How To Use The Tsa 082N Video Switcher



Similar documents
DAB+ / FM Tuner Model: TU-201

Rack Mount LCD KVM Assembly Installer/User Guide

LOXONE 12 Channel Amplifier

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

15-INCH TFT-LCD MONITOR

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

COLOR VIDEO DOOR PHONE CDV-71BE/D

DCS Input/Output Relay Card Series

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

=============================== WARNING

User Instructions. Elation Professional R 4295 Charter Street Los Angeles CA

CX Zoner Installation & User Guide

OPERATION MANUAL. VDA-106A Video Distribution Amplifier. 1 st Edition - Rev.1

Microprocessor Home Security System

MCR1900 Media Converter 19-Slot Chassis

13" Real Time Quad Monitor with Camera System

Signal-400 HDMI COFDM (DVB-T) Encoder & Modulator. --- Home Use

User Manual Color video door phone

DVI DA2 and DVI DA 4 User Guide

How To Use A Sata Dsa Hard Disk Storage System

HP4000EX Hardware Manual

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

SCD Server. SCD Server Pro

HTT 101. HDMI/YPbPr/S-Video/AV to DVB-T. HDMI/YPbPr/S Encoder Modulator

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Achat 115MA full-range speaker. user manual

Advantium 2 Plus Alarm

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

focus TOuCh P10 FOR DISPLAYS: 55, 70 AND 82 ENgliSh V

GAE953 Electrical Alarm Unit 19" with Indicator

LCD Monitor User Manual

USER MANUAL. Kramer Electronics, Ltd. Models:

Antenna Splitter ASA 1. Instruction manual

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

HCS-3600MB2 Conference Main Unit

DDP-405 USER'S MANUAL

AM / FM Tuner + RDS. Model: TU

Features, Benefits, and Operation

Register your product and get support at. AS111. User manual

GSM Door Phone System

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

USER MANUAL. Kramer Electronics, Ltd. Models:

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Remote Sources. Facility. Router

( ) manual_tocomsat duo LITE.indd :44:57

TOA 900 SERIES II MIXER POWER AMPLIFIER

Colour Video Monitors PVM-9045QM/9042QM/9040ME PVM-6041QM

AutoRanging Digital MultiMeter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

16/32 Channel 1U Rack Mount CCTV Power Supply

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Physical Specifications (Custom design available.)

HP ProDisplay P17A LED Backlit Monitor. User Guide

Home Gateway. User s Installation Guide. In This Guide

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

VIDEO DOOR PHONE SYSTEM

CM6700 Matrix Switcher/Controller

I STAR COMPUTER CO., LTD

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

MIC-WKT and MIC-WKT-IR

Operation Manual for Users

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

17/19-INCH VALUE TFT-LCD MONITOR

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

VFS24/32HDIP. Public Display IP Monitor User Manual

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

IRT Eurocard. Types DAX-3200

IP Box Camera ACM Ver Hardware User s Manual

Contents. Safety Warnings... 1

HM-W536 Install Guide

HP ProDisplay P19A LED Backlit Monitor. User Guide

User s Manual Before using the inverter, you need to read and save the safety instructions.

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

ADM1TE 5/30A DIN rail single phase two wire energy meter

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

GSM HOME SECURITY SYSTEM

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

Manual Ranging MultiMeter

MOBILE CALL GSM Alarm System User s Manual

VT-DVR04. User s Manual. Version CHANNEL DIGITAL VIDEO RECORDER

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

BeoLab 7-1 BeoLab 7-2. Guide

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

4.3-inch Back-Up Camera

Digital Keypad Use s Manual

DC Electronic Loads 8500 series

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

User s Manual AURORA 1.2K/2.2K

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Single Channel Loop Detector

Video Cassette Player

Transcription:

TSA 082N VIDEO ALARM SEQUENTIAL SWITCHER Operating Instructions

CONTENTS Safety precautions... 2 Preface... 3 Features... 3 Precautions... 3 Controls and connectors... 4 Connections... 5 Alarm / Remote control connection... 7 VCR CLOCK connection... 7 Vertical interval switching... 7 Alarm specification... 7 Remote control... 7 On-screen display... 7 Set-up... 8 Standard setting... 11 Self test... 11 Installation... 11 Appearance... 12 Specifications... 12 Optional accessory... 13 SAFETY PRECAUTIONS In order to prevent any fatal accidents caused by misoperation or mishandling of the video switcher, be fully aware of all the following precautions. WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. WARNING: THIS APPARATUS MUST BE EARTHED WARNING: To prevent fire or shock hazard, do not expose this appliance to rain or moisture. This unit is produced to comply with Directives 93/68/EEC (IEC Publ.65) and 89/336/EEC. 2

PREFACE PRECAUTIONS The TSA 082N is a high quality microprocessor based video switcher which is suitable to connect up to eight cameras or other video sources. Two independent outputs allow to connect the main monitor and the video tape recorder with optional clock output. Alarm input is suitable to connect eight alarm sensors. Onscreen display function allows higher operational efficiency. Standard BNC-type input and output connectors enables the TSA 082N to be used with other CCTV switchers, cameras, monitors and video tape recorders. FEATURES Microprocessor based 8 video inputs 2 video outputs 8 alarm inputs Alarm output VCR-CLOCK input Frame-by-frame switching Vertical interval switching Built-in buzzer Nonvolatile RAM backup Remote control possibility On-screen camera/alarm identification Multi-language on-screen SET-UP Rack mountable using optional rack mount kit Use only the power source specified on the rating label located on rear of the cabinet. When not using this unit for a long period of time, or when cleaning it, be sure to disconnect the power plug from the AC outlet. Do not drop metallic parts through slots. This action could permanently damage this unit. Do turn power off immediately and refer servicing to qualified service personnel. Avoid using this unit under the following conditions: -in extremely hot, cold or humid places, -in dusty places, -near appliances generating strong magnetic fields, -in places subject to direct sunlight, and -in badly ventilated places. Unplug this unit from the AC outlet and refer servicing to qualified service personnel under the following conditions: -when the power cord is frayed or plug is damaged -if the unit does not operate normally following the operating instructions -if the unit has been dropped or the cabinet has been damaged -when the unit exhibits a distinct change in performance. 3

CONTROLS AND CONNECTORS FRONT PANEL 1 2 3 4 5 (1) CH B - TIME LED display to show the sequence of the CHANNEL B or the sequential time of the CHANNEL A. When the VCR CLOCK is selected the display shows C. When the frame-by-frame mode is selected the display shows F. When one of the TIME keys is pressed a decimal point lights and the display shows the selected sequential time - 0 for 1 to 9 seconds, 1 for 10 to 19 seconds etc. When an alarm occurs and the CHANNEL B is selected the decimal point blinks. (5) POWER Switch to turn the power on / off - lights in the power on position. (2) MODE - ALARM STOP Key to select operating mode - auto (sequential) or manual - or to reset the alarm. (3) TIME Keys to adjust the sequential time from 1 to 90 seconds. (4) CHANNEL A Keys to select the input signals in manual mode or to eliminate the inputs in auto (sequential) mode. In manual mode red LED lights at selected input, in auto (sequential) mode red+green LED lights at selected input. If all the inputs are eliminated, the switcher automatically switches the first input. 4

REAR PANEL 1 2 3 4 FUSE MODEL No. TSA 082N 8 7 6 5 (1) FUSE T 315 ma Fuse socket. (2) CH A BNC video output connector of the CHANNEL A. It is suitable to connect the main monitor. Onscreen display shows the number of selected input and sequential time adjusting. (3) CH B BNC video output connector of the CHANNEL B. It is suitable to connect the video tape recorder optionally with CLOCK output. (6) ALM Alarm output connector (terminal block), open collector output. It is suitable to connect the video tape recorder with alarm input. (7) VIDEO IN BNC video input connectors. They allow to connect up to eight video cameras or other video sources. (8) AC IN Power cord. (4) ALARM IN Alarm input / remote control connector (D-9F). It allows to connect up to eight alarm sensors. When the remote control possibility is used all the alarm inputs are inactive. (5) CLK VCR-CLOCK input connector (terminal block). When the video tape recorder with CLOCK output is used and connected to the VCR-CLK input, the sequence of the CHANNEL B will depend on the CLOCK pulse. In the SET-UP, VCR-CLOCK input has to be selected. 5

CONNECTIONS Be sure to disconnect the power plug from the AC outlet before connecting to other equipment. Also refer to the instruction manual of the equipment to be connected. CAM 4 CAM 8 CAM 2 CAM 6 VCR FUSE MODEL No. TSA 082N AC MAINS CAM 1 CAM 3 CAM 5 CAM 7 ALARM SENSORS or REMOTE KEYBOARD MON 6

ALARM / REMOTE CONTROL CONNECTION Connection diagram: Notes: Negative triggering - all alarm switches must be opened, in case of alarm they are closed. Positive triggering - all alarm switches must be closed, in case of alarm they are opened. Notes: T1 - start/stop key T2 - manual scan key VCR-CLOCK CONNECTION The VCR-CLK input is a standard TTL negative triggered input (5V to 0V) Note: If the VCR CLOCK pulse is 12V, set the jumper J2 to 12V position. VERTICAL INTERVAL SWITCHING This unit includes an electronic circuit which allows smooth switchings without picture roll or flutter. When the cameras and this unit are linelocked this function appears. Line-lock phase is adjustable in ±127 steps. (±2.2 ms) ALARM SPECIFICATION When only one alarm input is activated, the alarmed video input appears on the CHANNEL A or CHANNEL B. On the CHANNEL A the "ALARM" message is on the screen. Buzzer is activated. On the CHANNEL A auto and manual LEDs blink. When the CHANNEL B is selected the decimal point on the LED display blinks. Alarm output is activated (switched to the ground). When more then one alarm input is activated, the alarmed video inputs appear on the CHANNEL A or CHANNEL B sequentially. The CHANNEL B is automatically switched from sequential mode to frame-by-frame mode when the ALARM FRAME SWITCHING is enabled. This function is disabled when the VCR CLOCK is selected. Alarm sequential time and alarm duration time are adjusted in the SET-UP. With pressing the key ALARM STOP manual reset of alarm is achieved on the CHANNEL A. REMOTE CONTROL Remote control possibility on the CHANNEL A appears when the auto (sequential) mode is selected. Key T1 is used to stop and start the auto sequence. When it is stopped key T2 is used for manual scan. In the set-up, REMOTE CONTROL has to be selected. ON-SCREEN DISPLAY For enhanced operational efficiency, the TSA 082N has an multi-language on-screen display function on the CHANNEL A in English, Italian and German language. The characters are displayed as white characters with black edging, thus allowing easy reading against any contrast background. The number of input is displayed in the right corner and the sequential time in the left corner below. 7

SET - UP Switch off the unit. Press the key "8" and turn the power on. All LED lamps go off, power switch lights. Language menu is on the screen: > ENGLISH ITALIANO DEUTSCH Press the keys " " and " " to move the selector up and down and key " " as enter. Main menu is on the screen SET - UP > CHANNEL B ALARM REMOTE CONTROL LINE - LOCK ON - SCREEN Press " ": CHANNEL B > MODE SEQ. TIME INPUTS FRAMES (CHANNEL B set-up) Press " ": CH-B MODE > SEQUENTIAL VCR CLOCK FRAME (CHANNEL B mode - press " " to move the " " on the selector line) Press " " to exit, then " ". Press " ", then " ". CH-B SEQ. TIME (sequential time of CHANNEL B) > TIME Sec. 01 Press " " CH-B SEQ. TIME TIME Sec. 01 < (adjust sequential time with up/down selectors) Press " ": 8

CH-B SEQ. TIME > TIME Sec. 12 Press " ", then " ": Press " ", then " ": CH-B INPUTS (number of inputs on CHANNEL B) > NUMBER 8 Press " " and use up/down selectors to select the number. Press " ", then " ": Press " ", then " ": CH-B FRAMES > NUMBER 01 (number of frames on CHANNEL B) Press " " and use up/down selectors to select the number. Press " ", then " ". Press " ", then " ", the main menu is on the screen. Use up/down selectors to select the next menu: ALARM > ACTIVITY SEQ. TIME DURATION FRAME SWITCH TRIGGER (alarm set-up) ALARM ACTIVITY >*CH-A CH-B OFF (alarm activity) ALARM SEQ. TIME > TIME Sec. 01 (time between two or more alarms in the sequence) ALARM DURATION > TIME Sec. 01 (time of alarm duration) ALARM FRAME SW. (frame-by-frame switching on CHANNEL B) >*ON OFF 9

ALARM TRIGGER >*POSITIVE NEGATIVE (positive or negative alarm input signal triggering) In main menu select the next menu: REMOTE CONTROL (remote control possibility) >*ON OFF Next menu: LINE - LOCK (line-lock phase from -127 to +127) > NUMBER 000 Next menu: ON - SCREEN (on-screen displaying - CHANNEL A) > NUMBER DISPLAY TIME DISPLAY NUMBER DISPLAY >*ON OFF (displaying the number of input) TIME DISPLAY >*ON OFF (displaying the sequential time) Next menu: SAVE >YES NO SET - UP (saving the new set-up, select SET-UP for main menu) 10

STANDARD SETTING Switch off the unit. Press the key "1" and turn the power on. All settings are as follows: CHANNEL A: CHANNEL B: ALARM: REMOTE CONTROL: LINE-LOCK: -phase - 0 ON-SCREEN: -auto (sequential) mode -8 inputs -seq. time - 1 sec. -sequential mode -seq. time - 1 sec. -8 inputs -1 frame -activity - off -seq. time - 1 sec. -duration time - 20 sec. -frame sw. - off -trigger - negative -off -number display - on -time display - on SELF TEST Switch off the unit. Press the key "4" and turn the power on. All video inputs are sequentially switched to the both output channels accompanied with blinking LEDs. Buzzer is activated, SELF-TEST message is on the screen. INSTALLATION This unit is fully assembled prior to shipment, and is ready to operate immediately after unpacking. If there are any problems in ground loop-through between video sources (cameras, VCR etc.) and this unit, remove the seven screws on the cover s upper panel and open the upper lid. Then remove the GND connector from PCB. The video switcher ground will be separated from the cover and earth. Note: When the GND connector is removed it has to be isolated. TABLETOP UNIT This unit is fitted with rubber feet on the base plate for use as a tabletop unit. RACK MOUNTING For rack mounting, remove the rubber feet and use the optional rack mounting kits. 11

APPEARANCE 44 43225 163 210 216 283 One unit 44 5.9 5.9 482 Two units SPECIFICATIONS Video inputs 8 1 Vpp / 75 Ω, BNC Video outputs 2 1 Vpp / 75 Ω, BNC Video bandwidth 10 MHz ± 3 db Signal / noise ratio > 60 db Crosstalk 56 db (4.5 MHz) Switching interval adjustable, 1 to 90 sec. (CH A, CH B, alarm) VCR clock input TTL, negative triggered, terminal block Frame switching 1-99 frames Line-lock phase -2.2ms to +2.2ms (-127 steps to +127 steps) Alarm inputs 8 activity adjustable, D-9F connector Alarm output low-active, open collector, terminal block Alarm duration adjustable, 1 to 90 sec. or manual reset On - screen display input number, seq. time, alarm, set-up Nonvolatile RAM backup 100 years data retention. Power requirement 230 V, 50 Hz Power consumption max. 8 W Dimensions (W x H x D) 216 x 44 x 240 mm Weight 2.5 kg 12

PIN ASSIGNMENT Alarm input / remote control connector D-9F: PIN No. ALARM REMOTE 1 ALARM 1 T1 2 ALARM 2 T2 3 ALARM 3 n.c. 4 ALARM 4 n.c. 5 ALARM 5 n.c. 6 ALARM 6 n.c. 7 ALARM 7 n.c. 8 ALARM 8 n.c. 9 GND GND Alarm output / VCR Clock connector: PIN 1 ALARM OUT 2 GND 3 VCR CLOCK OPTIONAL ACCESSORY Rack mount kit 13