Development of backup power systems at Wuhan Troowin Power System



Similar documents
MPR-Systems. Mini Power Racks 1200 W W

Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks

Fuel cells for long distance emobility: Content

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

HBOX SOLAR 3A SOLAR POWERED ELECTROLYSER CASE STUDY 03

Fuel Cells for Renewable Energy and for Transportation IFCBC Meeting Prof. E. Peled School of Chemistry Tel Aviv University, Israel

Datasheet. Observe safety instructions on page 3 V2.1

Testing the voltage and power as function of current density. Polarisation curve for a SOFC single cell

Wasserstoff und Brennstoffzellen. E.V.A. / bmvit Workshop Wien, Stand Alone Photovoltaic Fuel Cell Hybrid Systems

Energy efficiency and fuel consumption of fuel cells powered test railway vehicle

Phase Modular Finally the benefits of Modular ups are for all

HyPM Fuel Cell Power Modules

Fuel Cell solutions for maritime and harbour applications Proton Motor Fuel Cell GmbH. Sebastian Dirk Venice, 14th of June

Fuel Cell Systems for Telecom Backup Power

Online UPS. PowerWalker VFI 1000R/1U

INTA Renewable Energy Area activities

ATTACHMENT B California Energy Commission Air Quality Self-Certification Checklist for Simple-Cycle Gas Turbine Generation Units

Ultracapacitors Help P21 To Provide Fuel Cell Based Backup Power For Telecoms

Fuel Cell Characterization Lab

Half the cost Half the carbon

Operating Manual UWAPS-TINY Series

U.S. Department of Energy-Funded Performance Validation of Fuel Cell Material Handling Equipment

New Energy Lab. Experiment Guide. New Energy Lab - Experiment Guide 1

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Thyristor-controlled power supplies and battery chargers

hybrid fuel cell bus

NoteBox NoteBox with room for 16 tablets

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Maritime Fuel Cells - durability and performance aspects Anders Ødegård, SINTEF

Height w/o Terminals (in)

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

UMEC International Corporation

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Solid Oxide Fuel Cell Development at Topsoe Fuel Cell A/S

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

SERVIZIO NEWS SPOTTER. e MOBILE TOOWAY 2. per informazioni numero verde

Hydrogen Powered Bus Fleets Hydrogen Supply & Fueling. National Fuel Cell Bus Workshop October 5, New Orleans, LA

How To Make A Fronius Cl Power Inverter

Technical specifications. Containerized data centre NTR CDC 40f+

The UPS for the highest security in industry and data centres

Height w/o Terminals (in)

High Power Programmable DC Power Supplies PVS Series

CP Page 1342 Mar 2008 Siemens ITS

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Carefree Sealed Lead Acid (SLA) MSDS

The CP provides access to different communication services of the PROFIBUS bus system:

SOFC Single Cell Performance and Endurance Test Modules

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Week Date Description Lecturer Jan HEV and EV (+Assignment announcement ) Norbert Cheung Jan HEV and EV Design options Norbert Cheung

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH

Li-ion Rechargeable Battery. Specification

RiMatrix S Make easy.

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

LED-INTA-0024V-41-F-O

PHOENIX CONTACT Features

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

The CP FO provides access to different communication services of the PROFIBUS bus system:

Heating Controller. Building Technologies HVAC Products

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Vincenzo Esposito. Università di Roma Tor Vergata

I STAR COMPUTER CO., LTD

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

CA723, CA723C. Voltage Regulators Adjustable from 2V to 37V at Output Currents Up to 150mA without External Pass Transistors. Features.

DOCUMENTATION PD16 CP3-SVE-M75DC-24

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

TYPICAL APPLICATION CIRCUIT. ORDER INFORMATION SOP-EP 8 pin A703EFT (Lead Free) A703EGT (Green)

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

5 kw Alkaline fuel cells target commercialization

CRAC Precision climate control units for data centres

NGSS Data Consolidator (DC)

General Specifications

CHIC: Clean Hydrogen In European Cities - demonstration of 52 FC hydrogen buses - Hannover MESSE, Dr. Philipp Krüger, hysolutions

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

The Elwing Company THE ELWING COMPANY. EPIC Workshop Products and Systems

Cooling kw Heating kw

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

Keywords: polymer electrolyte membrane fuel cells; stack failure; gasket; indicators

ECOCIAT. Domestic hot water heat recovery unit

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

70 Mpa Hydrogen Refuelling Stations

Application Note TMA Series

Model: DC-A2IO Advanced HVAC Controller

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

Transcription:

Development of backup power systems at Wuhan Troowin Power System Zhigang Qi Workshop on Fuel Cell Backup Power for Telecommunication Base Stations Wuhan University of Technology, Wuhan, China, May 29, 2015

Contents WuhanTroowinPower Air-cooledStacks BackupPowerSystems FieldTrials Challenges Summary 2

Wuhan Troowin Power System Establishedin2011withheadquarterslocatedin Wuhan FocusedontheR&DandmarketingofPEMFCand DMFCstacksandsystems Experiencedmanagementteamandworld-class technicalteam Establishedbroaddomesticandinternational collaborations Wellfinancedbyvisionaryinvestors 3

Technology Platform Liquid-cooled stacks Stationary power Large motive power Air-cooled stacks Backup power Small motive power DMFCs Portable power Small stationary power Hydrogen production Hydrogen station Special applications 4

Air-cooled Stacks Power(W)/ Length Width Height Weight MassPD Vol.PD Cell number (mm) (mm) (mm) (kg) (W/kg) (W/L) 50/5 121 51 55 0.65 77 147 100/5 205 51 55 1.10 91 174 300/30 121 51 140 1.21 248 347 1200/60 205 51 230 3.50 343 499 Cell Performance 1.2 Cell Voltage (V) 1 0.8 0.6 0.4 0.2 0 Ambient condition without humidification 0.72V@0.5A/cm 2 0.36W/cm 2 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Current Density(A/cm 2 ) 5

Air-cooled Stacks Cell Voltage Stdev/mV Average Cell Voltage/V 1.2 1.0 0.8 0.6 0.4 0.2 0.0 30 25 20 15 10 5 0 MEA-1_OCV MEA-2_OCV MEA-1_0.5A/cm2 MEA-2_0.5A/cm2 0 1000 2000 3000 4000 5000 Running Time/h MEA-1_OCV MEA-2_OCV MEA-1_0.5A/cm2 MEA-2_0.5A/cm2 0 1000 2000 3000 4000 5000 Running Time/h Operated24/7 automatically 97%H 2 utilization StackswithMEA1 14μV/hdecayrate in4500hat0.5 A/cm 2 OCVchangedlittle in4500h StackswithMEA2 28μV/hdecayrate in2800hat0.5 A/cm 2 OCValsoshowed apparentdecline Cellvoltagevariation behaveddifferently 6

Backup Power Systems Front View Back View 7

Backup Power Systems 8

Backup Power Systems 3kWsystemcontains3stackmodules Eachmoduleworksindependently,andhotswappable Modulardesignmakesthesystemscalable 45%systemefficiency Weightednoisevoltage0.72mV( 2mV) Peak-peaknoisevoltage52mV( 200mV) Standbypowerconsumption1.1% Outputvoltagestability±0.4% Remotemessaging,measurementand control 9

Backup Power Systems Remotecommunications Computer companyserver internet GPRS remotemonitoringmodule FCsystem Remotemeasurement Stackoutputvoltageandcurrent FCsystemoutputvoltageandcurrent Stacktemperatureandenvironmenttemperature H 2 pressure Remotemessaging Stacktemperaturehigh,environmenttemperaturehigh FCoutputvoltagehigh/low,outputcurrenthigh H 2 pressurehigh/low,h 2 leakage Fannormal/abnormal Gridpoweron/off StationDCbussvoltagehigh/low Remotecontrol Startup/shutdownFCsystem Messagetocell-phone FCsystemstate Problemcodes 10

Field Trials StartedonFeb.7,2015inSichuanprovince,experienced7-30 o C FCoutputconnectedtotheDCbussofthestation A100ADCcontactoraddedbetweenthestation sbatteryandthe station sdcbuss 6H 2 cylindersintwogroups FC H 2 11

Field Trials Date Startup Type Weather T ( o C) Startup time Shutdown time Duration (min) 2015/3/6 Poweroff Cloudy 13 8:25 11:27 182 2015/3/6 Remote Cloudy 13 16:30 16:35 5 2015/3/9 Remote Cloudy 18 16:36 16:47 11 2015/3/16 Poweroff Cloudy 16 9:59 10:09 10 2015/3/20 Remote Raining 16 11:15 11:21 6 2015/3/24 Poweroff Raining 17 9:35 10:13 38 2015/4/14 Poweroff Raining 21 10:23 11:00 37 2015/4/19 Poweroff Raining 22 03:00 04:03 63 2015/5/4 Poweroff Raining 15 18:07 18:29 22 2015/5/22 Poweroff Raining 19 01:10 17:10 960 CumulatedRunningTime 1334 12

Field Trials 60 2500 50 2000 Voltage/Current (V/A) 40 30 20 D_OutputV D_OutputI D_Power 1500 1000 500 Power (W) 10 FC output voltage set at 54.5 V 0 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Time (s) 500 13

Challenges Majorobstacles Misconceptions Usedtotraditionaltechnologies Lackofurgencyandresponsibility Higherinitialinvestment Shortvision Lackofhydrogeninfrastructure Whatshouldbedone Collaborativeeffortsbygovernments, companies,andthepublic Governmentreinforcement Governmentsubsidies 14

Summary TroowinPower sair-cooledstackshavehigherpower densitiesthanmanypeer sstacks Runningfor4500hhasbeenachievedinlab Backuppowersystemsadoptmodulardesigncomposed ofindependenthot-swappablestackmodules Onesystemperformswellinfieldtrials Systemoptimizationcontinues Marketingfuelcellbackuppowersystemsfacesbig challengesinchina,governmentsinvolvementiscrucial 15