IMMUNITY TESTING FOR THE CE MARK By Rodger Gensel, Product Line Applications Specialist



Similar documents
AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Test Report #: Date: April 8, 2005

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison

Technical Article MS-2443

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Dual Chamber Temporary External Pacemaker

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

15 Series - Electronic step relay and dimmer. Features SERIE

EMC Test for Compliance with EU EMC Directive 2004/108/EU

STRATO LED Drivers 70W, Single output

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

IEC and CISPR Standards

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

30 In Compliance October

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

38 Series - Relay interface modules A

Waveguide Access Point WGA631. Product Guide

Cable Analysis and Fault Detection using the Bode 100

Rack mounted telephone- and leased line modem for industrial applications

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Current Probes. User Manual

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

English version. Voltage characteristics of electricity supplied by public distribution systems

Analysis of Immunity by RF Wireless Communication Signals

NUP2105L, SZNUP2105L. Dual Line CAN Bus Protector SOT 23 DUAL BIDIRECTIONAL VOLTAGE SUPPRESSOR 350 W PEAK POWER

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Cable Solutions for Servo and Variable Frequency Drives (VFD)

38 Series - Relay interface modules A

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Electromagnetic Compatibility Considerations for Switching Power Supplies

CAN bus ESD protection diode

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

MasterINTERFACE 39 Series - Relay interface modules

Three-phase monitoring relay CM-PFE

ANSI Watthour Meter Testing & Certification Programs

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

RX-AM4SF Receiver. Pin-out. Connections

A Beginners Guide to EMC. Presented by Andy Lawson Technical Supervisor, Industry EMC, TÜV SÜD Product Service

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

White Paper: Electrical Ground Rules

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

Power surges can also be generated by equipment in your facility such as:

Line Reactors and AC Drives

80 Series - Modular timers 16 A. Features

AN-2 TEN KEY CONSIDERATIONS BEFORE YOU START YOUR DAA OR FXO PHONE LINE INTERFACE DESIGN

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Adding Heart to Your Technology

PESDxU1UT series. 1. Product profile. Ultra low capacitance ESD protection diode in SOT23 package. 1.1 General description. 1.

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

7. Technical Notes Table of Contents

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

Telephone- and leased line modem for industrial applications TD-36

Current Probes, More Useful Than You Think

LC05-6. Dual Low Capacitance TVS Array for Telecom Line-Card Applications. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

Combination Wave Test System

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

40 Years of experience in EMC testing

LIN-bus ESD protection diode

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Energy Management Energy Meter Type EM23 DIN

with Component Rating A Simple Perspective

Exploring the Necessity of the Hot Hipot Test

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications

MasterINTERFACE 39 Series - Relay interface modules

Features. Picture. Specifications

Power Quality for Information Technology System

TECHNICAL TBR 12 BASIS for December 1993 REGULATION

Analog signal converters CC-E I/I Current / current isolators

The impact of the New EMC Directive 2004/108/EC

User Manual. CFG253 3 MHz Function Generator

Transcription:

IMMUNITY TESTING FOR THE CE MARK By Rodger Gensel, Product Line Applications Specialist SUMMARY The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half billion people. In 2005, the total exports to the EU accounted for 20% of the total US exports. This number should continue to grow and should create more business for US exporters in years to come. Since January 1, 1996, manufacturers of electronic equipment have had to meet the Electromagnetic Compatibility (EMC) guidelines of EC Council Directive 89/336/EEC when shipping electrical and electronic products to the EU. Manufacturers must test and certify that their equipment meets the directive and they must apply a CE mark as testimony to this. Current and pending changes to the specifications that describe the tests to be made, place more stringent requirements on the equipment used for CE mark testing. Indeed, future changes will require that the testing equipment be able to expand its capabilities without causing the equipment to become useless. INTRODUCTION The legally prescribed test requirements for EMC standards in the EU are issued by CENELEC, the European Committee for Electrotechnical Standardization. CENELEC issues both Generic and Product standards. The generic standards are EN 61000-6-1, which addresses the requirements for immunity testing in the residential, commercial and light industrial environment. The industrial environment immunity testing required is addressed by EN61000-6-2. The generic standard for emission requirements in the residential, commercial and light industrial environment is covered in IEC 61000-6-3 and the industrial environment is addressed in EN 61000-6-4. The generic standards above apply to products for which no dedicated product or product-family standard exists. If a product or product-family standard exists, it takes the place of the generic standards in prescribing the test requirements. The generic and product-family standards outline the test requirements. They refer to what is known as the Basic Standards to define the tests to be performed, the test methods, the test set-up and the specifications of the generator used to simulate interference phenomena. The International Electrotechnical Commisson (IEC) writes the basic standards to which CENELEC refers in their EN's. This article will focus on five of the European Standards from CENELEC used in the immunity portion of the standards, four of which are required by the generic standards for CE mark certification. BASIC STANDARDS FOR EMC IMMUNITY The IEC promotes standardization in the fields of electricity, electronics and related technologies. IEC 61000 part 3 covers emission specifications and IEC 61000 part 4 covers immunity specifications. The specifications are further broken down into sections. CENELEC has also adopted the same numbering system and refers to the specifications as EN's or European Norms. They are EN 61000-3 and EN 61000-4. The immunity portions of the specifications are listed below in Table 1. 1 of 8

Table 1-Basic Standards EN 61000-6-1 and EN 61000-6-2, Generic Immunity Standards refer to: EN 61000-4-2 IEC 61000-4-2 Electrostatic Discharge (ESD) EN 61000-4-3 IEC 61000-4-3 Radiated EM Field EN 61000-4-4 IEC 61000-4-4 Burst-Electrical Fast Transients (EFT) EN 61000-4-5 IEC 61000-4-5 Surge EN 61000-4-6 IEC 61000-4-6 Conducted Radio Frequency disturbances EN 61000-4-8 IEC 61000-4-8 Power frequency magnetic field EN 61000-4-9* IEC 61000-4-9* Pulse magnetic field EN 61000-4-11 IEC 61000-4-11 Voltage dips, interruptions *EN 61000-4-9 and IEC 61000-4-9 are not required by the Generic Standards but are referenced here for later use in this application note. INTERFERENCE GENERATION The Basic Standards also specify the generator to be used for simulating the interfering phenomena. But, since the disturbance phenomena have to be determined and measured first, the Basic Standards and the generator requirements usually lag behind the real environmental conditions. Consequently, the standards are subjected to constant changes. To reduce the cost of the generator used for testing to the immunity standards, it must be versatile and capable of covering as many of the foreseen specification changes as possible. Testing of one's own product is a requirement for the CE mark. This viewpoint is satisfactory; however, immunity testing of a manufactured product is also valuable as a tool to achieving customer satisfaction with the end product. If a product is not susceptible to ESD and fast transients for instance, it will not fail as readily during normal use. This is not only important from a performance standpoint, but from a safety and legal liability standpoint as well. Therefore, it is useful to use interference generators in the product design and development stage, as well as in the CE mark certification process. BURST The burst pulses, also called electrical fast transients (EFT), are created on public power lines by electrical arcs across switch contacts during opening of the switch. The nature of the loads connected to the power lines causes short bursts of pulses across the switch, which can generate interference in electrical/electronic equipment connected to the lines. Figure 1 shows the bursts called out by IEC 61000-4-4. The most recent version of the burst standard is IEC 61000-4-4:2004 Ed 2. The pulses within the 15-millisecond burst period are defined by the specification as having a frequency of 5 KHz. The latest edition of the standard added 100 KHz as a new frequency and the burst duration for this pulse will be 0.75 millisecond. The reduction in the burst duration is due to the energy content having to remain the same as the 5 KHz pulse. The burst pulses are applied in peak voltage levels from 500 volts to 4 KV on the power supply lines of the equipment under test (EUT). Because the burst pulses can be radiated into equipment signal lines (from nearby power leads), the burst pulses are also required to be capacitively coupled to the signal leads. 2 of 8

5/50 SPIKE SWITCH Voltage across switch on opening SPIKE 300ms 15ms 50ns 5ns BURST GENERATION FIGURE 1: FAST TRANSIENT/BURST PULSES The burst test is a low energy test, and as such, it is not destructive. The burst test is particularly hard on complex digital equipment with high clock frequencies. The test can cause degradation of performance, loss of function, uncontrolled process sequences, failures in programmable equipment, loss of information stored in memory and incorrect data processing. For these reasons, the burst test should be the first test performed on an EUT. In order to take into account constantly increasing clock frequencies of microprocessor applications, higher burst pulse frequencies exceeding the 5 KHz specified frequency and even higher than the 100 KHz proposed frequency should be used in developmental testing. If the burst testing were done at 5 KHz, it would take many tests to find and isolate a burst susceptibility design problem. If, for example, the EUT were to have a clock frequency of 10 MHz, the 5 KHz burst pulse tests only every 2,000th function state. The test piece's critical states are likely to be among the 1,999 function states not tested. If the testing is done at 100 KHz, the design problems can be more quickly discovered because 20 times as many function states are tested in any given testing time. CENELEC has also added new requirements related to pulse verification and calibration of the burst generator. These are included in Ed 2 of the IEC 61000-4-4 standard. According to Amendment A2:2001 to the IEC 61000-4-4:1995 standard, test generators must meet the verification and calibration requirements effective July 1, 2004. The changes made require that the burst pulse be verified at the generator coaxial output into an open circuit (1000 ohms) and into a 50-ohm load. Newly added to the Ed 2 standard, the burst verification also needs to be performed at the generator coupling/decoupling output with a 50 ohm load. Because of the high frequency character of the burst pulses, to reduce stray capacitance, a special coaxial adapter (see Figure 2 below) and a minimum 400 MHz bandwidth oscilloscope is required to make the pulse verification. The specification changes were made to achieve more uniform pulse characteristics among the various transient generator manufacturers and to provide repeatable test results. 3 of 8

FIGURE 2: COAXIAL ADAPTER FOR BURST PULSE OBSERVATION Since the burst test is relatively easy to set up and its reproducibility is high, the test is suitable for inhouse developmental testing. SURGE IEC 61000-4-5 prescribes tests for simulating the effects of lightning discharges as well as voltage surges caused by switching disturbances in power stations. The surge waveforms are defined by the specification as shown in Figures 3 and 4 below. The peak voltage for the voltage waveform in Figure 3 varies between 500V and 4.0KV. The peak current in Figure 4 is between 250A and 2.0KA. 4 of 8

FIGURE 3: WAVEFORM OF OPEN CIRCUIT VOLTAGE (1.2/50 μs) FIGURE 4: WAVEFORM OF SHORT CIRCUIT CURRENT (8/20 μs) IEC 61000-4-5 requires that the generator be capable of applying surge pulses at a rate of "at least one per minute". The surge pulse must be applied at 0, 90, 180, and 270 degrees of the power input waveform. This requires that the surge generator be synchronized to the AC input. The surge pulses must be coupled from line to line and from the line(s) to earth of the power leads. The peak voltage level of the surge pulse is adjusted in steps starting at 500V to 4000V. In total, 600 pulses are required. The simulator must have sufficient energy available to complete this test in a timely matter because if a generator just meets the bare minimum requirement of one pulse per minute, the test will take 10 hours total. If the generator is capable of providing surge pulses faster than one per minute, the test time can be reduced. This assumes the EUT itself is designed to handle the faster surge pulse repetition rate. The surge test can be destructive to the EUT if adequate protection is not incorporated into the design. Therefore, this test should be carried out only after a successful burst test so that if the EUT is destroyed, the tester at least has some useful test data. The coupling and decoupling networks for applying the burst and surge pulses are usually contained within the surge generator. For coupling to the signal leads for both burst and surge pulses, external coupling clamps or networks are required. POWER FAIL SIMULATION IEC 61000-4-11 specifies the levels for testing supply line dips, interruptions and variations. Faults in the power distribution networks, brownouts or sudden large changes in the load on the lines cause voltage dips and short interruptions. The line voltage variations are caused by continuously varying loads connected to the network. These phenomena occur randomly. When large rotating machines are connected to the network, they can act as generators on the power lines during interruptions resulting in gradual variations in the line voltage rather than abrupt interruptions. The line voltage dips and interruptions are required tests of IEC 61000-4-11, but the voltage variations test in the IEC standard are optional dependent on the EUT product specification and the product's sensitivity to voltage variations. 5 of 8

The specifications for the voltage dips and short interruptions are given in Tables 2 and 3 below. Table 4 shows the optional power supply variations test levels. TABLE 2 - Test Levels for Voltage Dips and Interruptions TABLE 3 Test Level and Durations for Short Interruptions TABLE 4- Timing of Short-Term Supply Voltage Variations For dips and interruptions, the transient generator usually contains built-in electronic switches to switch in the appropriate voltage dip or interruption. The generator controls must allow adjustment of the phase, synchronization and duration of the dips and interruptions. 6 of 8

POWER FREQUENCY MAGNETIC FIELD AND PULSE MAGNETIC FIELD IMMUNITY TESTING IEC 61000-4-8 describes the tests and levels for power frequency magnetic fields and IEC 61000-4-9 defines the tests and levels used for pulsed magnetic field immunity testing. These two specifications are grouped together because they are very similar. Magnetic fields can affect the reliable operation of electrical and electronic equipment. The power frequency magnetic field simulates power frequency current in conductors or leakage from transformers or other current carrying conductors in the area. Pulse magnetic fields are generated by lightning strikes on buildings and other metal structures near electrical or electronic equipment. The generic immunity standards now require that IEC 61000-4-8 testing be completed for the CE mark. IEC 61000-4-9 is only a requirement of some product specifications at this time. The products usually tested to IEC 61000-4-9 are railroad equipment and those products associated with power sub-stations. One way to test for the power frequency magnetic field requires an external one meter square coil and a current transformer to drive the square coil. One configuration using this method for power frequency magnetic field immunity testing is shown below in Figure 5. POWER COMBINATION WAVE GENERATOR Control Control Power VOLTAGE H Field A/m MOTORIZED VARIAC CURRENT TRANSFORMER ANTENNA 1mx1m FIGURE 5: Power Frequency Magnetic Field Testing Connecting the surge current output of the transient generator directly to the external one-meter square coil generates the pulsed magnetic field. The generator controls are used to adjust the level of current through the coil to the proper magnetic field level. Figure 6 below shows the test diagram. POWER COMBINATION WAVE GENERATOR HV SURGE PULSE DUT ANTENNA 1mx1m FIGURE 6: Pulsed Magnetic Field Testing 7 of 8

ELECTROSTATIC DISCHARGE IMMUNITY TESTING The pulse waveform generated for ESD simulation is a very fast transient pulse up to 15KV in amplitude and containing high impulse current. Because of this, the test can be very destructive in nature. ESD testing should be completed after EFT testing to insure that the EUT has a solid board layout, satisfactory lead dress and a proper grounding system to reduce the possibility of EUT damage from the ESD pulse. The set-up and application of ESD testing is critical. Because of this testing complexity, a specific description of ESD testing is out of the scope of this paper (refer to figure 5 of IEC 61000-4-2). In fact, the subject of ESD testing is worthy of an entire paper of its own. CONCLUSION CENELEC refers to basic standards issued by the International Electrotechnical Commission (IEC). CE Marking requires emissions and immunity testing. This paper addresses some of the immunity tests required by the generic standards. The basic standards describe the transient phenomena waveforms characteristics and the generator characteristics used to simulate the transient waveforms in the test environment. Testing electrical and electronic products to achieve the CE Mark requires using test generators that simulate the transient phenomenon a occurring on power lines. Transient generators are available which incorporate the ability to test burst, surge, magnetic field and voltage dips and drops in one package to simplify the test engineer's task. Recent changes in the generic and basic standards require that the generator be chosen with the ability to meet the new specification requirements. 8 of 8