Heat meter Q heat 5 US



Similar documents
SHARKY 775 COMPACT ENERGY METER ULTRASONIC

HYDRUS ULTRASONIC METER

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

SONOMETER TM 1000 Ultrasonic compact heat meter

AMTRON E-30 Compact heat and cooling meter

Heat meters Cooling meters

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

MOUNTING AND OPERATING INSTRUCTIONS

The multi-functional integrator Supercal 531

Portable digital microprocessor thermometers with interchangeable probes

How To Use A Corona Mdi 110

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Instructions for assembly and use MULTICAL 601

Series description: Wilo-Yonos MAXO

T0118 T2118 T3118. Instruction Manual

Vacuum drying oven for non-flammable solvents

IFC 070 Technical Datasheet

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Series description: Wilo-Star-Z

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SHARKY 775 Ultrasonic Compact Energy Meter. Installation and User Guide

OZW30. Central Unit SYNERGYR

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Digital input modules

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

HERZ-Thermal Actuators

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Series description: Wilo-Yonos MAXO-D

Drayton Digistat +2RF/+3RF

COMBIMASS. Technical Data COMBIMASS eco-bio +

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Multi-Range Programmable DC Power Supplies 9115 Series

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Hand-held thermometer Model CTH7000

UGY. Planetary Gearbox UGY. Standard Data. Order Reference Example motor combination: with DC motor NF. Gearboxes. 20* x 12,7...

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA) Module S01 Fundamentals of CNC Programming with SinuTrain

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

Stove Guard Kit User Manual

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Heating, air-conditioning, cooling

Cable Plug acc. to DIN EN , Form A

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Instruction Manual. T3111 T3111L T3111P T3111Ex

Remote Meter Reading via M-Bus by Klaus-Peter Richter, Energy Management Product Manager GOSSEN METRAWATT GMBH

Assisted lift operated 2/2-way solenoid valves Type EV250B

Turbine Flow Sensor Series VTR

Proportional pressure regulators VPPE

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Series description: Wilo-Drain TC 40

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Self-operated Temperature Regulators Temperature Regulator Type 1u

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Heating oven with mechanical convection

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

suite 5 caloric module for reading and parameterisation of QUNDIS heat cost allocators 1/5 Q suite 5 caloric module

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Control- and feedback head for integrated mounting on Robolux valves Type 2036

SINEAX U553 Transducer for AC Voltage

Heating oven with mechanical control

Three-phase monitoring relay CM-PFE

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

MINI MCR-SL-R-UI(-SP)

Electric Rotary Actuator - On/Off or programmable control actuator

IN-OUT Thermometer with Cable Free Sensor and Clock

PHOENIX CONTACT Features

7 Lighting Technology

Material test chamber with mechanical convection

Precision Lightmeters Made in Germany

Incubator with mechanical convection

Threaded Resistance Thermometers Model TR10-D, Miniature Design

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Description of functions

Know what is going on inside the mold.

Smile. The All-In-One Heating Controller

Series 7500 Torque Sensor

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Relative and absolute pressure switch type 529

TX OPEN RS232/485 module

PS1800 Centrifugal Pumping Systems

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

G234X-55 Conventional Gas Boiler

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Redundancy Module QUINT-DIODE/40

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Transcription:

Data sheet DST1-QHEA-GB0 USCHA / 27.06.2016 - V 3.0 Heat meter Q heat 5 US Ultrasonic heat meter with ultrasonic measurement technology (runtime difference method) with IrDA interface and an interface for retrofitting external modules. Exact measurement of even very small flow quantities. Can be installed in any position, no moving parts in the volume flow. Extremely compact design height and detachable calculator unit as standard with long connection cable for universal use. Can be used in the Q opto, Q basic, Q M-Bus, Q walk-by and Q AMR systems. Can be retrofitted with external modules for use in the above-mentioned systems. www.qundis.com

Application The heat meter is used for measuring heat energy. The main areas of application are in central heating systems where the heating energy is outputted individually to different consumers. This is meaningful in: Apartment buildings Offices and administration buildings Functions IrDA interface for reading out and setting parameters for the heat meter. Mains-independent, for local use, 6 or 10-year lithium battery. Measured values are recorded using two PT 1000 platinum resistance thermometers. Can be installed in any position, no moving parts in the volume flow. Detachable calculator unit with connection cable 80 cm long and clip ring for wall attachment. High resolution thanks to 8-digit LC display that indicates current value, old value, check sum as well as many service and operating parameters. Display loop fast readout with the most important consumption values can be opened using control keys. Additional display of 15 monthly values with date. Storage of the maximum supply flow and return flow temperatures as well as the maximum current flow with date. Programming of the device-specific parameters (e.g. due date) is possible on site using the control keys or the IrDA interface. The communication technology required can be retrofitted in the field by means of add-on modules. Screw-type variant Heat meter Q heat 5 US for direct or indirect installation of the temperature sensors MID approval 2

Technology The heat meter comprises a pair of precise temperature sensors and an ultrasonic flow meter which is installed in a hot water circuit. An electronic calculator unit continually calculates the difference in temperature between the supply and return flow and the flow rate. The heating capacity calculated from the two values is cumulated, displayed or forwarded to a data-processing system by radio or cable. The Q heat 5 US is a heat meter that can be extended by various external modules. The Q heat 5 US has two communication interfaces. The IrDA interface accessible from outside. This allows parameters to be set for the Q heat 5 US on site at any time. The module interface, which can be used to retrofit the heat meter for radio or other communication methods. The respective modules are simply mounted on the calculator unit. Measuring principle The flow sensor of the screw-type meter works according to the ultrasonic measuring principle. The water flow through the meter is measured using acoustic sensors. The low-maintenance design and lack of mechanically moving parts for the determination of exact volume flow are the key features of this measuring principle. Incorrect direction of flow is detected and indicated by an error message in the display. NOTE: Only use water without chemical additives as the medium for this device. Glycol additives are expressly not permitted. Heating systems must be bled completely before start-up. Determining water consumption Using the measured difference in temperature between supply and return flow, the flow rate and the calculated thermal coefficient, the heat quantity is shown on the LC display in physical units (kwh, MWh, MJ, GJ) following an internal calculation process. Storing the consumption values The heat consumption values are continually cumulated. The current status is stored at 24.00 h on the due date. The due date is set with the aid of the two keys or a programming tool, December 31 is the default setting. Every time the current consumption and the annual consumption is saved, the heat meter calculates a checksum. This can be read out together with the due date value and checked in the billing program. This allows incorrect display readouts (e.g. switched digits ) to be detected. The stored due date value remains in place for one year. 3

Display Device states, display units and consumption values are shown via the LC display on several levels (up to 6). The heat meter is equipped with two keys that can be used to switch between the individual display steps and levels. The display is off as standard (sleep mode). The display can be activated by pressing a key. Opening the fast readout display loop: Press the < H > or < V > key briefl y to open the fast readout display loop. Current value 5 Sec. The fast readout display starts with the current consumption value. Display test - everything on 0,5 Sec. Display test - everything off 0,5 Sec. Due date 5 Sec. Due date value 5 sec. pulsating 10 x After 10 repetitions, the display automatically changes back to sleep mode. You can change to the level operating scheme at any time. To do so, press the < H > or < V > key for longer than 3 seconds. Error messages are displayed with the error number and error date for 5 seconds before the Current value display. Opening the level operating scheme of the standard levels: Press the < H > or < V > key longer than 3 seconds to open the level operating scheme. Standard loop (*) Meter status displays depend on the device configuration! Display off Current meter status heat (*) Current meter status cool Meter status heat on due date (*) Meter status cool on due date alt. alt. alt. alt. Error messages Error code Error date alt. If a serious error occurs with the device, the error code and error date are displayed before the meter status. Incorrect direction of flow If the incorrect direction of flow is established, an error message appears on the display as shown. Key for changing level Key for moving within a level 4

Display Overview of display levels L0 L1 Current consumption values Annual consumption values Standard levels L2 Current values L3 L5 Parameters Monthly values heat The levels coloured grey can all be switched off separately. L9 Maximum values Key for changing level Key for moving within a level 5

Parameter-setting possibilities Via keys: Next due date Display in kwh or MWh or MJ or GJ Selection of the levels to be displayed Display of the meter statuses with or without check number With PC: Next due date Password for close-range interface Display in kwh or MWh or MJ or GJ Selection of the levels to be displayed Display of the meter statuses with or without check number Only the wireless measuring devices additionally transmit status information several times a day the whole year round independently of the readout time set. Pressure loss curves Complete heat meters 1000 Pressure loss Q heat 5 US Pressure loss (mbar) 180 130 100 10 100 1500 2500 10000 Volume flow (l/h) Nominal flow qp 1.5 m 3 /h = orange Nominal flow qp 2.5 m 3 /h = green 6

Technical data Norms and standards Conformity Electromagnetic compatibility Interference resistance EN 61000-6-2 Emitted interference EN 61000-6-3 Protection rating see EU Declaration of Conformity IP protective rating Calculator unit/flow sensor IP65 according to EN 60529 Heat meters European Measuring Instruments Directive (MID) EC type examination certificate Heat meters 2004/22/EG DE-14-MI004-PTB006 CEN EN1434 Quality of heat medium in accordance with VDI guideline 2035 in accordance with AGFW standard 510 Influencing quantities Electromagnetic class Mechanical class Environment class Precision class 3 E1 M2 A Calculator unit Temperature range as heat meter 20 C... 90 C permissible temperature difference start of metering temperature difference 3 K - 160 K 1,0 K Ambient temperature 5 C... 55 C Power supply Lithium battery Service life Display levels Standard Display Energy display Cable length Calculator unit - fl ow sensor Nominal voltage 3.0 V > 6 (opt. 10) years + 6 months reserve min. 2, up to 6 (depending on the version and options included) 8-digit LCD + pictograms kwh <--> MWh (optionally MJ <--> GJ) approx. 80 cm Temperature sensor Measuring element PT 1000 according to EN 60751 Version Typ DS Diameter 5,0 mm - 5,2 mm Type of installation 5.0 mm - direct (ball valve) / indirect (immersion sleeve)* 5.2 mm - direct (ball valve) / indirect (immersion sleeve)* Cable length Standard Optional 1,5 m 3,0 m * Note national and country-specific regulations concerning the use of immersion sleeves. 7

Flow sensor Screw-type meter Connection sizes and dimensions 1,5 m³/h 2,5 m³/h Length 110 mm 130 mm Connection G ¾ B G 1 B Weight Calculator unit detachable 530 g 660 g Installation position Nominal flow qp 1,5 m³/h 2,5 m³/h Minimum flow qi 15 l/h 25 l/h Maximum flow qs 3000 l/h 5000 l/h Start-up limit q 0 1,5 l/h to 4,0 l/h 2,5 l/h to 6,5 l/h Max. permissible operating pressure Min. system pressure to avoid cavitation (cavity formation) any 16 bar 1 bar Temperature range 20 C... 90 C Dynamic range qp/qi 1:100 8

Dimensional drawings Das Urheberrecht an dieser Zeichnung verbleibt uns. Jede Vervielfältigung oder Mit teilung an Dritte sowie mißbräuchliche Verwertung in anderer Weise ist nicht gestattet. Installation length 110 mm - 3/4 inch thread G 3/4 A 101,4 G 3/4 A 64,8 52,1 110 "NOTE PROTECTION MARK: ACC: DIN 34" Installation length 130 mm - 1 inch thread Das Urheberrecht an dieser Zeichnung verbleibt uns. Jede Vervielfältigung oder Mit teilung an Dritte sowie mißbräuchliche Verwertung in anderer Weise ist nicht gestattet. G 1 A 101.4 78 G 1 A 64,8 (Verwendungbereich) Tolerierungsgrundsatz nach ISO 8015 Zust. Änderung Datum Name 68,8 52,1 Allgemein- Toleranz ISO 2768-mH Bearb. Gepr. Norm Datum XXXX (Firma, Zeichnungs-Ersteller) (Urspr.) Name Hintz (Maßstab) (Werkstoff)) (Benennung) (Zeichnungsnummer)) Ers. für: X : X XXXXXXXX (Gewicht) XXXXXXXXXXXX 59XXXX Ers.durch: Blatt 1 1 Blätter 130 "NOTE PROTECTION MARK: ACC: DIN 34" 78 (Verwendungbereich) Tolerierungsgrundsatz nach ISO 8015 Allgemein- Toleranz ISO 2768-mH XXXXXXXXXXXX 9 DST1-QHEA-GB0 USCHA (Firma, Zeichnungs-Ersteller) Ultrasound heat meter Q heat 5 US - data sheet (Zeichnungsnummer)) 27.06.2016 59XXXX - V 3.01 Zust. Änderung Datum Name Bearb. Gepr. Norm (Urspr.) Datum XXXX Name Hintz (Maßstab) (Werkstoff)) (Benennung) Ers. für: X : X XXXXXXXX Ers.durch: (Gewicht) 1 Blatt Blätter

QUNDIS GmbH Sonnentor 2 99098 Erfurt / Germany +49 (0) 361 26 280-0 +49 (0) 361 26 280-175 info@qundis.com www.qundis.com The information in this data sheet only contains general descriptions or product characteristics, which may not always apply in particular application cases and/or may be subject to change through further development of the product. Required product characteristics are then binding if they are expressly agreed when the contract is drawn up. 2016 QUNDIS GmbH. Subject to change 10