How To Make A Feedback Decoder For A Model Railroad

Similar documents
BMD16N-SD. version 1.2

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

step 1 Unpack the lunchbox And check whether you have got all the components~ If you have questions please contact us at: info@unitunlikely.

Multi-Protocol decoder with Load regulation

BUILDING INSTRUCTIONS

PolyBot Board. User's Guide V1.11 9/20/08

How to connect to a Class II router using a mobile-phone data cable specifically for Solwise & Safecom routers

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

GLOLAB Universal Telephone Hold

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

WHO ANSWERED FIRST? FIND OUT WITH THIS QUIZ BUZZER KIT

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

DIY Y6. Build Manual V.A 2014

15 Channel IR transmitter. Total solder points: 53 Difficulty level: beginner advanced K8049 ILLUSTRATED ASSEMBLY MANUAL

VOLUME AND TONE CONTROL - PREAMPLIFIER K8084

Bill Conkling July 2012

RS232/DB9 An RS232 to TTL Level Converter

K6002 TEMPERATURE CONTROLLER. Specifications

400W MONO/STEREO AMPLIFIER

GUITAR PREAMPLIFIER WITH HEADPHONE OUTPUT K4102

User manual DinaSys DTC/DTS and DTC/DTZ

Total solder points: 67 Difficulty level: beginner advanced UNIVERSAL TEMPERATURE SENSOR K8067 ILLUSTRATED ASSEMBLY MANUAL

Assembly Instructions: Shortwave Radio Kit

Cumbria Designs T-1. SSB/CW Filter kit (4.9152MHz) User Manual

THE ELECTRONIC DICE. a technology project for secondary education. Name: Class:

Clio 2 Pictorial Installation Guide

Functioning. Layout Diagram. Technical Data. Connection Diagram Fixing the Battery Clip Inserting the Panel for the Slide Switch

PC FUNCTION GENERATOR

solutions for teaching and learning

7-SEGMENT DIGITAL CLOCK

Total solder points: 115 Difficulty level: beginner advanced 4 CHANNEL RUNNING LIGHT K8032 ILLUSTRATED ASSEMBLY MANUAL

ALARM SYSTEM INSTALLATION GUIDE

AUTOMATIC CALL RECORDER JAMECO PART NO

Modifying the Yaesu FT-847 External MHz Reference Input

AXE114S BINARY CLOCK. revolution Revolution Education Ltd. Web: Version /09/08 AXE114.PMD.

K8068 BUS DIMMER FOR HOME MODULAR LIGHT SYSTEM ILLUSTRATED ASSEMBLY MANUAL H8068IP-1

Slot.it Audi R8C Snetterton

Overnight Sensations Speaker Kit

Soldering is easy. here's how to do it. Andie Nordgren (Comics adaptation) Jeff Keyzer. by: Mitch Altman (soldering wisdom) (Layout and editing)

Building A Computer: A Beginners Guide

Analog control unit for mobile robots

QUASAR ELECTRONICS KIT No ELECTRONIC MOSQUITO REPELLER

Electronic Circuit Construction:

TEACHING RESOURCES SCHEMES OF WORK DEVELOPING A SPECIFICATION COMPONENT FACTSHEETS HOW TO SOLDER GUIDE GET IN TUNE WITH THIS FM RADIO KIT. Version 2.

Bill of Materials: Line Follower: A Zippy Robot That Senses Where to Go PART NO

Micrio WS1 Replacement Wind Speed Sensor and WC1 Replacement Wind Compass Sensor for Raymarine ST50 and ST60 Wind Instruments. Rev 4.

POCKET AUDIO GENERATOR K8065

Juice Box Stages 1&2 135&335 Installation Guide 5/10/08

DIGITAL PC SCOPE. Total solder points: 625 Difficulty level: beginner advanced K8031 ILLUSTRATED ASSEMBLY MANUAL

The $25 Son of a cheap timer This is not suitable for a beginner. You must have soldering skills in order to build this kit.

Tutorials Drawing a 555 timer circuit

LocoNet, the Digitrax Difference

200W DISCRETE POWER AMPLIFIER K8060

Multi-Protocol decoder

ECEN 1400, Introduction to Analog and Digital Electronics

Electronics and Soldering Notes

3 Slot Payphone Controller

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

!Operation:!1. Connect an external power source to J1 (+ and - IN terminals). The

TEECES DOME LIGHTING SYSTEMS

Fitting a Hornby 4 Function Decoder and a PCB Lighting Board to a Hornby Inter City 125 (HST) The lighting board is made by Black Cat Technology

Switch board datasheet EB

Assembly and User Guide

Transfer of Energy Forms of Energy: Multiple Transformations

Capacitive Touch Sensor Project:

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

Electronic Circuit Prototyping Techniques

BUILD YOUR OWN RC SWITCH (Issue 3)

K4401 SOUND GENERATOR. them at the touch of a button. Specifications

Kit Watt Audio Amplifier

Every so often, a. Diagnosing ECUs, Part I: Visual Inspection and Common Failures. by Mike Van Dyke

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008

Smartphone garage door opener

Triac Printed Circuit Board Replacement

K8025 VIDEO PATTERN GENERATOR. Check the picture quality of your monitor or TV, ideal for adjustment or troubleshooting.

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Installation Guide for Artic Air 24 Volt R134A Air Conditioner

MegaRAID LSIiBBU09 Intelligent Battery Backup Unit

POWER WAVE 455M/STT & (CE)

MTH SD70ACe DCC Ready Soundtraxx AT-1000 EMD 710 Sound Decoder Install Revised June 1, 2011

K2570 UNIVERSAL POWER SUPPLY 5-14DC / 1A. The easy way to power your ILLUSTRATED ASSEMBLY MANUAL

ARDUINO SEVERINO SERIAL SINGLE SIDED VERSION 3 S3v3 (REVISION 2) USER MANUAL

MAINS VOLTAGE DETECTOR K7101

Name: Bicycle Cellphone Charger Circuit Assembly Manual Device: Nokia/Blackberry List of Components:

KNX Interface. User Manual PM00A00IRI

ENGS 32 Winter, Prototyping Methods

Acceptability of Printed Circuit Board Assemblies

Glolab Talking Phone Dial Monitor

Review of. 4x IOcards (PCBs) Manufactured by Opencockpits

Total solder points: 18 Difficulty level: beginner advanced UNIVERSAL POWER SUPPLY 5-14DC / 1A K2570 ILLUSTRATED ASSEMBLY MANUAL

DUAL ELECTRONIC DICE K3400

Step by step guide to installing your own Ku Band satellite dish

The RSGB Centenary Receiver Project Construction Manual

GLOLAB Two Wire Stepper Motor Positioner

Total solder points: 205 Difficulty level: beginner advanced UNIVERSAL BATTERY CHARGER / DISCHARGER K7300 ILLUSTRATED ASSEMBLY MANUAL

Combi B Alarm box. Mounting instructions

Power Window/Power Lock Installation. To begin with you will need all the parts listed below:

Instruction Manual. This Manual covers the use of: SmartSwitch Servo Kit. DCC Stationary Decoder PLEASE READ THESE INSTRUCTIONS FULLY BEFORE USE

Ocean Controls RC Servo Motor Controller

Transcription:

BMD16N version 1.2 Feedback decoder with 16 contacts for the S88-bus Compatible with a.o. Märklin Digital, Uhlenbrock Intellibox, Fleischmann Twin-Center and LDT HSI-88 Compatible with the s88-n standard For ground detection, reed contacts, contact tracks, etc. at digital model railroads in all scales

The BMD16N All computer controlled model railroads need a good system providing feedback from the track. The BMD16N was especially designed to provide this feedback reliably and affordably. The BMD16N is fully compatible with the widespread S88-bus and the new s88-n standard. Sturdy screw terminals The BMD16N is fitted with practical screw terminals. You do not need to fiddle around with expensive model railroad plugs anymore. The connections are easily made and are highly reliable. Universal standard with reliable cables The BMD16N can be connected to your system via normal S88 cables or via UTP network cables. Network cables are cheaper and provide better protection from electrical interference. The cables can be much longer than normal S88 cables. The BMD16N is fully compatible with the s88-n standard, It can be connected directly to any equipment bearing the s88-n logo. Less chance of feedback errors The BMD16N is equipped with an improved circuit. This feature plus the use of network cables will reduce the chance of false feedbacks from your layout. Connect other decoders sideways If mount several BMD16Ns and/or BMD16N-SDs right next to each other, you will need only a simple print connector or just a few wires to connect the decoders. You do not need any cables between the decoders. This will save you wiring, space and money. Attractive kit The BMD16N is an easy to assemble alternative to similar decoders and kits on the market. The BMD16N is cheaper than feedback decoders from model railroad manufacturers. The professionally made circuit board can be assemble by virtually anybody and the components are available just about everywhere. Attention: The connectors on the BMD16N are not normal network plugs. Never connect the decoder to a PC or any other network device! Manual BMD16N version 1.2 - page 2

Feedback and train detection The BMD16N has 16 contacts that are activated when you connect them to the ground terminal of your digital system. This is the case in many situations. For example when you have a 3-rail layout and you are using ground detection for occupancy detection. Or when you are using reed contacts or special contact tracks. The BMD16N also offers you the possibility to create a layout plan track control that drives the software on your PC. The switches are connected to the BMD16N and the actions are passed to the system via the S88-bus. Ground detection Using a technique best described as ground detection is the most reliable way of creating track occupancy detection with 3-rail layouts. Creating detection sections is very easy with Märklin K-track. Normally both rails are used for ground and the centre studs for power. When you use only one rail for ground, the other becomes available for train detection. The free rail is divided into sections with plastic rail joiners (e.g. Roco or Fleischmann). The sections can be as long or as short as you want. Each section will act as an occupancy detector and is connected to another input of the BMD16N. Normally the free rail will not be connected to anything except the decoder. The section is flagged as being free. When a locomotive or a car is in the section, its wheels will connect both rails. The free rail is now connected to ground and the section is flagged occupied. On turnouts you should always connect both tracks to ground and not use detection. Small locomotives might else stall on the turnout. Alternatives Creating detection sections is a bit more complex with C-track, because you will have to cut all the connections between the rails. If you do not want to do that, you can always settle for current detection with the BMD16N- SD. The drawback is that only rolling stock with a pick-up shoe will be detected. Other alternatives are reed contacts and contact tracks. However they are not as reliable as ground detection or current detection. Manual BMD16N version 1.2 - page 3

The parts You can order the parts from Conrad (www.conrad.com) or Reichelt (www.reichelt.de). Or buy them from your local electronics shop. Count Description Conrad nr. 1 resistor 330 Ω 403199 17 resistor 10 kilo Ω 404160 (100 pieces) 2 resistor 100 kilo Ω 403490 1 resistor 220 kilo Ω 403539 4 resistor network 4 x 100 kilo Ω 416053 16 capacitor 10nF 453064 1 capacitor 100 nf 453358 1 LED 3 mm green 184713 1 transistor BC517 154695 6 16 pin IC socket 1 189529 4 IC 4044 172871 2 IC 4014 172707 6 3-pole screw connector 731891 1 connector strip 736942 2 RJ45 western connector 716148 1 Only needed if you want to mount the ICs in sockets. Assembling the decoder You do not have to be a soldering virtuoso to put the BMD16N together, but it is good to have at least some experience. Use a small soldering iron and thin solder with a resin core. Never ever use flux or another soldering agent. Heat the spot with the soldering iron and then apply the solder. The joint is ready when the solder forms a tiny mountain (instead of a blob). Cut away the excess leg after the joint has cooled down. Suggestions Resistor are cheaper when you buy them in a package of a 100 pieces. The resistors of 100 kilo Ω are listed as a package of 100 pieces. If you are assembling more than one decoder, be sure not to order too many resistors by mistake. Another option to save money is to leave out the IC sockets and to solder the ICs directly onto the board. Manual BMD16N version 1.2 - page 4

Assembly The circuit board has a white print on the component side. The print will tell you exactly where each component has to go. The lowest parts are put in first, the highest parts last. This order makes it easy to flip the board over and solder the parts without the need of holding them into place. 1. Resistors The decoder has several resistors from different values. Resistors are indicated by a small rectangle with a number in it. For example, a rectangle with 330 indicates a 330 Ohm resistor. The colour code on the resistors denotes the value. The direction of assembly is not important as long as the legs are in the right holes. Please note: if you plan to connect the decoder to +12 Volt, you should replace the 330 Ω resistor by a 1 kilo Ω one. Used values: 330 330 Ω orange-orange-brown 10k 10 kilo Ω brown-black-orange 100k 100 kilo Ω brown-black-yellow 220k 220 kilo Ω red-red-yellow 2. Resistor networks Part of the resistors come pre-packaged as a resistor network of four resistors. The small black trips have five pins, of which one is a common connection. This pin is indicated with a dot and should go into the hole marked with 1. Or in other words: it should point to the left. Manual BMD16N version 1.2 - page 5

3. IC sockets The IC sockets have a notch on one side. The notch indicates where pin 1 of the IC goes later. When mounting the IC sockets the notch of the socket should be on the same side as the notch in the white print. 4. Capacitors The decoder has 16 capacitors of 10nF (marked 103) and 1 of 100 nf (marked 104). The capacitors are indicated by rectangles with 10nF and 100n next to it. The direction of assembly is not important. Manual BMD16N version 1.2 - page 6

5. LED The LED comes in the middle of the board. The longer leg should be in the hole marked with +. 6. Transistor A semicircle with BC517 marks the place of the transistor. The flat side of the transistor should point to the bottom of the board. 7. Screw connectors The screw connectors come in blocks with three contacts. The sides have slits. First click the connectors together to form one long row and then solder them to the board. 8. S88-bus connectors Cut two pieces with six contacts from the long strip connector if needed. The location of the two strips is clearly marked on the board. You can leave out these connectors if you only plan to use network cables. 9. RJ-45 connectors The connectors should firmly click into the holes. You can leave out the connectors if you plan on only using the standard S88 cables. Manual BMD16N version 1.2 - page 7

10. ICs You can now press the ICs very gently into the sockets. The text below the socket tells you which IC goes where. The right direction is critical. A notch or dot indicates pin 1 of the IC. This side should correspond with the notch of the IC socket. Please note that all ICs are pointing in the same direction! Final check Congratulations, your board is now ready. Please review your assembly carefully. Are all components in the right place? Are the ICs and the transistor mounted in the right direction? Are all joints soldered correctly and are there no short-circuits? If everything checks out fine, you can connect the BMD16N to your system. Revisions The circuit board might have been updated since the pictures of this manual were taken. Your board might look slightly different from the one in the manual. Please place your components according to the markings on your board wherever they differ from the ones in the pictures. Manual BMD16N version 1.2 - page 8

Connecting your BMD16N Connecting to a central unit The first BMD16N is connected to the S88 bus on your central unit. The cable is connected to the decoder on the side labelled richting centrale. When your decoder is connected correctly, the green LED will come on. It is recommended to use the s88-n adapter (sold separately). This small adapter changes the standard S88 connection on your central unit into a s88-n connection. Instead of a normal S88 cable, you can now use a reliable and inexpensive network cable to connect your first decoder. Manual BMD16N version 1.2 - page 9

volgende module PWR www.floodland.nl/aim naar centrale volgende module PWR www.floodland.nl/aim naar centrale volgende module PWR www.floodland.nl/aim naar centrale More decoders Successive decoders are connected in a chain by preferably a normal network cable (NOT a cross cable). Or else using a standard S88 cable. You can use the s88-n adapter to make decoders with only a standard S88 connection s88-n compatible. This allows you to wire your entire chain of feedback decoders with network cables. The arrows on the decoder indicate the direction of the flow. The order of the decoders determines how the contacts are numbered. The first decoder has contacts 1 to 16, the second one 17 to 32, and so on. The BMD16N can be combined with other brands of decoders in any order. With most central units you can connect up to 31 decoders with 16 contacts to the S88 bus. 33 t/m 48 17 t/m 32 1 t/m 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 (c) 2008 Huib Maaskant - Eddy de Boer (c) 2008 Huib Maaskant - Eddy de Boer (c) 2008 Huib Maaskant - Eddy de Boer BMD16N BMD16N BMD16N intellibox Connecting contacts The BMD16N has 16 contacts that change their state when they are connected to the ground terminal of your digital system. If you have a 3-rail layout, you will want to use the BMD16N to detect your trains via ground detection. This is by far the most reliable form of train detection for Märklin layouts. You can also settle for reed contacts or special contact tracks. However they are not as reliable as ground detection and you cannot use them to detect a car that was left behind. Finally you can connect switches to the BMD16N, e.g. in a layout plan track control or as an emergency stop switch in combination with your software. You can use any type of relay or switch, as long as it switches to ground. Manual BMD16N version 1.2 - page 10

(c) 2008 Huib Maaskant - Eddy de Boer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PWR BMD16N volgende module www.floodland.nl/aim naar centrale Switch Reed contact intellibox Ground detection Contact track Manual BMD16N version 1.2 - page 11

More information is available at www.floodland.nl/aim. Building the BMD16N is completely at your own risk. The creators do not accept any responsibility for damages in any form that might result from building or using this electronic device. 2008, 2012 Maaskant en Eddy de Boer Manual BMD16N version 1.2 - page 12