PC T8 PRO, 18 70 W T8 fluorescent lamps



Similar documents
Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Emergency lighting units EM powerled

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

Digital gear for fluorescent lamps

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

connecdim Gateway G1 Ethernet TCP/IP to DALI

LED control gear. LED control gear

IVIOS LED III. LUM Technical Information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Actuator-Sensor-Interface

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Drayton Digistat +2RF/+3RF

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

Product and functional description

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

T5 LongLast. GE Lighting DATA SHEET

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

SINEAX U553 Transducer for AC Voltage

COOL Shelf Quick Connect

is then retained absolutely without interruption.

ST Series POWER SUPPLIES USER INSTRUCTIONS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

User s Manual Before using the inverter, you need to read and save the safety instructions.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

The most sustainable lighting solution. QL 85W Induction Lighting System

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

T5 Watt-Miser Linear Fluorescent lamps

STRATO LED Drivers 70W, Single output

MOUNTING AND OPERATING INSTRUCTIONS

PHOENIX CONTACT Features

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Guide to Starters Guide to Starters Page 1 of 17

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

BB800 Off-Grid Solar System

ACS-30-EU-EMDR-10-MOD

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Safety technique. Emergency stop module BO 5988 safemaster

Rated Lumen [lm] Nominal. Volts [V] [lm]

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

Type: DILM9 10(24VDC) Article No.:

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

Mobile Data Power Model: MDP-25

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Linear Luminaire with LED Series EXLUX 6402/2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

650W Single Output Power Supply

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

DS 600. A contact free flux gate based current measurement sensor 600A rms

SYSTEM DESCRIPTION Termination Boards

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

ABB i-bus KNX SA/S Switch Actuators Product Manual

Features. High Brightness LED Light source

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

PWM-60 series IP67 TRC ELECTRONICS, INC

Type: DILM32 10(24V50HZ) Article No.:

Charge Controller CC611/CC612 Preliminary datasheet

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

QLT1500GB (120 ) QLT1500GH (60 ) 18W

Redundancy Module QUINT-DIODE/40

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

DLP-PU/E Instruction Manual

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

RM4TG20 three-phase network control relay RM4-T - range V

Three-phase monitoring relay CM-PFE

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

How To Build A Low Voltage Capacitor Lvcp

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Transcription:

T8 PC T8 PRO, 18 70 W T8 fluorescent lamps Product description Average life = 50,000 hours (at max ta. with a failure rate 0.2 % per 1,000 hours) Large temperature range (for values see table) Safety shutdown of defectvive lamps Automatic start after replacement of defective lamps For emergency lighting systems as per EN 50172 Constant luminous flux irrespective of fluctuations in mains voltage For luminaires of protection class 1 and protection class 2 For luminaires with F or M and MM as per EN 60598, VDE 0710 and VDE 0711 Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring Temperature protection as per EN 61347-2-3 C5e Technical data AC voltage range DC voltage range Overvoltage protection Defined warm start Operating frequency Type of protection 198 264 V 176 280 V ( start 198 V DC) 320 V AC, 1 h 1.5 s 40 khz IP20 È Standards, page 3 Wiring diagrams and installation examples, page 5 Ordering data Type Article number For luminaires with 1 lamp PC 1/18 T8 PRO 22176093 PC 1/30 T8 PRO 22176077 PC 1/36 T8 PRO 22176217 PC 1/58 T8 PRO 22176094 PC 1/70 T8 PRO 22176171 For luminaires with 2 lamps PC 2/18 T8 PRO 22176107 PC 2/30 T8 PRO 22176078 PC 2/36 T8 PRO 22176218 PC 2/58 T8 PRO 22176215 PC 2/70 T8 PRO 22176232 For luminaires with 3 lamps PC 3/18 T8 PRO 22176187 PC 3/36 T8 PRO 22176231 For luminaires with 4 lamps PC 4/18 T8 PRO 22176163 Packaging 234 mm casing: 10 pieces/carton, 630 pieces/pallet Packaging 360 mm casing: 10 pieces/carton, 420 pieces/pallet Packaging PC 1/36 T8 PRO, PC 2/36 T8 PRO, PC 2/58 T8 PRO: 10 pieces/carton, 640 pieces/pallet www.tridonic.com 1

Specific technical data wattage type Type Length L Hole spacing D Weight wattage Circuit power EEI Current at 50 Hz λ at 50 Hz point Ambient temperature ta 220 V 240 V 220 V 240 V For luminaires with 1 lamp 1 x 18 W T8 PC 1/18 T8 PRO 234 mm 220 mm 0.28 kg 16 W 18.2 W A2 0.08 A 0.08 A 0.99 0.98 70 C -25... 60 C 1 x 30 W T8 PC 1/30 T8 PRO 234 mm 220 mm 0.28 kg 24 W 28.0 W A2 0.13 A 0.12 A 0.97 0.96 75 C -25... 60 C 1 x 36 W T8 PC 1/36 T8 PRO 234 mm 220 mm 0.28 kg 32 W 35.0 W A2 0.16 A 0.15 A 0.98 0.98 75 C -25... 60 C 1 x 58 W T8 PC 1/58 T8 PRO 234 mm 220 mm 0.28 kg 50 W 54.0 W A2 0.26 A 0.24 A 0.98 0.98 75 C -25... 50 C 1 x 70 W T8 PC 1/70 T8 PRO 234 mm 220 mm 0.20 kg 60 W 65.6 W A2 0.30 A 0.28 A 0.99 0.98 75 C -25... 55 C For luminaires with 2 lamps 2 x 18 W T8 PC 2/18 T8 PRO 234 mm 220 mm 0.28 kg 32 W 36.0 W A2 0.17 A 0.16 A 0.98 0.97 75 C -25... 60 C 2 x 30 W T8 PC 2/30 T8 PRO 234 mm 220 mm 0.28 kg 50 W 56.0 W A2 0.26 A 0.24 A 0.97 0.96 75 C -25... 60 C 2 x 36 W T8 PC 2/36 T8 PRO 234 mm 220 mm 0.28 kg 64 W 69.8 W A2 0.32 A 0.29 A 0.99 0.98 75 C -25... 55 C 2 x 58 W T8 PC 2/58 T8 PRO 234 mm 220 mm 0.28 kg 100 W 106.8 W A2 0.49 A 0.45 A 0.99 0.99 80 C -25... 50 C 2 x 70 W T8 PC 2/70 T8 PRO 360 mm 350 mm 0.32 kg 120 W 136.8 W A2 0.62 A 0.57 A 0.99 0.99 70 C -25... 50 C For luminaires with 3 lamps 3 x 18 W T8 PC 3/18 T8 PRO 234 mm 220 mm 0.28 kg 48 W 52.5 W A2 0.24 A 0.23 A 0.98 0.97 70 C -25... 60 C 3 x 36 W T8 PC 3/36 T8 PRO 360 mm 350 mm 0.31 kg 96 W 106.5 W A2 0.51 A 0.47 A 0.99 0.98 70 C -25... 50 C For luminaires with 4 lamps 4 x 18 W T8 PC 4/18 T8 PRO 234 mm 220 mm 0.28 kg 64 W 70.1 W A2 0.33 A 0.30 A 0.98 0.97 70 C -25... 55 C www.tridonic.com 2

Standards EN 55015 EN 61347-2-4 EN 61347-2-3 EN 60929 EN 61000-3-2 EN 61547 in accordance with EN 50172 IEC 68-2-64 Fh IEC 68-2-29 Eb IEC 68-2-30 starting characteristics Warm start Starting time 1.5 sec. with AC and DC operation Cathode heating will be reduced after preheat time AC operation Mains voltage: 220 240 V 50/60 Hz 198 264 V 50/60 Hz including safety tolerance (±10 %) 202 254 V 50/60 Hz including performance tolerance (+6 % / -8 %) DC operation 220 240 V 0 Hz 198 280 V 0 Hz certain lamp start 176 280 V 0 Hz operating range Light output level in DC operation: 100 % Emergency lighting Use in emergency lighting installations according to EN 50172 or for emergency luminaires according to EN 61347-2-3 appendix J. Instant start after mains interruption < 0.5 s Intelligent Voltage Guard Intelligent Voltage Guard is the name of the new electronic monitor from Tridonic. This inno vative feature of the PC PRO family of control gear from Tridonic immediately shows if the mains voltage rises above or falls below certain thresholds. Measures can then be taken quickly to prevent damage to the control gear. If the mains voltage rises above approx. 306 V (voltage depends on the ballast type), the lamp starts flashing on and off. This signal demands disconnection of the power supply to the lighting system. If the mains voltage falls below 150 V the control gear automatically disconnects the lamp circuit to protect the control gear from being irreparably damaged. Smart Heating Innovative heating circuit. Reduced filament heating after lamp has struck. Mains currents in DC operation Mains current at Un = 220 VDC Mains current at Un = 240 VDC PC 1/18 T8 PRO T8 1x18 W 0.08 A 0.07 A PC 2/18 T8 PRO T8 2x18 W 0.17 A 0.15 A PC 3/18 T8 PRO T8 3x18 W 0.24 A 0.22 A PC 4/18 T8 PRO T8 4x18 W 0.32 A 0.29 A PC 1/30 T8 PRO T8 1x30 W 0.16 A 0.15 A PC 2/30 T8 PRO T8 2x30 W 0.27 A 0.25 A PC 1/36 T8 PRO T8 1x36 W 0.16 A 0.14 A PC 2/36 T8 PRO T8 2x36 W 0.31 A 0.29 A PC 3/36 T8 PRO T8 3x36 W 0.51 A 0.46 A PC 1/58 T8 PRO T8 1x58 W 0.26 A 0.24 A PC 2/58 T8 PRO T8 1x58 W 0.50 A 0.46 A PC 1/70 T8 PRO T8 1x70 W 0.30 A 0.28 A PC 2/70 T8 PRO T8 2x70 W 0.61 A 0.57 A Harmonic distortion in the mains supply THD at 230 V / 50 Hz PC 1/18 T8 PRO T8 1x18 W < 12 % PC 2/18 T8 PRO T8 2x18 W < 10 % PC 3/18 T8 PRO T8 3x18 W < 10 % PC 4/18 T8 PRO T8 4x18 W < 10 % PC 1/30 T8 PRO T8 1x30 W < 10 % PC 2/30 T8 PRO T8 2x30 W < 10 % PC 1/36 T8 PRO T8 1x36 W < 10 % PC 2/36 T8 PRO T8 2x36 W < 10 % PC 3/36 T8 PRO T8 3x36 W < 10 % PC 1/58 T8 PRO T8 1x58 W < 10 % PC 2/58 T8 PRO T8 1x58 W < 10 % PC 1/70 T8 PRO T8 1x70 W < 10 % PC 2/70 T8 PRO T8 2x70 W < 10 % Working voltage Uout PC 1/18 T8 PRO T8 1x18 W 300 V PC 2/18 T8 PRO T8 2x18 W 300 V PC 3/18 T8 PRO T8 3x18 W 250 V PC 4/18 T8 PRO T8 4x18 W 300 V PC 1/30 T8 PRO T8 1x30 W 250 V PC 2/30 T8 PRO T8 2x30 W 250 V PC 1/36 T8 PRO T8 1x36 W 300 V PC 2/36 T8 PRO T8 2x36 W 300 V PC 3/36 T8 PRO T8 3x36 W 250 V PC 1/58 T8 PRO T8 1x58 W 300 V PC 2/58 T8 PRO T8 1x58 W 300 V PC 1/70 T8 PRO T8 1x70 W 250 V PC 2/70 T8 PRO T8 2x70 W 250 V Ballast lumen factor (EN 60929 8.1) AC/DC-BLF bei U = 198 254 V, 25 C PC 1/18 T8 PRO T8 1x18 W 1.00 PC 2/18 T8 PRO T8 2x18 W 1.00 PC 3/18 T8 PRO T8 3x18 W 1.00 PC 4/18 T8 PRO T8 4x18 W 1.00 PC 1/30 T8 PRO T8 1x30 W 1.00 PC 2/30 T8 PRO T8 2x30 W 1.00 PC 1/36 T8 PRO T8 1x36 W 1.00 PC 2/36 T8 PRO T8 2x36 W 1.00 PC 3/36 T8 PRO T8 3x36 W 1.05 PC 1/58 T8 PRO T8 1x58 W 1.00 PC 2/58 T8 PRO T8 1x58 W 1.00 PC 1/70 T8 PRO T8 1x70 W 1.00 PC 2/70 T8 PRO T8 2x70 W 1.00 www.tridonic.com 3

PC PRO with xitec processor Is the very latest in lighting management design technology. The lamp friendly warm start is delivering maximum T8 lamp life and enables high swihing frequency applications. Smallest power loss and new freedom in the lamp design thanks to convincing thermal management. Energy class CELMA PC T8 PRO ignition technology (smart heating) optimises lamp start and ensures no energy is wasted. After the lamp has struck the filament heating is reduced automatically to a defined minimum value. This reduction in filament heating, saves energy, yet maintains the proper operating conditions for the lamp. The lamp is always operated within specification. PC 1/xx T8 PRO, PC 2/xx T8 PRO 15 mm 19 mm 143 mm 174 mm PC 3/36 T8 PRO, PC 2/70 T8 PRO 228 mm 260 mm Ambient Temperature -25 C to +50 C resp. 55 C resp. 60 C PC 3/18 T8 PRO, PC 4/18 T8 PRO 20 mm 15 mm 144 mm 175 mm PC 1/30 T8 PRO, PC 2/30 T8 PRO 140 mm 170 mm The nominal ta and point are related to the ballast life duration. The relation of to ta temperature depends also on the luminaire design. If the measured temperature is approx. 5 K below max., ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request. PC T8 PRO is designed for an average service life of 50,000 hours under reference conditions and with a failure probability of less than 10 %. This corresponds to an average failure rate of 0.2 % for every 1,000 hours of operation. Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. Maximum loading of automatic circuit breakers Automatic circuit C10 C13 C16 C20 B10 B13 B16 B20 Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 PC 1/18 T8 PRO 44 62 74 104 22 31 37 52 PC 2/18 T8 PRO 36 50 60 72 18 25 30 36 PC 3/18 T8 PRO 40 60 80 92 20 30 40 46 PC 4/18 T8 PRO 30 40 52 64 15 20 26 32 PC 1/30 T8 PRO 40 52 60 72 19 26 30 36 PC 2/30 T8 PRO 22 30 38 42 11 15 19 21 PC 1/36 T8 PRO 38 52 60 72 19 26 30 36 PC 2/36 T8 PRO 24 32 38 44 12 16 19 22 PC 3/36 T8 PRO 18 24 32 40 9 12 16 20 PC 1/58 T8 PRO 36 50 60 70 18 25 30 35 PC 2/58 T8 PRO 16 22 26 30 8 11 13 15 PC 1/70 T8 PRO 20 26 34 42 10 13 17 21 PC 2/70 T8 PRO 10 14 18 20 5 7 9 10 Wiring advice The lead length is dependant on the capacitance of the cable. For safety reasons, the PC T8 PRO must only be earthed in the case of a safety class 1 luminaire. Earthing is not required for the device to operate. Connection to earth reduces radio interference. Ballast Terminal Maximum capacitance allowed Type Cold Hot Kalt Heiß PC 1xx T8 PRO 11, 12 9, 10 200 pf 100 pf PC 2xx T8 PRO 11, 12, 13, 14 9, 10 200 pf 100 pf PC 3xx T8 PRO 11, 12, 13, 14, 15, 16 9, 10 200 pf 100 pf PC 4xx T8 PRO 5, 6, 11, 12, 13, 14, 15, 16 9, 10 200 pf 100 pf With standard solid wire 0.5/0.75 mm 2 the capacitance of the lead is approx. 80 pf/m. This value is influenced by the way the wiring is made. In borderline cases the capacitance must be measured inside the luminaire. Keep lamp wires short. connection with twin ballast should be made with symmetrical wiring. Hot leads and cold leads should be separated as much as possible. To avoid the damage of the control gear, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, e.) www.tridonic.com 4

Installation instructions IDC interface solid wire with a cross section of 0.5 mm² according to the specification from WAGO Horizontal interface solid wire with a cross section of 0.5 1.5 mm² according to the specification from WAGO strip 7.5 8.5 mm of insulation from the cables to ensure perfect operation of the push terminals wire preparation: 0.5 1.5 mm² 7.5 8.5 mm Defective lamp If a lamp is defective, the ballast swihes off and goes into standby. There is an automatic restart once the lamp has been changed. Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. RFI Tridonic ballasts are RFI protected in accordance with EN 55015:2006 and A1:2007. To operate the luminaire correctly and and to minimise RFI we recommend the following instructions: Connection to the lamps of the hot leads must be kept as short as possible (marked with *) Mains leads should be kept apart from lamp leads (ideally 5 10 cm distance) Do not run mains leads adjacent to the electronic ballast Twist the lamp leads Keep the distance of lamp leads from the metal work as large as possible Connect functional earth, either over the terminal or over the mounting screw of the ballast Mains wiring to be twisted when through wiring Keep the mains leads inside the luminaire as short as possible Additional information Additional technical information at www.tridonic.com Technical Data Loosen wire T8 lamp information Guarantee conditions at www.tridonic.com Services No warranty if device was opened. wattage length 18 W 590 mm 30 W 900 mm 36 W 1200 mm 58 W 1500 mm 70 W 1800 mm 3 4 3 4 12 11 10 9 14 13 12 11 10 9 leads 11, 12 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth of ballast housing required (according to IEC 598) PC 1x18 70 W T8 PRO leads 11, 12, 13, 14 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth of ballast housing required (according to IEC 598) PC 2x18 70 W T8 PRO leads 11, 12, 13, 14, 15, 16 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth via fixing of ballast housing (according to IEC 60598) leads 5, 6, 11, 12, 13, 14, 15, 16 max. 2.0 m (< 200 pf) Protection class I - luminaires: earth via fixing of ballast housing (according to IEC 60598) PC 3x18 36 W T8 PRO PC 4x18 W T8 PRO www.tridonic.com 5