VENTED NATURAL GAS LOGS

Size: px
Start display at page:

Download "VENTED NATURAL GAS LOGS"

Transcription

1 VENTED NATURAL GAS LOGS MODEL #WAN18N-2 WAN24N-2 CAUTION - FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air For Combustion and Ventilation section on page 5 of this manual. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This appliance may be installed in an aftermarket, permanently located manufactured (mobile) home, where not prohibited by local codes. This appliance is convertible for use with propane/ LP gas by using the MANUAL ON/OFF VALVE/SAFETY PILOT KIT (see ACCESSORIES on page 11). Questions about installation, operation, or troubleshooting? Before returning to your retailer, call customer service department toll-free at (877) PC-WAN

2 TABLE OF CONTENTS Important Safety Information...3 Product Features...4 Air For Combustion and Ventilation...5 Installation...6 Installing Logs...9 Operation...10 Care & Maintenance...11 Troubleshooting...12 Replacement Parts...13 IMPORTANT: Read instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. PRODUCT SPECIFICATIONS Note: This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. The charts indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted. The fireplace must include a working flue and venting system with the minimum openings shown as below. MODEL # BTU Input Natural Gas BTU Input Propane Gas Minimum Vent Opening WAN18N-2 45,000 45,000 8 in. dia. WAN24N-2 55,000 55,000 8 in. dia. FUEL INLET PRESSURE SPECIFICATIONS (W.C.) Min. Max. Natural Gas 5.5 in in. Propane Gas 11 in. 13 in. MODEL # MINIMUM FIREBOX SIZES Front Width * Back Width * Depth Height WAN18N-2 24 in. 18 in. 15 in. 18 in. WAN24N-2 28 in. 22 in. 15 in. 18 in. * Add 4 in. when using on/off valve safety pilot kit BURNER ORIFICE MODEL # NUM. (NATURAL) NUM. (PROPANE/LP) WAN18N WAN24N NUM. is printed on orifice 2

3 IMPORTANT SAFETY INFORMATION IMPORTANT: Read this owner s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. Only a qualified installer, service agent, or local gas supplier may install and service this product. WARNING: Keep flue open when operating unit. DANGER: Carbon monoxide poisoning may lead to death! CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air immediately! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease, people who are anemic, those under the influence of alcohol, and those living in high altitudes. NATURAL GAS: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to operating this log set safely. WARNING: Any change to this log set or its controls can be dangerous. WARNING: This appliance is for installation only in a solid-fuel burning masonry or factory-built fireplace, constructed of noncombustible material, and connected to a working flue. 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate.this appliance is convertible for use with propane/lp, using the MANUAL ON/OFF VALVE/SAFETY PILOT KIT. 2. If you smell gas: Shut off gas supply Do not try to light any appliance Do not touch any electrical switches; do not use any phone in your building Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions If you cannot reach your gas supplier, call the fire department 3. Never install the log set: In a recreational vehicle Where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set In high traffic areas In windy or drafty areas 4. Before installing in a solid fuel burning fireplace, the chimney flue and fire-box must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. 5. You must operate this log set with a fire-place screen in place. Make sure fireplace screen is closed before running log set. If the fireplace has glass doors, they must remain OPEN while this log set is in operation. 6. This log set is designed to be smoke- less. If logs ever appear to smoke, turn off appliance and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window. 7. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting. 8. Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this log set. 9. This log set needs fresh, outside air ventilation to run properly. See the Air for Combustion and Ventilation section, page Do not run log set where flammable liquids or vapors are used or stored under dusty conditions 3

4 11. Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects. 12. Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing ignition. Log set will remain hot for a short time after shut-down. Allow surface to cool before touching. 13. Carefully supervise young children when they are in the room with log set. 14. Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room appliance and to replace any part of the control system (if using control system) and any gas control which has been under water. 15. To help prevent breakage, new logs must be broken-in (see Curing Logs page 11). 16. Turn log set off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair log set. PRODUCT FEATURES ON/OFF VALVE/SAFETY PILOT KIT AND PROPANE/LP CONVERSION An optional on/off valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this optional system for LP conversion. LOCAL CODES Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. National Fire Protection Association, Inc Broadway 1 Batterymarch Park New York, NY Quincy, MA UNPACKING CAUTION: Do not remove the metal data plates from the burner pan. The data plates contain important product information. 1. Remove logs, hearth kit, pan materials, and hardware from carton. 2. Remove all protective packaging applied to logs and base for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product. Fig. 1 Product Identification Grate Steps Grate Burner Pan Burner Clamp Burner Manifold Burner Inlet Fitting 4

5 AIR FOR COMBUSTION AND VENTILATION WARNING: If the area in which the heater may be operated does not meet the required volume for indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Today's homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will ensure proper venting of vented fuel-burning appliances. WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components, or accessory items, will void the manufacturer's warranty, and may result in a hazardous condition. CAUTION: Do not remove the metal data plates attached to the burner pan. The data plates contain important warranty information. CHECK GAS TYPE Use only natural gas. If your gas supply is not natural gas, you must install On/Off Valve/Safety Pilot Kit (see Accessories, page 11). If the fireplace does not have a gas supply shutoff valve, one must be installed. 5

6 INSTALLATION VENTING SPECIFICATIONS FOR INSTALLATION The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting, light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved. The chimney flue must remain open a minimum of 3 in. at all times during the operation of this log set. INSTALLING DAMPER CLAMP Secure the damper stop clamp provided to the leading edge of the damper as shown in Fig. 2. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed. HEARTH KIT ASSEMBLY Note: The following instructions apply to dual flame "U" style burners. Be sure all pipe threaded connections are tight, and have thread compound to prevent leaks. 1. Determine which side the gas line will be coming into the fireplace. 2. Using a hammer and screwdriver, remove knock-out plug from the side of the pan that corresponds to the gas line (see Fig. 3). 3. Unscrew burner inlet fitting from burner manifold (see Fig. 4). 4. Place burner manifold in pan with threaded opening facing open knock-out plug. 5. Using thread sealant (resistant to the action of natural gas) on larger end of fitting, screw the burner inlet fitting through hole and into burner manifold. Tighten using a wrench. 6. Using burner clamp, screw, and nut provided, assemble clamp to pan. This will hold the burner manifold in place. 7. If using optional control system kit, follow instructions included with kit for installation and operation. Fig. 2 Attaching Damper Clamp Damper Masonry Fireplace Damper Clamp Damper Clamp Damper Fig. 3 Knock-Out Plug Locations Burner Pan Assembly (Facing Front of Fireplace) Damper Manufactured Fireplace Knock - Out Plugs Fig. 4 Installing Burner Burner Clamp Nut Washer Burner Manifold Burner Pan Screw Burner Inlet Fitting 6

7 Installation and Gas Connection 1. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward. 2. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant. Fig. 5 Connecting Gas to Appliance Gas Connector Tube 3. Install adapter fitting onto the burner inlet fitting using thread sealant on male threads of burner inlet fitting (see Fig. 5). 4. Install the gas connector tube to the gas supply fitting. Carefully shape tube to attach to adapter fitting. CONNECTION TO GAS SUPPLY Burner Pan Assembly (Facing Front of Fireplace) Adapter Fitting WARNING: A qualified service person must connect log set to gas supply. Follow all local codes. INSTALLTION ITEMS NEEDED Before installing log set, make sure you have the items listed below. piping (check local codes) sealant (resistant to natural gas) equipment shutoff valve test gauge connection adjustable (crescent) wrench or pliers sediment trap tee joint pipe wrench CAUTION: Only use a new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2 in. diameter or greater to allow proper gas volume to log set. If pipe is too small, loss of pressure will occur. Installation must include an equipment shutoff valve, union, and plugged 1/8 in. NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Fig. 6). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector. Install sediment trap in supply line as shown in Fig. 6. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed incorrectly, log set may not run properly. Fig. 6 Gas connection Approved Flexible Gas Hose (if allowed by local codes) CSA Design - Certified Equipment Shutoff Valve with 1/8 in. NPT Tap* 3 in Minimum From Gas Meter (5 in W. C.**) to 10.5 in. W. C. pressure Cap Pipe Nipple Tee Joint Sediment Trap * Purchase the optional CSA design-certified equipment shutoff valve from dealer. See Accessories page 11. ** Minimum inlet pressure for purpose of input adjustment. 7

8 CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks immediately. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks immediately. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG ( 3.5kPa ) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening gas supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks immediately. 6. Reconnect log set and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kpa) 1. Close equipment shutoff valve (see Fig. 7). 2. Pressure supply piping system by either using compressed air or opening gas supply tank valve. 3. Check all joints from gas meter to equipment shutoff valve (see Fig. 7). Apply mixture of liquid soap and water to gas joints. If bubbles form, there may be a leak. 4. Correct all leaks immediately. Fig. 7 Checking Gas Joints Equipment Shutoff Valve Gas Meter TESTING BURNER FOR LEAKS 1. Generously apply soapy solution to all connections. WARNING: Never check for gas leaks with open flame. 2. Light the burner with the shutoff valve, no more than half open, and holding a match slightly in front of the pan (see Lighting Instructions, page 10). 3. Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are detected, shut off the gas valve immediately. Tighten, or reassemble the loose connection(s) using pipe joint compound until burner system is leak free. 4. When the burner is tested and leak free, observe the individual tongues of flame on the burner. Note: Let the burner manifold cool first before removing to unclog port blockages. The burner design includes more ports on the outside of the bar. Make sure that all ports are clear and producing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suit able tool. 5. When finished testing, turn the gas shutoff valve OFF to extinguish all flames. 8

9 INSTALLING LOGS (WAN18-2 & WAN24-2) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation and periodically thereafter, check to ensure that no yellow flame comes in contact with any log. With the heater set to High, check to see if yellow flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Yellow flames contacting logs will create soot.it is very important to install the logs exactly as instructed. Do not modify logs. Use only logs supplied with heater. Each log is marked with a number. This number will help you to identify the logs when installing. After installing logs, add decorative cinders around the grate base, do not place any decorative cinders on logs or burner. Provided Logs: 8 Vermiculite and Glowing Ember Vermiculite and Glowing Ember Vermiculite and Glowing Ember 1. Firstly put vermiculite into burn pan. Then pulling glowing ember loosely, and sprinkle uniformly the surface of vermiculite. And insert log #1 into slots in rear log bracket on grate base. 2. Insert log #2 into slots in middle grate bracket. 3. Insert #3 on log #1 and log #2. Vermiculite and Glowing Ember Vermiculite and Glowing Ember 4. Insert log #4 on log #1 and log #2. 5. Insert log #5 on log #1 and log #2. 6. Place log #6-1, 6-2, 6-3 in front. 9

10 OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Turn the gas shutoff valve to OFF. 3. Wait five (5) minutes to clear out any gas. If you still smell gas, STOP! Follow the safety information above. If you don't smell gas, go on to the next step. 4. Light a match and lay it on top of the pan material about 2 in. from the end of the supply side of the pan. 5. Slowly turn the gas shutoff valve ON until the burner ignites. If the burner doesn't ignite within 10 seconds with the match burning, turn the shutoff valve OFF and repeat steps 1 through 4 again. Flame Adjustment GAS SHUTOFF VALVE OPERATION Adjust the flame ON/OFF by turning the gas shutoff valve counterclockwise to open or clockwise to close, as necessary. Shutting Off Appliance Turn gas shutoff valve clockwise to the OFF position. 10

11 CARE AND MAINTENANCE Keep the area around the log set clean and clear of debris. Occasionally, you may use a soft bristle brush to clean logs. Once every year a qualified agency or certified chimney sweep should examine and clean the venting system of the fireplace. ACCESSORIES Purchase these fireplace accessories from your local dealer. If they can not supply these accessories, contact customer service department for information. Equipment shutoff valve EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8 in. NPT tap. Fits 1/2 in. NPT pipe. ON/OFF VALVE/SAFETY PILOT KIT - NVDWA1 For all models. Required for propane/lp installation. ON/OFF Valve/Safety Pilot Kit CURING LOGS During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time. To ensure proper curing of the logs: Ignite a 2 in. flame and maintain it for 1 hour. Burn the logs in consecutive 1 hour periods raising the flame an additional 2 in. to full flame height for a total of three hours. 11

12 TROUBLESHOOTING WARNING: If you smell gas: Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. Note: All troubleshooting items are listed in order of operation. WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair heater. Problem Possible Cause Corrective Action Log set is smoking/ sooting excessively (Note: It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flames contact the logs). Burner is excessively noisy. (Note: The movement and combustion of gas will create low, unavoidable levels of noise.) Burner flame is too low or too high. Log Set produces a clicking/ ticking noise just after burner is lit or shut off. Log Set produces unwanted odors. Gas odor even when control knob is in OFF position. Gas odor during combustion. 1. Poor fuel quality. 2. Fireplace venting system not drafting properly. 3. Excessive flame impingement or blockage. 4. Improper fuel/air mixture. 5. Excessive gas supply/pressure. 1. Passage of air/gas across irregular surfaces. 1. Incorrect gas supply or pressure. 2. Blocked burner orifice or burner manifold ports. 3. Improper burner orifice size. 1. Metal expanding while heating or contracting while cooling. 1. Log Set burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement page 12). 2. Gas leak. See Warning statement at top of page Gas leak. See Warning statement at top of page. 2. Control valve defective 1. Gas leak. See Warning statement at top of page. 1. Contact local natural gas company. 2. Adjust damper wide open and/or have fireplace and venting professionally cleaned and checked. 3. Separate the logs to allow more flame passage. 4. Remove any foreign items from the flame pattern. 5. Preheat flue in very cold weather. 1. Relieve any tight bends or kinks in gas supply line. 1. Check for proper gas supply pressure. 2. Free burner orifice and manifold ports of any burrs, paint, or other blockage. 3. Verify proper burner orifice sizing (see page 2). 1. This is common with most log sets. If noise is excessive, contact qualified service person. 1. Open flue to maximum. Stop using odor causing products while log set is running. 2. Locate and correct all leaks (see Checking Gas Connections, page 8). 1. Locate and correct all leaks (see Checking Gas Connections, page 8). 2. Replace control valve. 1. Locate and correct all leaks (see Checking Gas Connections, page 8). 12

13 REPLACEMENT PARTS NOTE: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Call Customer Service toll free at (877) for referral information. When calling Customer Service or your dealer, have ready: Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used (Propane/LP or Natural gas/ng) Purchase date Usually, we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Call Customer Service toll free at (877) for referral information. When calling Customer Service have ready: Model number of your heater The replacement part number 13

14 PARTS LIST (WAN18N-2) This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 13 of this manual. Part. Description Part # QTY 1 3/8 in. Female x 5/8 in. Flare Adapter BL Injector Mounting WAL Injector WAL07-01N 1 4 Grate Step WAB PARTS AVAILABLE----NOT SHOWN Manual PC-WAN Vermiculite WAL Glowing Embers GLEMVERM25 1 Log Assembly WAN18B 1 Log 1 WAN Log 2 WAN Log 3 WAN Log 4 WAN Log 5 WAN Log 6-1 BAVIN-1 1 Log6-2 BAVIN-2 1 Log 6-3 BAVIN-3 1 Hardware Packaging WAN300B Bag For Accessory ML /2 in. Female x 5/8 in. Flare Adapter WAL Damper Clamp WAL Screw Stem GB/T5780-6*80-Z 1 14

15 PARTS LIST (WAN24N-2) This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 13 of this manual. Part. Description Part # QTY 1 3/8 in. Female x 5/8 in. Flare Adapter BL Injector Mounting WAL Injector WAL07-02N 1 4 Grate Step WAB PARTS AVAILABLE----NOT SHOWN Manual PC-WAN Vermiculite WAL Glowing Embers GLEMVERM25 1 Log Assembly WAN24B 1 Log 1 WAN Log 2 WAN Log 3 WAN Log 4 WAN Log 5 WAN Log 6-1 BAVIN-1 1 Log6-2 BAVIN-2 1 Log 6-3 BAVIN-3 1 Hardware Packaging WAN300B Bag For Accessory ML /2 in. Female x 5/8 in. Flare Adapter WAL Damper Clamp WAL Screw Stem GB/T5780-6*80-Z 1 15

16 16

17 WARRANTY INFORMATION Keep This Warranty IMPORTANT: We urge you to fill your warranty registration card within TEN(10) days of date of installation, complete with the entire serial number which can be found on the rating plate. Retain this portion of the card for your record. Always specify model and serial numbers when communicating with customer service. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY: PRO-COM warrants this product to be free from defects in materials and components for ONE (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions, to make a claim under this warranty, the Bill of Sale or cancelled check must be presented. RESPONSIBILITY OF OWNER This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a PRO-COM Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or PRO-COM who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit. WHAT IS NOT COVERED This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner. TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT, THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES. INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE. PRO-COM'S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND PRO- COM SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT. INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of accidental or consequential damages, the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you. This warranty gives you specific legal right, and you may also have other rights that vary from state to state. 17 Printed in China

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS Installation and service must be provided by a qualified installer, service agency or gas supplier Grand Canyon Gas Logs, logs are made

More information

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING. INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...

More information

SPARK MODERN FIRES RETROFIT FIRE RIBBON VENTED DECORATIVE APPLIANCE OWNER S OPERATION AND INSTALLATION MANUAL

SPARK MODERN FIRES RETROFIT FIRE RIBBON VENTED DECORATIVE APPLIANCE OWNER S OPERATION AND INSTALLATION MANUAL SPARK MODERN FIRES RETROFIT FIRE RIBBON VENTED DECORATIVE APPLIANCE OWNER S OPERATION AND INSTALLATION MANUAL Z21.60b-2004 / CSA 2.26b-2004 APPROVED 321-L-06-5 WARNING: If the information in this manual

More information

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 150000 200605 LP Gas Tools needed Bottle brush Non-abrasive scouring pad Small utility brush Heavy-duty pipe cleaners Air hose

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS VGBQ SERIES CONVERSION KIT VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662) 455-1200 IMPORTANT: PLEASE READ AND FOLLOW 1. Before beginning,

More information

San josé OWNER S MANUAL

San josé OWNER S MANUAL San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw

More information

SL280UHV SERIES GAS FURNACE WARNING

SL280UHV SERIES GAS FURNACE WARNING 2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could

More information

orlando OWNER S MANUAL

orlando OWNER S MANUAL orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.

More information

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 10 mm open end wrench 12 mm open end wrench 9/16 open end wrench 5/8 open end wrench 11/16 open end wrench 9/16

More information

GAS SAFETY PRECAUTIONS

GAS SAFETY PRECAUTIONS GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.

More information

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems American Fireglass Outdoor Fire pit kit information General instructions/warnings for outdoor gas pan and burner systems We strongly recommend that our burner products be installed by a licensed and certified

More information

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Models GWRP16A, GWRn18A, GWRP26A, GWRn30A GWRP16TA, GWRn18TA, GWRP26TA and GWRn30TA WARNING: If the information in this

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information

HEATMASTER, LLC AMERICAN GAS LOG

HEATMASTER, LLC AMERICAN GAS LOG Models: HEATMASTER, LLC AMERICAN GAS LOG DG-SS-18/24/30NG AGL-SS-18/24 NG H-SS-24NG HM2-SS-24NG Outdoor Burner/Hearth Kits For use use with Natural gas only Installation Instructions Installation and service

More information

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL. BGe18NR, BGe18PR, BGe2436NR and BGe2436PR

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL. BGe18NR, BGe18PR, BGe2436NR and BGe2436PR UNVENTED (VENT-FREE) GAS LOG HEATER OWNER S OPERATION AND INSTALLATION MANUAL PFS US Remote-Ready BURNER SYSTEM MODELS BG18NR, BG18PR, BG2436NR, BG2436PR, BGe18NR, BGe18PR, BGe2436NR and BGe2436PR FOr

More information

VENT-FREE GAS LOG SET

VENT-FREE GAS LOG SET VENT-FREE GAS LOG SET MODEL # VFL-CY24DR VFL-HT24DR VFL-CY30DR VFL-HT30DR WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural

More information

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance ASK THE EXPERT: Burner Troubleshooting Information & Maintenance The burner is the heart of your BBQ. It is subject to a number of conditions that can cause damage, and lead to potential safety issues.

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT7- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... INSTALLATION INSTRUCTIONS...

More information

UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL

UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL UNVENTED (VENT-FREE) INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL Model: IWH10NLTB Model:IWH16NLTB WARNING: If the information in this manual is not followed exactly, a fi re or explosion

More information

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural

More information

OWNER S OPERATION AND INSTALLATION MANUAL

OWNER S OPERATION AND INSTALLATION MANUAL BLUE FLAME VENT- FREE PROPANE/LP GAS SPACE HEATER OWNER S OPERATION AND INSTALLATION MANUAL HB06ML- HB0ML- HB0TL- Table of Contents Important Safety Information...2 Product Features...3 Proper Ventilation

More information

TWO BURNER PROPANE CAMPING STOVE

TWO BURNER PROPANE CAMPING STOVE OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS TWO BURNER PROPANE CAMPING STOVE WARNING READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE. Propane

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLER/CONSUMER RETAIN THIS APPLIANCE MANUAL WITH THE INSTALLED APPLIANCE INSTALLATION AND OPERATING INSTRUCTIONS GOLDEN BLOUNT TOP-VENT FIREPLACES MODEL HD5030-TV EL GRANDE HD4240-TV SKYSCRAPER CSA

More information

CAUTION - FOR YOUR SAFETY

CAUTION - FOR YOUR SAFETY WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane gases. Vent-Free Gas Log Heater MODEL: PCD8T PCD24TD PCD24M CAUTION

More information

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type

More information

DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION

DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION DIRECT VENT GAS FURNACE FOR THROUGH THE WALL OR WINDOW INSTALLATION OWNER'S OPERATION AND INSTALLATION MANUAL SA25N SA25P SA40N SA40P WARNING: If the information in these instructions is not followed exactly,

More information

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992

More information

Tankless Water Heater

Tankless Water Heater Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY Form CP-F/B-GC (Version A.2) Obsoletes Form CP-F/B-GC (Version A) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE Model B Model F All gas conversion must be done by a qualified

More information

USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A.

USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A. S o n o m a PLATINUM EDITION Sonoma Platinum Edition Grill: 27 Model TM USE AND CARE MANUAL FOR OUTDOOR USE ONLY MADE IN THE U.S.A. General Safety Instructions IMPORTANT SAFETY INFORMATION - Read this

More information

!"" #$% "!&' ( ( ) *

! #$% !&' ( ( ) * !"" #$% "!&' (( ) * G Whiz Gas Popper Instruction Manual Model #5908 Part No. 74874 Revised October 1997 Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells

More information

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING

HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING HIGH PRESSURE RADIANT GAS BROODER MODELS: SHP17B (-6) MODULATING INSTALLATION AND OPERATION INSTRUCTIONS OWNER/INSTALLER: For your safety this manual must be carefully read before installing, operating

More information

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE? WHAT IS A BTU? The standard energy measurement is the BTU (British Thermal Unit). Each BTU unit is determined by the amount of thermal energy required to raise the temperature of one pound of water by

More information

VENT-FREE GAS LOG SET

VENT-FREE GAS LOG SET VENT-FREE GAS LOG SET MODEL # VFL-CO18DT VFL-MD18DT VFL-CO24DT WARNING: This appliance is equipped for (Natural and Propane) gas. Field conversion is not permitted other than between natural or propane

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Installation Instructions for Alarm Module Kit A043F059

Installation Instructions for Alarm Module Kit A043F059 Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line

More information

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting

More information

TWO BURNER PROPANE CAMPING STOVE

TWO BURNER PROPANE CAMPING STOVE 842-A100-S_CmpStove.qxd 2/10/06 11:20 AM Page 1 OWNER S MANUAL TWO BURNER PROPANE CAMPING STOVE FAILURE TO FOLLOW ALL S AND INSTRUCTIONS IN THIS MANUAL COULD LEAD TO PERSONAL INJURY, INCLUDING DEATH. RETAIN

More information

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS

AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS INSTALLATION & OWNER S MANUAL AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS Models: EPK-1(M)(P) FEATURES: INTERMITTENT PILOT IGNITION NON-STANDING FLAME-SENSING PILOT MANUAL

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

PROPANE CONSTRUCTION HEATER

PROPANE CONSTRUCTION HEATER Dyna-Glo, Dyna-Glo Pro Dyna-Glo Delux PROPANE CONSTRUCTION HEATER USER S MANUAL AND OPERATING INSTRUCTIONS MODEL # RA18LPDG, RA18LPDGD, RA18LPDGP, RA18LPA, RA18LPB, and RA18LPC C US CSA 2.14b-2009, ANS

More information

Instruction Manual for Residential Manufactured Home Gas Water Heaters

Instruction Manual for Residential Manufactured Home Gas Water Heaters Instruction Manual for Residential Manufactured Home Gas Water Heaters FOR USE ONLY IN MANUFACTURED HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE

More information

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause

More information

UNVENTED LP-GAS FIRED ROOM HEATER

UNVENTED LP-GAS FIRED ROOM HEATER Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. INSTALLATION Instructions and Owner s Manual READ INSTRUCTIONS CAREFULLY: Read and follow all instructions.

More information

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve APPLICATION The VS8510, VS8520 Millivolt Gas Valve is compact and has a 60,000 Btuh capacity (1 in. pressure drop for straight through configuration). Its design makes it ideal for fireplace and space

More information

Owner s Manual PATIO HEATER

Owner s Manual PATIO HEATER RTA International For Evaluation Only Edited by Foxit PDF Editor Copyright (c) by Foxit Software Company, 2004 Owner s Manual PATIO HEATER TOLL FREE After Service Number 1-888-775-1330 IMPORTANT Read this

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4 Model TSP2, TSP3 and TSP4 Owner s Manual July 2010 Table of Contents 1 Introduction...................................................... 1 1.1 Read before using..............................................

More information

MODEL G300 BRAKE BLEEDER

MODEL G300 BRAKE BLEEDER MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY

More information

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation. Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A. 04072 877-854-8006 * FAX (207) 283-8080 FOR SERVICE ASSISTANCE U.S. AND CANADA CALL: 1-877-854-8006 24 HOURS/DAY 7 DAYS/WEEK TABLE OF CONTENTS

More information

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

30 GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

Owner s Manual 58HDX UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE. ama ! WARNING SAFETY CONSIDERATIONS

Owner s Manual 58HDX UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE. ama ! WARNING SAFETY CONSIDERATIONS UPFLOW / HORIZONTAL / DOWNFLOW HIGH EFFICIENCY GAS FURNACE Owner s Manual NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. USER: Please read all instructions in the manual and retain

More information

OBSOLETE. VS8420 Millivolt Gas Valve

OBSOLETE. VS8420 Millivolt Gas Valve APPLICATION The VS8420 Millivolt Gas Valve is compact and has a 60,000 Btuh capacity (1 in. pressure drop for straightthrough configuration). The design makes it ideal for fireplace and space heating applications.

More information

Please keep this manual for f uture reference.

Please keep this manual for f uture reference. GAS WATER/AGUA Congratulations! You've just purchased a new Marey Portable tankless water heater and will soon begin to enjoy the benefits of going tankless. Take the time to thoroughly read and understand

More information

TANKLESS WATER HEATER USE AND CARE MANUAL

TANKLESS WATER HEATER USE AND CARE MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing death, personal injury, or property damage. For Your Safety! Do not store or use gasoline

More information

BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL

BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL BLUE FLAME VENT-FREE PROPANE/LP GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL CGP20TB CGP20TLB CGP30TB CGP30TLB 20,000 Btu/Hr Thermostat and 30,000 Btu/Hr Thermostat Model Heaters WARNING: If the

More information

37E73A-903 & 906 INTELLI-VENT

37E73A-903 & 906 INTELLI-VENT 37E73A-903 & 906 INTELLI-VENT Water Heater Thermostat Control Installation Instructions For Natural Gas Only Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.

More information

Instantaneous gas water heater

Instantaneous gas water heater Instantaneous gas water heater Models W 125...T1 installation operation maintenance The Bosch instantaneous water heater is a high efficiency, space saving answer to your water heating needs. All Bosch

More information

Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005

Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005 Assembly Instructions & User s Manual Triton Classic Gas & Charcoal Grill Model #: FSOGBG3005 Please keep this instruction manual for future reference Customer Service: (888) 922-2336, 7:00 am to 12:00

More information

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

30 GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners) INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do

More information

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER. Instruction Manual RESIDENTIAL GAS WATER HEATERS FOR USE ONLY IN MANUFACTURED HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons with input rating

More information

PARTS NEEDED FOR CONVERTING FROM LP TO NG

PARTS NEEDED FOR CONVERTING FROM LP TO NG 1 6 7 8 3 5 4 10 9 2 PARTS NEEDED FOR CONVERTING FROM LP TO NG Number Description 1 30" NG Manifold 2 NG side burner valve 3 NG Regulator 4 Rear I/R NG orifice 4 Rear I/R NG orifice 5 Side burner NG orifice

More information

OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000. www.escea.net

OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000. www.escea.net OUTDOOR GAS FIREPLACE USER GUIDE North America 630165_2 EF5000 www.escea.net Any service work carried out on this appliance must only be done by a recognised escea technician or authorized personnel. The

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the information in this

More information

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -

More information

Instruction Manual for Residential Gas Water Heaters

Instruction Manual for Residential Gas Water Heaters Instruction Manual for Residential Gas Water Heaters NOT FOR USE IN MANUFACTURED (MOBILE) HOMES GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons with

More information

LPM-06 CONVERSION KIT

LPM-06 CONVERSION KIT LPM-06 CONVERSION KIT TWO-STAGE FURNACE NATURAL GAS TO L.P. GAS CONVERSION Goodman Manufacturing Company, L.P. 2009-2011 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com

More information

Crux TM. Canister mounted stove for outdoor use SWE OPTIMUS CLEVER COOKING SINCE 1899

Crux TM. Canister mounted stove for outdoor use SWE OPTIMUS CLEVER COOKING SINCE 1899 EN Crux TM Canister mounted stove for outdoor use FR DE NL DK SWE NO FI IT ES PT PL CZ OPTIMUS CLEVER COOKING SINCE 1899 RU FIGURE [1] FIGURE [2] O-ring Art. No. 8017867 FIGURE [3] FIGURE [4] FIGURE [5]

More information

Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español

Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation

More information

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Firewall. Propane flame projector Safety instructions and operating manual

Firewall. Propane flame projector Safety instructions and operating manual Firewall Propane flame projector Safety instructions and operating manual TBF-PyroTec GmbH Lichterfelder Str. 5A 21502 Geesthacht Tel.: +49(0)4152 157 9950 info@tbf-pyrotec.de www.tbf-pyrotec.de 1 Flame

More information

Getting the best from your urn

Getting the best from your urn 444448538 Standard 444448539 Deluxe Getting the best from your urn Remove any plastic film from the urn before use. Any water in the urn is due to testing and is normal. The urn must be used on a flat

More information

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This

More information

OUTDOOR PIZZA OVEN INNOVATIVE DESIGN CREATES CULINARY PERFECTION

OUTDOOR PIZZA OVEN INNOVATIVE DESIGN CREATES CULINARY PERFECTION OUTDOOR PIZZA OVEN INNOVATIVE DESIGN CREATES CULINARY PERFECTION Dear Sloan Outdoors Customer, Thank you for choosing Sloan Outdoor Products. We recommend you read this manual carefully to fully understand

More information

T360 Barbecue. Assembly Manual. 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY

T360 Barbecue. Assembly Manual. 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY T360 Barbecue Assembly Manual 85-3052-6 (G30531) Propane 1 YEAR LIMITED WARRANTY READ AND SAVE MANUAL FOR FUTURE REFERENCE. If pre-assembled, leave this manual with unit for consumer s future reference.

More information

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation

More information

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference. User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve

More information

Select Radiators Installation Guide

Select Radiators Installation Guide Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall

More information