Low Pressure Injectors (Up to 28"w.c.) Bulletin 650. used. Orifice size will be determined by the factory if no size is specified by the customer.



Similar documents
M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

1805 Series Relief Valves

PREPIPED LIQUID FUEL MANIFOLDS PLPM

289 Series Spring-Loaded Relief Valves

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Types 66R and 66RR Low-Pressure Relief Valves

Your safety and the safety of others are very important.

Commercial Gas Water Heaters

Commercial & Industrial Propane Regulators and Meters

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

SIOUX HYBRID WATER HEATER

AUTOMATIC CHANGEOVER MANIFOLD Series 915

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

NFPA31FuelOilPiping 1 Revised

INSTALLATION INSTRUCTIONS

Your safety and the safety of others are very important.

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Heating Basics Gas Valve Systems

Instantaneous gas water heater

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

LANDFILL GAS ENCLOSED FLARE SYSTEM

Type 99 Pressure Reducing Regulator

167D Series Switching Valves

1301 Series High-Pressure Regulators

automatic Changeover regulators and systems manifolds/changeover regulators

FLASH TANK ECONOMIZER PRODUCT GUIDE

Commercial Gas Water Heater

SIZING AND CAPACITIES OF GAS PIPING

G234X-55 Conventional Gas Boiler

Better Boilers.

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

LP-Gas Serviceman s Manual

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

Commercial Gas Water Heaters

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Churrasco/Grill Manual Models: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits)

NAVIEN AMERICA INC FITCH AVENUE

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

REGULATORS 175/153 Series

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Open Cycle Refrigeration System

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

LPM-06 CONVERSION KIT

Gas Valves. Thermocouples. Pilots. Thermopiles. Water Heating WH/HVAC PRODUCT INFORMATION

Blast Furnace Gas-Fired Boiler for Eregli Iron & Steel Works (Erdemir), Turkey

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

PLUMBING RE-SUBMITTAL

SIZING AND CAPACITIES OF GAS PIPING

Bi-fuel systems for Diesel Engines in Oil & Gas drilling environments

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

VENTED NATURAL GAS LOGS

Installation Manual DIAPHRAGM WELL TANK

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Tray Distillation Columns. Efficiency, Flooding & Weeping

CITY OF LOS ANGELES CALIFORNIA

How To Install A Mazzei Injector

OPERATION OF Miniature Steam SLIDE VALVE STEAM ENGINES

Vectaire Gas Convection Ovens (Vertical Door)

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

1180 NW Maple Street, Ste. 310 Issaquah, WA U.S.A. +1 (425) ; +1 (425) (cell)

for light and heavy duty diesel engines

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

WARNING: IMPROPER SERVICING AND START-UP OF THIS EQUIPMENT MAY CREATE A POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING.

!"" #$% "!&' ( ( ) *

Flares are used extensively in the hydrocarbon and

M A N U A L

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

Commercial Gas Cooking Thermostats

DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

Regulator Options and Accessories

Specifications And Requirements For Gas Installations

High Efficiency Copper Finned Tube Boilers 750,000-2,000,000 BTU/HR

CSST Flexible Gas Pipe. System Design and Installation Manual

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Time Propane Pressure Drop Test Sign-Off Sheet

60 Series Pilot Regulator

Air Eliminators and Combination Air Eliminators Strainers

Many Products...One Source

Engineering Guide and Valve Selection Information

Chapter 3.5: Fans and Blowers

PARTS NEEDED FOR CONVERTING FROM LP TO NG

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

APCO SLOW CLOSING AIR/VACUUM VALVES

TYPE E Main Valve Sizes 3 /8 through 12

ECO-STAR II. ECO-nomical ECO-logical the ECO-STAR II. Packaged Low NOx Multi-Fuel Burner. Features. Benefits. Combustion Excellence Since 1888 ESII-1

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING

Type 92S Pilot-Operated Steam Regulator

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Transcription:

Bulletin 650 2/1/2011 Eclipse Atmospheric Injectors Eclipse Atmospheric Injectors are simple, low cost, adjustable mixers designed to provide an air/gas mixture to one or more burners. Atmospheric injectors use the kinetic energy of a stream of gas to entrain part or all of the air required for combustion. Two series of injectors are available; "Low Pressure", for use with gases up to 28"w.c. and "High Pressure", for gases from 1 psig to 30 psig. Both are available as either "Single Stage" or "Compound" units depending on the type of gas used. employ an additional sleeve which assists in entrainment for higher BTU gases. Standard orifice spuds are made of brass, but steel or other material can also be furnished for use with gases containing sulphur or other corrosive gases. The orifices listed are standard sizes. However, they can be drilled to any desired size or furnished blank. To prevent delays in shipment, the customer should specify either the orifice size desired, or the type and pressure of the gas to be used. Orifice size will be determined by the factory if no size is specified by the customer. Low Pressure Injectors (Up to 28"w.c.) Low Pressure Injectors entrain 30 to 50% of the combustion air required (depending upon the type of system) but sufficient secondary air should be provided around the burner outlet to complete combustion. Low pressure, single stage injectors are suggested for use with low and medium BTU gases up to 1200 BTU. For gases from 1200 BTU to 3300 BTU, a compound injector should be used. These mixers feature an adjustable air shutter and an integral gas flow adjusting needle. They can be purchased with or without a gas shut-off cock. Single stage injectors are available in sizes from 1/2" to 5". Compound injectors can be purchased in sizes from 1" to 5". Eclipse Atmospheric Injectors, Bulletin 650, 2/1/2011 1

High Pressure Injectors (1 to 30 psig) Eclipse High Pressure Injectors are designed to entrain all or part of the air required for combustion and deliver the mixture to the burner or burner manifold at a high enough pressure to prevent backfiring. These mixers can maintain a constant air/gas ratio throughout a range of turndown. High pressure, single stage injectors can be used for low and medium BTU gases up to 1100 BTU. Either a single stage or compound injector can be used for gases from Low Pressure Injectors (Capacities, CFH) Mixture Outlet Nat. Gas BTU/hr* Std. Orifice Size 750 to 1100 BTU. For gases above 1100 BTU, a compound injector should be used. Gas flow adjustment is provided by an external needle valve at the gas inlet. Air flow is adjusted by an integral air shutter. These mixers can be purchased with or without the gas adjusting valve and gas pressure gauge. Single stage injectors are available in sizes from 3/4" to 5". Compound injectors are available in sizes from 1" to 5". Propane & Butane Std. Orifice Size BTU/hr** Propane Butane TR-2 1/2" 10,000 #55 - - - - TR-3A 3/4" 12,000 #54 - - - - T-3 3/4" 16,000 #38 - - - - T-4A 1" 20,000 #49 - - - - T-4 1" 25,000 7/64" T-40 27,000 #50 #53 T-5 1-1/4" 40,000 9/64" T-50 45,000 #42 #47 TR-6 1-1/2" 55,000 5/32" TR-60 62,000 #31 #37 TR-8 2" 90,000 13/64" TR-80 100,000 #29 #30 TR-10 2-1/2" 140,000 9/32" TR-100 155,000 #18 #27 TR-12 3" 200,000 3/8" TR-120 220,000 #9 #18 TR-16 4" 340,000 7/16" TR-160 375,000 1/4" #3 TR-20 5" 540,000 9/16" TR-200 590,000 #1 15/64" * 1040 BTU Natural gas, 0.65 sp.gr., 7"w.c. inlet pressure ** 1.52 sp.gr. propane at 11"w.c. inlet pressure or 1.95 sp.gr. butane at 15"w.c. inlet pressure 2 Eclipse Atmospheric Injectors, Bulletin 650, 2/1/2011

Asy. No. w/ Gas Cock Asy. No. w/o Gas Cock A B C D E F TR-2 300262 300266 1/2" 1/8" - 6-9/16" 5-1/4" - TR-3A 300263 300267 3/4" 1/4" - 8-1/4" 6-3/4" 1-7/8" T-3 300202 200228 3/4" 3/8" 3-1/2" 1-3/8" 8-15/16" 7-3/8" TR-4A 300257 300258 1" 1/4" - 8-1/4" 6-3/4" 1-7/8" T-4 300203 300229 1" 3/4" 4-15/16" 1-13/16" 11-1/8" 8-3/4" T-5 300205 300231 1-1/4" 3/4" 5-1/8" 2" 12-1/2" 10-3/16" TR-6 300043 300003 1-1/2" 3/4" 5-1/8" 2" 11-9/16" 9-1/4" TR-8 300044 300004 2" 1" 6-1/4" 2-5/8" 13-1/4" 10-3/4" TR-10 300045 300005 2-1/2" 1 6-3/16" 2-5/8" 16-1/4" 13-3/4" TR-12 300046 300006 3" 1-1/4" 6-1/8" 2-3/4" 18-1/2" 15-13/16" TR-16 300047 300007 4" 1-1/4" 7" 3-1/2" 22-11/16" 19-3/16" TR-20 300048 300008 5" 1-1/4" 7-7/8" 4-1/8" 31-5/16" 27-7/8" T-40 300204 300230 1" 3/4" 5-7/16" 1-13/16" 13-1/8" 10-3/4" T-50 300206 300232 1-1/4" 3/4" 5-5/8" 2" 14-7/8" 12-9/16" TR-60 300063 300023 1-1/2" 3/4" 5-5/8" 2" 14-7/16" 12-1/8" TR-80 300064 300024 2" 1" 7" 2-5/8" 16-1/4" 13-3/4" TR-100 300065 300025 2-1/2" 1" 6-15/16" 2-5/8" 20-5/16" 17-13/16" TR-120 300066 300026 3" 1-1/4" 6-5/8" 2-3/4" 23-5/16" 20-5/8" TR-160 300067 300027 4" 1-1/4" 7" 3-1/2" 27-5/8" 24-1/8" TR-200 300068 300028 5" 1-1/4" 7-7/8" 4-1/8" 38-13/16" 34-3/4" High Pressure Injectors (Capacities, CFH) Mixture CFH Outlet CFH Coke Oven Gas* Natural Gas** Natural Gas** Propane*** TR-3HA 3/4" 6.2 8.4 - - - H-3 3/4" 50 17 - - - TR-4HA 1" 6.2 8.4 - - - H-4 1" 100 22.5 H-40 25 - H-5 1-1/4" 175 90 H-50 100 25 H-6 1-1/2" 250 135 H-60 150 50 H-8 2" 550 225 H-80 250 100 H-10 2-1/2" 850 405 H-100 450 150 H-12 3" 1300 585 H-120 650 200 H-16 4" 2500 1080 H-160 1200 400 H-20 5" 3500 1620 H-200 1800 600 * 595 BTU Coke Oven Gas, 0.42 sp.gr. at 10 psig inlet pressure. **1040 BTU Natural Gas, 0.65 sp.gr. at 25 psig inlet pressure. ***2500 BTU Propane Gas, 1.55 sp.gr. at 25 psig inlet pressure. Eclipse Atmospheric Injectors, Bulletin 650, 2/1/2011 3

J NPT Housing Inlet J NPT Housing Inlet Assembly With Valve and Gauge* Less Valve and Gauge A B C D E F G H J H-3 300401 300420 3/4 3/8 4-3/4 1-3/8 11-3/8 8-5/16 6 7-3/8 3/8 TR-3HA 300269 300267 3/4 1/8 2-3/8 6-3/4 9 2-1/4 - - - TR-4HA 300259 300258 1 1/8 2-3/8 6-3/4 9 2-1/4 - - - H-4 300402 300421 1 3/4 4-7/8 1-13/16 14-3/4 11-1/4 7 7-7/8 3/4 H-5 300404 300423 1-1/4 3/4 5 2 17-7/8 14-1/4 10 11-15/16 3/4 H-6 300406 300425 1-1/2 3/4 5 2 20-1/4 16-3/4 12-1/4 14-7/16 3/4 H-8 300408 300427 2 3/4 5 2-5/8 21-1/4 18-1/8 13-1/4 15-5/8 1 H-10 300410 300429 2-1/2 1 5-5/8 2-5/8 26 22-1/2 17-1/4 20 1 H-12 300412 300431 3 1 5-5/8 2-3/4 31 28-1/2 22-3/8 26-13/16 1 H-16 300414 300433 4 1-1/4 5-3/4 3-1/2 35-3/4 32-11/16 26-1/4 29-3/16 1-1/4 H-20 300416 300435 5 1-1/4 6-1/2 4-1/8 42 38-7/8 31-1/2 34-13/16 1-1/4 H-40 300403 300422 1 3/4 4-13/16 1-13/16 16-1/4 13-3/32 8-7/8 10-3/4 3/4 H-50 300405 300424 1-1/4 3/4 5 2 19-1/2 15-7/8 11-5/8 13-9/16 3/4 H-60 300407 300426 1-1/2 3/4 5 2 20-3/8 16-7/8 12-3/8 14-9/16 3/4 H-80 300409 300428 2 3/4 5 2-5/8 21-3/8 17-29/32 13-1/16 15-7/16 3/4 H-100 300411 300430 2-1/2 1 5-5/8 2-5/8 25-15/16 22-7/16 17-3/16 19-15/16 1 H-120 300413 300432 3 1 5-5/8 2-3/4 32-1/8 30 23-7/8 27-5/16 1 H-160 300415 300434 4 1-1/4 5-3/4 3-1/2 35-9/16 32-9/16 26-1/8 29-1/16 1-1/4 H-200 300417 300436 5 1-1/4 6-1/2 4-1/8 42-9/16 39-3/16 31-13/16 35-1/8 1-1/4 *No gauge on TR-3HA and TR-4HA. 4 Eclipse Atmospheric Injectors, Bulletin 650, 2/1/2011

Mixer Heads Low Pressure Assembly With Gas Less Gas Cock Cock A B C D E F NS-3 300101 300116 3/4 3/8 3-1/2 1-3/8 4 - NS-4 300103 300118 1 3/4 4-15/16 1-13/16 5-13/16 - NS-5 300105 300120 1-1/4 3/4 5-1/8 2 5-5/8 - NS-6 300107 300122 1-1/2 3/4 5-1/8 2 6 - NS-8 300109 300124 2 1 6-1/4 2-5/8 6-3/8 - NS-10 300111 300126 2-1/2 1 6-3/16 2-9/16 6-1/4 - NS-120 300112 300127 3 1-1/4 6-1/8 2-1/2 7-7/16 - NS-160 300113 300128 4 1-1/4 7 3-3/8 8-3/16 - NS-200 300114 300129 5 1-1/4 7-7/8 4-1/4 9-1/8 - High Pressure HO-3 300311 300301 3/4 3/8 4-3/4 1-7/8 3-3/8 5-3/8 HO-4 300312 300302 1 3/4 4-7/8 1-7/8 5-1/4 8-3/4 HO-5 300313 300303 1-1/4 3/4 5 2 5-1/4 8-7/8 HO-6 300314 300304 1-1/2 3/4 5 2 4-7/8 7-3/4 HO-8 300315 300305 2 1 5 2 5-3/4 9-1/4 HO-10 300316 300306 2-1/2 1-1/4 5-5/8 2-5/8 6 9-1/2 HO-120 300317 300307 3 1-1/4 5-5/8 2-5/8 6-1/4 8-3/4 HO-160 300318 300308 4 1-1/4 5-3/4 2-3/4 7-3/8 10-7/8 HO-200 300319 300309 5 1-1/4 6-1/2 3-1/2 7 10-1/4 Eclipse Atmospheric Injectors, Bulletin 650, 2/1/2011 5

Bulletin 650, 2/1/2011

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (804) 236-3882 www.peconet.com