CORESTA RECOMMENDED METHOD Nº 80
|
|
|
- Evan Burke
- 9 years ago
- Views:
Transcription
1 CORESTA RECOMMENDED METHOD Nº 80 USE OF THE PART-FILTER METHOD FOR THE ESTIMATION OF SMOKERS EXPOSURE TO NICOTINE AND NICOTINE-FREE DRY PARTICULATE MATTER (January 2016) 0. INTRODUCTION The CORESTA Smoking Behaviour Sub-Group (TSB) conducted two Part-Filter Method (PFM) ring trials (collaborative studies) involving 12 laboratories from 8 countries in 2011 and 10 laboratories from 10 countries in The objective of the ring trials was to gain a measure of repeatability and reproducibility of the PFM across the participating laboratories and to ascertain whether changes introduced to the protocol resulted in an improved performance. The conclusion of the second ring trial characterized the PFM suitable for a Recommended Method. 1. FIELD OF APPLICATION This Recommended Method is applicable to the estimation of human smoke exposure to nicotine and NFDPM (nicotine-free dry particulate matter, also known as tar) using linear calibration regression equations between mainstream smoke yields and corresponding analytes from part-filter extracts. The method is referred to as the Part-Filter Method (PFM). The cigarettes under investigation must contain a cellulose acetate filter element at the mouthend. The method has been successfully applied to population of smokers smoking cigarettes between 1 and 15 mg ISO NFDPM yields as determined by ISO NORMATIVE REFERENCES ISO 10315:2013 Cigarettes Determination of nicotine in smoke condensates Gas-chromatographic method ISO :1999 Cigarettes Determination of water in smoke condensates Part 1: Gas-chromatographic method ISO 3308:2012 Routine analytical cigarette-smoking machine Definitions and standard conditions ISO 4387:2000 Cigarettes Determination of total and nicotine-free dry particulate matter using a routine analytical smoking machine Automotive Industry Action Group (AIAG) (2010) Measurement Systems Analysis, 4th edition. Chrysler Group LLC, Ford Motor Company and General Motors Supplier Quality Requirements Task Force CORESTA Recommended Method N 9 Determination of Nicotine in Cigarette Filters by Gas Chromatographic Analysis CRM No. 80 January 2016 Page 1/16
2 3. METHOD SUMMARY The cigarettes under investigation are smoked using a routine analytical smoking engine which can be of rotary or linear design. The cigarettes should not be conditioned prior to calibration smoking and must be of the same batch which is distributed to human subjects. It is recommended that cigarettes are taken from freshly opened packs prior to machine smoking. Estimated human exposure to nicotine and NFDPM are determined by constructing linear calibration regression equations. Calibration regressions are generated by determining mainstream nicotine and NFDPM yields against filter tip nicotine and filter tip solanesol from analysis of part-filters. The derived linear regressions are used to estimate human yields from part-filters collected from the subjects, it is necessary to construct regression equations of each cigarette product investigated. Nicotine and water captured on a Cambridge Filter Pad (CFP) are analysed following the general methodology listed in ISO 10315:2013, ISO :1999, ISO 3308:2012 and ISO 4387:2000 (or their equivalents) allowing the calculation of the nicotine and NFDPM yields at each of the smoking regimes used in calibration smoking detailed in this CRM. Immediately following the completion of each smoking regime each cigarette is extinguished intact and the cigarette butt is removed from the smoking machine. The whole smoked filter is then cut either using a purpose made filter cutter or with a blade, the cut filter is now referred to as a part-filter. The analysis for nicotine on in a part-filter is different from the methodology in CRM N 9. The length of each part-filter is then measured with calibrated callipers prior to solvent extraction. Part-filters are extracted in methanol containing an internal standard, followed by gas chromatographic (GC) analysis with flame ionisation detection (FID) and high performance liquid chromatography (HPLC) with UV detection. The suggested internal standard (IS) for nicotine analysis is n-heptadecane, however an equivalent compound may be substituted; the solanesol analysis does not make use of an internal standard. Methanol must be used as the extracting solvent since possible alternatives such as propan-2-ol or ethanol do not extract part-filters with sufficient efficiency. Extracted nicotine from part-filters is used to estimate human nicotine yields whereas solanesol is used to estimate NFDPM yields. However it is also possible to obtain estimated nicotine and estimated NFDPM yields from solanesol and nicotine extracted from part-filters respectively. It is not necessary to complete both solanesol and nicotine analyses on the tip extract solutions, however, nicotine is invariably determined. It is important to appreciate that the method is applicable to carbon-containing filters, however, the part-filter element cut from the whole filter must not contain carbon. This is because the presence of carbon in the portion of the filter which is extracted in TES (tip extraction solution) can interfere with the added Internal Standard (IS). 4. APPARATUS Normal laboratory apparatus, in particular, the glassware should be cleaned, rinsed with deionised water and dried prior to use Analytical balance; capable of reading to 4 decimal places Solvent dispenser system able to deliver 20 ± 0.1 ml of TES Orbital flask shaker capable 160 rpm 5 L volumetric flask for preparation of TES (or similar) CRM No. 80 January 2016 Page 2/16
3 150 ml flat-bottomed flasks 200, 100, 50 and 20 ml amber volumetric flasks and stoppers Calibrated pipettes of suitable volumes Amber GC vials and caps Calibrated digital calipers (for measuring lengths to ± 0.1 mm) Filter cutters or suitable cutting device Gas chromatograph, capable of flame ionisation detection (FID), with a suitable column installed HPLC system with UV detector with data handling software, column heater and auto sampler cooler, with suitable column installed Ultra Sonic Bath (for solubilisation of solanesol) 5. REAGENTS AND SUPPLIES Use only reagents of recognized analytical grade. Reagents specific to each analytical approach are identified as either for nicotine or solanesol analyses Helium GC carrier gas, air for FID detector and hydrogen fuel gas for FID detector (for nicotine analysis) n-heptadecane, minimum purity 99 %, CAS number (IS used in nicotine analysis) Nicotine, minimum purity greater or equal to 99 %, CAS number A further source of nicotine of the same purity but of a different batch can be used to prepare a calibration check standard. (Care must be taken when handling pure nicotine which is a poison, please observe all relevant local safety instructions) Solanesol, purity > 95 % CAS number Propan-2-ol AR Grade, CAS number (for preparation of IS stock solution) Methanol AR Grade, CAS number (for preparation of TES) Methanol, HPLC Grade, CAS number (mobile phase in solanesol analysis) Acetonitrile HPLC Grade, CAS number (mobile phase in solanesol analysis) 6.1 Extracting solution 6. PREPARATION OF STANDARDS AND SOLUTIONS n-heptadecane stock standard Weigh 25.0 ± 0.05 g of n-heptadecane into a 200 ml volumetric flask and dilute to volume with propan-2-ol. Sonicate until dissolved, the solution remains stable for 12 months at room temperature. Tip extraction solution (TES) Add 2 ml of n-heptadecane Stock Standard to 2.5 L methanol (AR grade) in a 5 L volumetric flask and make up to the mark with methanol. Cap and invert several times to ensure thorough mixing before pouring into the dispenser reservoir. This gives an internal standard concentration of approximately 0.05 mg/ml. TES remains stable for 3 months at room temperature. CRM No. 80 January 2016 Page 3/16
4 6.2 Preparation of nicotine standards Amber glassware is used for the preparation and storage of the standards. Nicotine calibration stock standard Weigh g (± g) nicotine into a 200 ml amber volumetric flask and make up to volume with TES. The exact weight of nicotine used is recorded and adjusted for purity. The concentration is then calculated using the adjusted weight as shown below in Equations 1 and 2. This gives a concentration of approximately 2 mg/ml. The nicotine calibration stock standard remains stable for 3 months when stored at 4 C. Equation 1 Calculation for weight of nicotine adjusted for purity = (weight of nicotine (g) / 100) * purity Equation 2 Calculation for nicotine concentration in stock (mg/ml) = (purity adjusted weight of nicotine used (g) * 1000) / volume of stock standard (ml) Nicotine calibration working standards Make the standards up to volume with TES as detailed in Table 1. The standards remain stable for 1 month when stored at 4 C. Table 1 - Preparation of Working Nicotine Standards Stock Standard (ml) Final volume (ml) Nominal concentration (mg/ml) The preparation of an independent nicotine quality check standard is described below. 6.3 Nicotine calibration check stock standard Weigh (± g) nicotine into a 200 ml amber volumetric flask and make up to volume with TES as detailed above for the nicotine calibration stock standard. This gives a nominal concentration of 2 mg/ml. The calibration check stock standard remains stable for one month when stored at 4 C. Nicotine calibration check standard mg/ml Pipette 5 ml of the nicotine calibration check stock standard into a 200 ml amber volumetric flask and make up to the mark with TES. The independent calibration check standard has a nominal concentration of 0.05 mg/ml. The calibration check standard should be run at regular intervals within the analysis sequence, for instance every 10 samples. The acceptance criterion of the calibration check standard is ±10% of its nominal concentration value. CRM No. 80 January 2016 Page 4/16
5 6.4 Preparation of solanesol standards Solanesol calibration stock standard Weigh out ± g solanesol in a weighing boat and quantitatively transfer into an amber 50 ml volumetric flask. Dissolve the solanesol in HPLC grade methanol with the assistance of an ultrasonic bath, then make up to 50 ml with the methanol. Solanesol calibration working standards Prepare calibration standards in amber flasks using calibration stock standard, detailed in Table 2: Table 2 - Preparation of Working Solanesol Standards Stock Standard (ml) Final Volume ( ml) Nominal concentration (µg/ml) Solanesol calibration check standard 15 g/ml The preparation of an independent solanesol quality check standard is described below. Weigh ± g solanesol into a 50 ml amber volumetric flask following the method for the calibration stock. This gives a concentration of 300 µg/ml. Pipette 2.5 ml of this stock standard into a 50 ml amber volumetric flask, make up to the mark with HPLC grade methanol. This calibration check standard will contain 15µg/mL solanesol. All stock solutions, calibration standards and the calibration check standard should be stored in a -20 C freezer. All standard and stock solutions are stable for 2 months when stored at -20 C. The calibration check standard should be run at regular intervals within the analysis sequence, for instance every 10 samples. The acceptance criterion of the solanesol calibration check standard is ±10% of its nominal concentration value. 7.1 Calibration smoking 7. PROCEDURE Calibration smoking must be undertaken at approximately the same time as the human subjects are performing their smoking to ensure similar aging on both sets of tips calibration smoked tips and human smoked tips. Laboratories should construct linear regression calibration equations using the smoking regimes detailed in Table 3. The purpose of machine-smoking cigarettes for calibration is to relate the amount of 'tar' or nicotine that exits the filter to the amount filtered by the tip. This removes the constraints required by standardized smoking methods to obtain an absolute yield at controlled conditions. These constraints include pre-conditioning the cigarettes, smoking CRM No. 80 January 2016 Page 5/16
6 the cigarettes at a controlled temperature and humidity or maintaining a fixed air-flow rate around the cigarettes while smoking (ISO 3308). Therefore, the test cigarettes are smoked according to ISO 3308:2012 with the following exceptions: The smoking machine air flow is not specified The cigarettes are not preconditioned prior to smoking Quarter portions of CFPs are not used to wipe out the CFP holder CFPs are weighed outside of the pad holder as detailed below Table 3 - Calibration Smoking Regimes Smoking Regime Puff Volume Puff Duration Puff Interval CFP diameter Smoked length/puffs Number of cigarettes A 35 ml 2.0 s 60 s 44 mm Over Tipping+3 mm 5 B 60 ml 2.0 s 30 s 44 mm 4 puffs 5 C 60 ml 2.0 s 30 s 44 mm Over Tipping+3 mm 3 D 70 ml 2.0 s 30 s 44 mm Over Tipping+3 mm 3 E 40 ml 2.0 s 30 s 44 mm Over Tipping+3 mm 5 F 70 ml 1.5 s 20 s 44 mm Over Tipping+3 mm 3 0 Unsmoked Blank 5 CFPs are weighed outside the CFP holder 1. To to minimise evaporative losses, the time interval between the removal of the CFP from the holder, the weighing of the CFP and placing the CFP in a sealed vessel is kept to the minimum. CFPs must be extracted soon after smoking and analysed for nicotine and water on the same day as smoking, following ISO 10315:2013, ISO :1999, ISO 3308:2012 and ISO 4387:2000. Three cigarettes are smoked for certain regimes to avoid breakthrough of the smoke condensate. Not all smoking machines are able to perform Regime F, in which case this regime is not run. Following the calculation of total particulate matter (TPM), smoke yields are determined by extracting each CFP in 20 ml pad extraction solution, the preparation of which is detailed in ISO 3308:2012. The measurements of water and nicotine yields are subtracted from the TPM to calculate NFDPM (in mg/cig) at each of the smoking regimes. For Regime 0 nicotine and NFDPM yields are set to zero. The regimes in Table 3 must be repeated on two different days to account for daily variation. 1 CFPs are weighed outside the CFP holder for the following reason: combustion water increases disproportionately to the amount of tar as puff volumes used in calibration smoking are increased resulting in the deposition of moisture in inaccessible parts of the CFP holder which are not incorporated into the extract solution even after wiping with the quartered pad specified in ISO 3308:2012. The under-reporting of water and consequential over-reporting of NFDPM would produce a systematic error in the part-filter method that is avoided by weighing the CFP only which contains the overwhelming proportion of NFDPM emitted from the cigarettes. The weight of the CFP gives the pad TPM which is used to derive the NFDPM after subtracting for water and nicotine. CRM No. 80 January 2016 Page 6/16
7 7.2 Treatment of part-filters The length of part filter cut down stream of ventilation depends on the filter design of the test product. Smoked cigarette whole filters obtained from calibration smoking are usually cut to 10 mm, 7 mm or 5 mm mouth-end portions. Filter segments containing carbon must be excluded from the part-filter. The tips are usually cut using a specially designed filter cutter similar to that shown in Picture Normalisation of part-filter lengths Part-filters from machine and human smoking are normalised with respect to their nominal length. Digital callipers, such as illustrated in Picture 2, measure part-filter lengths to within ±0.1 mm. The mean part-filter length is calculated for each extraction sample of five part-filters (three in the case of smoke regimes C, D and F). The calculation of the normalisation factor is shown in Equation 3. Picture 1: Filter cutter Picture 2: Digital callipers Equation 3 normalisation factor = x / (part-filter lengths) / n Where n is the number of part-filters and x is the nominal part-filter length. The normalisation factor (to 3 decimal places) is applied to tip nicotine measurements as shown in Equation 4. The solanesol analysis is treated similarly. Equation 4 Normalised nicotine (mg/tip) = concentration nicotine (mg/ml) * extraction volume (ml) * normalisation factor / number of tips extracted Extraction of part-filters Once the part-filters are extracted they are referred to as tips. Five part-filters (three in the case of smoke regimes C, D and F) are extracted in 20 ml of TES in a 150 ml round-bottom flask. The extraction is completed on an orbital shaker operating at 160rpm for a minimum of 30 minutes. The resultant solution is vialed and analysed within 8 days (stored at +4 C) for nicotine or solanesol. Human smoked tips must be analysed alongside the smoked calibration tips to ensure consistency with calibration smoking. It is important that part-filters are not exposed to prolonged high temperature conditions during shipping which may result in loss of nicotine by evaporation. Part-filters (calibration and human tips) may be frozen and stored CRM No. 80 January 2016 Page 7/16
8 CFP Nicotine Yield (mg/cig) Tip Solanesol ( g/tip) indefinitely, however, both sets of part-filters need to be treated the same. Tips are usually stored and shipped in screw top aluminium tins, example shown in Picture 3 and a set of smoked tips is shown in Picture 4. Any human tips which are contaminated, for instance contain lipstick staining, must be removed from the analysis set. Part-filters should be allowed to reach ambient temperature prior to length measurement. Picture 3: Aluminium tin Picture 4: Set of smoked part-filters Analysis In both nicotine and solanesol analyses calibration standards should be analysed at the start of the run, followed by the samples with a calibration check standard placed after every ten samples. Regime 0 provides blank tips to be analysed for tip nicotine and tip solanesol. The quantities measured in these tips will be low, however, it is important to include them in the calibration graphs. A quality control chart is constructed by plotting CFP nicotine against CFP NFDPM yields (12 data points Regime 0 not included), example depicted in Figure 1. Smoking linearity is demonstrated if the square of the linear coefficient of determination, R 2, is greater than Failure to achieve linearity is most often caused by smoking engine errors. If solanesol analysis is also undertaken, it is advisable to construct a tip quality control chart by plotting tip solanesol against tip nicotine (14 data points Regime 0 included), example depicted in Figure 2. Linearity is demonstrated if the square of the linear correlation coefficient, R 2, is greater than Failure to achieve linearity here is most often ascribed to errors in the analytical methods y = 0.093x R² = y = x R² = NFDPM Yield (mg/cig) Tip Nicotine (mg/tip) Figure 1: Smoke quality control chart Figure 2: Tip quality control chart CRM No. 80 January 2016 Page 8/16
9 CFP Nicotine Yield (mg/cig) NFDPM Yield (mg/cig) The nicotine calibration graph is produced by plotting CFP nicotine yield against tip nicotine (14 data points Regime 0 included), example depicted in Figure 3. The NFDPM calibration graph is produced by plotting NFDPM yield against tip solanesol (14 data points Regime 0 included), example depicted in Figure 4. The square of the linear correlation coefficient, R 2, is expected to be greater or equal to 0.95 for both these graphs. From the graphs the parameters of gradient and y-axis intercept for the two the linear regression equations may be derived. Nicotine and NFDPM yields of human smokers may be estimated from tip nicotine and tip solanesol measurements by applying the relationships shown in Equations 5 and 6 respectively y = 4.565x R² = y = 0.096x R² = Tip Nicotine (mg/tip) Tip Solanesol ( g/tip) Figure 3: Nicotine calibration graph G1 Figure 4: NDFPM calibration graph G2 Equation 5 Estimated nicotine yield = slope (G1) * tip nicotine + intercept (G1) Equation 6 Estimated NFDPM yield = slope (G2) * tip solanesol + intercept (G2) Occasionally human tip results will fall above the upper values of calibration smoking. The laboratory will need to decide if these results should be excluded; this may depend on number of subjects and how far beyond the upper smoking calibration point the results lie. Solutions can be diluted and re-analysed. 8. EXPRESSION OF RESULTS Estimated nicotine and NFDPM yields (in mg/cig) are rounded to 3 decimal places. 9. REPEATABILITY AND REPRODUCIBILITY An international collaborative study was conducted during 2013 using two cigarette products. Results from 8 laboratories (nicotine method) and 5 laboratories (solanesol method) were used in accordance with ISO procedures to calculate mean values, standard deviations and repeatability (r) and reproducibility (R) statistics (Tables 4 and 5). Generally, a measurement system is deemed to be acceptable if the introduced error between participants remains under 10%. This was fulfilled for the estimation of nicotine yield by tip nicotine and very closely fulfilled for estimated NFDPM by tip solanesol. CRM No. 80 January 2016 Page 9/16
10 Table 4: Results of International Collaborative Study Estimated Nicotine yield Estimated Nicotine Yield Number of labs in statistical evaluation Grand Mean (mg/cig) Repeatabilit y (r) (mg/cig) Reproducibility (R) (mg/cig) CV r (%) CV R (%) 1 mg ISO tar low regime 1 mg ISO tar high regime 10 mg ISO tar low regime 10 mg ISO tar high regime 8 of of of of Table 5: Results of Inter-Laboratory Tests Estimated NFDPM yield Estimated NFDPM Yield Number of labs in statistical evaluation Grand Mean (mg/cig) Repeatability (r) (mg/cig) Reproducibility (R) (mg/cig) CV r (%) CV R (%) 1 mg ISO tar low regime 1 mg ISO tar high regime 10 mg ISO tar low regime 10 mg ISO tar high regime 5 of of of of ANNEX 1 and 2 It is recommended that nicotine extracted from tips is assayed by GC with flame ionisation detection. Two general methodologies are illustrated in Annex 1 and 2; however, any locally validated method may be used. Chromatograms from the two GC methods are illustrated showing standards and extracted tips examples. CRM No. 80 January 2016 Page 10/16
11 Annex 1. Gas chromatographic conditions for measurement of nicotine on CP Wax GC column Gas Chromatograph: Agilent 6890 GC System, or equivalent Column: CP Wax 52 CB (polyethylene glycol) 25 m x 0.53 mm x 2.0 µm or equivalent Oven program: oven temperature 160 C initial time rate 1 4 min 80 C/min final temperature 230 C final time 2 min Column conditions: 2 as above Inlet: column part number column type carrier gas inlet pressure Agilent Technologies CP7658 polar phase helium 15 psi column flow ~ C velocity mode injection volume 1 µl liner mode ~137 cm/s constant pressure focus splitless temperature 250 C pressure purge time purge flow gas saver saver flow saver time 15 psi 0.1 min 40.0 ml/min on 20.0 ml/min 2.00 min Detector: Flame Ionisation Detection temperature 300 C H2 Flow air Flow make Up combined flow type n-heptadecane elution time nicotine elution time 30 ml/min 400 ml/min constant (N2) 30 ml flame one ~ 1.8 min ~ 3.6 min CRM No. 80 January 2016 Page 11/16
12 Annex 1 Figure 1: Nicotine standard chromatogram using CP Wax 52 CB Column Annex 1 Figure 2: Nicotine sample chromatogram using CP Wax 52 CB Column CRM No. 80 January 2016 Page 12/16
13 Annex 2. Gas chromatographic conditions for measurement of nicotine on HP-5 GC column Gas Chromatograph: Agilent 6890 GC System or equivalent Column: HP-5 (5% diphenyl, 95% dimethyl polysiloxane) 30 m x 0.32 mm x 0.25 m or generic DB-5 equivalent Oven program: initial oven temperature 60 C initial time ramp 1 2 min 6 C/min ramp temperature C ramp 2 30 C/min ramp temperature C hold time Column conditions: 2 min Inlet: column as above column part number Agilent Technologies 19091J-413 column type non-polar phase carrier gas helium inlet pressure 25 psi velocity 82 cm/s mode constant flow injection volume 1µL mode splitless temperature 270 C pressure 25 psi purge time 0.75 min purge flow 60.0 ml/min gas saver on saver flow 20.0 ml/min saver time 2.00 min Detector: Flame Ionisation Detection temperature 300 C H2 Flow 30 ml/min air flow 400 ml/min make up constant (N2) nicotine elution time ~ 9.8 min n-heptadecane elution time ~ 16.7 min CRM No. 80 January 2016 Page 13/16
14 Annex 2 Figure 1: Nicotine standard chromatogram using HP-5 column Annex 2 Figure 2: Nicotine sample chromatogram using HP-5 column CRM No. 80 January 2016 Page 14/16
15 Annex 3. Liquid chromatographic condition for measurement of solanesol Liquid chromatograph Agilent 1100 series LC System or equivalent column guard cartridge UV Detector Luna 3 µm C18(2) 100 Å (50 x 2 mm) (Phenomenex part number: 00B-4251-B0) or equivalent Security Guard C18 (4 x 3mm) (Phenomenex part number: AJO- 4287) or equivalent 210 nm injection volume 10 µl column temperature 30 C auto sampler temperature 5 C mobile phase gradient mobile phase A mobile phase B flow rate run time solanesol elution time isocratic 70 % HPLC grade methanol 30 % HPLC grade acetonitrile 0.3 ml/min 12 min ~ 9.5 min The system, with the UV lamp alight, is allowed to equilibrate with mobile phase for a minimum of 30 minutes before analysis. Solanesol HPLC analysis Reserve phase high performance liquid chromatography with UV detection is employed to quantify solanesol using a suitable column with isocratic elution. A suitable guard column may also be employed. The solanesol peak elutes at around 9.5 minutes. Example chromatograms from a standard and an extracted part-filter sample are shown in Annex 3 Figure 1 and Annex 3 Figure 2 respectively. CRM No. 80 January 2016 Page 15/16
16 Annex 3 Figure 1: Solanesol standard chromatogram Annex 3 Figure 2: Solanesol sample chromatogram CRM No. 80 January 2016 Page 16/16
1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.
Standard Method for Analysis of Benzene and Toluene Content in Hydrocarbon Waxes by Headspace Gas Chromatography EWF METHOD 002/03 (Version 1 Reviewed 2015) 1 Scope 1.1 This test method covers the qualitative
ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)
ACETA.02-1 ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) PRINCIPLE Isovaleraldehyde (IVA) and acetaldehyde are released from the syrup with the aid of dilute phosphoric acid and heat. The liberated
Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)
Method OIV-MA-AS313-22 Type II method Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008) 1. Introduction
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes
EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes Brussels, 18th May 2005 CED No 494 rev 2 Final TAXUD/3711/2004 POETRY:
CORESTA RECOMMENDED METHOD N 72
CORESTA RECOMMENDED METHOD N 72 DETERMINATION OF TOBACCO-SPECIFIC NITROSAMINES IN SMOKELESS TOBACCO PRODUCTS BY LC-MS/MS (February 216). INTRODUCTION The CORESTA Smokeless Tobacco Sub-Group studied various
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies
HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies Application Note Small Molecule Pharmaceuticals Authors Jignesh Shah, Tiantian Li, and Anil Sharma Agilent Technologies,
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography
Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample
Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*
Method 552.1 Revision 1.0 Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD* UCT Products: EUQAX156 (quaternary amine with Cl - counter ion, 6 ml cartridge)** CLTTP050 (CLEAN-THRU
Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection
52 May/June 2012 Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection by Karen Rome and Allyson McIntyre, AstraZeneca, Macclesfield, SK10 2NA, UK Quantitative analysis
Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids
Willamette University Chemistry Department 2013 Project 5: HPLC Analysis of Capsaicinoids LABORATORY REPORT: Formal Writing Exercises PRE-LAB ASSIGNMENT Read the entire laboratory project and section 28C
Purification of reaction mixtures using flash chromatography.
Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?
How To Develop A Recipe Card
TSNA Method Development Dr Michael Intorp CORESTA Cooperation Center for Scientific Research Relative to Tobacco FDA Center for Tobacco Products Scientific Workshop Tobacco Product Analysis 30 31 July
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS
Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic
TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION
TANNIC ACID Prepared at the 39th JECFA (1992), published in FNP Add 1 (1992) superseding specifications prepared at the 35th JECFA (1989), published in FNP 49 (1990) and in FNP 52 (1992). Metals and arsenic
ß-CYCLODEXTRIN SYNONYMS
ß-CYCLODEXTRIN Prepared at the 44th JECFA (1995), published in FNP 52 Add 3 (1995) superseding specifications prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications
Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension
International Journal of PharmTech Research CODEN (USA): IJPRIF ISSN : 0974-4304 Vol.2, No.2, pp 1634-1638, April-June 2010 Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination
Determination of Caffeine in Beverages HPLC-1
Determination of in s HPLC-1 Introduction This experiment provides an introduction to the application of High Performance Liquid Chromatography (HPLC) to the solution of complex analytical problems. Cola
Benzo[a]pyrene Method Development
Benzo[a]pyrene Method Development Dr Michael Intorp CORESTA Cooperation Center for Scientific Research Relative to Tobacco FDA Center for Tobacco Products Scientific Workshop Tobacco Product Analysis 30
SUCRALOSE. White to off-white, practically odourless crystalline powder
SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA
Tamsulosin Hydrochloride Capsules
. nal Revision Bulletin Official October 1, 2011 Tamsulosin 1 standard solution, and shake well. Centrifuge at 1500 rpm for 10 min, and use the supernatant, passing it if Tamsulosin Hydrochloride Capsules
23 The Thermal Conductivity Detector
23 The Thermal Conductivity Detector General Information TCD pneumatics Conditions that prevent the detector from operating Filament passivation Carrier, reference, and makeup gas Negative polarity Analyzing
All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &
105 6.1 CHARACTERIZATION OF TABLETS All the prepared formulations were subjected for following evaluation parameters and obtained results were showed in Tables 6.3 & 6.4. 6.1.1 Description (Size, Shape,
Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*
Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana* a Department of Pharmaceutical Analysis, Andhra University, Visakhapatnam. b Department of Pharmaceutics,
105 Adopted: 27.07.95
105 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Water Solubility INTRODUCTION 1. This guideline is a revised version of the original Guideline
Analytical Test Report
Analytical Test Report Customer: Address (City, State): Purchase Order: Report Number: Project Number: Date Received: Date of Report: Test Location: Boulder, CO. Assay: Part Number: Amino Acids by HPLC
A Complete Solution for Method Linearity in HPLC and UHPLC
Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,
LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)
October 2006 RESTRICTED LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006) DRAFT FOR DISCUSSION World Health Organization 2006 All rights reserved. This draft is intended for
With proper calibration, the upper limit may be extended as needed.
While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the
ERDOSTEINE - MONOGRAPH.
STRUCTURAL FORMULA (±1S-(2-[N-3-(2-oxotetrahydro thienyl)]acetamido)-thioglycolic acid) C 8 H 11 NO 4 S 2 M.W. = 249.307 DESCRIPTION Color : White to ivory white Appearance : Microcrystalline powder SOLUBILITY
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase
α-cyclodextrin New specifications prepared at the 57th JECFA (2001) and published in FNP 52 Add 9 (2001). An ADI not specified was established at the 57th JECFA (2001). SYNONYMS α-schardinger dextrin,
SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
CHAPTER 5 SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY CHAPTER 5 Simultaneous determination of Telmisartan
METHOD OF ANALYSIS. N methyl 2-pyrrolidone
METHOD OF ANALYSIS N methyl 2-pyrrolidone Center for Veterinary Medicine U.S. Food and Drug Administration 7500 Standish Place, Rockville, Maryland 20855 September 26, 2011 This method of detection for
Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis
Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines
Chem 131A: Absorbance of Riboflavin
Chem 131A: Absorbance of Riboflavin Purpose: The purpose of this experiment is to: 1) Familiarize the student with the use of the HP 8452 diode array spectrophotometer, 2) examine the limitations of the
Analysis of Vegetable Oils by High Performance Liquid Chromatography
Analysis of Vegetable Oils by High Performance Liquid Chromatography Using Evaporative Light Scattering Detection and Normal Phase Eluents Andrew J. Aubin, Cecilia B. Mazza, Donald A. Trinite, and Patricia
GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits
Issue Implementation Page 1 of 7 GC/MS Analysis of Vanillin and Ethyl Vanillin in Distilled Spirits Scope and Application This method will determine the level of vanillin and ethyl vanillin in distilled
ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE
ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE Determination of carbohydrates in foodstuff (LC/RID method) Exercise guarantor: Assoc. Prof. Karel Cejpek, Ph.D. CONTENT Required knowledge...
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
An In-Gel Digestion Protocol
An In-Gel Digestion Protocol This protocol describes the digestion of a protein present in an SDS-PAGE gel band with trypsin. The band can be taken from either a 1D or 2D electrophoresis gel. Reagents
LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: 1-13-93)
INTRODUCTION HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: 1-13-93) Headache, sore muscles, arthritis pain... How do you spell relief?
Determination of polyols derived from sugars and residual sugars found in dry wines by means of gas chromatography (Resolution Oeno 9/2006)
Method OIV-MA-AS311-06 Type IV method Determination of polyols derived from sugars and residual sugars found in dry wines by means of gas chromatography (Resolution Oeno 9/2006) 1. Scope Simultaneous determination
NWTPH-HCID. Hydrocarbon Identification Method for Soil and Water
NWTPH-HCID Hydrocarbon Identification Method for Soil and Water Summary This method is a qualitative and semi-quantitative procedure. It is used for groundwater or surface water, and soil/sediment from
How To Test For Contamination In Large Volume Water
Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed
Vitamin C quantification using reversed-phase ion-pairing HPLC
Vitamin C quantification using reversed-phase ion-pairing HPLC Thomas Grindberg and Kristy Williams Department of Chemistry, Concordia College, 901 8 th St S, Moorhead, MN 56562 Abstract Vitamin C, an
Protocol: HPLC (amino acids)
Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.
An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols. Jaap de Zeeuw, Ron Stricek and Gary Stidsen Restek Corp Bellefonte, USA To analyze basic compounds at
Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.
Gas Chromatography Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC. Samples in 10mL sealed glass vials were placed in the MPS-2
Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma
Mouse Insulin ELISA For the quantitative determination of insulin in mouse serum and plasma Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research Use Only. Not For Use
Expectations for GC-MS Lab
Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will
Drospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date
Drospirenone and Ethinyl Estradiol Tablets Type of Posting Revision Bulletin Posting Date 31 July 2015 Official Date 01 August 2015 Expert Committee MonographsSmall Molecules 4 Reason for Revision Compliance
Gas Chromatography Liner Selection Guide
Gas Chromatography Liner Selection Guide Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20551 Key Words Liner, focus Abstract The liner serves an important function in allowing
Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation
IJPAR Vol.4 Issue 4 Oct Dec - 2015 Journal Home page: ISSN: 2320-2831 Research Article Open Access Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation V.
CORESTA RECOMMENDED METHOD Nº 81
CORESTA RECOMMENDED METHOD Nº 81 ROUTINE ANALYTICAL MACHINE FOR E-CIGARETTE AEROSOL GENERATION AND COLLECTION DEFINITIONS AND STANDARD CONDITIONS (June 2015) 0. INTRODUCTION This Method includes the requirements
Coating and Extraction of Honeycomb Denuders
QSM Approval: Coating and Extraction of Honeycomb Denuders 1 INTRODUCTION 1.1 The following procedures are used for the coating of honeycomb denuders with citric acid and sodium carbonate solutions, and
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
Analysis of Various Vitamins in Multivitamin Tablets
High Performance Liquid Chromatography Analysis of Various Vitamins in Multivitamin Tablets Effective August 24, 2007, the US Food and Drug Administration (FDA) issued a regulation (21 CFR Part 111) that
Determination of the Mass Percentage of Copper in a Penny. Introduction
Determination of the Mass Percentage of Copper in a Penny Introduction This experiment will cost you one penny ($0.01). The penny must be minted after 1983. Any penny will do; for best results the penny
Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs
Agilent Application Solution Transfer of a USP method for prednisolone from normal phase PLC to SFC using the Agilent 126 Infinity ybrid SFC/UPLC System Saving time and costs Application Note Pharmaceutical
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep
Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10
HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.
HEXANES Prepared at the 51st JECFA (1998), published in FNP 52 Add 6 (1998) superseding specifications prepared at the 14th JECFA (1970), published in NMRS 48B (1971) and in FNP 52 (1992). ADI "limited
Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No. 1203 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS
POLYVINYL ALCOHOL Prepared at the 68 th JECFA (2007) and published in FAO JECFA Monographs 4 (2007), superseding specifications prepared at the 63 rd JECFA (2004) and published in the Combined Compendium
VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI
VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI Fakultas Farmasi Universitas Pancasila Jln. Srengseng Sawah,
ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS
VALIDATION OF ANALYTICAL METHODS 1 GERT BEUVING INTERNATIONAL PHARMACEUTICAL OPERATIONS TASKS: - Internal auditing - Auditing of suppliers and contract manufacturers - Preparing for and guiding of external
United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science
CLG-MG/CV2.00 Page 1 of 15 Contents A. INTRODUCTION... 2 B. EQUIPMENT... 3 C. REAGENTS AND SOLUTIONS... 4 D. STANDARDS... 5 E. SAMPLE PREPARATION... 6 F. ANALYTICAL PROCEDURE... 6 G. CONFIRMATION... 8
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS
A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler
CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA 91342 ABSTRACT
CRYOCOOLER CONTAMINATION STUDY S.W.K. Yuan, D.T.Kuo, and A.S. Loc EI Technologies, Cryocooler Group Sylmar, CA 91342 ASTRACT Eliminating or reduction of contamination is essential for the success of cryocoolers
CHROMOCTANE O N LINE ANALYZER
GECIL Process GT instruments CHROMOCTANE O N LINE ANALYZER ASTM D6733 DHA and RON and MON on line GC for Reformer unit Automatic Chromatographic system for analysis of naphta feeds and reforming gasolines
In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..
Identification of a Substance by Physical Properties 2009 by David A. Katz. All rights reserved. Permission for academic use provided the original copyright is included Every substance has a unique set
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.
The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen. Mark Crawford Single Presenter Name Abstract With the recent decline in hive bee populations this year the investigation of acaricides
Dissolved and precipitated oxalate
Accepted 2005 Process liquors from bleach plants Dissolved and precipitated oxalate Using Ion Chromatography 0 Introduction In bleach plants of pulp mills with a high degree of system closure, there is
Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC
Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC Mackenzie Ree and Erik Stoa Department of Chemistry, Concordia College, 901 8 th St S,
Agilent 7697A Headspace Sampler Data Sheet
Agilent 7697A Headspace Sampler Data Sheet Overview The Agilent 7697A Headspace Sampler is part of Agilent s line of gas chromtography products. The 7697A based on the architecture of the market-leading
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK
High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK Background Unilabs YBS are a bioanalytical CRO based in York (Uk) Copenhagen
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis
The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for
EnAlgae SOP: Biogas analysis
Table of content 1. PURPOSE... 2 2. PRINCIPLE... 2 3. REQUIREMENTS... 3 3.1. EQUIPMENT AND MATERIALS... 3 3.2. REAGENTS... 3 3.3. PREPARATION OF MEASUREMENT... 3 4. PROCEDURE... 4 4.1. SAMPLE MEASUREMENT...
Automation of Solid Phase Extraction and Column Chromatographic Cleanup
Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for
Analysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)
INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE ICH HARMONISED TRIPARTITE GUIDELINE VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY
Calibration of Glassware
Calibration of Glassware Introduction Glassware is commonly calibrated using a liquid of known, specific density, and an analytical balance. The procedure is to determine the mass of liquid the glassware
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and
Chapter 28: High-Performance Liquid Chromatography (HPLC)
Chapter 28: High-Performance Liquid Chromatography (HPLC) Scope Instrumentation eluants, injectors, columns Modes of HPLC Partition chromatography Adsorption chromatography Ion chromatography Size exclusion
MOISTURE (Karl Fischer, Buffered)
MOIST.03-1 MOISTURE (Karl Fischer, Buffered) PRINCIPLE SCOPE The sample is dissolved in a mixture of methanol and formamide (50:50 v/v) and then titrated with standardized Karl Fischer reagent. The titration
Assessment of Accuracy and Precision
2 chapter Assessment of Accuracy and Precision S.S. Nielsen, Food Analysis Laboratory Manual, Food Science Texts Series, DOI 10.1007/978-1-4419-1463-7_2, Springer Science+Business Media, LLC 2010 9 Chapter
Innovative vs Traditional
And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water
Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system
Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance
Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid
Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC
Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC Abstract: High performance liquid chromatography (HPLC) was used to determine the identity and concentrations of food dyes
Guidance for Industry
Guidance for Industry Q2B Validation of Analytical Procedures: Methodology November 1996 ICH Guidance for Industry Q2B Validation of Analytical Procedures: Methodology Additional copies are available from:
Experiment #1, Analyze Data using Excel, Calculator and Graphs.
Physics 182 - Fall 2014 - Experiment #1 1 Experiment #1, Analyze Data using Excel, Calculator and Graphs. 1 Purpose (5 Points, Including Title. Points apply to your lab report.) Before we start measuring
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan
Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract
PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE
Test Procedure for PARTICLE SIZE ANALYSIS OF SOILS TxDOT Designation: Tex-110-E Effective Date: August 1999 1. SCOPE 1.1 This method covers the quantitative determination of the distribution of particle
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma
SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application
