STOREFRONT DESIGN CRITERIA. Section II STOREFRONT DESIGN CRITERIA 2-1



Similar documents
GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES

DESIGN GUIDELINES FOR COMMERCIAL, INDUSTRIAL AND MIXED-USE BUILDINGS

Certification: Building Plans Examiner. Exam ID: B3

Walmart 4th Wall. Advertising and Lease Line Guidelines. June Customerexperience

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

March 14, Installation of Bay, Bow and Garden Windows

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Materials and Colors

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Automatic Door Selection Guide

Asphalt Shingle Application Requirements

COMMUNITY APPEARANCE STANDARDS

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Assessing Curtain Walls

glass & Glazing Products

THIRD LAGUNA HILLS MUTUAL

TENANT ARCHITECTURAL DESIGN CRITERIA HANDBOOK #1

Tenant Criteria Manual Architectural

Residential Window Replacement Design Guidelines

A Complete Solution CREATING WALLS THAT DEFINE SPACE

SECTION STANDING SEAM METAL ROOFING

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

Page & Turnbull imagining change in historic environments through design, research, and technology

Quality Building Products for over 50 Years

CLEAR-DIVISIONS CENTERFOLD

Number of Sides Required to Have a Handrail

Sample Drawing Package for One and Two Family Dwelling Applications

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Tundra Series Windows January 2016

DESIGN REVIEW CHECKLIST Chapter 6 Special Consideration Design Guidelines

EAST LYME HIGH SCHOOL

17,280 square feet Overview:

City of San Diego, CWP Guidelines

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

Chapter 3 Pre-Installation, Foundations and Piers

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Sun Windows General Information Sun New Construction Window Installation Instructions

Vinyl Patio Door Systems

Comment Form on Proposed Gut Rehabilitation Alternatives

PART 1 GENERAL 1.1 SECTION INCLUDES

Architectural Design Standards Example Guide DESIGN STANDARDS EXAMPLE GUIDE

Architectural Control Guidelines

REQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $

Judy P. Rosenstreich, Senior Policy Advisor

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Important Information for Installer & Homeowner

CLEAR-DIVISIONS APERTO

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Window Installation Instructions

CLEAR-DIVISIONS VARIOFOLD

Texas Main Street. Design Services: Case Studies from Main Street Cities


Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

STRUCTURAL ASSESSMENT

PUBLIC RESTROOMS, DESIGN INTENT

Building Condition Assessment: North Howard Street Baltimore, Maryland

Building Condition Assessment: West Lexington Street Baltimore, Maryland

Garden Windows Builders Vinyl

City of Gardner S i g n a g e a n d Fa c a d e D e s i g n G u i d e l i n e s

Cost Comparisons for Common Commercial Wall Systems

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

Bungalow. Essential Elements. Prominent porch columns,

Slavic Village Building Condition Review

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

StuccoSpec Moisture Testing Inspection

Walking and Working Surface Checklist:

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

POST AND FRAME STRUCTURES (Pole Barns)

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Residential Decks. Planning and Development Services Department

Open Up Your Space, Add Light Series 2050 and Series 2050i Garden Windows

The replacement or modification of existing windows shall comply with the following requirements:

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No December 2014

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Elevating Your House. Introduction CHAPTER 5

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

INSTALLATION OF A BAY WINDOW

Enhancing The Beauty And Value Of Your Home. Exclusive Patio Door Collection. NORTH STAR PATIO DOOR COLLECTION Two-Panel Three-Panel Four-Panel

application instructions

HEDDERMAN ENGINEERING, INC. Office , Fax

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS WINDOWS

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Cascade Remodeling Inc. PO Box Portland, OR Catalyzing Euphoria Phone (503) , FAX (503) CCB # 67007

Structural Assessment Report

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Spandrel Glass Types and Recommendations

Guidelines for Windows and Doors

Mobile Home Pre-Inspection Checklist

2. Division 05 Structural Steel Framing for steel framework requirements

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Evanston Main Street Station TOD Plan and Study. Appendix A.1: Station Area Existing Conditions

Sample Calculations...V-CR-12. Door and Window Typical Combinations... V-CR-12 Horizontal and Vertical Typical Combinations...

Transcription:

STOREFRONT DESIGN CRITERIA Section II STOREFRONT DESIGN CRITERIA 2-1

Philosophy and Storefront Design Concept The Shoppes at Grand Prairie will be the premier lifestyle specialty shopping center in the Peoria metro area. The unique characteristics and quality tenant mix of this center calls for innovative and exciting storefronts. Critical to the design integrity and success of the overall shopping center are the individual contributions made by each Tenant s store. Therefore, it is essential that proper focus be given to proportion, scale, color, and detail construction when designing the Tenant storefront. These criteria are basic parameters that are meant to ensure a high level of design and construction quality, to encourage freedom of individual expression, and to provide a common point of departure for all Tenants. Storefronts should emphasize entry, the dramatic display of merchandise, and the Tenant identity. National or regional Tenants who have a typical or recognizable storefront design are expected to review these design criteria and adjust their design to ensure compatibility and compliance. All Tenants shall work closely with the Landlord Representative to achieve the same level of quality as the overall shopping center. Tenant Storefront Openings The Landlord shall provide openings in the exterior wall of the base building for Tenant s future storefront. All such openings shall be in accordance with the Landlord s Lease Outline Drawings (LOD) and specifications. The Tenant is responsible for the installation of a high quality exterior weather-tight storefront, including entry doors, within the exterior wall openings. See SPD Nos. 2A, 2B, and 3 for more information. Tenant Storefront Requirements The Tenant shall provide storefront infill construction within the base building exterior wall openings that shall comply with the following: All storefronts shall be composed of exterior weather-tight storefront components. If aluminum or other prefabricated storefront components are used, they shall be high quality commercial grade components installed and weatherproofed in accordance with all manufacturers recommendations. In the case of aluminum storefront systems, anodized finishes or other factory applied finishes are required. The storefront framing shall be a color that is compatible with the base building materials, and also reflective of the Tenant s desired design presentation. Un-finished mill aluminum, or field-finished framing members are not allowed. In addition, butt glazing glass panels shall not be allowed. Storefront finish materials including stone, brick, exterior rated ceramic tile, GFRC (panels or design elements), EIFS, stucco, or other high quality finish materials that are commercial grade and rated for exterior applications are encouraged. All such materials must be installed on appropriate substrate surfaces in accordance with all manufacturer recommendations. The Landlord may request specific product or test data be submitted to verify materials comply with minimum long-term durability standards. Prohibited finish storefront materials include the following: 3-2

painted finish plywood, moisture resistant gypsum board or other similar basic sheathing products Thin gauge metal metal laminates mirror finishes simulated natural materials such as faux wood or faux stone type products. All necessary insulation, flashing, sealing and other waterproofing measures at the storefront shall be the responsibility of the Tenant. Store Facade Transparency All storefront glazing shall be insulated type and clear. It must be safety glazed or tempered and compliant with all applicable codes. All exposed edges shall be ground and polished. Tenants shall maximize the use of glass to maintain a show window type concept. Opaque wall areas that exceed twenty percent of the individual opening width, up to a maximum of four feet (4-0 ) within the storefront openings, shall not be allowed. The show windows shall extend the full height of the opening except at signage conditions or other special design features that Tenant may propose, and Landlord may consider at Landlord s sole discretion. Display windows should be unique and individual. Window displays should thus be integrated into the architectural design and character of the entire storefront. A variety of innovative lighting and window designs should be explored. Display windows shall be transparent and open to the store. Due to the fact that the Tenant storefront is to be exterior grade, mullions and/or glazing channels will be required at all Tenant glazing. Although, the Landlord recommends a minimum use of mullions and/or frames in order to achieve a greater storefront transparency. Glazing clips are strictly prohibited. Typically, corner tenants must install display windows and/or store openings on both elevations. Store Facade Planning The storefront construction shall not project beyond the Storefront Control Line, except for approved projecting elements such as signage, awnings and canopies (See SPD Nos. 2A, 2B, 4, & 5 for more information). The Tenant façade shall fully infill the exterior, designated tenant wall opening extending from pier to pier at each side, and from the floor slab to the bottom of the Landlord bulkhead above. See the Landlord provided LOD for the designated tenant opening(s) that are particular to each Tenant space. Storefront Base 2-3

Tenants shall install a minimum 1-0 high-weatherproofed storefront base. The base must be a highly durable material such as metal, stone, masonry or other material that can withstand the exterior environmental conditions as well as standard exterior cleaning and snow removal equipment. All bases should complement the Tenant s storefront material. The Tenant s base shall be installed in coordination with the concrete slab edge location to insure an appropriate weatherproofed seal. The concrete slab edge is not allowed to be visible. See SPD 2A for details. Any other durable base material may be used, but it is first subject to Landlord review and approval. The base must be easy to maintain and it must match or be compatible with the Tenant s other storefront finishes. The storefront base should reflect the dimensional quality of the storefront. Storefront Entry Opening Width For stores which have a storefront facade width of less than 30-0, the total combined width of the storefront entry doors shall not exceed 6-0. For stores which have a storefront facade width of more than 30-0, the total combined width of the storefront entry doors shall not exceed 12-0. For stores with more than one facade elevation, one entry will be allowed for each distinct store facade elevation. The general opening width restrictions noted above shall apply for each individual elevation. Neutral Pier The neutral piers generally separate adjacent lease spaces and are provided and maintained by the Landlord. The Tenant is not responsible for the neutral piers and cannot modify, damage or attach to their finishes in any way. Refer to SPD Nos. 3, 4, and 5 for more information regarding the configuration and construction of typical neutral piers. Note that the caulking of the Tenant storefront to the Landlord neutral pier and/or bulkhead shall be by the Tenant at the Tenant s expense. See the SPD s listed above and the General Contractor s Guidelines publication for caulk specification. Mall or Landlord s Bulkhead The exterior Landlord bulkhead above the storefront is a standard mall finish EIFS, provided and maintained by the Landlord on the outside of the lease premises. The Tenant cannot change or modify the bulkhead, nor is the Tenant responsible for its maintenance, except for patching and repairing the bulkhead to a like-new condition as a result of any damage caused by the Tenant during sign installation and/or construction. Storefront construction may brace to the bulkhead but may not be structurally dependent on such attachment. All storefronts shall be selfsupporting and attached to the Landlord structure for lateral support only. Refer to Standard Project Detail Nos. 2A & 2B for more information. Storefront Awnings & Canopies 2-4

Decorative awnings and canopies that project beyond the plane of the store façade are an integral part of the architectural design intent at The Shoppes at Grand Prairie. They provide cover from the elements as shoppers move about the courtyard area and add dimensional interest to the character of the store façade. They are a required storefront element at Sign Criteria Zone #1. See the plan exhibit at Page 6-6 and SPD-2A for clarification. Tenants utilizing awnings and/or canopies are responsible for their supply and installation directly in front of their lease premises as per these criteria. Fabric, metal and glass awnings and canopies are permitted. The Tenant shall determine the awning/canopy style and color, but these elements are subject to the Landlord s review and approval. Awnings and canopies shall not be attached to the base building bulkhead or neutral piers. They shall only be attached to the Tenant storefront construction. Tenant awnings and canopies and their associated framing systems shall be appropriately designed to resist deterioration due to weathering, to withstand applicable wind and snow loads, to prevent bird-nesting, and shall be in compliance with all other storefront criteria. Silk-screen awning signage is encouraged. Vinyl adhesive decal lettering and or logos will not be permitted. All storefront awnings and canopies shall be designed and constructed with the highest quality standards. For example, the underside of a canopy or awning shall be fully finished unfinished framing components, fasteners and other elements will not be allowed. Projections Over the Storefront Control Line Store facade projecting elements shall comply with the following: Minimum height to bottom of projecting element: 9-0 Horizontal projection requirements: Maximum Projection: 5-0 Minimum Projection: 3-0 Horizontal projection requirements are measured from the Lease Line. Accessory down lighting may be required beneath projecting elements that extend out greater than 3-0 to provide adequate illumination of the pedestrian walking surface. Projecting elements shall be designed and located so that they do not create a significant visual barrier to adjacent tenant store facades. Landlord shall have final determination regarding clearance and sight line issues. All projecting elements shall be designed and constructed with the highest quality standards. 2-5

Exterior Surface-Mounted Lighting Tenant proposals for exterior surface-mounted lighting, including storefront accent lighting, at canopies, awnings, outdoor dining areas, and signage locations shall be submitted to the Landlord Representative with the Working Drawings submittal for review and approval. See Section Five of this manual, Store Lighting, for more information. Entry Door / Store Closure Requirements Entry doors are encouraged to be substantially glass, but the store closure type may be any one of the following: Pivoting aluminum/glass doors. Pivoting wood/glass doors. Revolving aluminum/glass doors Plain aluminum storefront framed doors with standard type handles and hardware are not allowed. Solid, fully opaque doors without glass lites are also prohibited. The storefront doors are required to incorporate decorative features that enhance the overall storefront appearance. Options include aluminum and glass doors with decorative handles, glass doors with muntin divided lites or other special door options. Tenant designers should strive to specify doors that become an integral aesthetic feature to the overall storefront. All door systems shall be weather tight as required for an open-air mall with all necessary hardware and accessories. Door components, such as locking mechanisms and other accoutrements, are to be recessed and hidden from view. All handles and locking mechanisms shall comply with ADA requirements. Thresholds shall comply with ADA requirements and shall provide an even transition from exterior to interior. If the use of an air lock or vestibule is preferred it shall be designed as part of the storefront and shall be located within the lease premises, behind the Storefront Control Line. Tenants must typically provide outward swinging doors at the store entry. All out-swinging entry doors shall be recessed a minimum of 3-0 behind the Storefront Control Line. See Storefront Recessed Entry Alcove Requirements below and SPD-20A for more information. 2-6

In-swinging doors will be allowed only if in compliance with code egress requirements. At in-swinging door conditions, the doors shall be recessed 1-6 behind the storefront control line to create a recessed entry area. The Recessed Entry Frost Footing detail, SPD-20A, is not required at in-swinging door configurations. Tenants with proposed entrance doors off side walkways or facing the parking lot shall review entry door location issues with the Landlord s Tenant Coordination staff. Storefront Recessed Entry Alcove Requirements Tenants with out-swing door type recessed entry areas shall saw-cut the perimeter of their proposed entry, remove the existing concrete floor slab, excavate the existing soil to a depth matching the base building footing, construct a concrete frost footing, and install either the Landlord common area courtyard finish concrete or a unique exterior-grade floor finish, compatible with the Tenant's overall storefront design and/or corporate image, to be reviewed and approved by the Landlord Representative on a case by case basis. The tenant s recessed entry zone flooring material shall extend from the Storefront Control Line to the line of door closure. See Standard Project Detail SPD-20A for details. The elevation of the finished floor within the Tenant area must correspond within ½ of the top of the adjacent exterior common area finishes and must additionally comply with all ADA requirements including, but not limited to any slope and slip resistance requirements, and be specifically detailed on the plans The ceiling at the exterior recessed entry area shall be a weatherproofed finished material such as metal panels, plaster, or EIFS. The Tenant shall provide exterior rated recessed lighting in the ceiling to accent the entry. Storefront Structure All storefronts shall be self-supporting transferring all gravity loads to the concrete slab. All accessory storefront elements such as awnings and canopies shall be supported off of the Tenant s storefront structure, with bracing back to the Landlord s base building structure as required. Transference of significant support loads for such elements to the base building exterior walls or structure will not be allowed. Any lateral or gravity loads imposed on the Landlord s structure may require detailed structural analysis by the Landlord s structural engineer, and completion of necessary reinforcement or bracing as required at Tenant s expense. Signage Signage shall be as outlined in Section Six, Tenant Sign Criteria, of this design criteria manual. 2-7