Laboratory, Souza Cruz), JTI (Ökolab Vienna), and Reemtsma (Hamburg). For reasons of consistency the analytes measured in this investigation are the same as those selected at the beginning of the project in the study protocol of HAHN and SCHAUB. Machine smoking of the test pieces was carried out according to the ISO smoking regimen (2) as done by HAHN and SCHAUB. ANALYTICAL METHODS The laboratories, which participated in this study are all experienced in the analysis of Hoffmann analytes and all of them are accredited according to ISO 17025 (3) for this group of smoke emissions. They also took part in the comprehensive collaborative study on the determination of Hoffmann analytes, organised by CORESTA s Special Analytes Taskforce in 2006, which was recently published in Beiträge zur Tabakforschung International (4). The three participating laboratories were asked to assess the emissions in the mainstream cigarette smoke of the test cigarettes with the methods routinely used for measuring these analytes. Table 1 gives an overview on the methods applied in each laboratory. For evaluating results the repeatability and reproducibility of a method (8) are of major importance. This kind of data is available for the standardized methods for the determination of benzo[a]pyrene (BaP) and the tobaccospecific nitrosamines (TSNAs). The data are shown in Table 2. RESULTS An independent statistician collected the analytical data and processed the in a non-proprietary way. The results are shown in Figures 1 9 (see pages 142 144). CONCLUSIONS The results found for the individual analytes reflect the situation concerning the availability of International Standard Methods at that time. For the individual TSNA s smoke emission data obtained for these series of test cigarettes, similar levels were detected by all the laboratories for the individual products. The same tendency was observed for BaP measurement results. It should be noted that for TSNA and BaP, International Standard Methods are available as indicated in Table 1. These are CORESTA Recommended Methods (CRM) No. 63 for TSNA and CRM No. 58 for BaP. Increased levels of TSNAs or BaP in smoke were not observed that could have been caused by admixed amounts of the additives examined in the study. In case of 1,3-butadiene the yields determined for the same products differ significantly among the laboratories. This can probably be attributed to the fact that different methods Table 2: Repeatability and reproducibility data. Parameter Method Cigarette Mean (ng/cig) Repeatability Reproducibilty BaP CRM 58 (7) Ky2R4F 7.28 1.27 2.52 NNK CRM 63 (6) Ky2R4F 141.39 15.68 43.88 NNN CRM 63 Ky2R4F 146.01 10.75 32.26 NAT CRM 63 Ky2R4F 143.38 20.38 63.62 NAB CRM 63 Ky2R4F 16.60 5.15 10.70 140

in sampling and measuring had been used. However, even by only evaluating the results within the laboratories neither for the type of ingredient, nor for their applied levels, an increase of butadiene was observed. The isoprene yields are found to be much more comparable among the laboratories and similar trends were seen in terms of ingredients and their amounts applied on the test cigarettes. But in this case too, no effect of added ingredients altering isoprene smoke yields was detected. Further efforts in standardisation of a suitable method are urgently needed to obtain reliable reproducibility and repeatability data for both compounds, permitting to discriminate results obtained for different types of cigarettes sufficiently. In the meantime a CRM for selected volatiles was developed and published (9) however reproducibility and repeatability data are still on the level observed in this study. The carbonyls formaldehyde and acetaldehyde are both determined by measuring their di-nitro-phenyl hydrazones with HPLC-UV or HPLC-DAD (diode array detection), the methodology being based on Health Canada Method T-104. But for both compounds considerable differences in yields were observed between laboratories. Due to the poor reproducibility a carbonyl method, too, would benefit greatly from an internationally acknowledged standardisation process. It can be said, however, that all laboratories demonstrated a slight increase of formaldehyde for the 10 mg tar cigarette with the highest load of sucrose. This observation was not confirmed for the 6 mg tar product. competence of testing and calibration laboratories; ISO, Geneva, Switzerland, 2005. 4. Intorp, M., S. Purkis, M. Whittaker, and W. Wright: Determination of Hoffmann Analytes in Cigarette Mainstream Smoke. The Coresta 2006 Joint Experiment; Beitr. Tabakforsch. Int. 23 (2009) 161 202. 5. Health Canada Methods (Accessed November 2010) ; http://www.hc-sc.gc.ca/hc-ps/tobac-tabac/legislation/r eg/indust/method/index-eng.php#main. 6. CORESTA, Recommended Method No 63: Determination of Tobacco Specific Nitrosamines in Cigarette Mainstream Smoke GC-TEA Method; CORESTA, 2005. 7. CORESTA, Recommended Method No 58: Determination of Benzo[a]pyrene in Cigarette Mainstream Smoke - Gas Chromatography-Mass Spectrometry Method; CORESTA, 2004. 8. International Organization for Standardization (ISO): ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method (ISO 5725-2:1994 including Technical Corrigendum 1:2002); ISO, Geneva, Switzerland, 2002. 9. CORESTA, Recommended Method No 70: Determination of Selected Volatile Organic Compounds in the Mainstream Smoke of Cigarettes - Gas Chromatography-Mass Spectrometry Method, 2010. REFERENCES 1. Hahn, J. and J. Schaub: Influence of Tobacco Additives on the Chemical Composition of Mainstream Smoke. Beitr. Tabakforsch. Int. 24 (2010) 100 116. 2. International Organization for Standardization (ISO): ISO 3308:2000 Routine analytical cigarette-smoking machine - Definitions and standard conditions; ISO, Geneva, Switzerland, 2000. 3. International Organization for Standardization (ISO): ISO/IEC 17025:2005 General requirements for the Corresponding author: Michael Intorp Imperial Tobacco Group Albert-Einstein-Ring 7 22761 Hamburg Germany Michael.Intorp@Reemtsma.de 141

N -Nitrosonornicotine (NNN) Figure 1. N -Nitrosonornicotine (NNN) yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental cigarettes (10 mg, 6 mg nicotine-free dry particulate matter according to ISO smoking regime). Standard deviation (SD) is calculated 4-(Methylnitrosamino)- 1-(3-pyridyl)- 1-butanone (NNK) Figure 2. 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental cigarettes (10 mg, 6 mg nicotine-free dry particulate matter according to ISO smoking regime). Standard deviation (SD) is calculated N -Nitrosoanatabine (NAT) Figure 3. N -Nitrosoanatabine (NAT) yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental cigarettes (10 mg, 6 mg nicotine-free dry particulate matter according to ISO smoking regime). Standard deviation (SD) is calculated 142

N -Nitrosoanabasine (NAB) Figure 4. N -Nitrosoanabasine (NAB) yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental cigarettes (10 mg, 6 mg nicotine-free dry particulate matter according to ISO smoking regime). Standard deviation (SD) is calculated Formaldehyde Figure 5. Formaldehyde yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental Acetaldehyde Figure 6. Acetaldehyde yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental 143

1,3-Butadiene Figure 7. 1,3-Butadiene yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental Isoprene Figure 8. Isoprene yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental Benzo[a]pyrene Figure 9. Benzo[a]pyrene yields in mainstream smoke for different levels of added glycerol, cocoa, and sucrose in two experimental cigarettes (10 mg, 6 mg nicotine-free dry particulate matter according to ISO smoking regime). Standard deviation (SD) is calculated 144