Cleanrooms and clean manufacturing areas. Coating systems for cleanrooms and clean manufacturing areas Floor-wall-ceiling



Similar documents
Tecnoepo Flooring System 185

Wecryl Waterproofing System under surfacing supplied by others

Cleanroom suitability certifications HOMOGENEOUS VINYL TILE

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

DECLARATION OF PERFORMANCE

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

The bonded waterproof membrane, which can be verified by non destructive means DENSARE /14 IHö/JP/KK

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

European Technical Assessment ETA-16/0277 of 19/05/2016

2-part Epoxy primer, levelling mortar and intermediate layer

Hygiene Standards for all Food Businesses

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Lapping and Polishing Basics

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

flooring sin materiali protettivi milano

Retail Price List 2015

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Concrete Repair. Applications and Procedures

AIR-HANDLING-UNITS FOR THE CHEMICAL / PHARMACEUTICAL SECTORS

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

WATERPROOFING OF WET ROOMS

Polyurea Coatings in Secondary Containment with National Technical Approval. Jürgen Magner Kiwa Polymer Institut Flörsheim / Germany

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

AkzoNobel Aerospace Coatings. Aerowave. Series Next generation structural waterborne coatings

RESTORATION + DECORATION OF BALCONIES AND TERRACES. Decorative, Easy to Maintain and Slip-Resistant Surfaces

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

SOLVING SECONDARY CONTAINMENT PROBLEMS

Low viscosity, solvent free elastic adhesive for wood flooring

Profiles for floors of same height Cerfix Projoint

Spetec. Laminar Flow Box. Portable Clean Room Technology

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

The AQUAFIN Approach to Concrete Repair

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

BLACK JACK ALL WEATHER ROOF COATING

Regulations Concerning

Specifications for Programs: 737, 747, 757, 767, 777, 787

European technical approval

HIGHWAYS DEPARTMENT GUIDANCE NOTES ON THE USE OF WATERPROOFING MEMBRANES ON CONCRETE BRIDGE DECKS

Division 9. SignaFlor Pad and Pour Flooring System

Low VOC Performance Protection Systems

WOOD FLOORING ADHESIVES

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

OLDROYD. Interior Walls. Interior Walls. below and above ground. below and above ground

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Environmental Monitoring

PRODUCT DESCRIPTION 29/08/2014

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Chapter 2 Basis of design and materials

MULTI-TIGHT 2K. The New Generation for Waterproofing Buildings

Elastic, 1-part-polyurethane, liquid waterproofing membrane

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

European Technical Approval ETA 13/0526

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

LASER CUTTING OF STAINLESS STEEL

Use of Carbon Nanoparticles for the Flexible Circuits Industry

High Performance Coating Systems THIOKOL. P r i m a r y a n d S e c o n d a r y C o n t a i n m e n t

European Technical Approval ETA-10/0124

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

PANDA SPRAY BOOTH FILTER INFORMATION

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

Lecture 30: Cleanroom design and contamination control

CLEAN ROOM MONITORING REGULATORY STANDARDS

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

SikaBond Adhesive Systems for Floor Coverings. Innovation & Consistency. since 1910

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

Mineral waterproof coating PCI Dichtschlämme

European Technical Assessment ETA-15/0028 of 23/02/2015

Electroplating with Photoresist Masks

Mold Preventing I nterior System

Cable Trays Technical Instructions & Specifications

Ozone in Cooling Towers : Hygiene for us

Concrete Resurfacing. System Guide. by Parchem Construction Supplies

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

Assessment and Solutions for Hole Wall Pull Away in High Tg and High Technology Laminate Materials

Risk-Based Environmental Monitoring. Marsha Stabler Hardiman Senior Consultant Concordia ValSource Wednesday September 17, 2014 FDA/PQRI

Semiconductor Processor Overview The Field - Preparation - Day in the Life - Earnings - Employment - Career Path Forecast - Professional Organizations

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Annex of the certificate (Page 1/6) Accreditation Scope

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Transcription:

s and clean manufacturing areas Coating systems for cleanrooms and clean manufacturing areas Floor-wall-ceiling

It should be noted that the details, illustrations, general technical information, and drawings contained in this brochure are only general proposals and details which merely describe the basic functions schematically. They are not dimensionally accurate. The applicator/customer is independently responsible for determining the suitability and completeness for the product in question. Neighbouring works are described only schematically. All specifications and information must be adjusted or agreed in the light of local conditions and do not constitute work, detail or installation plans. The technical specifications and product information in the Technical Data Sheets and in system descriptions/certificates must be observed. 2 s and clean manufacturing areas

Contents It has to be clean! 4 s and clean manufacturing areas Standards and regulations 6 Classifications bring safety Epoxy resins for ceilings, walls and floors 10 Smooth surfaces and low particle formation coating systems for floors 12 Overview of the floor systems coating systems for walls and ceilings 14 Overview of the wall and ceiling systems Contents 3

It has to be clean! s and clean manufacturing areas Manufacturing under cleanroom or clean conditions is essential for a growing number of companies, in order that they can safeguard their process operations and the quality of their components. The requirements of the various industrial sectors differ significantly. s and clean manufacturing areas are used primarily in the following industrial sectors: Clean rooms Semiconductor industry Photovoltaics Microsystem technology Food industry Pharmaceutical industry Biotechnology Aviation and space industry Clean manufacturing areas Automobile and supplier industries Machine engineering Equipment, which also includes the floor, wall and ceiling coatings, has a significant influence on the room air quality. The different requirements and the necessary properties of the coating systems for these are described below. Cleanliness areas Cleanliness areas are set up to protect sensitive surfaces and items. The purpose of a cleanliness area is to maintain as far as possible the specified cleanliness quality of components, ancillary materials and assem- blies during processing. The cleanliness level should not be reduced by the influence of environmental factors. Bringing contamination into a cleanliness area must be avoided. Any contamination, which is incurred there, is to be kept in check and then eliminated. The design, required measures and method of use for cleanliness areas are based on cleanliness requirements, which are related to the particular product. The critical particle sizes are generally between 5 μm and 1,000 μm. 4 Introduction

The classification of the cleanliness levels in accordance with VDA 19 Part 2 is in 4 levels: Cleanliness level 0 (SaS0): Non-controlled area Cleanliness level 1 (SaS1): Clean zone Cleanliness level 2 (SaS2): Clean manufacturing area Cleanliness level 3 (SaS3): In order to fulfil the requirements from Cleanliness level 1 onwards, floors must have primarily good abrasion resistance (low particle formation on the surface when it is being used), and good mechanical resistance. A smooth surface, which is easy to clean, is also necessary. Depending on the manufacturing process, other properties such as for example chemical resistance, slip resistance, electrical dissipation capability and crack bridging may be added. Coating systems, which are made of epoxy resin or polyurethane and which are also employed in other areas of industry, are normally used up to Cleanliness level 2. Clean rooms A cleanroom is defined as follows in accordance with DIN EN ISO 14644-1 and VDI 2083 Page 1: A room, in which the concentration of airborne particles is controlled, and which is designed and used in such a way, that the number of particles, which have been brought into the room or which have arisen and been deposited in the room, is as small as possible, and where other parameters relevant to cleanliness, such as temperature, humidity and pressure are controlled as required. In contrast to the particle sizes in cleanliness areas, particle sizes of 0.1 μm to 5 μm are relevant here. In order to keep the share of more or less severely contaminated outside air as small as possible, normally rooms or storeys outside the actual cleanroom are used for air circulation. This means that it is also necessary there, that floors, walls and ceilings, which mostly consist of reinforced concrete, have a cleanroom-compatible surface. These measures have a significant influence on the lifespan of the filter elements for the cleanroom. In addition to the quality of the supply air and method of introducing it as well as to the surfaces and personnel, the other critical influencing factor in the cleanliness of a cleanroom is the equipment in the room. The equipment includes internal fixtures and fittings such as walls, doors, ceilings and floors. Significant factors in the cleanroom compatibility of equipment are: Emission of airborne particles Outgassing behaviour Electrostatic discharge properties Cleanability Resistance to chemicals and disinfectants Smooth and crack-free surface Metabolising potential and microbicidity ceiling with Filter fan units Return Air Return air Shaft shaft Return Air Return air Shaft shaft Simplified schematic illustration for semiconductor manufacturing Introduction 5

Standards and regulations Classifications bring safety The requirements of different industrial sectors vary considerably. While a low level of outgassing from equipment is mandatory for the manufacture of semiconductors, this has mostly played no role as yet in the manufacture of pharmaceutical products. There are similarly differences in the particle cleanliness classes between DIN EN ISO 14644-1 and GMP (Good Manufacturing Practice) or cgmp, which applies to the manufacture of human and veterinary medical products. The particle cleanliness classes for air in accordance with DIN EN 14644-1 are divided into Classes 1 to 9, whereby the highest permitted particle count is the lowest in Class 1. In GMP the division is made into Classes A to D, whereby Class A corresponds approximately to ISO Class 5. Airborne particles represent the largest problem for most production processes. AMC (= Airborne Molecular Contamination) is also playing an ever greater role. These are molecular (chemical, non-particulate) substances in a gas or vapour phase within the atmosphere of a cleanroom area, which could have a harmful effect on the product, process, equipment or personnel. Outgassing from equipment materials, such as for example wall/ceiling/floor coatings, can have negative effects to a significant degree. Examples of this are corrosion effects on metallic conductor strips, defects in lithographic processes, shortened service intervals and life cycles of optics, and the alteration of electrical properties of wafers due to undesirable effects. Classification of air purity on the basis of chemical concentration (ACC) ISO ACC class Concentration g/m 3 Concentration μg/m 3 Concentration ng/m 3 0 10 0 10-6 (1 000 000) 10 9 (1 000 000 000) -1 10-1 10-5 (100 000) 10 8 (100 000 000) -2 10-2 10-4 (10 000) 10 7 (10 000 000) -3 10-3 10-3 (1 000) 10 6 (1 000 000) -4 10-4 10-2 (100) 10 5 (100 000) -5 10-5 10-1 (10) 10 4 (10 000) -6 10-6 10-0 (1) 10 3 (1 000) -7 10-7 10-1 (0.1) 10 2 (100) -8 10-8 10-2 (0.01) 10 1 (10) -9 10-9 10-3 (0.001) 10 0 (1) -10 10-10 10-4 (0.000 1) 10-1 (0.1) -11 10-11 10-5 (0.000 01) 10-2 (0.01) -12 10-12 10-6 (0.000 001) 10-3 (0.001) Source: DIN EN ISO 14644-8:2013-06 6 Standards and regulations

Classification of the various air particle cleanliness classes Nomenclature DIN EN ISO EU GMP 14644-1 a) Guideline a) Maximum permitted particle count per cubic metre of air in accordance with DIN EN ISO 14644-1 US Fed. Std. 0.1 µm 0.2 µm 0.3 µm 0.5 µm 1.0 µm 5.0 µm 209E a) 1 10 2 2 100 24 10 4 3 1 000 237 102 35 8 M 1.5 (1) a) 1 240 265 106 35 4 10 000 2 370 1 020 352 83 M 2.5 (10) b) 12 400 2 650 1 060 353 5 1 000 000 23 700 10 200 3 520 832 29 A/B 3 500 M 3.5 (100) b) 26 500 10 600 3 530 6 237 000 102 000 35 200 8 320 293 M 4.5 (1 000) b) 35 300 247 7 352 000 83 200 2 930 C 350 000 2 000 M 5.5 (10 000) b) 353 000 2 470 8 3 520 000 832 000 29 300 D 3 500 000 20 000 M 6.5 (100 000) b) 3 530 000 24 700 9 35 200 000 8 320 000 239 000 Source: VDI 2083, page 1 a) Observe different operating statuses (depicted: Empty running) b) Division into classes in cubic feet Standards and regulations 7

Standards and regulations No testing criteria for equipment, which also includes coating systems for floors, walls and ceilings, have been specified up to now in any standards or guidelines for cleanrooms. There has been only indirect information on the composition of room air to be produced or maintained in cleanrooms. manufacturers and operators have therefore specified the criteria for systems in cleanrooms on the basis of experience. Their own testing procedures have in part been developed, such as for example through the M+W Group with its Specifications for semiconductor cleanrooms. An industry alliance, Suitable Materials (CSM), arose from an initiative by the Fraunhofer Institute for Manufacturing Engineering and Automation (IPA) in Stuttgart, in order to work out testing methods for the cleanroom compatibility of equipment and to develop products, which are optimised for these tasks. Thanks to the knowledge gained by the CSM Industry Association, test criteria for the cleanroom/cleanliness compatibility of materials were described for the first time in the VDI Directive 2083, Page 17 (June 2013). Depending on the area of application, the following requirements are placed on coating systems: Good abrasion resistance (low particle formation) Good mechanical resistance Good chemical resistance Low outgassing Smooth, easily cleanable surface Resistant to disinfectants Biostatic or microbicidal Dissipative Crack-bridging The cleanroom compatibility of coating systems has since been able to be proved by means of testing procedures. This means significantly greater safety for the construction and operation of a cleanroom. Supplementary requirements in biotechnology In laboratories for research, development and microbiological analysis, in which there is contact with microorganisms as part of bacteriology, mycology, virology and parasitology, and/or in which genetic work is being carried out, the main focus is on ensuring, that no microorganisms, which are dangerous to humans, animals, plants or the environment, can escape from the laboratory. These laboratories are classified into four safety levels, S 1 to S 4, in accordance with DIN EN 12128, whereby S 1 is the lowest safety level and S 4 the highest. As regards safety levels from S 3 onwards, the surfaces of work tables, floors, walls and ceilings must be easy to clean and easily accessible for upkeep. The surfaces must be impermeable to water and resistant to disinfectants, cleaning agents, acids, solutions, solvents and other chemicals, which are normally used. Most coating systems have since had to be crack-bridging, so that no microorganisms, which could otherwise remain untouched by wiping disinfection, can become established in any cracks, which may subsequently arise in the building. 8 Standards and regulations

Suitable Materials An industry alliance, Suitable Materials (CSM), was created on the initiative of the Fraunhofer Institute for Manufacturing Engineering and Automation (IPA) in Stuttgart. Testing methods have been developed here to test materials for their cleanroom compatibility. StoCretec GmbH actively collaborates as an Industrial Alliance Member in the further development of suitable materials for the coating of walls/ ceilings/floors. The products have been tested by the IPA in accordance with the CSM test parameters. Further information at www.cleanroomnet.de. Standards and regulations 9

Epoxy resins for ceilings, walls and floors Smooth surfaces and low particle formation Ground Coating systems based on epoxy resin are ideally suited to the requirements of cleanrooms. They have proven themselves primarily due to their smooth surface and very good chemical resistance. They also have very good abrasion performance and therefore very low particle formation, when subjected to mechanical stress such as for example contact with persons or vehicles. The outgassing behaviour has also been further improved in recent years due to targeted selection of material ingredients as part of the development of the products. The latest generation of epoxy resin dispersions or emulsions contain only water and hardly any share of volatile components. Coating systems generally consist of the following work stages: Substrate preparation Primer Levelling layer Finishing coat 4 3 2 1 Wall 4 3 2 1 Substrate 2 Primer 3 Levelling layer 4 Finishing coat 1 Substrate 2 Primer 3 Filling 4 Sealing 1 Substrate preparation by shot-blasting Substrate preparation by grinding Substrate preparation by high-pressure water jetting Holes and shrinkage holes in the prepared concrete surface Closing of holes and shrinkage holes with levelling filler coating 10 System structure

Coatings on floors, walls and ceilings As regards horizontal surfaces subject to vehicle traffic, low-dust shot-blasting has become established in recent years as the most economic procedure for substrate preparation. Grinding with a diamond plate grinder is used on small surfaces and in areas, which are difficult to access. High-pressure water jetting is normally used on large surfaces for walls and ceilings, primarily in new buildings. The primer is an important component part of a coating system, since it ensures that there is a permanent bond between the following coating and the substrate. In the case of reinforced concrete surfaces, there are open pores and shrinkage holes present after the substrate preparation, and these have to be closed by means of a levelling layer, so that they are not transferred to the finishing coat. A self-spreading epoxy resin coating, which is filled with quartz sand, of 1-2 mm layer thickness is generally used as the finishing coat on horizontal surfaces. In the case of wall and ceiling surface areas, which are not exposed to any mechanical stress such as contact with persons or vehicles, sealing with epoxy resin to a layer thickness of 0.1-0.2 mm is generally sufficient. A glass fleece can be worked into the coating system in order to achieve crack bridging. It is strongly recommended, that test surfaces are created in advance of the work, so that a picture of the edge zone of the concrete is formed. Depending on the concrete quality and the quality level of the installation, this can be very variable as regards suction behaviour, surface tensile strength, roughness and frequency of pores and shrinkage holes. Coated wafer table in semiconductor manufacturing Coating with a terrazzo look in a pharmaceutical company System structure 11

coating systems for floors Overview of the floor systems coating systems for floors Floor System 1 Floor System 2 Floor System 3 Floor System 4 Floor System 5 Floor System 6 Substrate Dry concrete Dry cement screed Concrete with increased moisture Cement screed with increased moisture Magnesia screed Calcium sulphate screed Properties Rigid Crack-bridging 0.4 mm 0.4 mm Suitable for vehicle traffic with Vulkollan and polyamide wheels System layer thickness 1.5-2 mm 1.5-2 mm > 2 mm > 2 mm 1.5-2 mm > 2.5 mm Smooth, gloss surface Silk matt, pore-free surface with a terrazzo look Electrically conductive Water vapour permeable System structure Prime coating StoPox GH 205 Scattering with quartz sand 0.3-0.8 mm StoPox GH 205 Scattering with quartz sand 0.3-0.8 mm StoPox WHG Grund 100 and scattering with quartz sand 0.3-0.8 mm StoPox WHG Grund 100 and scattering with quartz sand 0.3-0.8 mm StoPox WG 100 StoPox GH 205, scattering with quartz sand 0.3-0.8 mm Scratch coat StoPox GH 205 and quartz sand StoPox GH 205 and quartz sand StoPox WHG Grund 100 and quartz sand StoPox WHG Grund 100 and quartz sand StoPox WG 100 StoPox BB OS Conductive intermediate StoPox WL 110 StoPox WHG Leit 110 Coating StoPox BB OS StoPox KU 611 StoPox WHG Deck 110 StoPox WHG Deck 100 StoPox WB 100 StoPox BB T 200 Sealing StoPox WL 100 StoPox WL 150 System view 12 Floor systems The detailed technical specifications and information on the products contained in the Technical Data Sheets and approvals must be observed.

coating systems for floors Floor System 1 Floor System 2 Floor System 3 Floor System 4 Floor System 5 Floor System 6 Test certificates Decontaminability»excellent«Outgassing behaviour Particle formation Resistance to disinfectants Resistance to fungi and bacteria Suitability for indirect contact with food Approval 62 WHG The detailed technical specifications and information on the products contained in the Technical Data Sheets and approvals must be observed. Floor systems 13

coating systems for walls and ceilings Overview of the wall and ceiling systems coating systems for walls and ceilings Wall/ Ceiling System 1 Wall/ Ceiling System 2 Wall/ Ceiling System 3 Wall/ Ceiling System 4 Wall/ Ceiling System 5 Substrate Dry concrete Concrete with increased moisture Render of mortar group 2 Render of mortar group 3 Gypsum plasterboard Properties Rigid Crack-bridging 0.4 mm 0.4 mm System layer thickness 1.5-2 mm 1.5-2 mm 1.5-2 mm 1.5-2 mm 1.5-2 mm Smooth, gloss surface Water vapour permeable System structure Prime coating Concrete: StoPox WG 100 Concrete: StoPrim Plex Render: StoPrep In Concrete: StoPrim Plex Render: StoPrep In Concrete: StoPrim Plex Render: StoPrep In Level filling StoPox WS 50 StoLevell In Z StoLevell In Z StoLevell In Z Gypsum plasterboards: StoLevell In Fill Stipple filling StoPox WB 50 StoLevell In XXL StoLevell In Z StoLevell In Z All-over filling StoPox WB 50 StoLevell In XXL StoLevell In Z StoLevell In Z Grinding Prime coating StoPrim Plex StoPrim Plex Glass fleece StoTap Pro 100 P With StoTex Coll adhesive StoTap Pro 100 P With StoTex Coll adhesive Prime coating StoPox WL 100 StoPox WL 100 Sealing StoPox WL 100 in 2 layers StoPox WL 100 in 2 layers StoPox WL 100 in 2 layers StoPox WL 100 in 2 layers StoPox WL 100 in 2 layers System view 14 Wall and ceiling systems The detailed technical specifications and information on the products contained in the Technical Data Sheets and approvals must be observed.

coating systems for walls and ceilings Wall/ Ceiling System 1 Wall/ Ceiling System 2 Wall/ Ceiling System 3 Wall/ Ceiling System 4 Wall/ Ceiling System 5 Test certificates Decontaminability»very good«outgassing behaviour Particle formation Resistance to disinfectants Resistance to fungi and bacteria Suitability for indirect contact with food Wall and ceiling systems 15