How To Add Drives To A Dip7080-00N Recording Appliance



Similar documents
Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer

How To Use A Raid

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Contents. Overview. Drive Policy RAID 500 features. Disable BGI RAID 700 features. Management Tasks Choosing the RAID Level.

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Guide to SATA Hard Disks Installation and RAID Configuration

Managing RAID. RAID Options

DLA Storage Appliance Deployment in NAS/DAS Environment

WebBIOS Configuration Utility Guide

Managing Storage Using RAID

MegaRAID SAS User Guide for Linux

MSM Software Feature Difference Between the MR Controller and the IR Controller

1200/1400 Series as standard iscsi disk array. Quick Installation Guide

Marvell SATA3 RAID Installation Guide

Guide to SATA Hard Disks Installation and RAID Configuration

User Guide - English. Embedded MegaRAID Software

Setting up SATA RAID on the HP xw4600, xw6600, and xw8600 Workstations

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

ION-NAS Network Storage Solutions

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00


NVIDIA RAID Installation Guide

RAID EzAssist Configuration Utility Quick Configuration Guide

MegaRAID SAS Device Driver Installation

Installing and Configuring SAS Hardware RAID on HP Workstations

User Manual for SAS RAID 2108

Guide to SATA Hard Disks Installation and RAID Configuration

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

Installing the Operating System or Hypervisor

4.4 Managing Software Licensing

This user guide describes features that are common to most models. Some features may not be available on your computer.

USER S GUIDE. MegaRAID Configuration Software. February 2003 Version 1.0 DB

The motherboard supports the following SATA RAID solutions:

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

LSI 2108/2208 SAS MegaRAID Configuration Utility

Agilent Modular Products Connecting and Configuring JMR RAID to Work with the Agilent M9392A Vector Signal Analyzer System

This chapter explains how to update device drivers and apply hotfix.

DF to-2 SATA II RAID Box

LSI Software RAID Configuration Utility

PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Configuring ThinkServer RAID 100 on the TS140 and TS440

AMD SP5100 Dot Hill SATA RAID Users Manual V100

AMD RAID Installation Guide

From Product Management Telephone Nuremberg. This letter contains latest information about the above mentioned Bosch DIVAR IP 3000 Family.

Manual OS Installation

Configuring ThinkServer RAID 100 on the Lenovo TS430

Remote PC Guide Series - Volume 2a

Computer Setup User Guide

McAfee Firewall Enterprise

USER S GUIDE. MegaRAID SAS Software. June 2007 Version , Rev. B

RAIDCore User Manual P/N Revision A December 2009

USER S GUIDE. MegaRAID SAS Software. April , Rev. D

Remote PC Guide Series - Volume 2b

Cisco FlexFlash: Use and Manage Cisco Flexible Flash Internal SD Card for Cisco UCS C-Series Standalone Rack Servers

LSI MegaRAID User s Manual

Guide to SATA Hard Disks Installation and RAID Configuration

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Configuring a SSD RAID-0 Array on an AMD System

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Updating Your Firmware

Secure Perfect RAID Recovery Instructions

Installation Guide July 2009

MegaRAID RAID Controller Configuration Software Guide

MegaRAID SAS Device Driver Installation

Guide to SATA Hard Disks Installation and RAID Configuration

Using ATI Array Management Software (WebPAM)

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

Intel Rapid Storage Technology

RAID installation guide

Embedded MegaRAID Software

Embedded MegaRAID Software

High-Availability User s Guide v2.00

MaxAttach NAS 4000 Series OS 2.2 Hard Disk Drive Replacement

VIA RAID Installation Guide

NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition -

Certification Document macle GmbH Grafenthal-S1212M 24/02/2015. macle GmbH Grafenthal-S1212M Storage system

Rebuilding a Show Store RAID with the original drives

How to Install Microsoft Windows Server 2008 R2 in VMware ESXi

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

Intel Matrix Storage Manager 8.x

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

4 Backing Up and Restoring System Software

PCI Express SATA / esata 6Gb/s RAID Card User Manual

Configuring ThinkServer RAID 100 on the Lenovo TS130

Acronis Backup & Recovery 11

SOS SO S O n O lin n e lin e Bac Ba kup cku ck p u USER MANUAL

Ultra Thin Client TC-401 TC-402. Users s Guide

Intel Matrix Storage Console

StarWind iscsi SAN: Configuring Global Deduplication May 2012

Intel RAID Controller Premium Feature Key Training

Xserve G5 Using the Hardware RAID PCI Card Instructions for using the software provided with the Hardware RAID PCI Card

Configuration Manual. Version November Production & Playout Server

Embedded MegaRAID Software

Intel RAID Software User s Guide:

RAID OPTION ROM USER MANUAL. Version 1.6

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

Transcription:

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 1 DIP-7080-00N Initial RAID Setup Technical Brief Purpose The purpose of this technical brief is to provide the step-by-step process of adding drives to a DIP-7080-00N Recording appliance. Prior to Starting: To better understand the setup procedure in this technical brief you must first understand the functional state which you must configure. The DIP7080-00N Recording Appliance is equipped with an 80GB SSD (Solid State Drive) which contains the device s operating system. The device contains a SATA DOM (Disk On Module) which contains restoration images of the devices in its factory defaulted condition. This version of the DIVAR IP Recording Appliance ships with no storage drives. Drives are supplied by the customer and must be configured as outlined in this technical brief. Equipment needed: Customer s Drives, PS/2 Mouse, and PS/2 KBD The DIP7080-00N Recording Appliance can perform RAID 5 via an internal LSI Controller Card. The LSI Controller when configured will present all drives in the device as a virtual drive. Virtual Drive 0 once configured will equal the entirety of all drives added. The available size of your RAID array will vary based on the number and size or hard disks added. To the right we see a functional DIP 7000 with four drives added to the unit. All drives are configured and assigned to VD0. (Functional 4 Drive Unit) The LSI Controller Card will write basic RAID-Configuration Information to any drive it configures. This is referred to COD (Configuration on Disk) and is only accessible by the controller card itself. The small cache area where the COD resides is not affected by normal read/write operations. Drives with a valid COD are green and marked as Online. Drives that are viewed as unrecognized or have no COD are blue and marked as Unconfigured. Lastly, RAID 5 devices can only sustain a one drive loss, if not configured with a hot spare. The following procedure is based upon adding all new drives to a DLA base unit with no hot spare configured.

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 2 Accessing LSI BIOS After receiving the DIP 7000 and physically installing replacement drives, boot your storage appliance. After the Bosch splash screen you will see the LSI boot process messages: Press Ctrl + h throughout the boot process to access the LSI BIOS interface. 1) Once you access the LSI BIOS Interface select the start button. 2) The main LSI WEBBIOS page should load. From this page you should see all new replacement drives as Unconfigured. Select the Configuration Wizard menu option.

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 3 3) From the Configuration Wizard page ensure Ne w Configuration is selected and the select Next. 4) From the second page of the wizard ensure the following are selected: Manual Configuration Redundancy when possible Select Next.

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 4 5) From the third page of the wizard you will need to add all new drives to a Drive Group. Select all drives while holding the Ctrl key then select the Add To Array button. 6) After selecting Add To Array all drives should appear on the right side of the menu under Drive Group0. Select Accept DG 7) After accepting the disk group you should see Drive Group1 below Drive Group0. Select the next button

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 5 8) The Array With Free Space menu on the left should show Drive Group0 available. Select Add to Span. Drive Group0 should appear in the Span menu on the right Select Ne xt 9) From this menu page you will need to ensure the following settings: RAID Level: 5 Strip Size: 64 KB Access Policy: RW READ Policy: Ahead Write Policy: Alwa ys Write Back o This setting can impact performance! IO Policy: Cached Drive Cache: NoChange Disable BGI: No Select Size: Enter the amount shown for the R5 option. Shown here 2.725 TB Select Accept 10) After selecting Accept you will be asked Are you sure you want to select Always Write Back mode?. Select Yes

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 6 11) After selecting Yes you will be brought back to the Virtual Drive Definition menu page. The message will appear Press Back Button to Add Another Virtual Drive Select the Ne xt button 12) You should see VD 0 in the Virtual Drive Definition menu page select Accept.

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 7 13) You will now be presented with two options: Save this Configuration? o Select Yes All data on the Virtual Drives will be lost. Want to Initialize? o Select Yes 14) You should be in the last menu page of Virtual Drives. Select VD0 then select Fast Initialize Select GO After the screen refreshes select Home 15) The WebBIOS home page should appear and look similar to what is pictured below Select Exit You will be prompted to exit again, select Exit and reboot the appliance

CCTV Video Solutions Technical Brief DIP-7080-00N Initial RAID Setup 8 Preparing Your RAID ARRAY to receive video: Restore Image (SATA DOM) NOTE: Th e n ext step will prep your array with VHDs that act as iscsi Targets. At this point you have unpartitioned and unfo rmatted drives. This document covers DIP 7000 Appliance equipped with a SATA DOM. 1) After reboot you will need to press and hold F11. If prompted to select between a SSD and SATA boot option select SATA. A Windows shell should load as shown here. 2) Once Windows has loaded, you should be presented with a splash screen as seen to the right. Select : Initial to Factory Setup (all data will be deleted) 3) After the image process reboot the appliance: You may need to check the boot sequence of your drives in the BIOS: The 80 GB SSD Drive should be you first Boot Option The Appliance will reboot several times as it sets up Windows for the first time On initial log on your credentials will be: o User: BVRAdmin o Password: WSS4Bosch If prompted to change your password enter WSS4Bosch